HTHannes Tammet

Hannes Tammet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hannes Tammet has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Passage of Charged Particles Through Segmented Axial-Field Tubes

    by Hannes Tammet

    We propose a mathematical theory explaining the passage of charged aerosol particles through segmented tube mobility filters recently suggested by Bezantakos et al. A segmented tube is composed of conductive segments and semiinsulating segments, which are made of electrostatic dissipative material. Electric potential applied to a semi-insulating segment generates a uniform electric field and holds back penetration of charged particles. Analytic equations of penetration efficiency of nondiffusing particles are derived for problems, where the length of the decelerating semi-insulating section exceeds the tube diameter at least twice and the air flow profile is uniform or follows the Hagen–Poiseuille law. The equations well explain the experimental results obtained by Bezantakos et al. The requirements for the tube parameters necessary for the application of analytic equations are derived by means of a numerical model. The motion of particles in segmented tube mobility filters is illustrated with diagrams compiled using the method of numerical tracking of trajectories. Copyright 2015 American Association for Aerosol Research


  • Open Access

    Estimating neutral nanoparticle steady-state size distribution and growth according to measurements of intermediate air ions

    by H. Tammet, K. Komsaare, U. Hõrrak

    Continuous measurements of intermediate air ion size distributions were carried out in the small town Tartu, Estonia, from 1 April 2010 through 7 November 2011. The intermediate ions are charged aerosol particles of diameter 1.5–7.5 nm. In this paper we study what information about neutral nanoparticles of atmospheric aerosols can be drawn from the air ion measurements. Rough estimates of the growth rate and the size distribution of neutral nanoparticles were derived for the subset of measurements while the concentration of the intermediate ions was close to the median and remains in the range of 21 ± 2 cm−3. This criterion excludes the specific new particle formation events characterized with high concentration of intermediate ions and includes only most typical quiet periods between the events when the simultaneous growth, depletion and recharging of particles are described with steady-state equations. We estimated the growth rate of nanoparticles to be about 2 nm h−1 while the growth flux or apparent nucleation rate proved to be about 0.5 cm−3 s−1 at 3 nm and about 0.08 cm−3 s−1 at 7 nm. The results suggest that the process of new particle formation is not interrupted during the quiet periods between events of intensive nucleation of atmospheric aerosols.


  • Open Access

    Symmetric Inclined Grid Mobility Analyzer for the Measurement of Charged Clusters and Fine Nanoparticles in Atmospheric Air

    by H. Tammet

    The Symmetric Inclined Grid Mobility Analyzer (SIGMA) was developed for applications in atmospheric aerosol nucleation research with special attention to long-term routine measurements in natural atmospheric conditions. The new instrument was elaborated using the experience of the preceding scanning mobility analyzers Inclined Grid Mobility Analyzer (IGMA) and Balanced Scanning Mobility Analyzer (BSMA). The range of electric mobility is 0.032−3.2 cm2V−1s−1. The particle diameter distribution in the range of 0.4−7.5 nm is resolved considering the size-mobility correlation at air temperature and pressure measured with built-in sensors. The scanning technique ensures that possible peculiarities in the recorded size or mobility distribution are not caused by the technical troubles of individual mobility channels. High rate of air flow and isopotential principle suppress the disturbing effect of external electric fields and assure the representative sampling of air ions. The sheath air is coming from the atmosphere together with the sample air and is deionized by means of electrostatic filters. The residence time of the air in the instrument is 0.16 s and the temperature change does not exceed 0.5 K. Different of the previous instruments the positive and negative air ions are sampled from the same inlet air flow and measured exactly simultaneously. The sensitivity of the instrument is increased and allows measuring the mobility fraction concentrations of charged fine nanometer particles in atmospheric air at a standard 5-min time resolution with random errors of about 1 cm−3. The time resolution of 20 s is available at random errors of about 5 cm−3.


  • Open Access

    Negatively charged nanoparticles produced by splashing of water

    by H. Tammet, U. Hõrrak, M. Kulmala

    The production of splashing-generated balloelectric intermediate ions was studied by means of mobility spectrometry in the atmosphere during the rain and in a laboratory experiment simulating the heavy rain. The partial neutralization of intermediate ions with cluster ions generated by beta rays suppressed the space charge of intermediate ions but preserved the shape of the mobility distribution. The balloelectric ions produced from the waterworks water of high TDS (Total Dissolved Solids) had about the same mobilities as the ions produced from the rainwater of low TDS. This suggests that the balloelectric ions can be considered as singly charged water nanoparticles. By different measurements, the diameter mode of these particles was 2.2–2.7 nm, which is close to the diameter of 2.5 nm of the Chaplin's 280-molecule magic icosahedron superclusters. The measurements can be explained by a hypothesis that the pressure of saturated vapor over the nanoparticle surface is suppressed by a number of magnitudes due to the internal structure of the particles near the size of 2.5 nm. The records of the concentration bursts of balloelectric ions in the atmosphere are formally similar to the records of the nucleation bursts but they cannot be qualified as nucleation bursts because the particles are not growing but shrinking.


  • Open Access

    Factors of air ion balance in a coniferous forest according to measurements in Hyytiälä, Finland

    by H. Tammet, U. Hõrrak, L. Laakso, M. Kulmala

    A new mathematical model describing air ion balance was developed and tested. It has improved approximations and includes dry deposition of ions onto the forest canopy. The model leads to an explicit algebraic solution of the balance equations. This allows simple calculation of both the ionization rate and the average charge of aerosol particles from measurements of air ions and aerosol particles, with some parameters of the forest. Charged aerosol particles are distinguished from cluster ions by their size, which exceeds 1.6 nm diameter. The relative uncertainty of the ionization rate is about the same or less than the relative uncertainties of the measurements. The model was tested with specific air ion measurements carried out simultaneously at two heights at the Hyytiälä forest station, Finland. Earlier studies have shown a difference in the predictions of the ionization rate in the Hyytiälä forest when calculated in two different ways: based on the measurements of the environmental radioactivity and based on the air ion and aerosol measurements. The new model explains the difference as a consequence of neglecting dry deposition of ions in the earlier models. The ionization rate during the 16 h campaign was 5.6±0.8 cm−3 s−1 at the height of 2 m and 3.9±0.2 cm−3 s−1 at the height of 14 m, between the tops of the trees. The difference points out the necessity to consider the height variation when the ionization rate is used as a parameter in studies of ion-induced nucleation. Additional results are some estimates of the parameters of air ion balance. The recombination sink of cluster ions on the ions of opposite polarity made up 9–13%, the sink on aerosol particles 65–69%, and the sink on forest canopy 18–26% of the total sink of cluster ions. The average lifetime of cluster ions was about 130 s for positive and about 110 s for negative ions. At the height of 2 m, about 70% of the space charge of air was carried by aerosol particles, and at the height of 14 m, about 84%.