Geetha Bhat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Geetha Bhat has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Antone Tatooles
Advocate Christ Medical Center, Oak Lawn, Illinois
12 shared publications Antone Tatooles
From the Center for Heart Transplant and Assist Devices, Heart and Vascular Institute Administration, Oak Lawn, Illinois
11 shared publicationsGardner Yost
From the Center for Heart Transplant and Assist Devices, Heart and Vascular Institute Administration, Oak Lawn, Illinois
10 shared publicationsSunil Pauwaa
10 shared publicationsAshim Aggarwal
9 shared publications- Gardner Yost
Center for Heart Transplant and Assist Devices, Outpatient Pavilion, H&V Administration, Advocate Christ Medical Center, 6th Floor, 4440 West 95th Street, Oak Lawn, IL, 60453, USA.
7 shared publications
Latest Publications
- 1 February 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (2) , 148-151
Postoperative B-Type Natriuretic Peptide as Predictor for Postoperative Outcomes in Patients Implanted With Left Ventricular Assist Devices
B-type natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (preoperative minus postoperative [ΔBNP] = −693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.
- 1 February 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (2) , 148-151
Postoperative B-Type Natriuretic Peptide as Predictor for Postoperative Outcomes in Patients Implanted With Left Ventricular Assist Devices
B-type natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (preoperative minus postoperative [ΔBNP] = −693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.
- 5 July 2018
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 41 (8) , 445-451
Risk stratification with longitudinal neutrophil to lymphocyte ratio assessment after left ventricular assist device implantation
Inflammatory processes are well-characterized risk factors in cardiovascular disease including advanced heart failure. Previous studies have utilized individual white cell subtypes in risk analysis, and a recent study has focused on the efficacy of the neutrophil-to-lymphocyte ratio in evaluating negative outcomes following left ventricular assist device implantation. To investigate the interaction between the left ventricular assist device and white cell counts, we assessed longitudinal changes in neutrophil-to-lymphocyte ratio following left ventricular assist device implantation. This retrospective study included 100 patients who underwent left ventricular assist device implantation between 2012 and 2013. The neutrophil-to-lymphocyte ratio was calculated prior to left ventricular assist device implantation, daily for the first 30 postoperative days, and at the first two postoperative outpatient visits. Preoperative demographic and clinical data were collected for all patients. The mean neutrophil-to-lymphocyte ratio immediately before left ventricular assist device implantation was 5.2 ± 4.9. After surgery, the neutrophil-to-lymphocyte ratio decreased asymptotically, from a peak of 29.2 on postoperative day 1 to 4.1 at the second outpatient visit (p < 0.001). Lack of improvement in the neutrophil-to-lymphocyte ratio at postoperative day 10 was associated with increased length of stay, right heart failure, and a trend toward worsened survival. Our results indicate a significant inflammatory response to implantation of the left ventricular assist device, a known effect. The magnitude of this response may be effectively and easily monitored over time using the neutrophil-to-lymphocyte ratio. In general, approximately 30 days is required for the neutrophil-to-lymphocyte ratio to return to preoperative levels. After several months, the neutrophil-to-lymphocyte ratio improves to below preoperative levels. It is possible that this reduction reflects the reversal of various heart failure–mediated inflammatory processes following left ventricular assist device implantation.
- 5 July 2018
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 41 (8) , 445-451
Risk stratification with longitudinal neutrophil to lymphocyte ratio assessment after left ventricular assist device implantation
Inflammatory processes are well-characterized risk factors in cardiovascular disease including advanced heart failure. Previous studies have utilized individual white cell subtypes in risk analysis, and a recent study has focused on the efficacy of the neutrophil-to-lymphocyte ratio in evaluating negative outcomes following left ventricular assist device implantation. To investigate the interaction between the left ventricular assist device and white cell counts, we assessed longitudinal changes in neutrophil-to-lymphocyte ratio following left ventricular assist device implantation. This retrospective study included 100 patients who underwent left ventricular assist device implantation between 2012 and 2013. The neutrophil-to-lymphocyte ratio was calculated prior to left ventricular assist device implantation, daily for the first 30 postoperative days, and at the first two postoperative outpatient visits. Preoperative demographic and clinical data were collected for all patients. The mean neutrophil-to-lymphocyte ratio immediately before left ventricular assist device implantation was 5.2 ± 4.9. After surgery, the neutrophil-to-lymphocyte ratio decreased asymptotically, from a peak of 29.2 on postoperative day 1 to 4.1 at the second outpatient visit (p < 0.001). Lack of improvement in the neutrophil-to-lymphocyte ratio at postoperative day 10 was associated with increased length of stay, right heart failure, and a trend toward worsened survival. Our results indicate a significant inflammatory response to implantation of the left ventricular assist device, a known effect. The magnitude of this response may be effectively and easily monitored over time using the neutrophil-to-lymphocyte ratio. In general, approximately 30 days is required for the neutrophil-to-lymphocyte ratio to return to preoperative levels. After several months, the neutrophil-to-lymphocyte ratio improves to below preoperative levels. It is possible that this reduction reflects the reversal of various heart failure–mediated inflammatory processes following left ventricular assist device implantation.
- 27 April 2018
- Published by SAGE Publications in Perfusion
- Vol. 33 (7) , 562-567
The neutrophil to lymphocyte ratio in patients supported with extracorporeal membrane oxygenation
Introduction: The neutrophil to lymphocyte ratio (NLR) has proven to be a robust predictor of mortality in a wide range of cardiovascular diseases. This study investigated the predictive value of the NLR in patients supported by extracorporeal membrane oxygenation (ECMO) systems. Methods: This study included 107 patients who underwent ECMO implantation for cardiogenic shock. Median preoperative NLR was used to divide the cohort, with Group 1 NLR <14.2 and Group 2 with NLR ≥14.2. Survival, the primary outcome, was compared between groups. Results: The study cohort was composed of 64 (60%) males with an average age 53.1 ± 14.9 years. Patients in Group 1 had an average NLR of 7.5 ± 3.5 compared to 27.1 ± 19.9 in Group 2. Additionally, those in Group 2 had significantly higher preoperative blood urea nitrogen (BUN) and age. Survival analysis indicated a thirty-day survival of 56.2%, with significantly worsened mortality in patients with NLR greater than 14.2, p=0.047. Discussion: Our study shows the NLR has prognostic value in patients undergoing ECMO implantation. Leukocytes are known contributors to myocardial damage and neutrophil infiltration is associated with damage caused by myocardial ischemia.
- 27 April 2018
- Published by SAGE Publications in Perfusion
- Vol. 33 (7) , 562-567
The neutrophil to lymphocyte ratio in patients supported with extracorporeal membrane oxygenation
Introduction: The neutrophil to lymphocyte ratio (NLR) has proven to be a robust predictor of mortality in a wide range of cardiovascular diseases. This study investigated the predictive value of the NLR in patients supported by extracorporeal membrane oxygenation (ECMO) systems. Methods: This study included 107 patients who underwent ECMO implantation for cardiogenic shock. Median preoperative NLR was used to divide the cohort, with Group 1 NLR <14.2 and Group 2 with NLR ≥14.2. Survival, the primary outcome, was compared between groups. Results: The study cohort was composed of 64 (60%) males with an average age 53.1 ± 14.9 years. Patients in Group 1 had an average NLR of 7.5 ± 3.5 compared to 27.1 ± 19.9 in Group 2. Additionally, those in Group 2 had significantly higher preoperative blood urea nitrogen (BUN) and age. Survival analysis indicated a thirty-day survival of 56.2%, with significantly worsened mortality in patients with NLR greater than 14.2, p=0.047. Discussion: Our study shows the NLR has prognostic value in patients undergoing ECMO implantation. Leukocytes are known contributors to myocardial damage and neutrophil infiltration is associated with damage caused by myocardial ischemia.
- 30 March 2018
- Published by Wiley in Nutrition in Clinical Practice
- Vol. 33 (6) , 825-830
Effect of Vitamin D Level on Clinical Outcomes in Patients Undergoing Left Ventricular Assist Device Implantation
Background: Vitamin D is an important hormone that regulates cardiac myocyte function. Low levels contribute to the development of cardiovascular disease and have been implicated in immune function and the inflammatory cascade. Patients who undergo left ventricular assist device (LVAD) implantation are at risk for driveline infection, stroke, and gastrointestinal (GI) bleeding. We investigated whether serum 25‐hydroxy (25‐OH) vitamin D levels affect clinical outcomes after LVAD.Methods: 212 patients who underwent LVAD implantation between 2010 and 2015 were included. We measured preoperative 25‐OH vitamin D level and postoperative adverse events during the first year. Vitamin D level was classified into 3 categories: normal (>30 ng/mL), insufficient (20–30 ng/mL), and deficient (P = .07) for insufficiency and 11.467 (95% CI: 1.204–109.26; P = .03) for deficiency. Vitamin D levels were not associated with GI bleeding, length of stay, or stroke.Conclusions: In patients with LVAD, both deficiency and insufficiency of 25‐OH vitamin D levels are independently associated with increased postoperative driveline infection risk and higher rate of readmission. Further trials are needed to confirm whether a repletion regimen could be a promising means of decreasing the risk for these postoperative adverse events.
- 30 March 2018
- Published by Wiley in Nutrition in Clinical Practice
- Vol. 33 (6) , 825-830
Effect of Vitamin D Level on Clinical Outcomes in Patients Undergoing Left Ventricular Assist Device Implantation
Background: Vitamin D is an important hormone that regulates cardiac myocyte function. Low levels contribute to the development of cardiovascular disease and have been implicated in immune function and the inflammatory cascade. Patients who undergo left ventricular assist device (LVAD) implantation are at risk for driveline infection, stroke, and gastrointestinal (GI) bleeding. We investigated whether serum 25‐hydroxy (25‐OH) vitamin D levels affect clinical outcomes after LVAD.Methods: 212 patients who underwent LVAD implantation between 2010 and 2015 were included. We measured preoperative 25‐OH vitamin D level and postoperative adverse events during the first year. Vitamin D level was classified into 3 categories: normal (>30 ng/mL), insufficient (20–30 ng/mL), and deficient (P = .07) for insufficiency and 11.467 (95% CI: 1.204–109.26; P = .03) for deficiency. Vitamin D levels were not associated with GI bleeding, length of stay, or stroke.Conclusions: In patients with LVAD, both deficiency and insufficiency of 25‐OH vitamin D levels are independently associated with increased postoperative driveline infection risk and higher rate of readmission. Further trials are needed to confirm whether a repletion regimen could be a promising means of decreasing the risk for these postoperative adverse events.
- 1 November 2017
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 9 (11) , 4441-4446
The impact of extreme obesity on outcomes after left ventricular assist device implantation
Background: The association between extreme body mass index (BMI) and outcomes in left ventricular assist device (LVAD) patients has not been well established. With the commercial use of LVADs a larger number of patients with a BMI >40 have undergone device implantation. The purpose of this study was to evaluate the short and long-term outcomes of LVAD patients with extreme obesity. Methods: A retrospective review of all patients (n=383) at our center who received a LVAD as primary implant between 2005–2015 was performed. Demographics, preoperative laboratory values, and postoperative outcomes were analyzed. Patients were divided into three groups based on BMI (kg/m2) classification (group 1: ≤25; group 2: 25 to 35; group 3: ≥35) and compared using one-way analysis of variance (ANOVA), Kruskal-Wallis and Chi-squared analysis as appropriate. Results: Comparison of postoperative outcomes demonstrated an increased risk of respiratory failure and right ventricular (RV) failure in patients with a BMI ≥35 (range, 35–59). Length of stay, sternal infection, driveline/pocket infection, systemic infection, GI-bleeding, and neurological events within the first year of device therapy were not related to BMI. Survival at 30-day, 1- and 2-year was not significantly different among the three groups. The group with the smallest BMI demonstrated an increased risk for re-operative bleeding. Conclusions: Despite an increased risk of early morbidity in patients with extreme obesity, long term survival was not significantly different between the BMI groups. Careful consideration is recommended when evaluating patients with an excessive BMI for LVAD therapy although it should not be a contraindication for device placement.
- 1 November 2017
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 9 (11) , 4441-4446
The impact of extreme obesity on outcomes after left ventricular assist device implantation
Background: The association between extreme body mass index (BMI) and outcomes in left ventricular assist device (LVAD) patients has not been well established. With the commercial use of LVADs a larger number of patients with a BMI >40 have undergone device implantation. The purpose of this study was to evaluate the short and long-term outcomes of LVAD patients with extreme obesity. Methods: A retrospective review of all patients (n=383) at our center who received a LVAD as primary implant between 2005–2015 was performed. Demographics, preoperative laboratory values, and postoperative outcomes were analyzed. Patients were divided into three groups based on BMI (kg/m2) classification (group 1: ≤25; group 2: 25 to 35; group 3: ≥35) and compared using one-way analysis of variance (ANOVA), Kruskal-Wallis and Chi-squared analysis as appropriate. Results: Comparison of postoperative outcomes demonstrated an increased risk of respiratory failure and right ventricular (RV) failure in patients with a BMI ≥35 (range, 35–59). Length of stay, sternal infection, driveline/pocket infection, systemic infection, GI-bleeding, and neurological events within the first year of device therapy were not related to BMI. Survival at 30-day, 1- and 2-year was not significantly different among the three groups. The group with the smallest BMI demonstrated an increased risk for re-operative bleeding. Conclusions: Despite an increased risk of early morbidity in patients with extreme obesity, long term survival was not significantly different between the BMI groups. Careful consideration is recommended when evaluating patients with an excessive BMI for LVAD therapy although it should not be a contraindication for device placement.
- 1 July 2017
- Published by Elsevier in Psychosomatics
- Vol. 58 (4) , 406-414
Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation
- 1 July 2017
- Published by Elsevier in Psychosomatics
- Vol. 58 (4) , 406-414
Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation
- 20 September 2016
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 33 (3) , 203-208
The Sodium Paradox: Dysnatremia and Mortality in Patients Implanted With Extracorporeal Mechanical Circulatory Support Devices
Introduction: Dysnatremia, abnormal serum sodium levels, has long been used as a marker for disease progression in heart failure patients. Classically, hyponatremia is associated with increased fluid volume in heart failure and is often a result of neuroendocrine dysfunction and poor cardiac output. Recent studies have noted that dysnatremia and hypernatremia are predictive of worsened outcomes in critical care and renal disease populations. We investigated the relationship between dysnatremia and postoperative outcomes in patients implanted with extracorporeal mechanical circulatory devices. Methods: A total of 97 patients who underwent implantation with the CentriMag mechanical circulatory assist system were included in this retrospective study. Patients were divided into 2 groups based on preoperative serum sodium level cutoff of 135 mEq/L. Outcomes and mortality were compared between groups. Results: The mean age for the study population was 56.21 ± 15.13 years, and 57 patients (58.8%) were male. The mean time on CentriMag support was 22.7 days. Patients with serum sodium levels ≤135 mEq/L were noted to have significantly worsened indicators of preoperative cardiac function. However, patients with serum sodium levels >135 mEq/L had significantly shorter postoperative survival (P = .006). When entered into a multivariate Cox proportional hazards model, sodium was an independent predictor for increased risk of mortality (hazard ratio: 1.224; 95% confidence interval: 1.009-1.485; P = .040). Conclusion: Our results indicate that elevated preoperative sodium in patients undergoing implantation of a temporary mechanical circulatory support system is predictive of worsened postoperative survival.
- 20 September 2016
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 33 (3) , 203-208
The Sodium Paradox: Dysnatremia and Mortality in Patients Implanted With Extracorporeal Mechanical Circulatory Support Devices
Introduction: Dysnatremia, abnormal serum sodium levels, has long been used as a marker for disease progression in heart failure patients. Classically, hyponatremia is associated with increased fluid volume in heart failure and is often a result of neuroendocrine dysfunction and poor cardiac output. Recent studies have noted that dysnatremia and hypernatremia are predictive of worsened outcomes in critical care and renal disease populations. We investigated the relationship between dysnatremia and postoperative outcomes in patients implanted with extracorporeal mechanical circulatory devices. Methods: A total of 97 patients who underwent implantation with the CentriMag mechanical circulatory assist system were included in this retrospective study. Patients were divided into 2 groups based on preoperative serum sodium level cutoff of 135 mEq/L. Outcomes and mortality were compared between groups. Results: The mean age for the study population was 56.21 ± 15.13 years, and 57 patients (58.8%) were male. The mean time on CentriMag support was 22.7 days. Patients with serum sodium levels ≤135 mEq/L were noted to have significantly worsened indicators of preoperative cardiac function. However, patients with serum sodium levels >135 mEq/L had significantly shorter postoperative survival (P = .006). When entered into a multivariate Cox proportional hazards model, sodium was an independent predictor for increased risk of mortality (hazard ratio: 1.224; 95% confidence interval: 1.009-1.485; P = .040). Conclusion: Our results indicate that elevated preoperative sodium in patients undergoing implantation of a temporary mechanical circulatory support system is predictive of worsened postoperative survival.
- 6 September 2016
- Published by Wiley in Nutrition in Clinical Practice
- Vol. 32 (1) , 98-102
Relationship Between Handgrip Strength and Length of Stay for Left Ventricular Assist Device Implantation
Background: Advanced heart failure is associated with a wide range of physiological derangements, including muscular deterioration, weight loss, and cardiac cachexia. These conditions, as well as poor nutrition status, have been shown to affect the quality of outcomes in patients who undergo left ventricular assist device (LVAD) implantation. Noting that handgrip strength has been shown to be an effective indicator of poor functional status, muscular strength, and nutrition, we investigated its use as a tool for prediction of length of stay (LOS) in patients undergoing LVAD implantation. Materials and Methods: Handgrip strength was measured in 90 patients undergoing evaluation for LVAD implantation using the Jamar Hand Dynamometer. Handgrip strength was normalized to body weight (HGS:BW), and patients were divided into 2 groups: those with HGS:BW Results: Patients with lower HGS:BW tended to have worsened clinical indicators of heart failure severity, including reduced ejection fraction, serum albumin, and hemoglobin and increased B‐type natriuretic peptide and white blood cell count. Lower HGS:BW was an independent predictor for increased LOS. Conclusion: Handgrip strength measurement at the bedside is a simple and effective means of assessing functional status and risk for increased LOS following LVAD implantation, which may aid in preoperative evaluation of LVAD candidacy.
- 6 September 2016
- Published by Wiley in Nutrition in Clinical Practice
- Vol. 32 (1) , 98-102
Relationship Between Handgrip Strength and Length of Stay for Left Ventricular Assist Device Implantation
Background: Advanced heart failure is associated with a wide range of physiological derangements, including muscular deterioration, weight loss, and cardiac cachexia. These conditions, as well as poor nutrition status, have been shown to affect the quality of outcomes in patients who undergo left ventricular assist device (LVAD) implantation. Noting that handgrip strength has been shown to be an effective indicator of poor functional status, muscular strength, and nutrition, we investigated its use as a tool for prediction of length of stay (LOS) in patients undergoing LVAD implantation. Materials and Methods: Handgrip strength was measured in 90 patients undergoing evaluation for LVAD implantation using the Jamar Hand Dynamometer. Handgrip strength was normalized to body weight (HGS:BW), and patients were divided into 2 groups: those with HGS:BW Results: Patients with lower HGS:BW tended to have worsened clinical indicators of heart failure severity, including reduced ejection fraction, serum albumin, and hemoglobin and increased B‐type natriuretic peptide and white blood cell count. Lower HGS:BW was an independent predictor for increased LOS. Conclusion: Handgrip strength measurement at the bedside is a simple and effective means of assessing functional status and risk for increased LOS following LVAD implantation, which may aid in preoperative evaluation of LVAD candidacy.
- 1 August 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (8) , S111
Effect of Vitamin D Level on Readmission Rates in Patients With Left Ventricular Assist Devices
- 1 August 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (8) , S111
Effect of Vitamin D Level on Readmission Rates in Patients With Left Ventricular Assist Devices
Efficacy of Inpatient Rehabilitation After Left Ventricular Assist Device Implantation
Background: Left ventricular assist devices (LVADs) have become an increasingly popular and effective means for treating advanced heart failure. LVAD implantation requires extensive surgery and postoperative rehabilitation. The Functional Independence Measure (FIM) has been used to quantify functional gains in numerous patient populations, including those with stroke and spinal cord injury. This study investigated functional improvements in patients undergoing LVAD implantation using the FIM score.Objective: To assess functional improvements in patients with advanced heart failure who underwent LVAD implantation.Design: Retrospective.Setting: Inpatient rehabilitation unit.Subjects: Ninety consecutive patients who received acute inpatient rehabilitation after continuous flow LVAD implantation.Methods: Demographic, laboratory, and functional outcomes data including inpatient rehabilitation unit (IRU) length of stay (LOS), discharge disposition, and FIM score were collected for all patients. Paired t‐tests were used to assess change in functional measures and laboratory data.Main Outcome Measures: Primary outcome measures included FIM gain, FIM efficiency, discharge disposition, rates of readmission after discharge from rehabilitation, and LOS in the rehabilitation unit.Results: The FIM gain was statistically significant at 28.4 ± 12.3 (P < .001) and compared favorably with benchmarks for mean FIM gains at our facility (26.4), regionally (21.5), and nationally (22.7) for patients admitted to IRUs with a cardiac diagnosis. FIM efficiency (FIM gain/IRU LOS) was 1.9 ± 1.0 compared with the mean FIM efficiency at our facility (2.2), regionally (2.1), and nationally (2.2). Seventy‐four percent (n = 67) of patients were discharged directly home after inpatient rehabilitation, 17% (n = 16) were readmitted to the acute hospital service, and 8% (n = 7) required additional rehabilitation at a subacute rehabilitation facility. The IRU LOS was 16.2 ± 6.9 days.Conclusions: Our study indicates that most patients with an LVAD achieve clinically meaningful functional gains from acute inpatient rehabilitation, with the majority of patients being discharged home. Further studies need to be performed to analyze clinical outcomes after acute inpatient rehabilitation.Level of Evidence: IV
Efficacy of Inpatient Rehabilitation After Left Ventricular Assist Device Implantation
Background: Left ventricular assist devices (LVADs) have become an increasingly popular and effective means for treating advanced heart failure. LVAD implantation requires extensive surgery and postoperative rehabilitation. The Functional Independence Measure (FIM) has been used to quantify functional gains in numerous patient populations, including those with stroke and spinal cord injury. This study investigated functional improvements in patients undergoing LVAD implantation using the FIM score.Objective: To assess functional improvements in patients with advanced heart failure who underwent LVAD implantation.Design: Retrospective.Setting: Inpatient rehabilitation unit.Subjects: Ninety consecutive patients who received acute inpatient rehabilitation after continuous flow LVAD implantation.Methods: Demographic, laboratory, and functional outcomes data including inpatient rehabilitation unit (IRU) length of stay (LOS), discharge disposition, and FIM score were collected for all patients. Paired t‐tests were used to assess change in functional measures and laboratory data.Main Outcome Measures: Primary outcome measures included FIM gain, FIM efficiency, discharge disposition, rates of readmission after discharge from rehabilitation, and LOS in the rehabilitation unit.Results: The FIM gain was statistically significant at 28.4 ± 12.3 (P < .001) and compared favorably with benchmarks for mean FIM gains at our facility (26.4), regionally (21.5), and nationally (22.7) for patients admitted to IRUs with a cardiac diagnosis. FIM efficiency (FIM gain/IRU LOS) was 1.9 ± 1.0 compared with the mean FIM efficiency at our facility (2.2), regionally (2.1), and nationally (2.2). Seventy‐four percent (n = 67) of patients were discharged directly home after inpatient rehabilitation, 17% (n = 16) were readmitted to the acute hospital service, and 8% (n = 7) required additional rehabilitation at a subacute rehabilitation facility. The IRU LOS was 16.2 ± 6.9 days.Conclusions: Our study indicates that most patients with an LVAD achieve clinically meaningful functional gains from acute inpatient rehabilitation, with the majority of patients being discharged home. Further studies need to be performed to analyze clinical outcomes after acute inpatient rehabilitation.Level of Evidence: IV