    Diagnostic ability of macular nerve fiber layer thickness measured by swept-source optical coherence tomography in preperimetric glaucoma

    by Shih-Jung Yeh, Yi-Wen Su, Mei-Ju Chen

    Background: We evaluated the diagnostic ability of macula retinal nerve fiber layer (mRNFL) thickness in preperimetric glaucoma (PPG) patients. Methods: This prospective study included 83 patients with PPG and 83 age- and refractive error-matched normal control subjects. PPG was defined as a localized RNFL defect corresponding to glaucomatous optic disc changes with a normal visual field test. We used spectral-domain (SD) optical coherence tomography (OCT) to measure the circumpapillary RNFL (cpRNFL) thickness and macular ganglion cell-inner plexiform layer (GCIPL) thickness. Swept-source (SS) OCT was used to measure cpRNFL thickness, macular ganglion cell layer + inner plexiform layer (IPL) thickness (GCL+), and macular ganglion cell layer + IPL+ mRNFL thickness (GCL++). The mRNFL thickness was defined as GCL++ minus GCL+. To evaluate the diagnostic power of each parameter, the area under the receiver operating characteristics curve (AUROC) was analyzed to differentiate PPG from the normal groups. Results: Using SD-OCT, all GCIPL parameters and most cpRNFL parameters, except at the nasal and temporal quadrant, were significantly lower in PPG versus normal controls. PPG eyes had significantly smaller values than normal controls for all cpRNFL and GCL parameters measured by SS-OCT, except mRNFL at the superonasal area. The inferotemporal GCL++ had the largest AUROC value (0.904), followed by inferotemporal GCL+ (0.882), inferotemporal GCIPL thickness (0.871), inferior GCL++ (0.866), inferior cpRNFL thickness by SS-OCT (0.846), inferior cpRNFL thickness by SD-OCT (0.841), and inferotemporal mRNFL thickness (0.840). The diagnostic performance was comparable between inferotemporal mRNFL thickness and the best measures of GCL (inferotemporal GCL++, p = 0.098) and cpRNFL (inferior cpRNFL thickness by SS-OCT, p = 0.546). Conclusion: The diagnostic ability of mRNFL thickness was comparable to that of the best measures of cpRNFL and GCL analysis for eyes with PPG. Therefore, mRNFL thickness could be a new parameter to detect early structural changes in PPG.


  • Open Access

    Comparison of the iCare, Tono-Pen, non-contact airpuff, and Goldmann applanation tonometers in eyes with corneal edema after penetrating keratoplasty

    by Shih-Jung Yeh, Ko-Hua Chen, Tung-Mei Kuang, Catherine Jui-Ling Liu, Mei-Ju Chen

    Background: To compare the utility of the iCare, Tono-Pen, and non-contact airpuff (NCT) tonometers with the Goldmann applanation tonometer (GAT) for measuring intraocular pressure (IOP) in patients with corneal edema after penetrating keratoplasty (PKP) and to assess the effects of central corneal thickness (CCT) and corneal curvature (CC) on IOP measurements. Methods: Thirty-two eyes of 27 patients with corneal edema after PKP due to corneal abnormalities and 43 control eyes of 30 patients with normal corneas were recruited. Before IOP measurements, all patients underwent a baseline examination, including auto-refraction, keratometry, slit lamp biomicroscopy, and CCT measurement. IOP was measured using the devices in the same order: first the NCT, followed by the iCare, Tono-Pen, and GAT. The differences between the iCare, Tono-Pen, NCT, and GAT were calculated with repeated-measures analysis of variance. The Bland-Altman method was used to assess the agreement between the iCare, Tono-Pen, and NCT versus the GAT. The influences of CCT and CC on IOP measurement were evaluated by correlation analysis using Pearson’s correlation coefficient. Results: Mean IOP measurements were significantly higher with the NCT and Tono-Pen than with the GAT in the PKP and control groups. When compared with GAT, iCare showed significantly higher IOP readings in the control group, but the IOP readings did not differ between the iCare and GAT in the PKP group. Poor agreement was noted between the NCT and GAT in both groups. The Tono-Pen showed clinically acceptable agreement with GAT in control eyes and poor agreement in PKP eyes. The agreement between the iCare and GAT appeared to be clinically acceptable in both groups. Correlation analysis of the results from control eyes showed that the IOP measurements with the GAT and NCT were weakly related to CCT and moderately correlated with CC. The iCare IOP readings were weakly correlated with CCT and CC. Conclusion: In the PKP group, the NCT and Tono-Pen significantly overestimated IOP, whereas the iCare IOP readings were similar to those obtained using the GAT. Poor agreement was noted between the NCT and GAT as well as between the Tono-Pen and GAT, but the iCare showed clinically acceptable agreement with GAT. In normal corneas, the GAT, NCT, and iCare were affected by CCT and CC. The iCare tonometer was less affected by corneal edema than were the NCT and the Tono-Pen. The iCare appears to be a useful device for IOP measurement in eyes with corneal edema after PKP.


  • Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length

    by Mei-Ju Chen, Yin-Tzu Liu, Chia-Chen Tsai, Yen-Cheng Chen, Ching-Kuang Chou, Shu-Mei Lee

    To determine the relationship between central corneal thickness (CCT), refractive error, corneal curvature, anterior chamber depth and axial length in normal Taiwanese Chinese adults. Five hundred normal Taiwanese Chinese patients aged 40-80 years were recruited for the study. Measurement procedures included CCT, refractive error, corneal curvature, anterior chamber depth and axial length. Exclusion criteria were previous ocular surgery, glaucoma, trauma history, external eye disease, and previous contact lens use. The relationships among parameters were tested using Pearson's correlation and linear regression analysis. The median CCT was 555 +/- 27 mum for males and 553 +/- 30 mum for females. Eyes with more myopic refractive error tended to have greater axial length (r = -0.645, p < 0.001). Eyes with axial elongation tended to have flatter cornea (r = -0.502, p < 0.001) and deeper anterior chamber (r = 0.651, p < 0.001). There were no significant correlations between the CCT and refractive error (r = -0.034, p = 0.445), corneal curvature (r = 0.013, p = 0.770), anterior chamber depth (r = 0.023, p = 0.614) and axial length (r = -0.053, p = 0.223). CCT was not associated with refractive error, corneal curvature, anterior chamber depth and axial length. CCT is an independent factor unrelated to other ocular parameters.


  • The Long-term Effect of Nd:YAG Laser Iridotomy on Intraocular Pressure in Taiwanese Eyes with Primary Angle-closure Glaucoma

    by Mei-Ju Chen, Ching-Yu Cheng, Ching-Kuang Chou, Catherine J.L. Liu, Wen-Ming Hsu

    To investigate the long-term effect of Nd:YAG laser iridotomy on intraocular pressure (IOP) in Taiwanese eyes with primary angle-closure glaucoma (PACG). The medical records of 81 patients (130 eyes) who were diagnosed with PACG and who had undergone Nd:YAG laser iridotomy between 1998 and 2002 were reviewed. According to the presence of symptomatic glaucoma attack, eyes were divided into an acute angle-closure glaucoma (AACG) group and chronic angle-closure glaucoma (CACG) group. In the AACG group, the acute episode was treated and resolved after Nd:YAG laser iridotomy. These eyes were diagnosed to have or developed glaucoma during the follow-up period. All patients were followed-up for at least 24 months. The presenting features, treatment and IOP during the follow-up period were analyzed. The mean follow-up period was 44.1 +/- 17.8 months (median, 36 months). There were 27 eyes (from 25 patients) in the AACG group. Only 2 eyes (7.4%) did not require any treatment after Nd:YAG laser iridotomy. Eleven eyes (40.7%) eventually underwent filtering surgery at a mean of 3.2 months (median, 3 months) after Nd:YAG laser iridotomy. There were 103 eyes (from 56 patients) in the CACG group. Eighty-five eyes (82.5%) required further medical treatment, of which 21 eyes (20.4%) eventually received filtering surgery at a mean of 9.8 months (median, 5 months) after Nd:YAG laser iridotomy. For most Taiwanese eyes with PACG after Nd:YAG laser iridotomy, additional medicine and surgery are required in the long term. Eyes in the AACG group needed more surgical intervention than those in the CACG group.


  • Comparison of the Effects of Latanoprost and Bimatoprost on Intraocular Pressure in Chronic Angle-Closure Glaucoma

    by Mei-Ju Chen, Yen-Cheng Chen, Ching-Kuang Chou, Wen-Ming Hsu

    The aim of this study was to compare the intraocular pressure (IOP)-lowering effect of latanoprost and bimatoprost as primary therapy in patients with chronic angle-closure glaucoma (CACG) after peripheral iridotomy. Eighty-two (82) consecutive CACG patients with an IOP greater than 19 mmHg after a peripheral iridotomy were recruited. CACG was defined as chronic elevated IOP, glaucomatous optic neuropathy, and a corresponding visual field defect in eyes with occludable angle and peripheral anterior synechiae on gonioscopy. Patients were randomly assigned to two groups based on daily treatment with either latanoprost 0.005% or bimatoprost 0.03% in the evening for 12 weeks. The IOP was measured at 9 AM and 4 PM on the same day at baseline and also at 4, 8, and 12 weeks. Between-group differences in mean diurnal IOP and IOP reduction were analyzed. After 12 weeks of treatment, mean IOP for both the latanoprost and bimatoprost groups was significantly reduced when compared to the baseline value (21.6 +/- 1.9 to 16.4 +/- 2.5 mmHg and 22.1 +/- 2.0 to 16.9 +/- 2.4 mmHg, respectively; P < 0.001 for both). There was no significant difference in IOP reduction between the two treatment groups (P = 0.40). At 4 and 8 weeks, the IOP changes from baseline were statistically significant at both times for both drugs (all P < 0.001). Both latanoprost and bimatoprost significantly reduced IOP in CACG patients who were inadequately treated by laser peripheral iridotomy.


  • Comparison of the Effects of Latanoprost and Travoprost on Intraocular Pressure in Chronic Angle-Closure Glaucoma

    by Mei-Ju Chen, Yen-Cheng Chen, Ching-Kuang Chou, Wen-Ming Hsu

    The aim of this study was to compare the intraocular pressure (IOP)-lowering effect of latanoprost and travoprost as primary therapy in patients with chronic angle-closure glaucoma (CACG) after peripheral iridotomy. Seventy-three (73) CACG patients with IOP>19 mmHg after peripheral iridotomy and without previous antiglaucoma medication were consecutively recruited. CACG was defined as the presence of chronically elevated IOP, glaucomatous optic neuropathy, and a corresponding visual field defect in eyes with occludable angle and peripheral anterior synechiae on gonioscopy. Patients were randomly assigned to 2 groups, based on daily treatment with either latanoprost 0.005% or travoprost 0.004% in the evening for 12 weeks. The IOP was measured at 9 AM and 4 PM at baseline and at 4, 8, and 12 weeks. Between-group differences in mean diurnal IOP and IOP reduction were analyzed. After 12 weeks of treatment, mean IOP for both the latanoprost and travoprost groups was significantly reduced, when compared to the baseline IOP (from 21.3+/-1.8 mmHg to 16.0+/-2.3 mmHg and 21.7+/-1.7 to 16.7+/-2.2 mmHg; P<0.001 for both). There was no significant difference in IOP reduction between the 2 treatment groups (P=0.19). At 4 and 8 weeks, the IOP changes from the baseline were statistically significant at all time points for both drugs (all P<0.001). Both latanoprost and travoprost significantly reduced IOP in our sample of CACG patients after peripheral iridotomy.


  • Effects of Bimatoprost 0.03% on Ocular Hemodynamics in Normal Tension Glaucoma

    by Mei-Ju Chen, Ching-Yu Cheng, Yen-Cheng Chen, Ching-Kuang Chou, Wen-Ming Hsu

    The aim of this study was to investigate the effects of bimatoprost 0.03% on ocular hemodynamics in patients with normal tension glaucoma (NTG). Twenty-two (22) patients with NTG were consecutively recruited. After basic eye examination and diurnal intraocular pressure (IOP) measurement, color Doppler imaging was used to measure the peak systolic and end diastolic velocities and resistive index of the central retinal, lateral posterior ciliary, and medial posterior ciliary arteries. Patients received bimatoprost 0.03% for 4 weeks, and these measurements were then repeated. The worse eye of each NTG patient was used in the statistical analysis. Bimatoprost 0.03% significantly reduced mean IOP from 15.1 +/- 3.8 mmHg at baseline to 12.0 +/- 2.9 mmHg after treatment in our sample of NTG patients (P < 0.001). No significant changes in blood velocities or resistance indices were observed in the retrobulbar vessels after the 4-week treatment. Topical bimatoprost 0.03% significantly reduced IOP in our NTG patients without causing significant hemodynamic changes in the retrobulbar vessels.


    • 1 May 2003
      • Vol. 66  (5) , 276-81

    The efficacy and safety of brimonidine 0.2% compared with timolol 0.5% in glaucoma: a randomized clinical trial on Taiwanese patients.

    by Mei-Ju Chen, Joe Ching-Kuang Chou, Wen-Ming Hsu, Jorn-Hon Liu

    Brimonidine is a highly selective alpha-2 adrenergic receptor agonist with intraocular pressure (IOP) reducing effect. We conducted this study in Taiwan to compare the safety and efficacy ofbrimonidine 0.2% with timolol 0.5% for the treatment of glaucoma. A prospective, randomized, single-masked, 1-month clinical efficacy and safety trial was conducted from March to September 2000. Forty glaucoma patients were enrolled--29 in the brimonidine group and 11 in the timolol group. Patients instilled their study medications twice daily for 4 weeks, and were followed at baseline visit, weeks 2 and 4. Demographic data, reduction of IOP, safety and adverse events were obtained and analyzed. Both drugs showed sustained ocular hypotensive efficacy in the study period. At baseline, the mean IOP was 24.48 +/- 2.29 mmHg in the brimonidine group and 23.32 +/- 0.82 mmHg in the timolol group. The IOP readings after treatment were significantly lower than their baseline levels in both groups at all visits (p < 0.001). At peak, the mean decreases from the baseline IOP ranged from 5.22 +/- 0.30 mmHg to 6.96 +/- 0.33 mmHg for brimonidine and from 4.55 +/- 0.49 mmHg to 6.64 +/- 0.53 mmHg for timolol. At trough, the mean decreases from baseline ranged from 3.72 +/- 0.32 mmHg to 4.55 +/- 0.32 mmHg for brimonidine and 3.82 +/- 0.52 mmHg to 4.27 +/- 0.51 mmHg for timolol. No significant between-group differences were seen at peak or trough at all visits. The clinical success rate was 86.2% in the brimonidine group and 81.8% in the timolol group, making no statistically significant difference between them (p = 0.817). 17.2% of patients in brimonidine group and 9.0% patients in timolol group reported mild adverse events. Ocular allergy occurred in 10.3% of patients in brimonidine group. No significant changes in visual acuity, biomicroscopy or ophthalmoscopy were observed in both groups. Mean systolic and diastolic blood pressure remained relatively stable in both groups except in week 2 (p = 0.016) when brimonidine had lower systolic blood pressure. However, brimonidine showed no significant difference in week 4 from baseline. The mean heart rate in the brimonidine group was relatively unchanged over the study period. Patients receiving timolol experienced statistically significant mean heart rate decreases from baseline (p = 0.020) in week 4. Topically applied twice daily for one month, brimonidine tartrate 0.2% has clinical effectiveness equivalent to timolol 0.5% in Taiwanese patients with glaucoma. It has a safe systemic profile with minimum effect on the heart.