Daniel Heinert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Heinert has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
A Tünnermann
Institut für Angewandte Physik, Albert-Einstein-Str. 15, 07745 Jena, Germany
3 shared publicationsC Schwarz
Institut für Festkörperphysik, Friedrich-Schiller-Universität, 07743 Jena, Germany
3 shared publicationsP Seidel
Institut für Festkörperphysik, Friedrich-Schiller-Universität, 07743 Jena, Germany
3 shared publicationsR Nawrodt
Institut für Festkörperphysik, Friedrich-Schiller-Universität, 07743 Jena, Germany
3 shared publicationsA Grib
Institut für Festkörperphysik, Friedrich-Schiller-Universität, 07743 Jena, Germany
2 shared publicationsJ Hough
Institute for Gravitational Research, Department of Physics and Astronomy, Glasgow University, G12 8QQ Glasgow, UK
2 shared publications
Latest Publications
- Open Access
- 7 August 2014
- Published by American Physical Society (APS) in Physical Review D
- Vol. 90 (4) , 042001
Thermal noise of folding mirrors
Current gravitational-wave detectors rely on the use of Michelson interferometers. One crucial limitation of their sensitivity is the thermal noise of their optical components. Thus, for example, fluctuational deformations of the mirror surface are probed by a laser beam being reflected from the mirrors at normal incidence. Thermal noise models are well evolved for that case but mainly restricted to single reflections. In this work, we present the effect of two consecutive reflections under a non-normal incidence onto mirror thermal noise. This situation is inherent to detectors using a geometrical folding scheme such as GEO 600. We revise in detail the conventional direct noise analysis scheme to the situation of non-normal incidence allowing for a modified weighting function of mirror fluctuations. An application of these results to the GEO 600 folding mirror for Brownian, thermoelastic, and thermorefractive noise yields an increase of displacement noise amplitude by 20% for most noise processes. The amplitude of thermoelastic substrate noise is increased by a factor of 4 due to the modified weighting function. Thus, the consideration of the correct weighting scheme can drastically alter the noise predictions and demands special care in any thermal noise design process.
- 7 August 2014
- Published by American Physical Society (APS) in Physical Review D
- Vol. 90 (4) , 042001
Open AccessThermal noise of folding mirrors
Current gravitational-wave detectors rely on the use of Michelson interferometers. One crucial limitation of their sensitivity is the thermal noise of their optical components. Thus, for example, fluctuational deformations of the mirror surface are probed by a laser beam being reflected from the mirrors at normal incidence. Thermal noise models are well evolved for that case but mainly restricted to single reflections. In this work, we present the effect of two consecutive reflections under a non-normal incidence onto mirror thermal noise. This situation is inherent to detectors using a geometrical folding scheme such as GEO 600. We revise in detail the conventional direct noise analysis scheme to the situation of non-normal incidence allowing for a modified weighting function of mirror fluctuations. An application of these results to the GEO 600 folding mirror for Brownian, thermoelastic, and thermorefractive noise yields an increase of displacement noise amplitude by 20% for most noise processes. The amplitude of thermoelastic substrate noise is increased by a factor of 4 due to the modified weighting function. Thus, the consideration of the correct weighting scheme can drastically alter the noise predictions and demands special care in any thermal noise design process.
- Open Access
Calculation of thermal noise in grating reflectors
Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed 3rd generation gravitational wave detector. Depending on the grating geometry, the grating material and the temperature we obtain a thermal noise decrease by up to a factor of ten compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.
Open AccessCalculation of thermal noise in grating reflectors
Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed 3rd generation gravitational wave detector. Depending on the grating geometry, the grating material and the temperature we obtain a thermal noise decrease by up to a factor of ten compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.
- 8 August 2013
- Published by American Physical Society (APS) in Physical Review D
- Vol. 88 (4)
Calculation of thermal noise in grating reflectors
Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed third generation gravitational wave detector. Depending on the grating geometry, the grating material, and the temperature, we obtain a thermal noise decrease by up to a factor of 10 compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.
- 8 August 2013
- Published by American Physical Society (APS) in Physical Review D
- Vol. 88 (4)
Calculation of thermal noise in grating reflectors
Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed third generation gravitational wave detector. Depending on the grating geometry, the grating material, and the temperature, we obtain a thermal noise decrease by up to a factor of 10 compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.
- 15 September 2011
- Published by American Physical Society (APS) in Physical Review D
- Vol. 84 (6)
Publisher’s Note: Thermorefractive noise of finite-sized cylindrical test masses [Phys. Rev. D84, 062001 (2011)]
- 15 September 2011
- Published by American Physical Society (APS) in Physical Review D
- Vol. 84 (6)
Publisher’s Note: Thermorefractive noise of finite-sized cylindrical test masses [Phys. Rev. D84, 062001 (2011)]
- Open Access
- 1 May 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 228 (1) , 012032
Potential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
- 1 May 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 228 (1) , 012032
Open AccessPotential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
- Open Access
Potential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
Low mechanical loss materials are needed to further decrease thermal noise in upcoming gravitational wave detectors. We present an analysis of the contribution of Akhieser and thermoelastic damping on the experimental results of resonant mechanical loss measurements. The combination of both processes allows the fit of the experimental data of quartz in the low temperature region (10 K to 25 K). A fully anisotropic numerical calculation over a wide temperature range (10 K to 300 K) reveals, that thermoelastic damping is not a dominant noise source in bulk silicon samples. The anisotropic numerical calculation is sucessfully applied to the estimate of thermoelastic noise of an advanced LIGO sized silicon test mass.
Open AccessPotential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
Low mechanical loss materials are needed to further decrease thermal noise in upcoming gravitational wave detectors. We present an analysis of the contribution of Akhieser and thermoelastic damping on the experimental results of resonant mechanical loss measurements. The combination of both processes allows the fit of the experimental data of quartz in the low temperature region (10 K to 25 K). A fully anisotropic numerical calculation over a wide temperature range (10 K to 300 K) reveals, that thermoelastic damping is not a dominant noise source in bulk silicon samples. The anisotropic numerical calculation is sucessfully applied to the estimate of thermoelastic noise of an advanced LIGO sized silicon test mass.
- Open Access
- 1 December 2007
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 92 (1) , 012183
High-sensitivity tool for studying phonon related mechanical losses in low loss materials
Fundamental mechanical loss mechanisms exist even in very pure materials, for instance, due to the interactions of excited acoustic waves with thermal phonons. A reduction of these losses in a certain frequency range is desired in high precision instruments like gravitational wave detectors. Systematic analyses of the mechanical losses in those low loss materials are essential for this aim, performed in a highly sensitive experimental set-up. Our novel method of mechanical spectroscopy, cryogenic resonant acoustic spectroscopy of bulk materials (CRA spectroscopy), is well suited to systematically determine losses at the resonant frequencies of the samples of less than 10-9 in the wide temperature range from 5 to 300 K. A high precision set-up in a specially built cryostat allows contactless excitation and readout of the oscillations of the sample. The experimental set-up and measuring procedure are described. Limitations to our experiment due to external loss mechanisms are analysed. The influence of the suspension system as well as the sample preparation is explained.
- 1 December 2007
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 92 (1) , 012183
Open AccessHigh-sensitivity tool for studying phonon related mechanical losses in low loss materials
Fundamental mechanical loss mechanisms exist even in very pure materials, for instance, due to the interactions of excited acoustic waves with thermal phonons. A reduction of these losses in a certain frequency range is desired in high precision instruments like gravitational wave detectors. Systematic analyses of the mechanical losses in those low loss materials are essential for this aim, performed in a highly sensitive experimental set-up. Our novel method of mechanical spectroscopy, cryogenic resonant acoustic spectroscopy of bulk materials (CRA spectroscopy), is well suited to systematically determine losses at the resonant frequencies of the samples of less than 10-9 in the wide temperature range from 5 to 300 K. A high precision set-up in a specially built cryostat allows contactless excitation and readout of the oscillations of the sample. The experimental set-up and measuring procedure are described. Limitations to our experiment due to external loss mechanisms are analysed. The influence of the suspension system as well as the sample preparation is explained.