Ole D. Wolthers
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ole D. Wolthers has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Heuck
Department of Paediatrics, Aarhus University Hospital, Aarhus, Denmark
2 shared publications Anders J. Schou
Children's Clinic Randers, Randers, Denmark
1 shared publicationC. Heuck
Children's Clinic Randers, Randers, Department of Paediatrics and Institute of Experimental Clinical Research, Medical Research Laboratories, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationC. Skjaerbask
1 shared publicationCarsten Heuck
Children's Clinic Randers, Randers, Denmark
1 shared publicationF. R. C. Path
Department of Chemical Pathology, UCL Middlesex Hospital, London, UK
1 shared publication
Latest Publications
- 25 September 2003
- Published by Wiley in Pediatric Pulmonology
- Vol. 36 (5) , 399-404
Does vitamin D administered to children with asthma treated with inhaled glucocorticoids affect short‐term growth or bone turnover?
Our objective was to assess whether administration of 25‐OH‐vitamin D to children with asthma treated with inhaled dry‐powder budesonide 400 μg daily affects short‐term growth or markers of bone turnover. We utilized a randomized, double‐blind, two‐period crossover trial with run‐in and washout periods of 2 weeks and treatment periods of 4 weeks duration. The setting was an Outpatient clinic in a secondary referral center. Subjects included 14 boys and 3 girls with a mean age of 11.7 (range, 6.1–14.4) years. Interventions included 15 μg (600 IU) 25‐OH‐vitamin D (cholecalciferol) in one tablet ABCDin® once daily in the morning. Primary outcome measures were: lower leg growth rate, serum osteocalcin, and serum markers of type I collagen turnover, i.e., the amino terminal propeptide of type I procollagen (PINP), the carboxy terminal propeptide of type I procollagen (PICP) (formation markers), and the carboxy terminal pyridinoline cross‐linked telopeptide of type I collagen (ICTP) (degradation markers). Secondary outcome measures were parameters of asthma control and serum 25‐OH‐vitamin D. Lower leg growth rate was 0.22 mm/week during vitamin D and 0.25 mm/week during placebo treatment (NS). Osteocalcin was 59.9 and 57.8 μg/l during vitamin D and placebo treatment, respectively, PINP 574 and 565 μg/l, PICP 381 and 382 μg/l, and ICTP 11.5 and 11.1 μg/l, respectively (NS). Serum 25‐OH‐vitamin D was 76.3 nmol/l and 48.2 nmol/l, respectively (P < 0.001). There were no statistically significant differences in measures of pulmonary function. In conclusion, administration of 25‐OH‐vitamin D does not affect short‐term growth or markers of bone turnover in children with asthma treated with inhaled dry‐powder budesonide 400 μg daily. Pediatr Pulmonol. 2003; 36:399–404.
- 25 September 2003
- Published by Wiley in Pediatric Pulmonology
- Vol. 36 (5) , 399-404
Does vitamin D administered to children with asthma treated with inhaled glucocorticoids affect short‐term growth or bone turnover?
Our objective was to assess whether administration of 25‐OH‐vitamin D to children with asthma treated with inhaled dry‐powder budesonide 400 μg daily affects short‐term growth or markers of bone turnover. We utilized a randomized, double‐blind, two‐period crossover trial with run‐in and washout periods of 2 weeks and treatment periods of 4 weeks duration. The setting was an Outpatient clinic in a secondary referral center. Subjects included 14 boys and 3 girls with a mean age of 11.7 (range, 6.1–14.4) years. Interventions included 15 μg (600 IU) 25‐OH‐vitamin D (cholecalciferol) in one tablet ABCDin® once daily in the morning. Primary outcome measures were: lower leg growth rate, serum osteocalcin, and serum markers of type I collagen turnover, i.e., the amino terminal propeptide of type I procollagen (PINP), the carboxy terminal propeptide of type I procollagen (PICP) (formation markers), and the carboxy terminal pyridinoline cross‐linked telopeptide of type I collagen (ICTP) (degradation markers). Secondary outcome measures were parameters of asthma control and serum 25‐OH‐vitamin D. Lower leg growth rate was 0.22 mm/week during vitamin D and 0.25 mm/week during placebo treatment (NS). Osteocalcin was 59.9 and 57.8 μg/l during vitamin D and placebo treatment, respectively, PINP 574 and 565 μg/l, PICP 381 and 382 μg/l, and ICTP 11.5 and 11.1 μg/l, respectively (NS). Serum 25‐OH‐vitamin D was 76.3 nmol/l and 48.2 nmol/l, respectively (P < 0.001). There were no statistically significant differences in measures of pulmonary function. In conclusion, administration of 25‐OH‐vitamin D does not affect short‐term growth or markers of bone turnover in children with asthma treated with inhaled dry‐powder budesonide 400 μg daily. Pediatr Pulmonol. 2003; 36:399–404.
- 12 August 2003
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 14 (4) , 248-254
Eosinophil granule proteins in the assessment of airway inflammation in pediatric bronchial asthma
Eosinophil granule proteins such as eosinophil cationic protein (ECP), eosinophil peroxidase (EPO) and eosinophil protein X (EPX) in serum and urine are indirect measures of eosinophil activity. The measures have been evaluated for prediction, diagnosis and monitoring of anti‐inflammatory treatment modalities in children with asthma. Assessments in serum and urine are highly dependent on sampling procedures and must be performed under strictly controlled conditions using standardized sampling and laboratory procedures. The measures are influenced by circadian and seasonal variations. Measurement of the eosinophil granule proteins does not improve the predictive value of a family history of atopy. Due to insufficient sensitivity and specificity, the measures are not useful in the diagnosis of asthma in children, and the clinical use of eosinophil proteins in the individual child for assessment of asthma severity has not been sufficiently validated. Serum and urine eosinophil granule proteins, however, may be useful in extending our knowledge of suppressive effects on eosinophil activity of various doses, devices and administration regimens of inhaled glucocorticoids in children. Such evaluations may be performed in randomized, double‐blind trials of well‐defined age groups and they should include measures of compliance. One important aspect to look at would be the distinction between suppressive effects on eosinophil activity and clinically important anti‐inflammatory effects. Considering the complexity of airway inflammation and the heterogeneity of childhood asthma, however, it may be too simplistic to look for a single measure of the inflammatory processes. In the future, perhaps, a combination of products of inflammatory cells may give more clinically relevant information with respect to prediction, diagnosis, monitoring and outcome of childhood asthma.
- 12 August 2003
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 14 (4) , 248-254
Eosinophil granule proteins in the assessment of airway inflammation in pediatric bronchial asthma
Eosinophil granule proteins such as eosinophil cationic protein (ECP), eosinophil peroxidase (EPO) and eosinophil protein X (EPX) in serum and urine are indirect measures of eosinophil activity. The measures have been evaluated for prediction, diagnosis and monitoring of anti‐inflammatory treatment modalities in children with asthma. Assessments in serum and urine are highly dependent on sampling procedures and must be performed under strictly controlled conditions using standardized sampling and laboratory procedures. The measures are influenced by circadian and seasonal variations. Measurement of the eosinophil granule proteins does not improve the predictive value of a family history of atopy. Due to insufficient sensitivity and specificity, the measures are not useful in the diagnosis of asthma in children, and the clinical use of eosinophil proteins in the individual child for assessment of asthma severity has not been sufficiently validated. Serum and urine eosinophil granule proteins, however, may be useful in extending our knowledge of suppressive effects on eosinophil activity of various doses, devices and administration regimens of inhaled glucocorticoids in children. Such evaluations may be performed in randomized, double‐blind trials of well‐defined age groups and they should include measures of compliance. One important aspect to look at would be the distinction between suppressive effects on eosinophil activity and clinically important anti‐inflammatory effects. Considering the complexity of airway inflammation and the heterogeneity of childhood asthma, however, it may be too simplistic to look for a single measure of the inflammatory processes. In the future, perhaps, a combination of products of inflammatory cells may give more clinically relevant information with respect to prediction, diagnosis, monitoring and outcome of childhood asthma.
- 4 April 2003
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 14 (2) , 130-133
Circadian variations in serum eosinophil cationic protein, and serum and urine eosinophil protein X
Biochemical evaluation of inflammation may be a useful adjunct to measures of pulmonary function and symptoms in children with asthma. However, little data have been provided to validate the markers in children. The aim of the present study was to assess circadian variations in serum eosinophil cationic protein (ECP), and serum and urine eosinophil protein X (EPX) in children. Five girls and two boys aged 10–14 years were studied. The first sample of urine consisted of urine collected from 24.00 hours the night before until 08.00 hours on the morning of the day of investigation. Thereafter urine was collected at 4‐h intervals until 24.00 hours and in another 8‐h interval from 24.00 to 08.00 hours. Blood samples for assessment of serum ECP and serum EPX were collected every 2 h during the 24 h. Statistically significant circadian variations in serum ECP (F=3.2, p=0.002), serum EPX (F=3.1, p=0.002) and in urine EPX/creatinine (F=5.4, p=0.003) were detected. The concentrations were higher during the night compared to daytime. Peak levels of serum ECP (mean [± SEM]) were found at 06.00 hours (16.3 [5.3] µg/l), trough levels at 08.00 hours (3.9 [0.7] µg/l) (p=0.01). Peak levels of serum EPX were seen at 06.00 (43.7 [9.5] µg/l) with trough levels at 12.00 hours (22.0 [3.5] µg/l) (p=0.01). Peak levels of urine EPX/creatinine occurred in urine collected from 24.00 to 08.00 hours (90.0 [27.7] µg/mmol), trough levels in the 16.00–20.00 hours sample (29.7 [8.9] µg/mmol) (p=0.02). Serum ECP, serum EPX and urine EPX exhibit a circadian variation in children with nocturnal and early morning peak levels. To avoid confounding influence from circadian variations in ECP and EPX in clinical studies blood or urine should be sampled at consistent times.
- 4 April 2003
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 14 (2) , 130-133
Circadian variations in serum eosinophil cationic protein, and serum and urine eosinophil protein X
Biochemical evaluation of inflammation may be a useful adjunct to measures of pulmonary function and symptoms in children with asthma. However, little data have been provided to validate the markers in children. The aim of the present study was to assess circadian variations in serum eosinophil cationic protein (ECP), and serum and urine eosinophil protein X (EPX) in children. Five girls and two boys aged 10–14 years were studied. The first sample of urine consisted of urine collected from 24.00 hours the night before until 08.00 hours on the morning of the day of investigation. Thereafter urine was collected at 4‐h intervals until 24.00 hours and in another 8‐h interval from 24.00 to 08.00 hours. Blood samples for assessment of serum ECP and serum EPX were collected every 2 h during the 24 h. Statistically significant circadian variations in serum ECP (F=3.2, p=0.002), serum EPX (F=3.1, p=0.002) and in urine EPX/creatinine (F=5.4, p=0.003) were detected. The concentrations were higher during the night compared to daytime. Peak levels of serum ECP (mean [± SEM]) were found at 06.00 hours (16.3 [5.3] µg/l), trough levels at 08.00 hours (3.9 [0.7] µg/l) (p=0.01). Peak levels of serum EPX were seen at 06.00 (43.7 [9.5] µg/l) with trough levels at 12.00 hours (22.0 [3.5] µg/l) (p=0.01). Peak levels of urine EPX/creatinine occurred in urine collected from 24.00 to 08.00 hours (90.0 [27.7] µg/mmol), trough levels in the 16.00–20.00 hours sample (29.7 [8.9] µg/mmol) (p=0.02). Serum ECP, serum EPX and urine EPX exhibit a circadian variation in children with nocturnal and early morning peak levels. To avoid confounding influence from circadian variations in ECP and EPX in clinical studies blood or urine should be sampled at consistent times.
- 1 July 2002
- Published by S. Karger AG in Hormone Research in Paediatrics
- Vol. 57 (Suppl. 2) , 83-87
Growth Problems in Children with Asthma
Growth problems are often seen in children with asthma. Rarely, these problems may be caused by poor asthma control. Negatively-deviating growth curves in asthmatic boys aged 8–15 years are often associated with a chronic delay in growth and puberty. Daily treatment with any dose of systemic corticosteroids suppresses the growth rate for as long as the treatment is maintained. The risk of growth rate suppression due to inhaled corticosteroids depends on the dose, administration regimen and delivery device. The risk becomes significant with ≧800 µg budesonide from a metered-dose inhaler with a spacer, and with ≧400 µg budesonide or fluticasone propionate from a dry-powder inhaler. Regardless of the treatment modality applied, all children with asthma should have their height growth measured at least every 6 months, and indications for endocrine work-up should follow general criteria for a growth-insufficient child.
- 1 July 2002
- Published by S. Karger AG in Hormone Research in Paediatrics
- Vol. 57 (Suppl. 2) , 83-87
Growth Problems in Children with Asthma
Growth problems are often seen in children with asthma. Rarely, these problems may be caused by poor asthma control. Negatively-deviating growth curves in asthmatic boys aged 8–15 years are often associated with a chronic delay in growth and puberty. Daily treatment with any dose of systemic corticosteroids suppresses the growth rate for as long as the treatment is maintained. The risk of growth rate suppression due to inhaled corticosteroids depends on the dose, administration regimen and delivery device. The risk becomes significant with ≧800 µg budesonide from a metered-dose inhaler with a spacer, and with ≧400 µg budesonide or fluticasone propionate from a dry-powder inhaler. Regardless of the treatment modality applied, all children with asthma should have their height growth measured at least every 6 months, and indications for endocrine work-up should follow general criteria for a growth-insufficient child.
- 1 January 2001
- p. 1487-90
Inhaled corticosteroids and growth.
Since inhaled corticosteroids may circulate systemically, a risk of growth suppression in asthmatic children treated with these drugs cannot be ruled out. When assessing the risk, specific drugs, delivery systems, doses, administration regimens, and compliance with treatment regimens must be considered. Although reassuring results have been reported, methodological flaws have meant that the published follow-up evaluations of final height may not be valid for the sound assessment of any growth effects of inhaled corticosteroids. Short-term studies suggest that twice-daily administration of budesonide 200-400 microg delivered from a metered-dose inhaler with a spacer, dry powder budesonide 200 microg, and fluticasone propionate 200 microg per day in children with mild asthma, are not associated with growth-rate effects. The risk may become significant with budesonide 800 microg administered via a metered-dose inhaler with a spacer, and with 400 microg from a dry powder inhaler. The risk of growth suppression can be reduced by dosing once daily in the morning. In children with severe asthma, high doses of inhaled corticosteroids may be potentially lifesaving and thus outweigh the potential risk of mild growth suppression.
- 1 January 2001
- p. 1487-90
Inhaled corticosteroids and growth.
Since inhaled corticosteroids may circulate systemically, a risk of growth suppression in asthmatic children treated with these drugs cannot be ruled out. When assessing the risk, specific drugs, delivery systems, doses, administration regimens, and compliance with treatment regimens must be considered. Although reassuring results have been reported, methodological flaws have meant that the published follow-up evaluations of final height may not be valid for the sound assessment of any growth effects of inhaled corticosteroids. Short-term studies suggest that twice-daily administration of budesonide 200-400 microg delivered from a metered-dose inhaler with a spacer, dry powder budesonide 200 microg, and fluticasone propionate 200 microg per day in children with mild asthma, are not associated with growth-rate effects. The risk may become significant with budesonide 800 microg administered via a metered-dose inhaler with a spacer, and with 400 microg from a dry powder inhaler. The risk of growth suppression can be reduced by dosing once daily in the morning. In children with severe asthma, high doses of inhaled corticosteroids may be potentially lifesaving and thus outweigh the potential risk of mild growth suppression.
- 1 May 2000
- Published by Springer Nature in BioDrugs
- Vol. 13 (5) , 347-357
Impact of Inhaled and Intranasal Corticosteroids on the Growth of Children
Since inhaled and intranasal corticosteroids may be systemically bioavailable, risk of growth suppression cannot be ruled out in children treated with these compounds. The mechanisms by which...
- 1 May 2000
- Published by Springer Nature in BioDrugs
- Vol. 13 (5) , 347-357
Impact of Inhaled and Intranasal Corticosteroids on the Growth of Children
Since inhaled and intranasal corticosteroids may be systemically bioavailable, risk of growth suppression cannot be ruled out in children treated with these compounds. The mechanisms by which...
- 1 January 2000
- Published by Wiley in Acta Paediatrica
- Vol. 89 (10) , 1158-1161
Systemic activity versus systemic adverse effects of nasal glucocorticoids in the treatment of allergic rhinitis
Treatment with nasal glucocorticoids may be associated with systemic activity, which can be detected by sensitive measures of basal adrenal cortisol secretion, bone turnover and short-term growth (knemometry). The detection of systemic activity, however, does not imply that nasal glucocorticoids cause serious adverse systemic effects, such as an inability of the adrenals to react to physiological stress. Studies assessing the ability of the adrenal cortex to react to stimulation have found this to be intact. Long-term assessments of bone density and statural height are needed, and the possibility of additive effects of intranasal glucocorticoids in children receiving concomitant treatment with inhaled glucocorticoids has not yet been studied. Children on long-term treatment with intranasal glucocorticoids should be followed with height measurements every 6 mo.
- 1 January 2000
- Published by Wiley in Acta Paediatrica
- Vol. 89 (10) , 1158-1161
Systemic activity versus systemic adverse effects of nasal glucocorticoids in the treatment of allergic rhinitis
Treatment with nasal glucocorticoids may be associated with systemic activity, which can be detected by sensitive measures of basal adrenal cortisol secretion, bone turnover and short-term growth (knemometry). The detection of systemic activity, however, does not imply that nasal glucocorticoids cause serious adverse systemic effects, such as an inability of the adrenals to react to physiological stress. Studies assessing the ability of the adrenal cortex to react to stimulation have found this to be intact. Long-term assessments of bone density and statural height are needed, and the possibility of additive effects of intranasal glucocorticoids in children receiving concomitant treatment with inhaled glucocorticoids has not yet been studied. Children on long-term treatment with intranasal glucocorticoids should be followed with height measurements every 6 mo.
- 1 January 1999
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 12 (6) , 863-6
Diurnal Rhythm in Serum Leptin
To assess 24-hour serum leptin levels in children. Five girls and two boys aged 10.4-13.6 (mean 12.2) years with pubertal stages I to III were studied. All children were healthy. A fasting blood sample was drawn at 08.00 hours, and thereafter samples were obtained every 2 hours throughout 24 hours until 08.00 hours the next morning. Serum leptin was measured by a specific radioimmunoassay. A statistically significant circadian variation was found in mean leptin profile expressed as a percentage of overall day mean (F-ratio =10.4; P<0.001) with trough and peak levels (+/- SEM) at 10.00 (6.55+/-1.52 mg/l) and 24.00 hours (10.99+/-2.34 mg/l), respectively. In normal children serum leptin levels exhibit a nocturnal increase and a decrease during the morning. The nocturnal rise may represent a time lagged stimulating effect of insulin. The diurnal rhythm needs to be considered when serum leptin is assessed in clinical studies.
- 1 January 1999
- Published by Walter de Gruyter GmbH in Journal of Pediatric Endocrinology and Metabolism
- Vol. 12 (6) , 863-6
Diurnal Rhythm in Serum Leptin
To assess 24-hour serum leptin levels in children. Five girls and two boys aged 10.4-13.6 (mean 12.2) years with pubertal stages I to III were studied. All children were healthy. A fasting blood sample was drawn at 08.00 hours, and thereafter samples were obtained every 2 hours throughout 24 hours until 08.00 hours the next morning. Serum leptin was measured by a specific radioimmunoassay. A statistically significant circadian variation was found in mean leptin profile expressed as a percentage of overall day mean (F-ratio =10.4; P<0.001) with trough and peak levels (+/- SEM) at 10.00 (6.55+/-1.52 mg/l) and 24.00 hours (10.99+/-2.34 mg/l), respectively. In normal children serum leptin levels exhibit a nocturnal increase and a decrease during the morning. The nocturnal rise may represent a time lagged stimulating effect of insulin. The diurnal rhythm needs to be considered when serum leptin is assessed in clinical studies.
- 1 January 1999
- Published by Taylor & Francis in Journal of Asthma
- Vol. 36 (6) , 477-486
Measures of Hypothalamic-Pituitary-Adrenal Function in Patients with Asthma Treated with Inhaled Glucocorticoids: Clinical and Research Implications
In asthmatic patients treated with inhaled glucocorticoids there may be a risk of suppression of hypothalamic-pituitary-adrenal (HPA) function. The aim of the present study was to review peer-refereed data on HPA function in asthmatic patients taking inhaled glucocorticoids, and to discuss the value of HPA function measures in clinical practice and research. There is no evidence that inhaled glucocorticoids in recommended doses cause clinically significant HPA insufficiency. If sensitive measures of basal adrenal activity are used, however, dose-related suppressive effects with specific drugs and application systems can be detected. In adults, fluticasone propionate appears to be more potent than budesonide or triamcinolone acetonide in suppressing measures of basal adrenal activity. Measures of basal adrenal activity are useful in clinical trials that assess and compare systemic activity of specific drugs, application devices, and administration regimens, but have no place in the management of asthma.
- 1 January 1999
- Published by Taylor & Francis in Journal of Asthma
- Vol. 36 (6) , 477-486
Measures of Hypothalamic-Pituitary-Adrenal Function in Patients with Asthma Treated with Inhaled Glucocorticoids: Clinical and Research Implications
In asthmatic patients treated with inhaled glucocorticoids there may be a risk of suppression of hypothalamic-pituitary-adrenal (HPA) function. The aim of the present study was to review peer-refereed data on HPA function in asthmatic patients taking inhaled glucocorticoids, and to discuss the value of HPA function measures in clinical practice and research. There is no evidence that inhaled glucocorticoids in recommended doses cause clinically significant HPA insufficiency. If sensitive measures of basal adrenal activity are used, however, dose-related suppressive effects with specific drugs and application systems can be detected. In adults, fluticasone propionate appears to be more potent than budesonide or triamcinolone acetonide in suppressing measures of basal adrenal activity. Measures of basal adrenal activity are useful in clinical trials that assess and compare systemic activity of specific drugs, application devices, and administration regimens, but have no place in the management of asthma.
- 1 January 1998
- Published by Wiley in Pediatric Dermatology
- Vol. 15 (1) , 7-11
Knemometry in children with atopic dermatitis treated with topical glucocorticoids.
Recently the knemometer, a lower leg length measuring device, has been introduced for sensitive assessment of systemic activity of exogeneous glucocorticoids in children. The aim of this study was to assess by means of knemometry whether the topical glucocorticoid budesonide affects short-term growth in children with atopic dermatitis. Fourteen children 5 to 12 years old were studied in an open longitudinal trial with three periods of 2 weeks duration. In periods 1 (run-in) and 3 (run-out), the children were treated with emollient. In period 2, budesonide cream 0.025% was followed by emollient twice daily to all of the body except the face. Eczema was evaluated according to a score based on extent and activity. Knemometry was performed twice weekly. Compared to the run-in and run-out periods the mean growth rate during budesonide treatment was reduced by 0.11 mm/wk (p > .05) and 0.40 mm/wk (p < .05), respectively. The mean growth rate during run-out was increased by 0.29 mm/wk as compared to run-in (p < .05). Compared to run-in the mean severity indices during budesonide treatment and run-out were reduced by 1.55 (p < .05) and 1.55 points (p <.05), respectively. The concomitant variations in lower leg growth rate and disease activity suggest that short-term treatment with topical glucocorticoids may provide a better growth potential during the weeks after withdrawal of the treatment. Whether this is due to improved disease control needs further study. Being a noninvasive method, knemometry may be useful for comparing different topical glucocorticoids and administration regimens in children in whom vasoconstrictor assays are difficult.
- 1 January 1998
- Published by Wiley in Pediatric Dermatology
- Vol. 15 (1) , 7-11
Knemometry in children with atopic dermatitis treated with topical glucocorticoids.
Recently the knemometer, a lower leg length measuring device, has been introduced for sensitive assessment of systemic activity of exogeneous glucocorticoids in children. The aim of this study was to assess by means of knemometry whether the topical glucocorticoid budesonide affects short-term growth in children with atopic dermatitis. Fourteen children 5 to 12 years old were studied in an open longitudinal trial with three periods of 2 weeks duration. In periods 1 (run-in) and 3 (run-out), the children were treated with emollient. In period 2, budesonide cream 0.025% was followed by emollient twice daily to all of the body except the face. Eczema was evaluated according to a score based on extent and activity. Knemometry was performed twice weekly. Compared to the run-in and run-out periods the mean growth rate during budesonide treatment was reduced by 0.11 mm/wk (p > .05) and 0.40 mm/wk (p < .05), respectively. The mean growth rate during run-out was increased by 0.29 mm/wk as compared to run-in (p < .05). Compared to run-in the mean severity indices during budesonide treatment and run-out were reduced by 1.55 (p < .05) and 1.55 points (p <.05), respectively. The concomitant variations in lower leg growth rate and disease activity suggest that short-term treatment with topical glucocorticoids may provide a better growth potential during the weeks after withdrawal of the treatment. Whether this is due to improved disease control needs further study. Being a noninvasive method, knemometry may be useful for comparing different topical glucocorticoids and administration regimens in children in whom vasoconstrictor assays are difficult.