ALAndré P. De Leenheer

André P. De Leenheer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


André P. De Leenheer has a total of 89 co-authors. Here are the top co-authors by number of shared publications:

  • M. Piette

    Laboratorium voor Gerechtelijke Geneeskunde, Universiteit Gent , J. Kluyskensstraat 29, B-9000 Gent, Belgium

    7 shared publications
  • W. Lambert

    Laboratorium voor Toxicologie, Universiteit Gent , Harelbekestraat 72, B-9000 Gent, Belgium

    7 shared publications
  • C. Van Peteghem

    Laboratorium voor Toxicologie, Universiteit Gent , Harelbekestraat 72, B-9000 Gent, Belgium

    6 shared publications
  • Willy E. Lambert

    Laboratorium voor Toxicologie, Universiteit Gent, Harelbekestraat 72, B‐9000 Gent, Belgium

    6 shared publications
  • E. Meyer

    Laboratorium voor Toxicologie, Universiteit Gent, Belgium

    5 shared publications
  • J. Van Bocxlaer

    Laboratoria voor Medische Biochemie en voor Klinische Analyse, Universiteit Gent , Harelbekestraat 72, B-9000 Gent, Belgium

    5 shared publications

Latest Publications

  • Open Access

    Fatality Due To Combined Use of the Designer Drugs MDMA and PMA: A Distribution Study

    by R. Dams, E.A. De Letter, K.A. Mortier, J.A. Cordonnier, W.E. Lambert, M.H.A. Piette, S. Van Calenbergh, A.P. De Leenheer

    We present a fatal case involving the combined ingestion of amphetamine, 3,4-methylenedioxymethylamphetamine, 3,4-methylenedioxyamphetamine, and paramelhoxyamphelamine. Various postmortem specimens (e.g., several blood samples, urine, and tissue samples) were analyzed to study the distribution of the compounds and their metabolites in the human body. Quantitation took place using liquid chromatography-sonic spray ionization-mass spectrometry after pretreatment with a liquid-liquid extraction. The medico-legal findings were compatible with a disseminated intravascular coagulation induced by hyperthermia caused by the simultaneous intake of the amphetamine analogues.


  • Open Access

    Analysis of Flecainide and Two Metabolites in Biological Specimens by HPLC: Application to a Fatal Intoxication

    by T. Benijts, D. Borrey, W.E. Lambert, E.A. De Letter, M.H.A. Piette, C. Van Peteghem, A.P. De Leenheer

    A few days after her admittance to a hospital for a suicide attempt with benzodiazepines, a 15-year-old girl was found dead in bed. At autopsy, no specific anatomo-pathologic cause of death was identified. Systematic toxicological analysis (HPLC-DAD, GC-NPD, and GC-MS) of postmortem blood and urine revealed the presence of high concentrations of flecainide and its two major metabolites. Flecainide is a class IC anti-arrhythmic drug causing a decreased intracardiac conduction velocity in all parts of the heart. To identify and quantitate flecainide together with its metabolites in blood, urine, and other toxicologically relevant matrices, a new method was developed using high-performance liquid chromatography with diode-array detection. All compounds were separated on a Hypersil BDS phenyl column using water, methanol, and 1.5M ammonium acetate in a gradient system. Chromatographic analysis was preceded by an optimized solid-phase extraction procedure on RP-C18 extraction columns. The flecainide concentrations in blood and urine were 18.73 and 28.3 mg/L, respectively, and the metabolites were detected only in urine at the following concentrations: 9.4 mg/L for meta-O-dealkylated flecainide and 8.59 mg/L for meta-O-dealkylated flecainide lactam. Based on these results, it was concluded that the suicide was consistent with an overdose of this anti-arrhythmic drug.


  • Open Access

    Enzymatic Hydrolysis Improves the Sensitivity of Emit Screening for Urinary Benzodiazepines

    by Danielle Borrey, Evelyne Meyer, Luc Duchateau, Willy Lambert, Carlos Van Peteghem, Andreas De Leenheer

    Screening for benzodiazepines is routinely performed by immunochemical analysis, such as enzyme immunoassay. However, the wide range of therapeutic and toxic concentrations of the different benzodiazepines and their extensive metabolism and conjugation hamper the design of an immunoassay protocol that can detect all benzodiazepines and their corresponding urinary metabolites. Multiple commercially available immunoassay methods exist, but false-negative (FN) results are still encountered, even with some frequently prescribed benzodiazepines.


  • Influence of the eluent composition on the ionization efficiency for morphine of pneumatically assisted electrospray, atmospheric‐pressure chemical ionization and sonic spray

    by Riet Dams, Tom Benijts, Wolfgang Günther, Willy Lambert, André De Leenheer

    A comparative study of three atmospheric‐pressure ionization (API) sources for liquid chromatography/mass spectrometry (LC/MS), namely pneumatically assisted electrospray or ionspray (IS), atmospheric‐pressure chemical ionization (APCI), and sonic spray (SS), with respect to the influence of the eluent composition on the ionization of morphine, is presented. The effect of organic modifiers, volatile acids, and buffer systems (with and without pH adjustment) in the LC mobile phase on the ionization efficiency of each interface is described. We conclude that for all three ion sources, the composition of the liquid phase had a serious impact on the ionization of the target compound. For IS and SS, very similar behavior towards the LC eluent was observed. In both cases, an increase in organic modifier resulted in an increase in ionization, while an increasing amount of volatile acid or buffer caused signal suppression. APCI, on the other hand, proved to respond completely differently towards the changes in the eluent. Again, an increased ionization was observed with an increase in organic modifier content but this time also in the presence of mobile phase additives like acids or buffers. Finally, we concluded that APCI proved to be the preferred ion source for the test compound because of its robust character and its direct applicability in traditional LC analysis. Copyright © 2002 John Wiley & Sons, Ltd.


  • Determination of paramethoxyamphetamine and other amphetamine‐related designer drugs by liquid chromatography/sonic spray ionization mass spectrometry

    by Kjell A. Mortier, Riet Dams, Willy E. Lambert, Els A. De Letter, Serge Van Calenbergh, André P. De Leenheer

    Paramethoxyamphetamine (PMA) is an amphetamine‐like designer drug that has emerged recently on the European illicit drug market. This drug has a wicked reputation, as a number of lethal intoxications have occurred. A method using high‐performance liquid chromatography coupled to ion trap based mass spectrometry (LC/MS) is described for the determination of this compound together with 3,4‐methylenedioxymethamphetamine (XTC or MDMA), amphetamine and 3,4‐methylenedioxyamphetamine (MDA) in human matrices. A liquid/liquid extraction (LLE) was applied to whole blood, urine and postmortem tissues. Reversed‐phase liquid chromatography was performed on a narrow‐bore phenyl‐type column at a flow rate of 0.3 mL/min. A switch box allowed disposal of early‐eluting irrelevant material to waste, protecting the mass spectrometer from contamination. The column effluent was directed into an ion trap mass spectrometer by a sonic spray ionization (SSI) interface. The method was validated for all three matrices, proving the applicability of SSI even when dealing with complex biological matrices. The within‐and between‐day precisions were less than 17.5% and accuracy was below 16.2%. Weighted (1/x) quadratic calibration curves were generated ranging from 10 to 1000 ng/mL (blood and urine) or 20 to 2000 ng/g (tissue) and correlation coefficients (r 2 ) always exceeded 0.995. In addition, the mass spectrum of PMA is given together with a proposed fragmentation pattern for the obtained LC/MS spectrum. This information can be useful for future identification of PMA with LC/MS in biological matrices as well as in confiscated powders or tablets. Copyright © 2002 John Wiley & Sons, Ltd.


  • Open Access

    Quantitative Determination of n-Propane, iso-Butane, and n-Butane by Headspace GC-MS in Intoxications by Inhalation of Lighter Fluid*

    by Marie-Paule L.A. Bouche, Willy E. Lambert, Jan F.P. Van Bocxlaer, Michel H. Piette, André P. De Leenheer

    This report describes a fully elaborated and validated method for quantitation of the hydrocarbons n-propane, iso-butane, and n-butane in blood samples. The newly developed analytical procedure is suitable for both emergency cases and forensic medicine investigations. Its practical applicability is illustrated with a forensic blood sample after acute inhalative intoxication with lighter fluid; case history and toxicological findings are included. Identification and quantitation of the analytes were performed using static headspace extraction combined with gas chromatography-mass spectrometry. In order to reconcile the large gas volumes injected (0.5 mL) with the narrowbore capillary column and thus achieve preconcentration, cold trapping on a Tenax sorbent followed by flash desorption was applied. Adequate retention and separation were achieved isothermally at 35°C on a thick-film capillary column. Sample preparation was kept to a strict minimum and involved simply adding 2.5 µL of a liquid solution of 1,1,2-trichlorotrifluoroethane in t-butyl-methylether as an internal standard to aliquots of blood in a capped vial. Standards were created by volumetric dilution departing from a gravimetrically prepared calibration gas mixture composed of 0.3% of n-propane, 0.7% of iso-butane, and 0.8% of n-butane in nitrogen. In the forensic blood sample, the following concentrations were measured: 90.0 µg/L for n-propane, 246 µg/L for iso-butane, and 846 µg/L for n-butane.


  • Open Access

    Fatal 4-MTA Intoxication: Development of a Liquid Chromatographic-Tandem Mass Spectrometric Assay for Multiple Matrices

    by T. Decaestecker, E. De Letter, K. Clauwaert, M.P. Bouche, W. Lambert, J. Van Bocxlaer, M. Piette, E. Van Den Eeckhout, C. Van Peteghem, A. De Leenheer

    The case history and toxicological findings of an overdose fatality involving 4-methylthioamphetamine (4-MTA) and 3,4-methylenedioxymethamphetamine (MDMA) are reported along with a description of the analytical method. Detection and quantitation of 4-MTA and MDMA were performed by liquid chromatography—tandem mass spectrometry using phentermine as internal standard. Application of this technique to a variety of matrices allowed an insight in the distribution of 4-MTA. Several blood samples including femoral vein blood (5.23 mg/L), urine (95.5 mg/L), vitreous humor (1.31 mg/L), bile (36.4 mg/L), and numerous tissue samples such as liver (30.8 mg/kg), spleen (4.10 mg/kg), and frontal lobe (31.7 mg/kg) were assayed. These values indicated that 4-MTA could be identified as the cause of this fatality, whereas the concentrations of MDMA, also described, are less important because the concentrations found are lower. This case reports, for the first time, an extensive toxicological analysis of 4-MTA, by which the data presented may shed some light on the distribution of 4-MTA.


  • Open Access

    A Fatal Case of Moclobemide--Citalopram Intoxication: Reply

    by R. Dams, T. H. P. Benijts, W. E. Lambert, J. F. Van Bocxlaer, C. Van Peteghem, A. De Leenheer, D. Van Varenbergh

  • Pitfalls associated with liquid chromatography/electrospray tandem mass spectrometry in quantitative bioanalysis of drugs of abuse in saliva

    by Kjell A. Mortier, Karine M. Clauwaert, Willy E. Lambert, Jan F. Van Bocxlaer, Elfriede G. Van Den Eeckhout, Carlos H. Van Peteghem, André P. De Leenheer