KTKatsuyuki Taguchi

Katsuyuki Taguchi

*This is an algorithmically generated author record based on publicly available information.

Katsuyuki Taguchi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The cause of the artifact in 4‐slice helical computed tomography

    by Katsuyuki Taguchi, Hiroshi Aradate, Yasuo Saito, Ilan Zmora, Kyung S. Han, Michael D. Silver

    The causes of the image artifacts in a 4‐slice helical computed tomography have been discussed as follows: (1) changeover in pairs of data used in z interpolation, (2) sampling interval in z, and (3) the cone angle. This study analyzes the first two causes of the artifact and describes how the current algorithm [K. Taguchi and H. Aradate, Radiology 205P, 390 (1997); 205P, 618 (1997); Med. Phys. 25, 550–561 (1998); H. Hu, ibid. 26, 5–18 (1999); S. Schaller et al., IEEE Trans. Med. Imaging 19, 822–834 (2000); K. Taguchi, Ph.D. thesis, University of Tsukuba, 2002] solves the problem. An interpolated sinogram for a slice at the edge of a ball phantom shows discontinuity caused by the changeover. If we extend the streak artifact in the reconstructed image, it crosses the focus orbit at the corresponding projection angle. Applying z filtering can reduce such causes by its feathering effect and mixing data obtained by different cone angles; the best results are provided when z filtering is applied to densely sampled helical data.


  • A new weighting scheme for cone-beam helical CT to reduce the image noise

    by Katsuyuki Taguchi, Be-Shan S Chiang, Michael D Silver

    Reducing the patient dose while keeping the image noise at the same level is desired for x-ray CT examinations. In order to achieve the goal, we propose a new weighting scheme taking the validity of the data and redundant data samples into account. The method is evaluated with a new generalized version of the Feldkamp helical reconstruction algorithm. It allows us to enlarge the projection angular range used in reconstruction, and thus, to reduce the image noise by increasing the detector utilization rate to 100% without sacrificing the image quality or z-resolution. This concept can be adapted to other exact or approximate algorithms as far as they use redundant data samples.


  • Tilted helical Feldkamp cone-beam reconstruction algorithm for multislice CT

    by Ilmar A. Hein, Katsuyuki Taguchi, Issei Mori, Masahiro Kazama, Michael D. Silver

    In many clinical applications, it is necessary to tilt the gantry of an X-ray CT system with respect to the patient. Tilting the gantry introduces no complications for single-slice fan-beam systems; however, most systems today are helical multislice systems with up to 16 slices (and this number is sure to increase in the future). The image reconstruction algorithms used in multislice helical CT systems must be modified to compensate for the tilt. If they are not, the quality of reconstructed images will be poor with the presence of significant artifacts produced by the tilt. Practical helical multislice algorithms currently incorporated in today’s systems include helical fan-beam, ASSR (Advanced single-slice rebinning), and Feldkamp algorithms. This paper presents the modifications necessary to compensate for gantry tilt for the helical cone-beam Feldkamp algorithm implemented by Toshiba (referred to as TCOT for true cone-beam tomography). Unlike some of the other algorithms, gantry tilt compensation is simple and straightforward to implement with no significant increase in computational complexity. It will be shown that the effect of the gantry tilt is to introduce a lateral shift in the isocenter of the reconstructed slice of interest, which is a function of the tilt, couch speed, and view angle. This lateral shift is easily calculated and incorporated into the backprojection algorithm. The tilt-compensated algorithm is called T-TCOT. Experimental tilted-gantry data has been obtained with 8- and 16 slice Toshiba Aquilion systems, and examples of uncompensated and tilt compensated images are presented.


  • Temporal resolution and the evaluation of candidate algorithms for four‐dimensional CT

    by Katsuyuki Taguchi

    The four‐dimensional computed tomography (“4D‐CT”) with area detector has been developed for dynamic volumetric imaging with large longitudinal coverage. In this paper one of the key technologies for 4D‐CT development is discussed: Image reconstruction algorithm with high temporal resolution. All of the cone‐beam algorithms investigated previously assume that the object is stationary. In this paper a new class of cone‐beam problem is addressed: a dynamic volumetric (4‐D) imaging. A continuously rotating circular (stationary couch) scanning is employed, and then, a generalized version of the well‐known Feldkamp algorithm with the following three steps is performed: (1) applying a weighting function (along the time axis) to projection data, (2) filtering the weighted data along the detector row direction, (3) cone‐beam backprojecting of the filtered data along the corresponding x‐ray path. The weighting function controls the time center, the temporal resolution, and the image quality. Four weighting functions developed for fan‐beam reconstruction were applied to the first step: (a) a constant weight fixed at 0.5 (FS‐FDK), (b) feathering both edges of the (time) window (OS‐FDK), (c) Parker's weight for a half‐scan (HF‐FDK), and (d) an extended Parker's weight, which allows us to use a larger range of projection data up to one rotation (NHS‐FDK). We evaluated them in terms of temporal resolution, image noise, and image quality. Also, the cause of the artifact has been investigated. The temporal resolution of NHF‐FDK equals that of HS‐FDK, which is half of the one rotation period. For the moving object, NHS‐FDK offers the best image quality. The images with FS‐FDK are degraded by streak artifacts; HS‐FDK provides poor image quality with good temporal resolution; and images by OS‐FDK are blurred due to insufficient temporal resolution. The cause of the artifact was found as an inconsistency of projection data due to object motion (in FS‐FDK) and lost 3‐D‐Radon data caused by applying Parker's weight (in HS‐FDK). A hand toy was employed for the preliminary evaluation of dynamic volumetric imaging with the real 256‐slice scanner. In an overall evaluation, NHS‐FDK provides the stable and the sufficient image quality both with moving and stationary objects.