RBRalf Brinkmann

Ralf Brinkmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ralf Brinkmann has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Reginald Birngruber

    Medical Laser Center Lübeck, 23562 Lübeck, Germany

    4 shared publications
  • Charles P. Lin

    Wellman Laboratories of Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114

    3 shared publications
  • Georg Schüle

    Medical Laser Center Lübeck, 23562 Lübeck, Germany

    2 shared publications
  • Johann Roider

    Department of Ophthalmology, University of Regensburg, Germany

    2 shared publications
  • Carsten Framme

    Medical Laser Center Lübeck, Germany

    1 shared publication
  • Christoph Hansen

    The authors are with the Medical Laser Center Lübeck GmbH, Peter-Monnik-Weg 4, D-23562 Lübeck, Germany

    1 shared publication

Latest Publications

    • 1 January 2006
      • No. 302,p. 51-69

    Selective retina therapy (SRT): a review on methods, techniques, preclinical and first clinical results.

    by R Brinkmann, J Roider, R Birngruber

    Selective retina therapy (SRT) is a new laser procedure for retinal diseases that are thought to be associated with a degradation of the retinal pigment epithelium (RPE). The aim of the irradiation is to selectively damage the RPE without affecting the neural retina, the photoreceptors and the choroid. Goal of the treatment is to stimulate RPE cell migration and proliferation into the irradiated areas in order to improve the metabolism at the diseased retinal sites. In a pilot study more than 150 patients with soft drusen, retinopathia centralis serosa (RCS) and macular edema were treated. The first 3-center international trial targets diabetic macular edema and branch vein occlusion. In this review, selective RPE effects are motivated and two modalities to achieve selective RPE effects will be introduced: a pulsed and a continuous wave scanning mode. The mechanism behind selective RPE-effects will be discussed reviewing in vitro results and temperature calculations. So far clinical SRT is performed by applying trains of 30 laser pulses from a Nd:YLF-Laser (527 nm, 1.7 micros, 100 Hz) to the diseased fundus areas. In the range of 450-800 mJ/cm(2) per pulse, RPE-defects in patients were proved angiographically by fluorescein or ICG-leakage. The selectivity with respect to surrounding highly sensitive tissue and the safety range of the treatment will be reviewed. With the laser parameters used neither bleeding nor scotoma, proved by microperimetry, were observed thus demonstrating no adverse effects to the choroid and the photoreceptors, respectively. During and after irradiation, it shows that the irradiated locations are ophthalmoscopically invisible, since the effects are very limited and confined to the RPE, thus a dosimetry control is demanded. We report on a non-invasive opto-acoustic on-line technique to monitor successful RPE-irradiation and compare the data to those achieved with standard angiography one-hour post treatment.


  • Mid-infrared laser-induced superheating of water and its quantification by an optical temperature probe.

    by Tobias Brendel, Ralf Brinkmann

    Free-running thulium laser pulses (Cr:Tm:YAG, λ = 2.01 μm, t p = 300 μs) were applied to a purified, degassed water sample and the resulting temperature rise was investigated by an optical temperature probe. The probe detected water reflectance index changes with temperature and also the onset of vaporization, which was found to occur in a superheat regime, at approximately 230 °C. The experimental data were compared with theoretical temperature calculations, and deviations of less than 20 °C were stated. The best agreement between theory and experiment was found for temperatures below 180 °C, defining by this the method’s high accuracy limit. In conclusion, both the optical temperature probe and the presented calculations can help to improve dosimetry in pulsed IR laser applications by precise temperature measurement and prediction.


  • Targeting of the retinal pigment epithelium (RPE) by means of a rapidly scanned continuous wave (CW) laser beam

    by Ralf Brinkmann, Norbert Koop, Mustafa Özdemir, Clemens Alt, Georg Schüle, Charles P. Lin, Reginald Birngruber

    Background and Objectives: Selective treatment of the retinal pigment epithelium (RPE) by repetitively applying green μs‐laser pulses is a new method for retinal diseases associated with a degradation of the RPE, which spares the neural retina. We investigated an alternative approach to realize repetitive μs‐laser exposure by rapidly scanning a continuous wave (CW)‐laser beam across the RPE.Study Design/Materials and Methods: An Ar+ laser beam (514 nm) with a diameter of 18.75 μm was repetitively scanned across porcine RPE samples in vitro providing an irradiation time of 1.6 μs per point on the central scan axis. RPE cell damage was investigated by means of the fluorescence viability assay Calcein‐AM.Results: The ED50 cell damage is 305 mJ/cm2 when applying 10 scans with a repetition rate of 500 Hz. The threshold decreases with the number of scans, a saturation was found at 135 mJ/cm2 with more than 500 exposures applied. The depth of focus in beam direction is 350 μm, defined by an increase of the threshold radiant exposure by 20%.Conclusions: Targeting of pigmented cells with high local resolution has been proved with a laser‐scanning device. Looking ahead selective RPE‐treatment, the adaptation of a laser‐scanning device on a slit‐lamp or into a modified retina angiograph seems to be an attractive alternative to the pulsed μs laser device. Lasers Surg. Med. 32:252–264, 2003.


  • Optical Tracing of Q-switched mid-IR Laser Induced Bubble Formation

    by Tobias Brendel, Ralf Brinkmann

    Q-switched TEM00 thulium laser (λ = 2.01µm, 300 ns FWHM) induced bubble dynamics at a silica-water interface were investigated. In particular, bubble dynamics far above the Threshold Radiant Exposure (TRE) for bubble formation were studied. At this, different silica surfaces (all of standard optical quality) were used, at which particular TREs were measured. Irradiation parameters like pulse duration or beam diameter were kept constant. As reported recently,1 every silica surface provides different nucleation sites for bubble formation and thus shows a specific TRE. By means of a sensitive optical detection device bubble lifetimes at the interface were monitored as a function of radiant exposure. Measurements were performed with maximum radiant exposures of 330 mJ/mm2 on four different silica surfaces. The TREs of the surfaces were preliminarily determined to lie between 38 mJ/mm2 and 95 mJ/mm2. Above 150 mJ/mm2, bubble lifetimes were measured to be independent of the surface used and its particular TRE. An explanation for this behavior was found by fast flash photographs of the onset of bubble formation, revealing vanishing differences in the heterogeneous nucleation with increasing radiant exposure.

  • Optoacoustic detection of selective RPE cell damage during µs-laser irradiation

    by Georg Schüle, Elke Joachimmeyer, Carsten Framme, Johann Roider, Reginald Birngruber, Ralf Brinkmann

    Objective: The selective damage of the retinal pigment epithelium (RPE) with repetitive µs laser pulses is a new technique for the treatment of several retinal diseases. RPE can selectively be damaged by simultaneously sparing off the adjacent photoreceptor tissue. Objective of this study is to investigate whether optoacoustic (OA) transients occurring during irradiation might be used to control the invisible treatment effect. Setup: A train of frequency doubled Nd:YLF laser pulses (527 nm, 1.7µs pulse length, 500Hz rep. rate) were applied via a laser slit lamp on porcine RPE samples. The acoustic transients were recorded with a broadband transducer. Results: At low radiant exposures (< 100 mJ/cm2) we found a bipolar pressure transient due to thermoelastic expansion of the RPE. The pressure waves from the individual pulses of one pulse train show nearly identical transients. The transients differ slightly from different sites on the sample. At higher radiant exposures (> 150 mJ/cm2), the OA transients differ from pulse to pulse within a pulse train, which can be attributed to microbubble formation around the strong absorbing melanosomes inside the RPE cells. FFT spectra of the OA transients show slight differences in the frequency spectrum with the different radiant exposures.

  • Open Access

    Origin of retinal pigment epithelium cell damage by pulsed laser irradiance in the nanosecond to microsecond time regimen

    by Ralf Brinkmann, Gereon Hüttmann, Jan Rögener, Johann Roider, Reginald Birngruber, Charles P. Lin


  • Beam-profile modulation of thulium laser radiation applied with multimode fibers and its effect on the threshold fluence to vaporize water

    by Ralf Brinkmann, Christoph Hansen

    The threshold fluences at which vaporization is initiated at the tip of a multimode fiber that is submerged in water were investigated when free-running and Q-switched thulium laser pulses (λ = 2.01 µm) were applied with different pulse energies. We focused on the quantification of temporal and spatial fluence modulations of the beam profile at the tip of a 400-µm fiber. The spatial and the temporal fluence peaks over the average fluence were measured to as high as 1.5 and 4 in the Q-switched mode, respectively, and 2.5 and 40 in the free-running mode, respectively. The fluence peaks significantly influence the vaporization process. An increase in the threshold fluence with increasing pulse energy was found for the Q-switched mode, but there was a decrease for the free-running mode. Pressure transients of the order of 1 kbar and temperatures higher than 200 °C were calculated for a 30-mJ Q-switched laser pulse at the onset of vaporization. Collecting all the data allowed us to trace the thermodynamic path of rapid heating and vaporization in a phase diagram of water.


  • Origin of retinal pigment epithelium cell damage by pulsed laser irradiance in the nanosecond to microsecond time regimen

    by Ralf Brinkmann, Johann Roider, Reginald Birngruber, Charles P. Lin

    Selective photodamage of the retinal pigment epithelium (RPE) is a new technique to treat a variety of retinal diseases without causing adverse effects to surrounding tissues such as the neural retina including the photoreceptors and the choroid. In this study, the mechanism of cell damage after laser irradiation was investigated. Single porcine RPE-melanosomes and RPE cells were irradiated with a Nd:YLF laser (wavelength lambda = 527 nm, adjustable pulse duration tau = 250 nsec-3 microsec) and a Nd:YAG laser (lambda = 532 nm, tau = 8 nsec). Fast flash photography was applied to observe vaporization at melanosomes in suspension. A fluorescence viability assay was used to probe the cells vitality. The threshold radiant exposures for vaporization around individual melanosomes and for ED50 cell damage are similar at 8-nsec pulse duration. Both thresholds increase with pulse duration; however, the ED50 cell damage radiant exposure is 40% lower at 3 microsec. Temperature calculations to model the onset of vaporization around the melanosomes are in good agreement with the experimental results when assuming a surface temperature of 150 degrees C to initiate vaporization and a homogeneous melanosome absorption coefficient of 8,000 cm(-1). Increasing the number of pulses delivered to RPE cells at a repetition rate of 500 Hz, the ED50 value decreases for all pulse durations. However, the behavior does not obey scaling laws such as the N 1/4 equation. The origin of RPE cell damage for single pulse irradiation up to pulse durations of 3 microsec can be described by a damage mechanism in which microbubbles around the melanosomes cause a rupture of the cell structure. The threshold radiant exposure for RPE damage decreases with increasing number of pulses applied.