Philippe Leproux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Philippe Leproux has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Hideaki Kano
Keio University
10 shared publications Vincent Couderc
Institut de Recherche XLIM, Limoges, FRANCE
9 shared publicationsHideaki Kano
Faculty of Science and Technology Keio University Yokohama Kanagawa Japan
5 shared publications- Vincent Couderc
University of Limoges
4 shared publications - Akihito Inoko
Department of Pathology, Aichi Medical University School of Medicine, Nagakute, Japan
3 shared publications - Alessandro Tonello
Université de Limoges
3 shared publications
Latest Publications
- Open Access
- 28 January 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (9) , 933-938
CMOS and CCD Detection in Raman Spectroscopy: A Comparison Using Spontaneous and Multiplex Coherent Anti‐Stokes Raman Scattering (CARS)
Cooled CCD cameras are used widely in spectroscopy, mainly due to their sensitivity, low noise under low‐light conditions, and relatively high image and spectral readout rates. Despite their many advantages, CCD cameras have limitations. Particularly under bright‐light conditions, such as those encountered with coherent Raman spectroscopies, the finite readout time of CCD chips becomes limiting. Furthermore, when weak signals need to be observed close to intense signals, blooming and smearing limit the signal‐to‐noise ratios achievable. Scientific complementary mixed oxide (sCMOS)–based sensors are relatively new. Although they still show much higher readout noise than cooled CCDs, their application to spectroscopy is of interest given the higher readout rates and dynamic ranges possible. Here, we evaluate sCMOS sensors for multiplex (50 ps) CARS and spontaneous Raman spectroscopy, making a direct comparison with a state‐of‐the‐art EM‐CCD detector. The EM‐CCD camera outperforms the sCMOS camera in terms of limits of detection, while the sCMOS camera performs better than the CCD in terms of dynamic range and readout rate. Importantly, an sCMOS camera does not suffer from interference due to blooming and smearing seen with CCD cameras, which enables observation of weak bands (e.g., Raman overtones) close to much more intense signals. Here, we show that, at readout rates > 20–50 Hz, the performances of the two detector types are not substantially different. We anticipate that sCMOS‐based cameras will find application for bright spectroscopies, such as multiplex CARS, as well as spontaneous Raman spectroscopy and Raman spectral imaging.
- 28 January 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 56 (9) , 933-938
Open AccessCMOS and CCD Detection in Raman Spectroscopy: A Comparison Using Spontaneous and Multiplex Coherent Anti‐Stokes Raman Scattering (CARS)
Cooled CCD cameras are used widely in spectroscopy, mainly due to their sensitivity, low noise under low‐light conditions, and relatively high image and spectral readout rates. Despite their many advantages, CCD cameras have limitations. Particularly under bright‐light conditions, such as those encountered with coherent Raman spectroscopies, the finite readout time of CCD chips becomes limiting. Furthermore, when weak signals need to be observed close to intense signals, blooming and smearing limit the signal‐to‐noise ratios achievable. Scientific complementary mixed oxide (sCMOS)–based sensors are relatively new. Although they still show much higher readout noise than cooled CCDs, their application to spectroscopy is of interest given the higher readout rates and dynamic ranges possible. Here, we evaluate sCMOS sensors for multiplex (50 ps) CARS and spontaneous Raman spectroscopy, making a direct comparison with a state‐of‐the‐art EM‐CCD detector. The EM‐CCD camera outperforms the sCMOS camera in terms of limits of detection, while the sCMOS camera performs better than the CCD in terms of dynamic range and readout rate. Importantly, an sCMOS camera does not suffer from interference due to blooming and smearing seen with CCD cameras, which enables observation of weak bands (e.g., Raman overtones) close to much more intense signals. Here, we show that, at readout rates > 20–50 Hz, the performances of the two detector types are not substantially different. We anticipate that sCMOS‐based cameras will find application for bright spectroscopies, such as multiplex CARS, as well as spontaneous Raman spectroscopy and Raman spectral imaging.
- Open Access
- 11 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Coherent Raman microscopy visualizes ongoing cellular senescence through amide I peak shifts originating from β sheets in disordered nucleolar proteins
Cellular senescence occurs through the accumulation of many kinds of stresses. Senescent cells in tissues also cause various age-related disorders. Therefore, detecting them without labeling is beneficial for medical research and developing diagnostic methods. However, existing biomarkers have limitations of requiring fixation and labeling, or their molecular backgrounds are uncertain. Coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging is a novel option because it can assess and visualize molecular structures based on their molecular fingerprint. Here, we present a new label-free method to visualize cellular senescence using CARS imaging in nucleoli. We found the peak of the nucleolar amide I band shifted to a higher wavenumber in binuclear senescent cells, which reflects changes in the protein secondary structure from predominant α-helices to β-sheets originating from amyloid-like aggregates. Following this, we developed a procedure that can visualize the senescent cells by providing the ratios and subtractions of these two components. We also confirmed that the procedure can visualize nucleolar aggregates due to unfolded/misfolded proteins produced by proteasome inhibition. Finally, we found that this method can help visualize the nucleolar defects in naïve cells even before binucleation. Thus, our method is beneficial to evaluate ongoing cellular senescence through label-free imaging of nucleolar defects.
- 11 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessCoherent Raman microscopy visualizes ongoing cellular senescence through amide I peak shifts originating from β sheets in disordered nucleolar proteins
Cellular senescence occurs through the accumulation of many kinds of stresses. Senescent cells in tissues also cause various age-related disorders. Therefore, detecting them without labeling is beneficial for medical research and developing diagnostic methods. However, existing biomarkers have limitations of requiring fixation and labeling, or their molecular backgrounds are uncertain. Coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging is a novel option because it can assess and visualize molecular structures based on their molecular fingerprint. Here, we present a new label-free method to visualize cellular senescence using CARS imaging in nucleoli. We found the peak of the nucleolar amide I band shifted to a higher wavenumber in binuclear senescent cells, which reflects changes in the protein secondary structure from predominant α-helices to β-sheets originating from amyloid-like aggregates. Following this, we developed a procedure that can visualize the senescent cells by providing the ratios and subtractions of these two components. We also confirmed that the procedure can visualize nucleolar aggregates due to unfolded/misfolded proteins produced by proteasome inhibition. Finally, we found that this method can help visualize the nucleolar defects in naïve cells even before binucleation. Thus, our method is beneficial to evaluate ongoing cellular senescence through label-free imaging of nucleolar defects.
- Open Access
- 16 September 2024
- Published by American Chemical Society (ACS) in ChemRxiv
CMOS and CCD detection in Raman spectroscopy: a comparison using spontaneous and multiplex coherent anti-Stokes Raman scattering (CARS)
Cooled CCD cameras are used widely in spectroscopy, mainly due to their sensitivity and low noise operating under low light conditions, and relatively high image and spectral readout rates. Despite their many advantages, CCD cameras have limitations. Particularly under bright light conditions, such as those encountered with coherent Raman spectroscopies, where the finite readout time of CCD chips is limiting. Furthermore, where weak signals need to be observed close to intense signals, blooming and smearing limit the signal to noise ratios achievable. Scientific complementary mixed oxide (sCMOS) based sensors are relatively new. Although they still show much higher readout noise than cooled CCDs, their application to spectroscopy is certainly of interest given the higher readout rates, and dynamic ranges possible. Here, we evaluate sCMOS sensors for specific spectroscopic applications, including multiplex (50 picosecond) CARS and spontaneous Raman spectroscopy. We compare the performance of a sCMOS based camera to a state-of-the-art (EM)CCD detector for these applications. The EMCCD camera outperforms the sCMOS camera in terms of limits of detection, while the sCMOS camera performs better than the CCD in terms of dynamic range and readout rate. Importantly, sCMOS camera does not suffer from interference due to blooming and smearing seen with CCD cameras, which enables observation of weak bands (e.g., Raman overtones) close to much more intense signals. Here we show that, at moderate readout rates, the relative performances of the two detector types are not substantially different. We anticipate that sCMOS based cameras will find application for bright spectroscopies, such as multiplex CARS, as well as spontaneous Raman spectroscopy, and Raman spectral imaging.
- 16 September 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessCMOS and CCD detection in Raman spectroscopy: a comparison using spontaneous and multiplex coherent anti-Stokes Raman scattering (CARS)
Cooled CCD cameras are used widely in spectroscopy, mainly due to their sensitivity and low noise operating under low light conditions, and relatively high image and spectral readout rates. Despite their many advantages, CCD cameras have limitations. Particularly under bright light conditions, such as those encountered with coherent Raman spectroscopies, where the finite readout time of CCD chips is limiting. Furthermore, where weak signals need to be observed close to intense signals, blooming and smearing limit the signal to noise ratios achievable. Scientific complementary mixed oxide (sCMOS) based sensors are relatively new. Although they still show much higher readout noise than cooled CCDs, their application to spectroscopy is certainly of interest given the higher readout rates, and dynamic ranges possible. Here, we evaluate sCMOS sensors for specific spectroscopic applications, including multiplex (50 picosecond) CARS and spontaneous Raman spectroscopy. We compare the performance of a sCMOS based camera to a state-of-the-art (EM)CCD detector for these applications. The EMCCD camera outperforms the sCMOS camera in terms of limits of detection, while the sCMOS camera performs better than the CCD in terms of dynamic range and readout rate. Importantly, sCMOS camera does not suffer from interference due to blooming and smearing seen with CCD cameras, which enables observation of weak bands (e.g., Raman overtones) close to much more intense signals. Here we show that, at moderate readout rates, the relative performances of the two detector types are not substantially different. We anticipate that sCMOS based cameras will find application for bright spectroscopies, such as multiplex CARS, as well as spontaneous Raman spectroscopy, and Raman spectral imaging.
- Open Access
- 1 September 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (9) , 092001
Intracellular vacuoles induced by hypo-osmotic stress visualized by coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging
We analyzed the effects of a hypo-osmotic environment on rat Schwann cells, a type of glial cell surrounding neurons, using ultra-broadband multiplex coherent anti-Stokes Raman scattering (CARS) microscopy. After hypo-osmotic treatment, we detected vacuole-like components in the cytoplasm using both bright-field and CARS spectroscopic imaging. An approach integrating both morphological examination and a spectroscopic analysis based on multiple vibrational bands revealed that these structures are predominantly water-filled, and their characteristics closely resembled those of the vacuoles observed in plant cells.
- 1 September 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (9) , 092001
Open AccessIntracellular vacuoles induced by hypo-osmotic stress visualized by coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging
We analyzed the effects of a hypo-osmotic environment on rat Schwann cells, a type of glial cell surrounding neurons, using ultra-broadband multiplex coherent anti-Stokes Raman scattering (CARS) microscopy. After hypo-osmotic treatment, we detected vacuole-like components in the cytoplasm using both bright-field and CARS spectroscopic imaging. An approach integrating both morphological examination and a spectroscopic analysis based on multiple vibrational bands revealed that these structures are predominantly water-filled, and their characteristics closely resembled those of the vacuoles observed in plant cells.
- Open Access
Coherent Raman microscopy detects nucleolar defects through amide I peak shifts originating from β-sheets: an application to visualizing ongoing cellular senescence
Cellular senescence occurs through the accumulation of many kinds of stresses. Senescent cells in tissues also cause various age-related disorders. Therefore, detecting them without labeling is beneficial. However, existing biomarkers have limitations of requiring fixation and labeling, or their molecular backgrounds are uncertain. Coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging is a novel option because it can assess and visualize molecular structures based on their molecular fingerprint. Here, we present a new label-free method to visualize cellular senescence by obtaining molecular fingerprint signals in nucleoli using a CARS microspectroscopic system. We found the peak of the nucleolar amide I band shifted to a higher wavenumber in binuclear senescent cells, which reflects changes in the protein secondary structure from predominant α-helices to β-sheets originating from amyloid-like aggregates. Following this, we developed a procedure that can visualize the senescent cells by providing the ratios and subtractions of these two components. We also confirmed that the procedure can visualize nucleolar aggregates due to unfolded/misfolded proteins produced by proteasome inhibition. Finally, we found that this method can help visualize the nucleolar defects in naïve cells even before binucleation. Thus, our method is beneficial to evaluate ongoing cellular senescence through label-free imaging of nucleolar defects.
Open AccessCoherent Raman microscopy detects nucleolar defects through amide I peak shifts originating from β-sheets: an application to visualizing ongoing cellular senescence
Cellular senescence occurs through the accumulation of many kinds of stresses. Senescent cells in tissues also cause various age-related disorders. Therefore, detecting them without labeling is beneficial. However, existing biomarkers have limitations of requiring fixation and labeling, or their molecular backgrounds are uncertain. Coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging is a novel option because it can assess and visualize molecular structures based on their molecular fingerprint. Here, we present a new label-free method to visualize cellular senescence by obtaining molecular fingerprint signals in nucleoli using a CARS microspectroscopic system. We found the peak of the nucleolar amide I band shifted to a higher wavenumber in binuclear senescent cells, which reflects changes in the protein secondary structure from predominant α-helices to β-sheets originating from amyloid-like aggregates. Following this, we developed a procedure that can visualize the senescent cells by providing the ratios and subtractions of these two components. We also confirmed that the procedure can visualize nucleolar aggregates due to unfolded/misfolded proteins produced by proteasome inhibition. Finally, we found that this method can help visualize the nucleolar defects in naïve cells even before binucleation. Thus, our method is beneficial to evaluate ongoing cellular senescence through label-free imaging of nucleolar defects.
- Open Access
- 16 August 2022
- Published by Frontiers Media SA in Frontiers in Cell and Developmental Biology
- Vol. 10, 933897
Coherent anti-Stokes Raman scattering cell imaging and segmentation with unsupervised data analysis
Coherent Raman imaging has been extensively applied to live-cell imaging in the last 2 decades, allowing to probe the intracellular lipid, protein, nucleic acid, and water content with a high-acquisition rate and sensitivity. In this context, multiplex coherent anti-Stokes Raman scattering (MCARS) microspectroscopy using sub-nanosecond laser pulses is now recognized as a mature and straightforward technology for label-free bioimaging, offering the high spectral resolution of conventional Raman spectroscopy with reduced acquisition time. Here, we introduce the combination of the MCARS imaging technique with unsupervised data analysis based on multivariate curve resolution (MCR). The MCR process is implemented under the classical signal non-negativity constraint and, even more originally, under a new spatial constraint based on cell segmentation. We thus introduce a new methodology for hyperspectral cell imaging and segmentation, based on a simple, unsupervised workflow without any spectrum-to-spectrum phase retrieval computation. We first assess the robustness of our approach by considering cells of different types, namely, from the human HEK293 and murine C2C12 lines. To evaluate its applicability over a broader range, we then study HEK293 cells in different physiological states and experimental situations. Specifically, we compare an interphasic cell with a mitotic (prophase) one. We also present a comparison between a fixed cell and a living cell, in order to visualize the potential changes induced by the fixation protocol in cellular architecture. Next, with the aim of assessing more precisely the sensitivity of our approach, we study HEK293 living cells overexpressing tropomyosin-related kinase B (TrkB), a cancer-related membrane receptor, depending on the presence of its ligand, brain-derived neurotrophic factor (BDNF). Finally, the segmentation capability of the approach is evaluated in the case of a single cell and also by considering cell clusters of various sizes.
- 16 August 2022
- Published by Frontiers Media SA in Frontiers in Cell and Developmental Biology
- Vol. 10, 933897
Open AccessCoherent anti-Stokes Raman scattering cell imaging and segmentation with unsupervised data analysis
Coherent Raman imaging has been extensively applied to live-cell imaging in the last 2 decades, allowing to probe the intracellular lipid, protein, nucleic acid, and water content with a high-acquisition rate and sensitivity. In this context, multiplex coherent anti-Stokes Raman scattering (MCARS) microspectroscopy using sub-nanosecond laser pulses is now recognized as a mature and straightforward technology for label-free bioimaging, offering the high spectral resolution of conventional Raman spectroscopy with reduced acquisition time. Here, we introduce the combination of the MCARS imaging technique with unsupervised data analysis based on multivariate curve resolution (MCR). The MCR process is implemented under the classical signal non-negativity constraint and, even more originally, under a new spatial constraint based on cell segmentation. We thus introduce a new methodology for hyperspectral cell imaging and segmentation, based on a simple, unsupervised workflow without any spectrum-to-spectrum phase retrieval computation. We first assess the robustness of our approach by considering cells of different types, namely, from the human HEK293 and murine C2C12 lines. To evaluate its applicability over a broader range, we then study HEK293 cells in different physiological states and experimental situations. Specifically, we compare an interphasic cell with a mitotic (prophase) one. We also present a comparison between a fixed cell and a living cell, in order to visualize the potential changes induced by the fixation protocol in cellular architecture. Next, with the aim of assessing more precisely the sensitivity of our approach, we study HEK293 living cells overexpressing tropomyosin-related kinase B (TrkB), a cancer-related membrane receptor, depending on the presence of its ligand, brain-derived neurotrophic factor (BDNF). Finally, the segmentation capability of the approach is evaluated in the case of a single cell and also by considering cell clusters of various sizes.
- 23 September 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 155 (12) , 125102
Visualization of intracellular lipid metabolism in brown adipocytes by time-lapse ultra-multiplex CARS microspectroscopy with an onstage incubator
We visualized a dynamic process of fatty acid uptake of brown adipocytes using a time-lapse ultra-broadband multiplex coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging system with an onstage incubator. Combined with the deuterium labeling technique, the intracellular uptake of saturated fatty acids was traced up to 9 h, a substantial advance over the initial multiplex CARS system, with an analysis time of 80 min. Characteristic metabolic activities of brown adipocytes, such as resistance to lipid saturation, were elucidated, supporting the utility of the newly developed system.
- 23 September 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 155 (12) , 125102
Visualization of intracellular lipid metabolism in brown adipocytes by time-lapse ultra-multiplex CARS microspectroscopy with an onstage incubator
We visualized a dynamic process of fatty acid uptake of brown adipocytes using a time-lapse ultra-broadband multiplex coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging system with an onstage incubator. Combined with the deuterium labeling technique, the intracellular uptake of saturated fatty acids was traced up to 9 h, a substantial advance over the initial multiplex CARS system, with an analysis time of 80 min. Characteristic metabolic activities of brown adipocytes, such as resistance to lipid saturation, were elucidated, supporting the utility of the newly developed system.
- Open Access
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Segmentation integration in multivariate curve resolution applied to coherent anti-Stokes Raman scattering
Coherent anti-Stokes Raman scattering (CARS) is a vibrational spectroscopy method based on a coherent χ (3) nonlinear interaction between light and matter through four-wave mixing. CARS process has been extensively used as a microscopy technique in biology. However the shape of CARS spectra is generally complex because of the combination of both resonant and non-resonant contributions, which limits the development of CARS microspectroscopy applications. In this context, phase retrieval methods (PRM) like the maximum entropy method (MEM) [1] are commonly used to extract the vibrationally resonant signal, corresponding to Im[χ (3) ], and thus to provide Raman-like spectra, which are more suitable for interpretation.
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Open AccessSegmentation integration in multivariate curve resolution applied to coherent anti-Stokes Raman scattering
Coherent anti-Stokes Raman scattering (CARS) is a vibrational spectroscopy method based on a coherent χ (3) nonlinear interaction between light and matter through four-wave mixing. CARS process has been extensively used as a microscopy technique in biology. However the shape of CARS spectra is generally complex because of the combination of both resonant and non-resonant contributions, which limits the development of CARS microspectroscopy applications. In this context, phase retrieval methods (PRM) like the maximum entropy method (MEM) [1] are commonly used to extract the vibrationally resonant signal, corresponding to Im[χ (3) ], and thus to provide Raman-like spectra, which are more suitable for interpretation.
- 13 May 2021
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 52 (12) , 2572-2580
Label‐free detection of polysulfides and glycogen of Cyanidium caldarium using ultra‐multiplex coherent anti‐Stokes Raman scattering microspectroscopy
Living microalga Cyanidium caldarium was visualized using ultra‐multiplex coherent anti‐Stokes Raman scattering (CARS) microspectroscopy. The Raman band related to the SO42− ion at 982 cm−1 was detected at the peripheral part of the cells and showed a signal amplitude that was approximately threefold larger than that in the medium, indicating accumulation of SO42− ions. Depending on the incubation conditions, a broad and sharp Raman band at approximately 505 cm−1 was observed at the peripheral part and inside the cells, respectively. Based on comparison of the results with model substances, these broad and sharp bands were assigned to polysulfides and glycogen, respectively.
- 13 May 2021
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 52 (12) , 2572-2580
Label‐free detection of polysulfides and glycogen of Cyanidium caldarium using ultra‐multiplex coherent anti‐Stokes Raman scattering microspectroscopy
Living microalga Cyanidium caldarium was visualized using ultra‐multiplex coherent anti‐Stokes Raman scattering (CARS) microspectroscopy. The Raman band related to the SO42− ion at 982 cm−1 was detected at the peripheral part of the cells and showed a signal amplitude that was approximately threefold larger than that in the medium, indicating accumulation of SO42− ions. Depending on the incubation conditions, a broad and sharp Raman band at approximately 505 cm−1 was observed at the peripheral part and inside the cells, respectively. Based on comparison of the results with model substances, these broad and sharp bands were assigned to polysulfides and glycogen, respectively.
- 15 April 2020
- Published by IOP Publishing in Applied Physics Express
- Vol. 13 (5) , 052003
Photo-induced meta-stable polar conformations in polystyrene microspheres revealed by time-resolved SHG microscopy
Photo-induced second harmonic generation (SHG) was observed in centrosymmetric polystyrene (PS) microspheres using 1064-nm, sub-nanosecond laser-pulse irradiation. The SHG signal gradually increased upon stationary laser-pulse irradiation. After stopping the irradiation, the increased SHG signal disappeared in approximately 30 min. When the PS bead was irradiated by laser pulses again, the SHG signal reappeared with similar temporal behavior, which was attributed to the probable growth and contraction of meta-stable polar conformations of PS chain segments under periodic photo-thermal stimuli.
- 15 April 2020
- Published by IOP Publishing in Applied Physics Express
- Vol. 13 (5) , 052003
Photo-induced meta-stable polar conformations in polystyrene microspheres revealed by time-resolved SHG microscopy
Photo-induced second harmonic generation (SHG) was observed in centrosymmetric polystyrene (PS) microspheres using 1064-nm, sub-nanosecond laser-pulse irradiation. The SHG signal gradually increased upon stationary laser-pulse irradiation. After stopping the irradiation, the increased SHG signal disappeared in approximately 30 min. When the PS bead was irradiated by laser pulses again, the SHG signal reappeared with similar temporal behavior, which was attributed to the probable growth and contraction of meta-stable polar conformations of PS chain segments under periodic photo-thermal stimuli.