Latest Publications

  • The Effect of an Adhesive External Nasal Dilator Strip on the Inspiratory Nasal Airflow

    by Erdal Seren

    Background: We studied the affect of an adhesive external nasal dilator strip (ENDS) on the inspiratory nasal airflow. A prospective study was performed. Methods: Twenty-two healthy volunteers were enrolled in the study. All volunteers analyzed the inspiratory nasal sound samples before and while wearing a commercially available ENDS. This nasal sound analysis includes the spectral analysis and average sound intensities in low frequency (Lf), medium frequency (Mf), and high frequency (Hf). Results: In the sound analyses, an increase was found in sound intensity at Hf when the nasal strips were not worn whereas a decrease was found in sound intensity at Hf when the nasal strips were on. Conclusions: Changes in the nasal geometry of the anterior part of the nose by wearing nasal strips affects the pattern of nasal airflow and transforms it into a laminar pattern.


  • Open Access

    A New Surgical Method of Dynamic Nasal Valve Collapse

    by Erdal Seren

    The nasal valve area represents the narrowest segment of the nasal airway. It is defined as the area bounded by the caudal end of the upper lateral cartilage, cartilaginous nasal septum, pyriform aperture, floor of the nose, and head of the inferior turbinate.1,2 The nasal valve, which is a portion of the nasal valve area, is the area of highest airway resistance. The nasal valve angle is the angle between the upper lateral cartilage and the nasal septum.1 Anatomical studies have shown that this angle classically ranges between 10° and 15° in the nose of white individuals. One of the most common causes of nasal obstruction is internal valve collapse.2


  • Web-Based Hearing Screening Test

    by Erdal Seren

    This article describes a Web-based hearing screening system developed for real-time application via Internet and compares efficacy with conventional screening. The present prospective study used 36 adult participants in a double-blind study of two different systems: a conventional audiometer and a Web-based hearing screening test. The audiometric thresholds assessed by these two systems varied by no more than 1.78 dB for air conduction. The results demonstrated the feasibility of this Web-based hearing screening system. This Web-based system can be used effectively and easily in many locations that have Internet access but no local audiologists. The system makes audiometric measurements easily accessible for the public by providing a cost-effective solution based on the software for testing hearing installed in local personal computers or in network servers.


  • Effect of the Radiofrequency Volumetric Tissue Reduction of Inferior Turbinate on Expiratory Nasal Sound Frequency

    by Erdal Seren

    Background: We sought to evaluate the short-term efficacy of radiofrequency volumetric tissue reduction (RFVTR) in treatment of inferior turbinate hypertrophy (TH) as measured by expiratory nasal sound spectra. In our study, we aimed to investigate the Odiosoft-rhino (OR) as a new diagnostic method to evaluate the nasal airflow of patients before and after RFVTR. Methods: In this study, we have analyzed and recorded the expiratory nasal sound in patients with inferior TH before and after RFVTR. This analysis includes the time expanded waveform, the spectral analysis with time averaged fast Fourier transform (FFT), and the waveform analysis of nasal sound. Results: We found an increase in sound intensity at high frequency (Hf) in the sound analyses of the patients before RFVTR and a decrease in sound intensity at Hf was found in patients after RFVTR. Conclusion: This study indicates that RFVTR is an effective procedure to improve nasal airflow in the patients with nasal obstruction with inferior TH. We found significant decreases in the sound intensity level at Hf in the sound spectra after RFVTR. The OR results from the 2000- to 4000-Hz frequency (Hf) interval may be more useful in assessing patients with nasal obstruction than other frequency intervals. OR may be used as a noninvasive diagnostic tool to evaluate the nasal airflow.


  • Effect of Nasal Valve Area on Inspirator Nasal Sound Spectra

    by Erdal Seren

    OBJECTIVE: We have researched the effects of nasal valve area on the inspiratory nasal sound spectra in this study.STUDY DESIGN AND SETTING: We have spectral analyzed and recorded the inspiratory nasal sound in 22 healthy people with and without the Cottle maneuver.RESULTS: We have found an increase in sound intensity at high frequency in the sound analyses of the subjects without the Cottle maneuver; whereas, a decrease in sound intensity at high frequency was found in subjects with the Cottle maneuver.CONCLUSIONS: The nasal valve area plays an important role in the transformation of the nasal airflow from a laminar pattern to a more turbulent one. This condition affects nasal sound spectra and produces a marked shift upward in frequencies in the spectra. This method may be a new way of evaluating the nasal valve area.EBM rating: C‐4© 2006 American Academy of Otolaryngology–Head and Neck Surgery Foundation, Inc. All rights reserved.


  • Web-Based Analysis of Nasal Sound Spectra

    by Erdal Seren

    The spectral analysis of the nasal sound is an indicator of the nasal airflow pattern. We investigated a new technique for nasal sound analysis via Internet. This study includes 27 patients and 22 healthy people. Patients were treated by septoplasty operation for septal deviation. Postoperation 10th day, this technique was applied to follow nasal airflow course. The patients recorded the nasal sound by microphone into the computer as a .wav file and sent us via internet, all those records were evaluated by us. The results were sent back to themselves. The 11 patients who had nasal obstruction symptoms (group A) were called to the hospital to check. In the nasal sound analyses e-mails of those patients, the sound intensity was at high frequencies (2–4 kHz, 4–6 kHz) above 30 dB, but low (500–1000 Hz) and medium frequencies (1–2 kHz), are below then 10 dB. In the patients without nasal obstruction symptom (group B), the sound intensity was at high frequencies below 10 dB, but low and medium frequencies are above 20 dB. There was a statistically significant difference in sound intensity between group A and group B. In the endoscopical examination of those obstructions, which decreases the nasal airway, crusting formation in the nasal cavity was found. Web-based nasal sound analysis is an important method to follow the postoperative course and the nasal airflow evaluation. The new method will save time and money, avoiding a return visit to the hospital unnecessarily.