Gino Bella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gino Bella has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Laura Tribioli
Department of Engineering, Niccolò Cusano University, Via don Carlo Gnocchi 3, 00166 Rome, Italy
2 shared publications - Raffaello Cozzolino
Department of Engineering, University of Rome Niccolò Cusano, 00166 Roma, Italy
2 shared publications - Sauro Succi
Istituto Italiano di Tecnologia
2 shared publications - Stefano Ubertini
Department of Economics, Engineering, Society and Business Organization, University of Tuscia, 01100 Viterbo, Italy
2 shared publications - Carlo Nazareno Grimaldi
University of Perugia, Department of Engineering, Via G.Duranti 93 06125 Perugia PG, Italy
1 shared publication - Cecilia Silvestri
Tuscia University, Italy
1 shared publication
Latest Publications
- Open Access
Energy Analysis of a Novel Turbo-Compound System for Mild Hybridization of a Gasoline Engine
Efficient and low-polluting mobility is a major demand in all countries. Hybrid electric vehicles have already shown to be suitable to respond to this need, being a reliable alternative to conventional cars, at least in urban environments. Nevertheless, such vehicles present a yet unexplored potential. In this paper, we will investigate how the powertrain efficiency may possibly benefit, in an integrated drivetrain for a hybrid electric vehicle, based on a turbocharged gasoline engine, of an innovative supercharging system. The compressor and turbine will be mechanically decoupled so as to independently optimize their operation, avoiding turbo lag and maximizing energy recovery by completely eliminating the waste-gate valve. This, in turns, requires changing the turbine so as to have a flattest possible efficiency/load curve. Therefore, an ad-hoc designed turbine will be implemented in the decoupled configuration, to be used to drive an electrical generator and produce electrical energy for charging the battery. This study presents a preliminary assessment of the potential of a turbo-compounded system for a 1L turbocharged gasoline engine for a small city car. To this aim, a one-dimensional dynamic model of the engine has been built in GT-Suite and has been calibrated and validated by means of experimental data obtained on a dynamometer, both in steady state and dynamic conditions. In particular, the model has been calibrated by means of experimental data obtained in stationary conditions and its robustness has then been verified through experimental data obtained under transient conditions. The model also includes data retrieved from the characterization of the existing turbine and compressor, while a new performance map for the turbine has been designed to better exploit the potential of the components’ decoupling. Results include the estimation of energy recovery potential of such a solution. Under the implementation of a straightforward control strategy, which runs both compressor and turbine at the same speed, the system is able to achieve a 60.57% increase in energy recovered from the exhaust gasses in the turbine. Afterwards, an attempt was made to limit the minimum turbine speed to 45000 rpm and simultaneously decrease the instantaneous speed by 3000 rpm compared to the compressor, attaining a further increase of 1.7% in the energy recovered by the turbine.
Open AccessEnergy Analysis of a Novel Turbo-Compound System for Mild Hybridization of a Gasoline Engine
Efficient and low-polluting mobility is a major demand in all countries. Hybrid electric vehicles have already shown to be suitable to respond to this need, being a reliable alternative to conventional cars, at least in urban environments. Nevertheless, such vehicles present a yet unexplored potential. In this paper, we will investigate how the powertrain efficiency may possibly benefit, in an integrated drivetrain for a hybrid electric vehicle, based on a turbocharged gasoline engine, of an innovative supercharging system. The compressor and turbine will be mechanically decoupled so as to independently optimize their operation, avoiding turbo lag and maximizing energy recovery by completely eliminating the waste-gate valve. This, in turns, requires changing the turbine so as to have a flattest possible efficiency/load curve. Therefore, an ad-hoc designed turbine will be implemented in the decoupled configuration, to be used to drive an electrical generator and produce electrical energy for charging the battery. This study presents a preliminary assessment of the potential of a turbo-compounded system for a 1L turbocharged gasoline engine for a small city car. To this aim, a one-dimensional dynamic model of the engine has been built in GT-Suite and has been calibrated and validated by means of experimental data obtained on a dynamometer, both in steady state and dynamic conditions. In particular, the model has been calibrated by means of experimental data obtained in stationary conditions and its robustness has then been verified through experimental data obtained under transient conditions. The model also includes data retrieved from the characterization of the existing turbine and compressor, while a new performance map for the turbine has been designed to better exploit the potential of the components’ decoupling. Results include the estimation of energy recovery potential of such a solution. Under the implementation of a straightforward control strategy, which runs both compressor and turbine at the same speed, the system is able to achieve a 60.57% increase in energy recovered from the exhaust gasses in the turbine. Afterwards, an attempt was made to limit the minimum turbine speed to 45000 rpm and simultaneously decrease the instantaneous speed by 3000 rpm compared to the compressor, attaining a further increase of 1.7% in the energy recovered by the turbine.
- Open Access
A Descriptive Review to Access the Most Suitable Rib’s Configuration of Roughness for the Maximum Performance of Solar Air Heater
Solar air heater is considered to be the most popular and widely used solar thermal system. Solar air heater (SAH) can be used in many applications, ranging from domestic to industrial purposes. However, it seems that the viability of SAH is not feasible due to the following two reasons: (i) the low convective heat transfer coefficient at the absorber plate is the reason that causes a low heat transfer rate to the flowing air, and (ii) the high temperature of the absorber plate insists on high heat losses, thus, reducing the thermal efficiency. The convective coefficient can be augmented by placing turbulators/roughness on the absorber plate, which induces turbulence in the flow passage near the absorber plate by disrupting and destabilizing the laminar sublayer. This comprehensive review has been presented to summarize the studies on artificial roughness/turbulators geometries to enhance the heat transfer rate. Various rib configurations (such as grits, grooves, blockages, baffles, winglets, protrusions, twisted taps, dimples, and mesh wires) and distinct arrangements of rib roughness (such as inclined, transverse, V shape, with gap) have been reviewed to present heat transfer and friction characteristics. Additionally, thermal efficiency and thermohydraulic efficiency (in terms of net effective efficiency) of various artificial roughnesses and rib configurations are presented under distinct operating conditions for comparing purposes. This comparative study has been presented to assess the most desirable ribs and their configurations. On the basis of net effective efficiency, a multiarc rib with gaps is found to be the best configuration among all and have the highest thermal and net effective efficiency of around 79%.
Open AccessA Descriptive Review to Access the Most Suitable Rib’s Configuration of Roughness for the Maximum Performance of Solar Air Heater
Solar air heater is considered to be the most popular and widely used solar thermal system. Solar air heater (SAH) can be used in many applications, ranging from domestic to industrial purposes. However, it seems that the viability of SAH is not feasible due to the following two reasons: (i) the low convective heat transfer coefficient at the absorber plate is the reason that causes a low heat transfer rate to the flowing air, and (ii) the high temperature of the absorber plate insists on high heat losses, thus, reducing the thermal efficiency. The convective coefficient can be augmented by placing turbulators/roughness on the absorber plate, which induces turbulence in the flow passage near the absorber plate by disrupting and destabilizing the laminar sublayer. This comprehensive review has been presented to summarize the studies on artificial roughness/turbulators geometries to enhance the heat transfer rate. Various rib configurations (such as grits, grooves, blockages, baffles, winglets, protrusions, twisted taps, dimples, and mesh wires) and distinct arrangements of rib roughness (such as inclined, transverse, V shape, with gap) have been reviewed to present heat transfer and friction characteristics. Additionally, thermal efficiency and thermohydraulic efficiency (in terms of net effective efficiency) of various artificial roughnesses and rib configurations are presented under distinct operating conditions for comparing purposes. This comparative study has been presented to assess the most desirable ribs and their configurations. On the basis of net effective efficiency, a multiarc rib with gaps is found to be the best configuration among all and have the highest thermal and net effective efficiency of around 79%.
- Open Access
Experimental Study for the Assessment of the Measurement Uncertainty Associated with Electric Powertrain Efficiency Using the Back-to-Back Direct Method
Brushless electric motors are used intensively in the industrial automation sector due to the motors low inertia and fast response. According to the International Electrotechnical Commission, IEC 60034-2-1, the efficiency of a three-phase electric machine (excluding machines for traction vehicles) can be determined by direct or indirect techniques. In the case of small traction motors (<10 kW), direct methods are used extensively by manufacturers, even if no standard has been published or scheduled by the IEC. In this paper, we evaluated the accuracy of the (direct) back-to-back method for the estimation of the energy performance of a 3 kW brushless AC electric motor used in a light electric vehicle. We measured the efficiencies of a pair of motors and inverters, as well as the overall efficiency of the entire power train. The results showed that the methodology was sufficiently accurate and comparable with other indirect methods available in existing literature. Moreover, we developed a Simulink model that used the powertrain efficiency map as the input to perform the simulation of a standard urban driving cycle. The simulation was run 500 times to calculate the probability density function associated with the total range of the vehicle, considering the uncertainty of the efficiency that was determined experimentally. The simulation results confirmed the low deviation of the distribution standard compared to the average value of the range of the vehicle.
Open AccessExperimental Study for the Assessment of the Measurement Uncertainty Associated with Electric Powertrain Efficiency Using the Back-to-Back Direct Method
Brushless electric motors are used intensively in the industrial automation sector due to the motors low inertia and fast response. According to the International Electrotechnical Commission, IEC 60034-2-1, the efficiency of a three-phase electric machine (excluding machines for traction vehicles) can be determined by direct or indirect techniques. In the case of small traction motors (<10 kW), direct methods are used extensively by manufacturers, even if no standard has been published or scheduled by the IEC. In this paper, we evaluated the accuracy of the (direct) back-to-back method for the estimation of the energy performance of a 3 kW brushless AC electric motor used in a light electric vehicle. We measured the efficiencies of a pair of motors and inverters, as well as the overall efficiency of the entire power train. The results showed that the methodology was sufficiently accurate and comparable with other indirect methods available in existing literature. Moreover, we developed a Simulink model that used the powertrain efficiency map as the input to perform the simulation of a standard urban driving cycle. The simulation was run 500 times to calculate the probability density function associated with the total range of the vehicle, considering the uncertainty of the efficiency that was determined experimentally. The simulation results confirmed the low deviation of the distribution standard compared to the average value of the range of the vehicle.
- Open Access
Energy Management of an Off-Grid Hybrid Power Plant with Multiple Energy Storage Systems
In this paper, an off-grid hybrid power plant with multiple storage systems for an artificial island is designed and two possible strategies for the management of the stored energy are proposed. Renewable power sources (wind/solar technologies) are used as primary power suppliers. A lead-acid battery pack (BAT) and a reversible polymer electrolyte fuel cell are employed to fulfill the power demand and to absorb extra power. The reversible fuel cell allows reducing costs and occupied space and the fuel cell can be fed by the pure hydrogen produced by means of its reversible operation as an electrolyzer. A diesel engine is employed as backup system. While HOMER Pro® has been employed for a full-factorial-based optimization of the sizes of the renewable sources and the BAT, Matlab/Simulink® has been later used for simulating the plant operation and compare two possible power management control strategies. For the reversible fuel cell sizing, a sensitivity analysis has been carried out varying stack and hydrogen tank sizes. The final choice for plant configuration and power management control strategy has been made on the basis of a comparative analysis of the results, aimed at minimizing fossil fuel consumption and CO2 emissions, battery aging rate and at maximizing the power plant overall efficiency. The obtained results demonstrate the possibility of realizing a renewable power plant, able to match the needs of electrical power in a remote area, by achieving a good integration of different energy sources and facing the intermittent nature of renewable power sources, with very low use of fossil fuels.
Open AccessEnergy Management of an Off-Grid Hybrid Power Plant with Multiple Energy Storage Systems
In this paper, an off-grid hybrid power plant with multiple storage systems for an artificial island is designed and two possible strategies for the management of the stored energy are proposed. Renewable power sources (wind/solar technologies) are used as primary power suppliers. A lead-acid battery pack (BAT) and a reversible polymer electrolyte fuel cell are employed to fulfill the power demand and to absorb extra power. The reversible fuel cell allows reducing costs and occupied space and the fuel cell can be fed by the pure hydrogen produced by means of its reversible operation as an electrolyzer. A diesel engine is employed as backup system. While HOMER Pro® has been employed for a full-factorial-based optimization of the sizes of the renewable sources and the BAT, Matlab/Simulink® has been later used for simulating the plant operation and compare two possible power management control strategies. For the reversible fuel cell sizing, a sensitivity analysis has been carried out varying stack and hydrogen tank sizes. The final choice for plant configuration and power management control strategy has been made on the basis of a comparative analysis of the results, aimed at minimizing fossil fuel consumption and CO2 emissions, battery aging rate and at maximizing the power plant overall efficiency. The obtained results demonstrate the possibility of realizing a renewable power plant, able to match the needs of electrical power in a remote area, by achieving a good integration of different energy sources and facing the intermittent nature of renewable power sources, with very low use of fossil fuels.
- 1 January 2013
- Published by Global Science Press in Communications in Computational Physics
- Vol. 13 (3) , 685-695
Lattice Boltzmann Simulation of Cavitating Flows
Lattice Boltzmann Simulation of Cavitating Flows - Volume 13 Issue 3 - Giacomo Falcucci, Stefano Ubertini, Gino Bella, Sauro Succi
- 1 January 2013
- Published by Global Science Press in Communications in Computational Physics
- Vol. 13 (3) , 685-695
Lattice Boltzmann Simulation of Cavitating Flows
Lattice Boltzmann Simulation of Cavitating Flows - Volume 13 Issue 3 - Giacomo Falcucci, Stefano Ubertini, Gino Bella, Sauro Succi
- 1 June 2010
- Published by Global Science Press in Communications in Computational Physics
- Vol. 7 (3) , 423-444
Improved Lattice Boltzmann Without Parasitic Currents for Rayleigh-Taylor Instability
- 1 June 2010
- Published by Global Science Press in Communications in Computational Physics
- Vol. 7 (3) , 423-444
Improved Lattice Boltzmann Without Parasitic Currents for Rayleigh-Taylor Instability