I. A. Schneider
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
I. A. Schneider has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
A. Wokaun
7 shared publicationsG. G. Scherer
6 shared publicationsS. von Dahlen
Fuel Cell Diagnostics Activities, Paul Scherrer Institut, Electrochemistry Laboratory, 5232 Villigen PSI, Switzerland
5 shared publicationsD. Kramer
Paul Scherrer Institut, Electrochemistry Laboratory, 5232 Villigen PSI, Switzerland
3 shared publicationsM. H. Bayer
Paul Scherrer Institut, Electrochemistry Laboratory, Fuel Cell Diagnostics Activities, CH-5232 Villigen PSI, Switzerland
3 shared publicationsH. Kuhn
Paul Scherrer Institut, Electrochemistry Laboratory, 5232 Villigen PSI, Switzerland
2 shared publications
Latest Publications
- 1 January 2013
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 689, 42-45
Application of the Kramers Kronig relations to locally resolved impedance data of polymer electrolyte fuel cells
- 1 January 2013
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 689, 42-45
Application of the Kramers Kronig relations to locally resolved impedance data of polymer electrolyte fuel cells
- 14 November 2012
- Published by Wiley in Fuel Cells
- Vol. 12 (6) , 1004-1008
Local Flooding Phenomena in Channel and Land Areas Occurring during Dynamic Operation of a PEFC
- 14 November 2012
- Published by Wiley in Fuel Cells
- Vol. 12 (6) , 1004-1008
Local Flooding Phenomena in Channel and Land Areas Occurring during Dynamic Operation of a PEFC
- 29 February 2012
- Published by Wiley in Fuel Cells
- Vol. 12 (3) , 320-325
Dynamic Response of a Subsaturated Polymer Electrolyte Fuel Cell in Counterflow Mode
This work demonstrates that the operation of a subsaturated polymer electrolyte fuel cell in counterflow mode results in a significantly elongated relaxation time after a load change, if compared to coflow mode. This effect is investigated here by using combined dynamic locally resolved measurements of the current density, the high frequency resistance, and the relative humidity. It is shown that the elongated relaxation time is a consequence of slow membrane hydration in the region of the cell, downstream the anode flow field, where the diffusive flux of water across the membrane occurs from the anode to the cathode. Here, the anode gas stream, which is humidified upstream the anode flow field via back diffusion of water from the cathode to the anode, is the only source of water for both membrane hydration and the internal humidification of the cathode gas stream, which passes the cell in opposite direction.
- 29 February 2012
- Published by Wiley in Fuel Cells
- Vol. 12 (3) , 320-325
Dynamic Response of a Subsaturated Polymer Electrolyte Fuel Cell in Counterflow Mode
This work demonstrates that the operation of a subsaturated polymer electrolyte fuel cell in counterflow mode results in a significantly elongated relaxation time after a load change, if compared to coflow mode. This effect is investigated here by using combined dynamic locally resolved measurements of the current density, the high frequency resistance, and the relative humidity. It is shown that the elongated relaxation time is a consequence of slow membrane hydration in the region of the cell, downstream the anode flow field, where the diffusive flux of water across the membrane occurs from the anode to the cathode. Here, the anode gas stream, which is humidified upstream the anode flow field via back diffusion of water from the cathode to the anode, is the only source of water for both membrane hydration and the internal humidification of the cathode gas stream, which passes the cell in opposite direction.
- 1 January 2012
- Published by Elsevier
Contributor contact details
- Open Access
- 1 January 2011
- Published by The Electrochemical Society in Electrochemical and Solid-State Letters
- Vol. 14 (2) , B30-B33
Start-Stop Phenomena in Channel and Land Areas of a Polymer Electrolyte Fuel Cell
This work proves that the reverse-current phenomenon occurs in polymer electrolyte fuel cells even in small regions of channels and lands on a length scale of fractions of a millimeter. The effect of the flow field design, proposed mitigation strategies, and operation conditions are evaluated by using submillimeter resolved current distribution measurements during start-up and shutdown experiments. The results demonstrate that a high gas flow rate and a short fuel gas introduction time cannot avoid mass transport limitations underneath the ribs, which cause temporarily an inhomogeneous gas distribution over the fuel electrode and in-plane current transients in the lateral direction.
- 1 January 2011
- Published by The Electrochemical Society in Electrochemical and Solid-State Letters
- Vol. 14 (2) , B30-B33
Open AccessStart-Stop Phenomena in Channel and Land Areas of a Polymer Electrolyte Fuel Cell
This work proves that the reverse-current phenomenon occurs in polymer electrolyte fuel cells even in small regions of channels and lands on a length scale of fractions of a millimeter. The effect of the flow field design, proposed mitigation strategies, and operation conditions are evaluated by using submillimeter resolved current distribution measurements during start-up and shutdown experiments. The results demonstrate that a high gas flow rate and a short fuel gas introduction time cannot avoid mass transport limitations underneath the ribs, which cause temporarily an inhomogeneous gas distribution over the fuel electrode and in-plane current transients in the lateral direction.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (3) , B343-B348
Locally Resolved Electrochemical Impedance Spectroscopy in Channel and Land Areas of a Differential Polymer Electrolyte Fuel Cell
The effect of oxygen depletion underneath the ribs of a polymer electrolyte fuel cell (PEFC) air cathode on the impedance response is evaluated by using locally resolved electrochemical impedance spectroscopy (EIS) in channel and land areas of a differential H2H2 /air PEFC with submillimeter resolution as well as two-dimensional impedance modeling. At a higher cell polarization, we observed a strong increase of the integral cell impedance toward higher cell current. Our results demonstrate that this phenomenon is primarily a consequence of oxygen depletion underneath the ribs, while the contribution of the channel region is of minor importance. This underlines that the use of small active area PEFCs in EIS measurements does not generally justify a one-dimensional treatment of data by using through the membrane electrode assembly impedance models, even if these cells are operated at high gas flow rates. In differential cells, only the channel center can be regarded as a quasi one-dimensional cell. The contribution of in plane processes to PEFC impedance response must be seriously taken into account. Simply focusing on through plane processes runs the risk of considering the wrong phenomena and can lead to wrong conclusions.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (3) , B343-B348
Locally Resolved Electrochemical Impedance Spectroscopy in Channel and Land Areas of a Differential Polymer Electrolyte Fuel Cell
The effect of oxygen depletion underneath the ribs of a polymer electrolyte fuel cell (PEFC) air cathode on the impedance response is evaluated by using locally resolved electrochemical impedance spectroscopy (EIS) in channel and land areas of a differential H2H2 /air PEFC with submillimeter resolution as well as two-dimensional impedance modeling. At a higher cell polarization, we observed a strong increase of the integral cell impedance toward higher cell current. Our results demonstrate that this phenomenon is primarily a consequence of oxygen depletion underneath the ribs, while the contribution of the channel region is of minor importance. This underlines that the use of small active area PEFCs in EIS measurements does not generally justify a one-dimensional treatment of data by using through the membrane electrode assembly impedance models, even if these cells are operated at high gas flow rates. In differential cells, only the channel center can be regarded as a quasi one-dimensional cell. The contribution of in plane processes to PEFC impedance response must be seriously taken into account. Simply focusing on through plane processes runs the risk of considering the wrong phenomena and can lead to wrong conclusions.
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (3) , B338-B341
A Segmented Microstructured Flow Field Approach for Submillimeter Resolved Local Current Measurement in Channel and Land Areas of a PEFC
A method for the direct measurement of the local cell current with submillimeter resolution in polymer electrolyte fuel cells (PEFCs) is presented. The approach employs a segmented microstructured flow field at the anode, which is operated in differential cross-flow mode. Therefore, the anode acts as a quasi-homogeneous counter electrode. Due to the segmentation, the direct measurement of the local cell current with a high spatial resolution of in channel and land areas of the cathode flow field becomes possible. The potential of the method is demonstrated here in submillimeter-resolved local current density and local cyclic voltammetry measurements. The results clearly show that effects, which occur due to inhomogeneous operation of PEFCs in the down-the-channel direction on the length scale of tenths of centimeters, have their counterparts in the perpendicular-to-the-flow-channel direction on the millimeter scale of channel and lands and, hence, must be considered with equal attention.
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (3) , B338-B341
A Segmented Microstructured Flow Field Approach for Submillimeter Resolved Local Current Measurement in Channel and Land Areas of a PEFC
A method for the direct measurement of the local cell current with submillimeter resolution in polymer electrolyte fuel cells (PEFCs) is presented. The approach employs a segmented microstructured flow field at the anode, which is operated in differential cross-flow mode. Therefore, the anode acts as a quasi-homogeneous counter electrode. Due to the segmentation, the direct measurement of the local cell current with a high spatial resolution of in channel and land areas of the cathode flow field becomes possible. The potential of the method is demonstrated here in submillimeter-resolved local current density and local cyclic voltammetry measurements. The results clearly show that effects, which occur due to inhomogeneous operation of PEFCs in the down-the-channel direction on the length scale of tenths of centimeters, have their counterparts in the perpendicular-to-the-flow-channel direction on the millimeter scale of channel and lands and, hence, must be considered with equal attention.
- 1 January 2008
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 155 (8) , B783-B792
Impedance Response of the Proton Exchange Membrane in Polymer Electrolyte Fuel Cells
The characteristics of the impedance response of a Nafion 112 membrane in an operating polymer electrolyte fuel cell (PEFC) were investigated under subsaturated and fully humidified operation conditions using current step and ac impedance measurements in combination with high time resolution–high frequency resistance (HFR) measurements. The impedance as obtained from HFR measurements shows the behavior of a pure resistor only under fully humidified conditions. At low humidity, the impedance spectrum exhibits an inductive loop at low modulation frequencies below 1Hz1Hz . The formation of this loop is associated with the slow uptake and release of water by the bulk of the solid polymer electrolyte with ac current. The results show that the appearance of a low-frequency inductive loop in the impedance spectrum of a low-humidity PEFC is essentially the result of this effect and, therefore, indicative of a limitation of cell performance by the hydration of the ionomer by the product water formed at the cathode. This effect must be taken into account when interpreting low-frequency inductive loops in PEFC impedance spectra, in addition to other explanations proposed in the literature, which have primarily focused on reaction steps in the oxygen reduction reaction and platinum oxidation/dissolution.
- 1 January 2008
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 155 (8) , B783-B792
Impedance Response of the Proton Exchange Membrane in Polymer Electrolyte Fuel Cells
The characteristics of the impedance response of a Nafion 112 membrane in an operating polymer electrolyte fuel cell (PEFC) were investigated under subsaturated and fully humidified operation conditions using current step and ac impedance measurements in combination with high time resolution–high frequency resistance (HFR) measurements. The impedance as obtained from HFR measurements shows the behavior of a pure resistor only under fully humidified conditions. At low humidity, the impedance spectrum exhibits an inductive loop at low modulation frequencies below 1Hz1Hz . The formation of this loop is associated with the slow uptake and release of water by the bulk of the solid polymer electrolyte with ac current. The results show that the appearance of a low-frequency inductive loop in the impedance spectrum of a low-humidity PEFC is essentially the result of this effect and, therefore, indicative of a limitation of cell performance by the hydration of the ionomer by the product water formed at the cathode. This effect must be taken into account when interpreting low-frequency inductive loops in PEFC impedance spectra, in addition to other explanations proposed in the literature, which have primarily focused on reaction steps in the oxygen reduction reaction and platinum oxidation/dissolution.
- 31 July 2007
- Published by Elsevier in Electrochemistry Communications
- Vol. 9 (7) , 1607-1612
Effect of inert gas flow on hydrogen underpotential deposition measurements in polymer electrolyte fuel cells
- 31 July 2007
- Published by Elsevier in Electrochemistry Communications
- Vol. 9 (7) , 1607-1612
Effect of inert gas flow on hydrogen underpotential deposition measurements in polymer electrolyte fuel cells
- 1 January 2007
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 154 (8) , B770-B782
Oscillations in Gas Channels
The effect of oxygen depletion along the cathode flow channels on the local impedance response of a polymer electrolyte fuel cell (PEFC) operated on air and pure hydrogen was investigated using a novel experimental approach. The method combines the use of sectioned electrodes and local ac measurements in PEFCs. The results shown here give experimental proof that oxygen concentration oscillations in the cathode gas channels generated as a consequence of ac current flow evoke the formation of a low frequency capacitive loop in local H2H2 /air-PEFC impedance spectra in downstream parts of the flow field. The loop shows positive or negative real parts at low frequencies depending on the air stoichiometry. The loop is not observed in the local spectrum when the ac current is applied locally and, consequently, the impact of upstream processes on the local impedance response is excluded. A mechanistic description of the processes occurring during ac measurements in H2H2 /air-PEFCs was developed and validated by experiments. The results show that processes occurring along the flow channels of a PEFC cannot be excluded from the interpretation of PEFC impedance spectra even at rather high air stoichiometries and are in fact the most important phenomena at low modulation frequencies (fmod<10Hz)(fmod<10Hz) .
- 1 January 2007
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 154 (8) , B770-B782
Oscillations in Gas Channels
The effect of oxygen depletion along the cathode flow channels on the local impedance response of a polymer electrolyte fuel cell (PEFC) operated on air and pure hydrogen was investigated using a novel experimental approach. The method combines the use of sectioned electrodes and local ac measurements in PEFCs. The results shown here give experimental proof that oxygen concentration oscillations in the cathode gas channels generated as a consequence of ac current flow evoke the formation of a low frequency capacitive loop in local H2H2 /air-PEFC impedance spectra in downstream parts of the flow field. The loop shows positive or negative real parts at low frequencies depending on the air stoichiometry. The loop is not observed in the local spectrum when the ac current is applied locally and, consequently, the impact of upstream processes on the local impedance response is excluded. A mechanistic description of the processes occurring during ac measurements in H2H2 /air-PEFCs was developed and validated by experiments. The results show that processes occurring along the flow channels of a PEFC cannot be excluded from the interpretation of PEFC impedance spectra even at rather high air stoichiometries and are in fact the most important phenomena at low modulation frequencies (fmod<10Hz)(fmod<10Hz) .