Walter De Wever
Research Subjects
Walter De Wever has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Sigrid Stroobants
Department of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium
4 shared publications J. A. Verschakelen
Department of Radiology, University Hospitals Gasthuisberg, Leuven, Belgium
2 shared publicationsJ. Bogaert
University Hospitals Gasthuisberg
2 shared publicationsJ.A. Verschakelen
2 shared publicationsG. Marchal
University Hospitals Gasthuisberg
1 shared publicationJ A Verschakelen
1 shared publication
Latest Publications
- 9 June 2007
- Vol. 90 (2) , 112-9
Integrated PET/CT in lung cancer imaging: history and technical aspects.
Integrated PET/CT is a new anatomo-metabolic imaging modality combining two different techniques: Computed Tomography (CT) that provides very detailed anatomic information and Positron Emission Tomography (PET) that provides metabolic information. Integrated PET/CT has several advantages. One of the advantages is the use of CT data for attenuation correction that is significantly faster compared to that in conventional PET systems. Due to the use of CT data for attenuation correction, artefacts can be generated on PET images related to the use of intravenous or oral CT contrast agents, CT beam-hardening artefacts due to metallic implants and motion artefacts (respiratory motion, physical bowel motion, cardiac motion). The purpose of this review is to discuss some technical considerations concerning the CT protocol that can be used for PET/CT in lung cancer imaging and to give a short overview of the initial results of staging of non-small cell lung cancer (NSCLC).
- 9 June 2007
- Vol. 90 (2) , 112-9
Integrated PET/CT in lung cancer imaging: history and technical aspects.
Integrated PET/CT is a new anatomo-metabolic imaging modality combining two different techniques: Computed Tomography (CT) that provides very detailed anatomic information and Positron Emission Tomography (PET) that provides metabolic information. Integrated PET/CT has several advantages. One of the advantages is the use of CT data for attenuation correction that is significantly faster compared to that in conventional PET systems. Due to the use of CT data for attenuation correction, artefacts can be generated on PET images related to the use of intravenous or oral CT contrast agents, CT beam-hardening artefacts due to metallic implants and motion artefacts (respiratory motion, physical bowel motion, cardiac motion). The purpose of this review is to discuss some technical considerations concerning the CT protocol that can be used for PET/CT in lung cancer imaging and to give a short overview of the initial results of staging of non-small cell lung cancer (NSCLC).
- Open Access
- 1 March 2007
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 29 (5) , 995-1002
Detection of extrapulmonary lesions with integrated PET/CT in the staging of lung cancer
The aim of the present study was to assess retrospectively the additional value of positron emission tomography (PET)/computed tomography (CT) in the detection of unexpected extrapulmonary lesions in the staging of patients with a malignant pulmonary lesion in comparison with CT and PET used alone.A total of 217 patients with a pathologically proven lung tumour underwent PET/CT. CT, PET and PET/CT were evaluated in the detection of extrapulmonary lesions. These abnormalities were compared with the final diagnosis obtained from the medical records and statistical analysis was carried out.In total, 108 lesions were clinically detected. PET/CT showed a sensitivity, specificity, positive and negative predictive values and accuracy of 100, 81, 71, 100 and 87%, respectively, for the detection of extrapulmonary lesions and 92, 98, 89, 98 and 97%, respectively, for the detection of malignant extrapulmonary lesions. PET/CT was significantly better than CT and PET used alone.Conventional staging work-up has a poor sensitivity in detecting second primary cancers or unexpected metastases. The detection of malignant extrapulmonary lesions is necessary for correct tumour staging. By combining both metabolic and anatomical information, positron emission tomography/computed tomography is able to depict more unexpected extrapulmonary lesions than computed tomography and positron emission tomography used alone, and positron emission tomography/computed tomography provides more additional information of malignancy or benignancy of lesions detected with one of the two imaging modalities alone.
- 1 March 2007
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 29 (5) , 995-1002
Open AccessDetection of extrapulmonary lesions with integrated PET/CT in the staging of lung cancer
The aim of the present study was to assess retrospectively the additional value of positron emission tomography (PET)/computed tomography (CT) in the detection of unexpected extrapulmonary lesions in the staging of patients with a malignant pulmonary lesion in comparison with CT and PET used alone.A total of 217 patients with a pathologically proven lung tumour underwent PET/CT. CT, PET and PET/CT were evaluated in the detection of extrapulmonary lesions. These abnormalities were compared with the final diagnosis obtained from the medical records and statistical analysis was carried out.In total, 108 lesions were clinically detected. PET/CT showed a sensitivity, specificity, positive and negative predictive values and accuracy of 100, 81, 71, 100 and 87%, respectively, for the detection of extrapulmonary lesions and 92, 98, 89, 98 and 97%, respectively, for the detection of malignant extrapulmonary lesions. PET/CT was significantly better than CT and PET used alone.Conventional staging work-up has a poor sensitivity in detecting second primary cancers or unexpected metastases. The detection of malignant extrapulmonary lesions is necessary for correct tumour staging. By combining both metabolic and anatomical information, positron emission tomography/computed tomography is able to depict more unexpected extrapulmonary lesions than computed tomography and positron emission tomography used alone, and positron emission tomography/computed tomography provides more additional information of malignancy or benignancy of lesions detected with one of the two imaging modalities alone.
- 3 October 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (2) , 467-473
Additional value of integrated PET-CT in the detection and characterization of lung metastases: correlation with CT alone and PET alone
The purpose was evaluating retrospectively the additional value of integrated positron emission tomography (PET) and computed tomography (CT) in the detection of pulmonary metastases in comparison with CT and PET alone. Fifty-six lung nodules, divided into three groups according their size, detected in 24 consecutive patients with a known primary tumor were retrospectively evaluated with integrated PET-CT, CT and PET. The nature of these nodules was determined by either histopathology or a follow-up of at least 6 months. The CT and PET images of the integrated PET-CT were evaluated separately by a radiologist and a nuclear medicine physician, the integrated PET-CT images were evaluated by a chest radiologist and nuclear medicine physician in consensus. The investigators were asked to search lung nodules and to determine whether these nodules were metastases or not. Sensitivity and accuracy for CT, PET and integrated PET-CT for characterization of all pulmonary nodules were, respectively: 100%, 90%, 100% and 57%, 55%, 55%. There was no significant difference in the characterization of pulmonary nodules between integrated PET-CT and CT alone (P=1.000) and PET alone (P=0.1306). An accurate evaluation is only possible for lesions larger than 1 cm.
- 3 October 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (2) , 467-473
Additional value of integrated PET-CT in the detection and characterization of lung metastases: correlation with CT alone and PET alone
The purpose was evaluating retrospectively the additional value of integrated positron emission tomography (PET) and computed tomography (CT) in the detection of pulmonary metastases in comparison with CT and PET alone. Fifty-six lung nodules, divided into three groups according their size, detected in 24 consecutive patients with a known primary tumor were retrospectively evaluated with integrated PET-CT, CT and PET. The nature of these nodules was determined by either histopathology or a follow-up of at least 6 months. The CT and PET images of the integrated PET-CT were evaluated separately by a radiologist and a nuclear medicine physician, the integrated PET-CT images were evaluated by a chest radiologist and nuclear medicine physician in consensus. The investigators were asked to search lung nodules and to determine whether these nodules were metastases or not. Sensitivity and accuracy for CT, PET and integrated PET-CT for characterization of all pulmonary nodules were, respectively: 100%, 90%, 100% and 57%, 55%, 55%. There was no significant difference in the characterization of pulmonary nodules between integrated PET-CT and CT alone (P=1.000) and PET alone (P=0.1306). An accurate evaluation is only possible for lesions larger than 1 cm.
- 9 May 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (1) , 23-32
Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT
Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative.
- 9 May 2006
- Published by Springer Nature in European Radiology
- Vol. 17 (1) , 23-32
Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT
Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative.
- 1 October 2005
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 26 (5) , 364-373
Virtual Bronchoscopy: Accuracy and Usefulness—An Overview
- 1 October 2005
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 26 (5) , 364-373
Virtual Bronchoscopy: Accuracy and Usefulness—An Overview
- 1 May 2004
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 23 (5) , 776-782
Multidetector CT-generated virtual bronchoscopy: an illustrated review of the potential clinical indications
Multidetector computed tomography-generated virtual bronchoscopy (VB) is a recent technical development that allows visualisation of the lumen and wall of the trachea and proximal part of the bronchial tree. A dynamic image is produced that resembles what is seen with fibreoptic bronchoscopy (FB).Although the technique has not yet reached daily clinical practice and it can never replace FB, performing VB can be useful in well-defined clinical situations.In this paper, the value and limitations of virtual bronchoscopy will be reviewed, to illustrate the potential role of virtual bronchoscopy in the evaluation of trachea and bronchial tree pathology.
- 1 May 2004
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 23 (5) , 776-782
Multidetector CT-generated virtual bronchoscopy: an illustrated review of the potential clinical indications
Multidetector computed tomography-generated virtual bronchoscopy (VB) is a recent technical development that allows visualisation of the lumen and wall of the trachea and proximal part of the bronchial tree. A dynamic image is produced that resembles what is seen with fibreoptic bronchoscopy (FB).Although the technique has not yet reached daily clinical practice and it can never replace FB, performing VB can be useful in well-defined clinical situations.In this paper, the value and limitations of virtual bronchoscopy will be reviewed, to illustrate the potential role of virtual bronchoscopy in the evaluation of trachea and bronchial tree pathology.