Kouhyar Tavakolian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kouhyar Tavakolian has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Bozena Kaminska
Centre for Integrative Bioengineering Research (CiBER), School of Engineering Science, Simon Fraser University, Burnaby, BC, Canada V5A 1S6
4 shared publicationsAli Vaseghi
Computational and Integrative Bio-Engineering Research laboratory (CIBER), The School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC, Canada, V5A 1S6
3 shared publications- Bozena Kaminska
School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC, V5A 1S6, Canada
2 shared publications Faranak M. Zadeh
Computational and Integrative Bio-Engineering Research laboratory (CIBER), The School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC, Canada, V5A 1S6
2 shared publicationsYindar Chuo
Computational and Integrative Bio-Engineering Research laboratory (CIBER), The School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC, Canada, V5A 1S6
2 shared publicationsA.P. Blaber
1 shared publication
Latest Publications
- Open Access
- 14 September 2017
- Published by Computing in Cardiology
Challenges in Using Seismocardiography for Blood Pressure Monitoring
- 14 September 2017
- Published by Computing in Cardiology
Open AccessChallenges in Using Seismocardiography for Blood Pressure Monitoring
- 1 August 2013
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (8) , 1133-1140
Precordial acceleration signals improve the performance of diastolic timed vibrations
This paper introduces a seismocardiography based methodology of predicting the start and the end of diastole to be used in diastolic timed vibrations (DTV), which provides non-invasive emergency treatment of acute coronary thrombosis by applying direct mechanical vibrations to the patient chest during diastole of heart cycles. It is proposed that seismocardiogram (SCG), in combination with electrocardiogram (ECG), provides a new means of diastole prediction. An accelerometer was placed on the sternum of 120 healthy participants and 22 ischemic heart patients to record precordial accelerations created by the heart. The accelerometer signal was used to extract SCG and phonocardiogram (PCG). Two independent trained experts annotated the extracted signals based on the timings of the start and end of diastole. In the ischemic heart disease population by using 15 consecutive SCG cycles, the start and end of diastole was predicted in the upcoming cycles with 95 percentile error margin of 10.7 ms and 5.8 ms, respectively. These error margins were 7.4 ms and 3.5 ms, respectively, for normal participants. The results provide that prediction of the aortic valve closure point in the SCG signal helps start the vibrator in time to cover most of the isovolumic relaxation period. Also, through prediction of the mitral valve closure point in the SCG signal, safety of the technique can be assessed through prediction of the amount of unwanted vibrations applied during the isovolumic contraction period.
- 1 August 2013
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (8) , 1133-1140
Precordial acceleration signals improve the performance of diastolic timed vibrations
This paper introduces a seismocardiography based methodology of predicting the start and the end of diastole to be used in diastolic timed vibrations (DTV), which provides non-invasive emergency treatment of acute coronary thrombosis by applying direct mechanical vibrations to the patient chest during diastole of heart cycles. It is proposed that seismocardiogram (SCG), in combination with electrocardiogram (ECG), provides a new means of diastole prediction. An accelerometer was placed on the sternum of 120 healthy participants and 22 ischemic heart patients to record precordial accelerations created by the heart. The accelerometer signal was used to extract SCG and phonocardiogram (PCG). Two independent trained experts annotated the extracted signals based on the timings of the start and end of diastole. In the ischemic heart disease population by using 15 consecutive SCG cycles, the start and end of diastole was predicted in the upcoming cycles with 95 percentile error margin of 10.7 ms and 5.8 ms, respectively. These error margins were 7.4 ms and 3.5 ms, respectively, for normal participants. The results provide that prediction of the aortic valve closure point in the SCG signal helps start the vibrator in time to cover most of the isovolumic relaxation period. Also, through prediction of the mitral valve closure point in the SCG signal, safety of the technique can be assessed through prediction of the amount of unwanted vibrations applied during the isovolumic contraction period.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 3797-3800
Seismocardiographic adjustment of diastolic timed vibrations
A seismocardiography based methodology is introduced for predicting the start and the end of diastole to be used in diastolic timed vibrations. An accelerometer was placed on the sternum of 142 participants (120 healthy and 22 ischemic heart patients) to record Seismocardiogram (SCG). It is claimed that SCG, in combination with electrocardiogram (ECG), provides a mechanism for predicting diastole. It is demonstrated that prediction of the aortic valve closure point in the SCG signal helps start the vibrator in time to cover most of the isovolumic relaxation period. Also, through prediction of the mitral valve closure point, safety of the technique can be assessed by estimation of the amount of unwanted vibrations applied during the isovolumic contraction period.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 3797-3800
Seismocardiographic adjustment of diastolic timed vibrations
A seismocardiography based methodology is introduced for predicting the start and the end of diastole to be used in diastolic timed vibrations. An accelerometer was placed on the sternum of 142 participants (120 healthy and 22 ischemic heart patients) to record Seismocardiogram (SCG). It is claimed that SCG, in combination with electrocardiogram (ECG), provides a mechanism for predicting diastole. It is demonstrated that prediction of the aortic valve closure point in the SCG signal helps start the vibrator in time to cover most of the isovolumic relaxation period. Also, through prediction of the mitral valve closure point, safety of the technique can be assessed by estimation of the amount of unwanted vibrations applied during the isovolumic contraction period.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 4275-4278
Infrasonic cardiac signals: Complementary windows to cardiovascular dynamics
New approaches to fairly old noninvasive cardiology tools, based on studying low frequency vibrations created by the heart on the body, were reviewed. These signals were divided and studied in two categories and compared in their capability for estimation of hemodynamic parameters. In particular one representative signal of each category, seismocardiogram and ultra-low frequency ballistocardiogram, were selected and compared to each other in their correspondence to physiological events behind their waves.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 4275-4278
Infrasonic cardiac signals: Complementary windows to cardiovascular dynamics
New approaches to fairly old noninvasive cardiology tools, based on studying low frequency vibrations created by the heart on the body, were reviewed. These signals were divided and studied in two categories and compared in their capability for estimation of hemodynamic parameters. In particular one representative signal of each category, seismocardiogram and ultra-low frequency ballistocardiogram, were selected and compared to each other in their correspondence to physiological events behind their waves.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
- Vol. 2009 (1094687X) , 2899-2903
Comparative analysis of three different modalities for characterization of the seismocardiogram
We introduce and compare three different modalities to study seismocardiogram (SCG) and its correlation with cardiac events. We used an accelerometer attached to the subject sternum to get a reference measure. Cardiac events were then approximately identified using echocardiography. As an alternative approximation, we used consecutive Cine-MRI images of the heart to capture cardiac movements and compared them with the experimental SCG. We also employed an anatomically accurate, finite element base electromechanical model with geometry built completely from DT-MRI to simulate a portion of the cardiac cycle as observed in the SCG signal. The preliminary results demonstrate the usability of these newly proposed methods to investigate the mechanism of SCG waves and also demonstrate the usability of echocardiograph in interpretation of these results in terms of correlating them to underlying cardiac cycle events.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
- Vol. 2009 (1094687X) , 2899-2903
Comparative analysis of three different modalities for characterization of the seismocardiogram
We introduce and compare three different modalities to study seismocardiogram (SCG) and its correlation with cardiac events. We used an accelerometer attached to the subject sternum to get a reference measure. Cardiac events were then approximately identified using echocardiography. As an alternative approximation, we used consecutive Cine-MRI images of the heart to capture cardiac movements and compared them with the experimental SCG. We also employed an anatomically accurate, finite element base electromechanical model with geometry built completely from DT-MRI to simulate a portion of the cardiac cycle as observed in the SCG signal. The preliminary results demonstrate the usability of these newly proposed methods to investigate the mechanism of SCG waves and also demonstrate the usability of echocardiograph in interpretation of these results in terms of correlating them to underlying cardiac cycle events.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 4863-4866
Radar mechanocardiography: A novel analysis of the mechanical behavior of the heart
In this paper a novel system for detection of the mechanical movement of heart, mechanocardiography (MCG), with no connection to the subject's body is presented. This signal is based on radar technology. The acquired signal is highly correlated to the acceleration-based ballistocardiograph signal (BCG) recorded directly from the sternum. It is shown that the heart and breathing rates can be reliably detected using this system.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 4863-4866
Radar mechanocardiography: A novel analysis of the mechanical behavior of the heart
In this paper a novel system for detection of the mechanical movement of heart, mechanocardiography (MCG), with no connection to the subject's body is presented. This signal is based on radar technology. The acquired signal is highly correlated to the acceleration-based ballistocardiograph signal (BCG) recorded directly from the sternum. It is shown that the heart and breathing rates can be reliably detected using this system.
- 18 June 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (7) , 771-781
Improvement of ballistocardiogram processing by inclusion of respiration information
In this paper a novel methodology for processing of a ballistocardiogram (BCG) is proposed in which the respiration signal is utilized to improve the averaging of the BCG signal and ultimately the annotation and interpretation of the signal. Previous research works filtered out the respiration signal while the novelty of the current research is that, rather than removing the respiration effect from the signal, we utilize the respiration information to improve the averaging and thus analysis and interpretation of the BCG signal in diagnosis of cardiac malfunctions. This methodology is based on our investigation that BCG cycles corresponding to the inspiration and expiration phases of the respiration cycle are different in morphology. BCG cycles corresponding to the expiration phase of respiration have been proved to be more closely related to each other when compared to cycles corresponding to inspiration, and therefore expiration cycles are better candidates to be selected for the calculation of the averaged BCG signal. The new BCG average calculated based on this methodology is then considered as the representative and a template of the BCG signal for further processing. This template can be considered as the output of a clinical BCG instrument with higher reliability and accuracy compared to the previous processing methods.
- 18 June 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (7) , 771-781
Improvement of ballistocardiogram processing by inclusion of respiration information
In this paper a novel methodology for processing of a ballistocardiogram (BCG) is proposed in which the respiration signal is utilized to improve the averaging of the BCG signal and ultimately the annotation and interpretation of the signal. Previous research works filtered out the respiration signal while the novelty of the current research is that, rather than removing the respiration effect from the signal, we utilize the respiration information to improve the averaging and thus analysis and interpretation of the BCG signal in diagnosis of cardiac malfunctions. This methodology is based on our investigation that BCG cycles corresponding to the inspiration and expiration phases of the respiration cycle are different in morphology. BCG cycles corresponding to the expiration phase of respiration have been proved to be more closely related to each other when compared to cycles corresponding to inspiration, and therefore expiration cycles are better candidates to be selected for the calculation of the averaged BCG signal. The new BCG average calculated based on this methodology is then considered as the representative and a template of the BCG signal for further processing. This template can be considered as the output of a clinical BCG instrument with higher reliability and accuracy compared to the previous processing methods.
- Open Access
- 15 May 2008
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2008, 1-5
Development of a Novel Contactless Mechanocardiograph Device
A novel method of detecting mechanical movement of the heart, Mechanocardiography (MCG), with no connection to the subject's body is presented. This measurement is based on radar technology and it has been proven through this research work that the acquired signal is highly correlated to the phonocardiograph signal and acceleration-based ballistocardiograph signal (BCG) recorded directly from the sternum. The heart rate and respiration rate have been extracted from the acquired signal as two possible physiological monitoring applications of the radar-based MCG device.
- 15 May 2008
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2008, 1-5
Open AccessDevelopment of a Novel Contactless Mechanocardiograph Device
A novel method of detecting mechanical movement of the heart, Mechanocardiography (MCG), with no connection to the subject's body is presented. This measurement is based on radar technology and it has been proven through this research work that the acquired signal is highly correlated to the phonocardiograph signal and acceleration-based ballistocardiograph signal (BCG) recorded directly from the sternum. The heart rate and respiration rate have been extracted from the acquired signal as two possible physiological monitoring applications of the radar-based MCG device.