Brett A. Cruden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Brett A. Cruden has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
M. Meyyappan
NASA Ames Research Center, Moffett Field, CA 94035, USA
4 shared publicationsSurendra P. Sharma
3 shared publicationsM. V. V. S. Rao
Plasma Research Laboratory, NASA Ames Research Center, MS 223-2, Moffett Field, California 94035
2 shared publicationsSurendra P Sharma
2 shared publications- Alexander A. Bol'SHakov
Applied Spectra, Inc., Fremont, USA
1 shared publication - Alexander A. Bol'Shakov
St. Petersburg State University
1 shared publication
Latest Publications
- Open Access
Sensor for monitoring plasma parameters
A spectrally tunable VCSEL (vertical cavity surface-emitting laser) was used as part of sensing hardware for measurements of the radial-integrated gas temperature inside an inductively coupled plasma reactor. The data were obtained by profiling the Doppler-broadened absorption of metastable Ar atoms at 763.51 nm in argon and argon/nitrogen plasmas (3, 45, and 90% N2 in Ar) at pressure 0.5-70 Pa and inductive power of 100 and 300 W. The results were compared to rotational temperature derived from the N2 emission at the (0,0) transition of the C - B system. The differences in integrated rotational and Doppler temperatures were attributed to non-uniform spatial distributions of both temperature and thermometric species (Ar* and N2*) that varied depending on conditions. A two-dimensional, two-temperature fluid plasma simulation was employed to explain these differences. This work should facilitate further development of a miniature sensor for non-intrusive acquisition of data (temperature and densities of multiple plasma species) during micro- and nano-fabrication plasma processing, thus enabling the diagnostic-assisted continuous optimization and advanced control over the processes. Such sensors would also enable tracking the origins and pathways of damaging contaminants, thereby providing real-time feedback for adjustment of processes. Our work serves as an example of how two line-of-sight integrated temperatures derived from different thermometric species make it possible to characterize the radial non-uniformity of the plasma.
Open AccessSensor for monitoring plasma parameters
A spectrally tunable VCSEL (vertical cavity surface-emitting laser) was used as part of sensing hardware for measurements of the radial-integrated gas temperature inside an inductively coupled plasma reactor. The data were obtained by profiling the Doppler-broadened absorption of metastable Ar atoms at 763.51 nm in argon and argon/nitrogen plasmas (3, 45, and 90% N2 in Ar) at pressure 0.5-70 Pa and inductive power of 100 and 300 W. The results were compared to rotational temperature derived from the N2 emission at the (0,0) transition of the C - B system. The differences in integrated rotational and Doppler temperatures were attributed to non-uniform spatial distributions of both temperature and thermometric species (Ar* and N2*) that varied depending on conditions. A two-dimensional, two-temperature fluid plasma simulation was employed to explain these differences. This work should facilitate further development of a miniature sensor for non-intrusive acquisition of data (temperature and densities of multiple plasma species) during micro- and nano-fabrication plasma processing, thus enabling the diagnostic-assisted continuous optimization and advanced control over the processes. Such sensors would also enable tracking the origins and pathways of damaging contaminants, thereby providing real-time feedback for adjustment of processes. Our work serves as an example of how two line-of-sight integrated temperatures derived from different thermometric species make it possible to characterize the radial non-uniformity of the plasma.
- 29 October 2004
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 13 (4) , 691-700
Determination of gas temperature and thermometric species in inductively coupled plasmas by emission and diode laser absorption
- 29 October 2004
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 13 (4) , 691-700
Determination of gas temperature and thermometric species in inductively coupled plasmas by emission and diode laser absorption
- 15 August 2003
- Published by Elsevier in Journal of Membrane Science
- Vol. 221 (1-2) , 47-51
Corrected equations for membrane transport characterization by manometric techniques
- 15 August 2003
- Published by Elsevier in Journal of Membrane Science
- Vol. 221 (1-2) , 47-51
Corrected equations for membrane transport characterization by manometric techniques
- 1 October 2002
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 2 (5) , 475-480
Plasma-Enhanced Chemical Vapor Deposition of Multiwalled Carbon Nanofibers
Plasma-enhanced chemical vapor deposition is used to grow vertically aligned multiwalled carbon nanofibers (MWNFs). The graphite basal planes in these nanofibers are not parallel as in nanotubes; instead they exhibit a small angle resembling a stacked cone arrangement. A parametric study with varying process parameters such as growth temperature, feedstock composition, and substrate power has been conducted, and these parameters are found to influence the growth rate, diameter, and morphology. The well-aligned MWNFs are suitable for fabricating electrode systems in sensor and device development.
- 1 October 2002
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 2 (5) , 475-480
Plasma-Enhanced Chemical Vapor Deposition of Multiwalled Carbon Nanofibers
Plasma-enhanced chemical vapor deposition is used to grow vertically aligned multiwalled carbon nanofibers (MWNFs). The graphite basal planes in these nanofibers are not parallel as in nanotubes; instead they exhibit a small angle resembling a stacked cone arrangement. A parametric study with varying process parameters such as growth temperature, feedstock composition, and substrate power has been conducted, and these parameters are found to influence the growth rate, diameter, and morphology. The well-aligned MWNFs are suitable for fabricating electrode systems in sensor and device development.
- 5 August 2002
- Published by AIP Publishing in Applied Physics Letters
- Vol. 81 (6) , 990-992
Neutral gas temperature estimate in CF4/O2/Ar inductively coupled plasmas
Neutral temperatures in inductively coupled mixture plasmas have been characterized by fitting the rotational envelope of emission spectra in a gaseous electronics conference reference cell. CF and CO are found to present different rotational temperatures with opposite trends with respect to pressure. It is proposed that CF is created as a rotationally and translationally hot molecule due to dissociation and the disparity in temperatures and temperature trend is indicative of incomplete equilibration of the CF with other neutral species in the plasma. This may have important consequences from the standpoint of understanding neutral reaction chemistries.- 5 August 2002
- Published by AIP Publishing in Applied Physics Letters
- Vol. 81 (6) , 990-992
Neutral gas temperature estimate in CF4/O2/Ar inductively coupled plasmas
Neutral temperatures in inductively coupled mixture plasmas have been characterized by fitting the rotational envelope of emission spectra in a gaseous electronics conference reference cell. CF and CO are found to present different rotational temperatures with opposite trends with respect to pressure. It is proposed that CF is created as a rotationally and translationally hot molecule due to dissociation and the disparity in temperatures and temperature trend is indicative of incomplete equilibration of the CF with other neutral species in the plasma. This may have important consequences from the standpoint of understanding neutral reaction chemistries.- 1 February 2002
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 11 (1) , 77-90
Fourier transform infrared spectroscopy of CF4plasmas in the GEC reference cell
- 1 February 2002
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 11 (1) , 77-90
Fourier transform infrared spectroscopy of CF4plasmas in the GEC reference cell
- 1 January 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (1) , 353-363
Detection of chamber conditioning by CF4 plasmas in an inductively coupled plasma reactor
During oxide etch processes, buildup of fluorocarbon residues on reactor sidewalls can cause run-to-run drift and will necessitate time for conditioning and cleaning of the reactor. Various measurements in and Ar plasmas are made in an attempt to identify a metric useable to indicate the chamber condition. Mass spectrometry and Langmuir probe data show that the buildup of fluorocarbon films on the reactor surface causes a decrease in plasma floating potential, plasma potential, and ion energy in argon plasmas. This change in floating potential is also observed in plasma operation, and occurs primarily during the first hour and a half of plasma operation. A slight rise in electron density is also observed in the argon plasmas. Because the change is seen in an argon plasma, it is indicative of altered physical, not chemical, plasma-surface interactions. Specifically, the insulating films deposited on metal surfaces alter the electromagnetic fields seen by the plasma, affecting various parameters including the floating potential and electron density. An impedance probe placed on the inductive coil shows a slight reduction in plasma impedance due to this rising electron density. The optical emission of several species, including CF, Si, and C, is also monitored for changes in density resulting from the buildup of film on the chamber wall. Changes in the optical emission spectrum are comparable to the noise levels in these measurements.- 1 January 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (1) , 353-363
Detection of chamber conditioning by CF4 plasmas in an inductively coupled plasma reactor
During oxide etch processes, buildup of fluorocarbon residues on reactor sidewalls can cause run-to-run drift and will necessitate time for conditioning and cleaning of the reactor. Various measurements in and Ar plasmas are made in an attempt to identify a metric useable to indicate the chamber condition. Mass spectrometry and Langmuir probe data show that the buildup of fluorocarbon films on the reactor surface causes a decrease in plasma floating potential, plasma potential, and ion energy in argon plasmas. This change in floating potential is also observed in plasma operation, and occurs primarily during the first hour and a half of plasma operation. A slight rise in electron density is also observed in the argon plasmas. Because the change is seen in an argon plasma, it is indicative of altered physical, not chemical, plasma-surface interactions. Specifically, the insulating films deposited on metal surfaces alter the electromagnetic fields seen by the plasma, affecting various parameters including the floating potential and electron density. An impedance probe placed on the inductive coil shows a slight reduction in plasma impedance due to this rising electron density. The optical emission of several species, including CF, Si, and C, is also monitored for changes in density resulting from the buildup of film on the chamber wall. Changes in the optical emission spectrum are comparable to the noise levels in these measurements.