WHWilliam F. Harris

William F. Harris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


William F. Harris has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thin lenses of asymmetric power

    by W. F. Harris, R. D. Van Gool

    It is generally supposed that thin systems, including refracting surfaces and thin lenses, have powers that are necessarily symmetric. In other words they have powers which can be represented assymmetric dioptric power matrices and in the familar spherocylindrical form used in optometry and ophthalmology. This paper shows that this is not correct and that it is indeed possible for a thin system to have a power that is not symmetric and which cannot be expressed in spherocylindrical form. Thin systems of asymmetric power are illustratedby means of a thin lens that is modelled with small prisms and is chosen to have a dioptric power ma-trix that is antisymmetric. Similar models can be devised for a thin system whose dioptric power matrix is any 2 2 × matrix. Thus any power, symmetric, asymmetric or antisymmetric, is possible for a thin system. In this sense our understanding of the power of thin systems is now complete.


  • Effect of Tilt on the Tilted Power Vector of a Thin Lens

    by W F. Harris

    Purpose.: The purpose of this study is to derive the equation for the effect of tilt on the tilted power vector of a possibly astigmatic thin lens. Methods.: The analysis makes use of the equation for tilted power in terms of the dioptric power matrix. Results.: A simple equation is obtained for the tilted power vector of a thin lens in terms of the untilted power vector of the lens. A solution of the equation provides a means for compensating spectacle lenses for tilt. Numerical examples are presented in the Appendix (available online at www.optvissci.com ). Conclusions.: The equation gives insight and is useful for researchers and clinicians working in terms of power expressed as power vectors.


  • Curvature of ellipsoids and other surfaces

    by W. F. Harris

    From differential geometry one obtains an expression for the curvature in any direction at a point on a surface. The general theory is outlined. The theory is then specialised for surfaces that are represented parametrically as height over a transverse plane. The general ellipsoid is treated in detail as a special case. A quadratic equation gives the principal directions at the point and, hence, the principal curvatures associated with them. Equations are obtained for ellipsoids in general that are generalisations of Bennett's equations for sagittal and tangential curvature of ellipsoids of revolution. Equations are also presented for the locations of umbilic points on the ellipsoid.


  • The exponential‐mean‐log‐transference as a possible representation of the optical character of an average eye

    by W. F. Harris, J. R. Cardoso

    Considering a set of eyes, how does one define an average whose optical character represents an average of the optical characters of the eyes in the set? The recent proposal of the exponential‐mean‐log‐transference was based on a conjecture. The purpose of this note is to provide justification by proving the conjecture and defining the conditions under which it fails.


  • Sequential Tilt and Tilted Power of Thin Lenses

    by W F. Harris

    Purpose.: The purposes of this article were, for any sequence of tilts applied to a thin lens, to calculate an equivalent turn and single tilt, to show how to use the equivalent turn and tilt to calculate the tilted power of the lens, and, given the desired tilted power, to calculate the power of the untilted lens necessary to compensate for the effects of tilt. The untilted lens may be stigmatic (spherical) or astigmatic (spherocylindrical). Methods.: The analysis makes use of rotation matrices to represent rotation in space and previous work in third‐order optics on oblique central refraction. Results.: Equations are presented for calculating the combination of turn and tilt that is equivalent to any sequence of tilts. They are specialized for the particular case of combinations of faceform and pantoscopic tilts and allow the decomposition of an arbitrary tilt into a combination of turn and pantoscopic and faceform tilts. The equations also lead to a procedure for calculating or compensating for the tilted power of a sequentially tilted thin lens. Conclusions.: Previous work on the effect of tilt on thin lenses has been generalized to handle combinations of arbitrary tilts.


  • Reduction of artefact in scatter plots of spherocylindrical data

    by W. F. Harris

    Round‐off of spherocylindrical powers, to multiples of 0.25 D (for example) in the case of sphere and cylinder, and 1 or 5° in the case of axis, represents a type of distortion of the data. The result can be artefacts in graphical representations, which can mislead the researcher. Lines and clusters can appear, some caused by moiré effects, which have no deeper significance. Furthermore artefacts can obscure meaningful information in the data including bimodality and other forms of departure from normality. A process called unrounding is described which largely eliminates these artefacts; each rounded power is replaced by a power chosen randomly from the powers that make up what is called the error cell of the rounded power.


    • 1 December 2004
      • Vol. 81  (12) , 947-52

    Stigmatic optical systems.

    by W F Harris

    There would appear to be little disagreement on what constitutes an astigmatic system in the case of a thin lens: the cylinder is not zero. A spherical thin lens is stigmatic or not astigmatic. The issue is less clear in the case of a thick system. For example, is an eye stigmatic merely because its refraction is stigmatic (spherical)? In this article, a system is defined to be stigmatic if and only if, through the system, every point object maps to a point image. Every other system is astigmatic. Thus, a system is astigmatic if and only if there exists a point object for which the image is not a point. This article is restricted to linear optics. The optical character of a system is completely determined by the ray transference of the system. The objective here is to find those conditions on the transference for which the system is stigmatic or astigmatic. The result is that, for a stigmatic system, all the 2 x 2 submatrices are scalar multiples of a common orthogonal matrix. For a system to be stigmatic, it is not sufficient that its power be stigmatic. An eye may be astigmatic despite having a stigmatic refraction.


    • 1 December 2004
      • Vol. 81  (12) , 953-9

    Proper and improper stigmatic optical systems.

    by W F Harris

    Stigmatic optical systems are of two classes: proper and improper stigmatic systems. The purpose of the article is to explore the nature of the two classes. The image may be rotated in the case of proper stigmatic systems and is reflected in a line in the image plane in improper stigmatic systems. Chirality is preserved through proper stigmatic systems but reversed in improper systems. The image also undergoes magnification that is the same in all meridians and, in the case of decentered systems, a transverse translation. Negative magnification implies inversion in a point. The magnification depends on the distance of the object plane from the system, whereas the rotation and reflection do not. The article shows how to identify a system as astigmatic or proper or improper stigmatic from the transference and how to construct the transference of a system that will achieve a particular magnification and rotation or reflection.


  • The average eye

    by W. F. Harris

    For statistical and other purposes one needs to be able to determine an average eye. An average of refractive errors is readily calculated as an average of dioptric power matrices. A refractive error, however, is not so much a property of the eye as a property of the compensating lens in front of the eye. As such, it ignores other aspects of the optical character of the eye. This paper discusses the difficulties of finding a suitable average that fully accounts for the first‐order optics of a set of optical systems. It proposes an average based on ray transferences and logarithms and exponentials of matrices. Application to eyes in particular is discussed.