WSWei-Chung Su

Wei-Chung Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei-Chung Su has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Yung Sung Cheng

    A Lovelace Respiratory Research Institute , Albuquerque , New Mexico

    4 shared publications
  • Alexander D. Tolchinsky

    Research Center for Toxicology and Hygienic Regulation of Biopreparations, Serpukchov, Moscow, Russia

    2 shared publications
  • Vladimir I. Sigaev

    Research Center for Toxicology and Hygienic Regulation of Biopreparations, Serpukchov, Moscow, Russia

    2 shared publications
  • Bean T. Chen

    Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention, Morgantown, West Virginia, USA

    1 shared publication
  • Bon Ki Ku

    B National Institute for Occupational Safety and Health , Cincinnati , Ohio

    1 shared publication
  • Pramod Kulkarni

    Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health

    1 shared publication

Latest Publications

  • Deposition of graphene nanomaterial aerosols in human upper airways

    by Wei-Chung Su, Bon Ki Ku, Pramod Kulkarni, Yung Sung Cheng

    Graphene nanomaterials have attracted wide attention in recent years on their application to state-of-the-art technology due to their outstanding physical properties. On the other hand, the nanotoxicity of graphene materials also has rapidly become a serious concern especially in occupational health. Graphene naomaterials inevitably could become airborne in the workplace during manufacturing processes. The inhalation and subsequent deposition of graphene nanomaterial aerosols in the human respiratory tract could potentially result in adverse health effects to exposed workers. Therefore, investigating the deposition of graphene nanomaterial aerosols in the human airways is an indispensable component of an integral approach to graphene occupational health. For this reason, this study carried out a series of airway replica deposition experiments to obtain original experimental data for graphene aerosol airway deposition. In this study, graphene aerosols were generated, size classified, and delivered into human airway replicas (nasal and oral-to-lung airways). The deposition fraction and deposition efficiency of graphene aerosol in the airway replicas were obtained by a novel experimental approach. The experimental results acquired showed that the fractional deposition of graphene aerosols in airway sections studied were all less than 4%, and the deposition efficiency in each airway section was generally lower than 0.03. These results indicate that the majority of the graphene nanomaterial aerosols inhaled into the human respiratory tract could easily penetrate through the head airways as well as the upper part of the tracheobronchial airways and then transit down to the lower lung airways, where undesired biological responses might be induced.


  • Thoracic Fraction of Inhaled Fiber Aerosol

    by Yung Sung Cheng, Wei-Chung Su

    Size-selective sampling is a health-related method to collect airborne particles based on penetration of inhaled particles into different regions of the human respiratory tract; thus, it is the most relevant sampling method to correlate health risks with occupational exposure. The current practice of sampling asbestos and other fibers is not a size-selective method. The thoracic size fraction, defined as the portion of inhaled particles that can penetrate through the larynx, has been suggested as the most relevant size-selective sampling method for fiber aerosol. The thoracic fraction is based on 1-deposition of inhaled spherical particles in the human extrathoracic airways for mouth breathing and corrected for the particle inhalability. There is no comparable information for fiber aerosols; therefore, there is no technical basis to ascertain whether the current thoracic fraction definition is suitable for fiber aerosols. No human data are available from controlled experiments of inhaled fiber aerosols for the obvious reason that most fiber materials are potentially hazardous when inhaled. Our approach was to measure penetration of fiber aerosol in realistic human oropharyngeal airway replicas and to compare that with data from spherical particles. We showed that realistic human oral airway replicas (including the oral cavity, pharynx, and larynx regions) provided useful spherical and fiber particle deposition in the human head airway. These data could be used to test the thoracic fraction curves. The spherical penetration is in agreement with human in vivo data used to establish the thoracic fraction curve. Fiber penetrations through the larynx of two human oral airway replicas were higher than those for spherical particles for the same aerodynamic diameter using the same replicas. The thoracic curve as defined for spherical particles, therefore, may not include some fibers that could penetrate to the thoracic region.


  • Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments

    by Wei-Chung Su, Alexander D. Tolchinsky, Bean T. Chen, Vladimir I. Sigaev, Yung Sung Cheng

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s−1) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.


  • A wind tunnel test of newly developed personal bioaerosol samplers

    by Wei-Chung Su, Alexander D. Tolchinsky, Vladimir I. Sigaev, Yung Sung Cheng

    In this study, the performance of two newly developed personal bioaerosol samplers was evaluated. The two test samplers are cyclone-based personal samplers that incorporate a recirculating liquid film. The performance evaluations focused on the physical efficiencies that a personal bioaerosol sampler could provide, including aspiration, collection, and capture efficiencies. The evaluation tests were carried out in a wind tunnel, and the test personal samplers were mounted on the chest of a full-size manikin placed in the test chamber of the wind tunnel. Monodisperse fluorescent aerosols ranging from 0.5 to 20 μm were used to challenge the samplers. Two wind speeds of 0.5 and 2.0 m/sec were employed as the test wind speeds in this study. The test results indicated that the aspiration efficiency of the two test samplers closely agreed with the ACGIH inhalable convention within the size range of the test aerosols. The aspiration efficiency was found to be independent of the sampling orientation. The collection efficiency acquired from these two samplers showed that the 50% cutoff diameters were both around 0.6 μm. However, the wall loss of these two test samplers increased as the aerosol size increased, and the wall loss of PAS-4 was considerably higher than that of PAS-5, especially in the aerosol size larger than 5 μm, which resulted in PAS-4 having a relatively lower capture efficiency than PAS-5. Overall, the PAS-5 is considered a better personal bioaerosol sampler than the PAS-4.


  • Fiber Deposition Pattern in Two Human Respiratory Tract Replicas

    by Wei-Chung Su, Yung Sung Cheng

    This study consisted of a series of experiments to investigate the factors that might affect the fiber deposition pattern in the human respiratory tract. Carbon fibers with uniform diameter and polydispersed length were chosen as the test material. Two geometry-defined human respiratory tract replicas encompassing the oral cavity, oropharynx, larynx, trachea, and first few bifurcations of the tracheobronchial airways were used in this research. Deposition studies were conducted by delivering aerosolized carbon fibers into the replicas at constant inspiratory flow rates of 15, 43.5, and 60 L/min. The results showed that impaction is the dominant deposition mechanism for both replicas. Most of the fibers with high momentum deposited in the oral airway (oral cavity to larynx), and fibers with low momentum were found to pass through the entire replica easily. When comparing the results between the two replicas, fiber length, inspiratory flow rate, and the geometry of the oral airway were found to be factors that might affect the fiber deposition pattern in the human respiratory tract.