Supraja Murali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Supraja Murali has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jannick P. Rolland
University of Rochester, The Institute of Optics, Rochester, New York, United States
2 shared publications - Kye-Sung Lee
The Institute of Optics, Univ. of Rochester (United States)
2 shared publications Anand Santhanam
1 shared publicationAyesha Mahmood
1 shared publication- Ilhan Kaya
Department of Electrical Engineering and Computer Science, Univ. of Central Florida, 4000 Central Florida Blvd., Orlando, FL, 32816, USA
1 shared publication Jaime Duarte
1 shared publication
Latest Publications
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7203, 720317
Optical coherence microscopy for nondestructive 3D imaging of femtosecond laser written structures
Optical coherence microscopy (OCM) is used to image femtosecond laser direct written buried structures created within transparent media. Volumetric structures of optical damage and laser-induced refractive index change were produced in fused silica and borosilicate glass, respectively. Noninvasive 3D imaging of the structures was successfully demonstrated by a custom built OCM. High signal to noise ratio was obtained since the optical glasses have high transparency at the probe wavelength centered at 800 nm.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7203, 720317
Optical coherence microscopy for nondestructive 3D imaging of femtosecond laser written structures
Optical coherence microscopy (OCM) is used to image femtosecond laser direct written buried structures created within transparent media. Volumetric structures of optical damage and laser-induced refractive index change were produced in fused silica and borosilicate glass, respectively. Noninvasive 3D imaging of the structures was successfully demonstrated by a custom built OCM. High signal to noise ratio was obtained since the optical glasses have high transparency at the probe wavelength centered at 800 nm.
- 13 January 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (2) , 145-147
Three-dimensional adaptive microscopy using embedded liquid lens
We report on the compact optical design of a high-resolution 3D scanning microscope with adaptive optics capability for refocusing with no moving parts designed for clinical research. The optical aberrations arising from refocusing are compensated for as part of the multiconfiguration optical design process. The lateral scanning is provided by a scanning mirror, and the depth scan is provided by an adaptive liquid lens embedded within the microscope as an integrated component of a custom optical design. The microscope achieves a performance of —a tenfold increase in performance over a liquid lens used as a stand-alone optical element. Results show that the optical design provides invariant modular transfer function over a imaging volume, fully compensating (i.e., diffraction limited) for dynamic aberrations contributed by the scanning, the variation in the shape of the liquid lens, and the change in spherical aberration with depth in a slab of average index of refraction of skin. This design can find applications in biomedical imaging, white light interferometry for surface roughness measurements, and other 3D imaging systems.- 13 January 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (2) , 145-147
Three-dimensional adaptive microscopy using embedded liquid lens
We report on the compact optical design of a high-resolution 3D scanning microscope with adaptive optics capability for refocusing with no moving parts designed for clinical research. The optical aberrations arising from refocusing are compensated for as part of the multiconfiguration optical design process. The lateral scanning is provided by a scanning mirror, and the depth scan is provided by an adaptive liquid lens embedded within the microscope as an integrated component of a custom optical design. The microscope achieves a performance of —a tenfold increase in performance over a liquid lens used as a stand-alone optical element. Results show that the optical design provides invariant modular transfer function over a imaging volume, fully compensating (i.e., diffraction limited) for dynamic aberrations contributed by the scanning, the variation in the shape of the liquid lens, and the change in spherical aberration with depth in a slab of average index of refraction of skin. This design can find applications in biomedical imaging, white light interferometry for surface roughness measurements, and other 3D imaging systems.- 1 January 2008
- Vol. 132, 426-32
Collaborative engineering: 3-D optical imaging and gas exchange simulation of in-vitro alveolar constructs.
This paper reports on the computational simulation and modeling of an in vitro alveolar construct system along the optical coherence microscopy (OCM) methods for visualizing engineered tissue. The optical imaging methods will be compared to immunohistochemical light microscopy samples of engineered alveolar constructs. Results show depth images of the alveolar tissue construct for a bilayer construct, as well as predictions of the gas exchange process in a simple model of a bio-reactor hosting the construct.
- 1 January 2008
- Vol. 132, 426-32
Collaborative engineering: 3-D optical imaging and gas exchange simulation of in-vitro alveolar constructs.
This paper reports on the computational simulation and modeling of an in vitro alveolar construct system along the optical coherence microscopy (OCM) methods for visualizing engineered tissue. The optical imaging methods will be compared to immunohistochemical light microscopy samples of engineered alveolar constructs. Results show depth images of the alveolar tissue construct for a bilayer construct, as well as predictions of the gas exchange process in a simple model of a bio-reactor hosting the construct.
- 14 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6342
Dynamic-focusing microscope objective for optical coherence tomography
Optical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique - ultrasound. In this paper, the application of high resolution OCT, known as optical coherence microscopy (OCM) is investigated for in vivo detection of abnormal skin pathology for the early diagnosis of cancer. A main challenge in OCM is maintaining invariant resolution throughout the sample. The technology presented is based on a dynamic focusing microscope imaging probe conceived for skin imaging and the detection of abnormalities in the epithelium. A novel method for dynamic focusing in the biological sample is presented using variable-focus lens technology to obtain three dimensional images with invariant resolution throughout the cross-section and depth of the sample is presented and discussed. A low coherence broadband source centered at near IR wavelengths is used to illuminate the sample. The design, analysis and predicted performance of the dynamic focusing microscope objective designed for dynamic three dimensional imaging at 5μm resolution for the chosen broadband spectrum is presented.
- 14 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6342
Dynamic-focusing microscope objective for optical coherence tomography
Optical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique - ultrasound. In this paper, the application of high resolution OCT, known as optical coherence microscopy (OCM) is investigated for in vivo detection of abnormal skin pathology for the early diagnosis of cancer. A main challenge in OCM is maintaining invariant resolution throughout the sample. The technology presented is based on a dynamic focusing microscope imaging probe conceived for skin imaging and the detection of abnormalities in the epithelium. A novel method for dynamic focusing in the biological sample is presented using variable-focus lens technology to obtain three dimensional images with invariant resolution throughout the cross-section and depth of the sample is presented and discussed. A low coherence broadband source centered at near IR wavelengths is used to illuminate the sample. The design, analysis and predicted performance of the dynamic focusing microscope objective designed for dynamic three dimensional imaging at 5μm resolution for the chosen broadband spectrum is presented.