Charles A. Taylor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Charles A. Taylor has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Christopher K. Zarins
Department of Surgery, Stanford University Medical Center, Stanford, CA 95305, USA
5 shared publications David H. Liang
2 shared publications- Mary T. Draney
Department of Mechanical Engineering, Stanford University, Stanford, California 94305-5431, USA
2 shared publications - Aaron S. Wang
Department of Bioengineering, Stanford University, Stanford, CA 94305-5233, USA
1 shared publication - Aaron S. Wang
Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
1 shared publication Brooke N. Steele
Department of Mechanical Engineering, Stanford University, Stanford, California, USA
1 shared publication
Latest Publications
- 30 April 2012
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 38 (4) , 692-701
Validation of a Power Law Model in Upper Extremity Vessels: Potential Application in Ultrasound Bleed Detection
- 30 April 2012
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 38 (4) , 692-701
Validation of a Power Law Model in Upper Extremity Vessels: Potential Application in Ultrasound Bleed Detection
- 15 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (12) , 2870-2875
Power Law as a Method for Ultrasound Detection of Internal Bleeding: In Vivo Rabbit Validation
New detection methods for vascular injuries can augment the usability of an ultrasound (US) imager in trauma settings. The goal of this study was to evaluate a potential-detection strategy for internal bleeding that employs a well-established theoretical biofluid model, the power law. This law characterizes normal blood-flow rates through an arterial tree by its bifurcation geometry. By detecting flows that deviate from the model, we hypothesized that vascular abnormalities could be localized. We devised a bleed metric, flow-split deviation (FSD), that quantified the difference between patient and model blood flows at vessel bifurcations. Femoral bleeds were introduced into ten rabbits (~5 kg) using a cannula attached to a variable pump. Different bleed rates (0% as control, 5%, 10%, 15%, 20%, 25%, and 30% of descending aortic flow) were created at two physiological states (rest and elevated state with epinephrine). FSDs were found by US imaging the iliac arteries. Our bleed metric demonstrated good sensitivity and specificity at moderate bleed rates; area under receiver-operating characteristic curves were greater than 0.95 for bleed rates 20% and higher. Thus, FSD was a good indicator of bleed severity and may serve as an additional tool in the US bleed detection.
- 15 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (12) , 2870-2875
Power Law as a Method for Ultrasound Detection of Internal Bleeding: In Vivo Rabbit Validation
New detection methods for vascular injuries can augment the usability of an ultrasound (US) imager in trauma settings. The goal of this study was to evaluate a potential-detection strategy for internal bleeding that employs a well-established theoretical biofluid model, the power law. This law characterizes normal blood-flow rates through an arterial tree by its bifurcation geometry. By detecting flows that deviate from the model, we hypothesized that vascular abnormalities could be localized. We devised a bleed metric, flow-split deviation (FSD), that quantified the difference between patient and model blood flows at vessel bifurcations. Femoral bleeds were introduced into ten rabbits (~5 kg) using a cannula attached to a variable pump. Different bleed rates (0% as control, 5%, 10%, 15%, 20%, 25%, and 30% of descending aortic flow) were created at two physiological states (rest and elevated state with epinephrine). FSDs were found by US imaging the iliac arteries. Our bleed metric demonstrated good sensitivity and specificity at moderate bleed rates; area under receiver-operating characteristic curves were greater than 0.95 for bleed rates 20% and higher. Thus, FSD was a good indicator of bleed severity and may serve as an additional tool in the US bleed detection.
- Open Access
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 286-295
Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: In vivo validation in the porcine aorta
Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity‐based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC‐MRI and an implanted coil and were then time‐integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity‐based and marker‐based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly. Magn Reson Med 52:286–295, 2004.
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 286-295
Open AccessQuantification of vessel wall motion and cyclic strain using cine phase contrast MRI: In vivo validation in the porcine aorta
Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity‐based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC‐MRI and an implanted coil and were then time‐integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity‐based and marker‐based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly. Magn Reson Med 52:286–295, 2004.
- 1 January 1999
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 4 (5) , 231-247
Predictive medicine: Computational techniques in therapeutic decision-making
The current paradigm for surgery planning for the treatment of cardiovascular disease relies exclusively on diagnostic imaging data to define the present state of the patient, empirical data to evaluate the efficacy of prior treatments for similar patients, and the judgement of the surgeon to decide on a preferred treatment. The individual variability and inherent complexity of human biological systems is such that diagnostic imaging and empirical data alone are insufficient to predict the outcome of a given treatment for an individual patient. We propose a new paradigm of predictive medicine in which the physician utilizes computational tools to construct and evaluate a combined anatomidphysiologic model to predict the outcome of alternative treatment plans for an individual patient. The predictive medicine paradigm is implemented in a software system developed for Simulation-Based Medical Planning. This system provides an integrated set of tools to test hypotheses regarding the effect of alternate treatment plans on blood flow in the cardiovascular system of an individual patient. It combines an internet-based user interface developed using Java and VRML, image segmentation, geometric solid modeling, automatic finite element mesh generation, computational fluid dynamics, and scientific visualization techniques. This system is applied to the evaluation of alternate, patient-specific treatments for a case of lower extremity occlusive cardiovascular disease.
- 1 January 1999
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 4 (5) , 231-247
Predictive medicine: Computational techniques in therapeutic decision-making
The current paradigm for surgery planning for the treatment of cardiovascular disease relies exclusively on diagnostic imaging data to define the present state of the patient, empirical data to evaluate the efficacy of prior treatments for similar patients, and the judgement of the surgeon to decide on a preferred treatment. The individual variability and inherent complexity of human biological systems is such that diagnostic imaging and empirical data alone are insufficient to predict the outcome of a given treatment for an individual patient. We propose a new paradigm of predictive medicine in which the physician utilizes computational tools to construct and evaluate a combined anatomidphysiologic model to predict the outcome of alternative treatment plans for an individual patient. The predictive medicine paradigm is implemented in a software system developed for Simulation-Based Medical Planning. This system provides an integrated set of tools to test hypotheses regarding the effect of alternate treatment plans on blood flow in the cardiovascular system of an individual patient. It combines an internet-based user interface developed using Java and VRML, image segmentation, geometric solid modeling, automatic finite element mesh generation, computational fluid dynamics, and scientific visualization techniques. This system is applied to the evaluation of alternate, patient-specific treatments for a case of lower extremity occlusive cardiovascular disease.
- 31 July 1997
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 8 (4) , 713-715
Modelling of Blood Vessels
- 31 July 1997
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 8 (4) , 713-715
Modelling of Blood Vessels
- 1 January 1996
- Published by AIP Publishing in Computers in Physics
- Vol. 10 (3) , 224
Computational Investigations in Vascular Disease
- 1 January 1996
- Published by AIP Publishing in Computers in Physics
- Vol. 10 (3) , 224
Computational Investigations in Vascular Disease