Jana Sádecká
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jana Sádecká has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Pavel Májek
Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology, Radlinského 9, SK-812 37 Bratislava, Slovakia
9 shared publicationsKatarína Hroboňová
Department of Analytical Chemistry, Institution Faculty of Chemical and Food Technology, Slovak University of Technology, Bratislava, Slovakia
5 shared publicationsJana Tóthová
3 shared publicationsA. Kleinová
Department of Composite Materials, Polymer Institute, Slovak Academy of Sciences, Dúbravská cesta 9, 845 41 Bratislava, Slovak Republic
2 shared publications- Frantisek Cacho
Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37, Bratislava, Slovakia
2 shared publications M. Jakubíková
Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology, Radlinského 9, 812 37 Bratislava, Slovak Republic
2 shared publications
Latest Publications
- Open Access
- 1 December 2017
- Published by Walter de Gruyter GmbH in Nova Biotechnologica et Chimica
- Vol. 16 (2) , 132-137
Distinguishing between juniper-flavoured spirit drinks from different producers
A simple method for classifying juniper-flavoured spirit drinks is proposed based on the ratio of fluorescence intensity values in synchronous fluorescence spectra. Receiver operating curves (ROC) and linear discriminant analysis (LDA) were used to compute the performance of the classification. Significant differences in the fluorescence intensity ratios (I316/I287 and I324/I287) observed in the spectra recorded using wavelength difference 10 nm were evaluated by ROC analysis to identify cutoff values that gave ideal AUCs equal to one, thus allowing for 100% correct classification of the samples according to producer criteria. LDA showed that drinks of different producers could be distinguished (100% correct classification) on the basis of their differences in the fluorescence intensity ratios (I323/I287, I324/I287, I316/I287 and I325/I287). These results show that complete synchronous spectra are not required to discriminate between producers. Instead of them, fluorescence intensity could be measured at selected wavelengths.
- 1 December 2017
- Published by Walter de Gruyter GmbH in Nova Biotechnologica et Chimica
- Vol. 16 (2) , 132-137
Open AccessDistinguishing between juniper-flavoured spirit drinks from different producers
A simple method for classifying juniper-flavoured spirit drinks is proposed based on the ratio of fluorescence intensity values in synchronous fluorescence spectra. Receiver operating curves (ROC) and linear discriminant analysis (LDA) were used to compute the performance of the classification. Significant differences in the fluorescence intensity ratios (I316/I287 and I324/I287) observed in the spectra recorded using wavelength difference 10 nm were evaluated by ROC analysis to identify cutoff values that gave ideal AUCs equal to one, thus allowing for 100% correct classification of the samples according to producer criteria. LDA showed that drinks of different producers could be distinguished (100% correct classification) on the basis of their differences in the fluorescence intensity ratios (I323/I287, I324/I287, I316/I287 and I325/I287). These results show that complete synchronous spectra are not required to discriminate between producers. Instead of them, fluorescence intensity could be measured at selected wavelengths.
- Open Access
- 5 October 2016
- Published by IntechOpen
Fluorescence Spectroscopy for the Analysis of Spirit Drinks
Fluorescence Spectroscopy for the Analysis of Spirit Drinks | InTechOpen, Published on: 2016-10-05. Authors: Jana Sádecká, Veronika Uríčková and Michaela Jakubíková
- 5 October 2016
- Published by IntechOpen
Open AccessFluorescence Spectroscopy for the Analysis of Spirit Drinks
Fluorescence Spectroscopy for the Analysis of Spirit Drinks | InTechOpen, Published on: 2016-10-05. Authors: Jana Sádecká, Veronika Uríčková and Michaela Jakubíková
- Open Access
- 1 October 2016
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 9 (2) , 163-168
Determination of enantiomeric composition of fluoxetine by synchronous fluorescence spectrometry coupled with multivariate calibration in biological samples
This paper presents rapid and low cost analytical method for the determination of the fluoxetine enantiomeric composition in biological samples (urine). The combination of synchronous fluorescence spectrometry and inverse multivariate calibration methods was used. The chiral recognition of the fluoxetine was based on the creating of the diastereomeric complexes withβ-cyclodextrin. A net analytical signal of diastereomeric complexes was obtained by the addition of aliquot part of urine into calibration and validation sets. This step ensures the elimination of the urine matrix effect. The synchronous fluorescence spectra at the constant wavelength differences (Δλ) of 30 and 50 nm, based on RMS %RE values, were chosen for chemometric analysis. Principal component regression (PCR) and partial least square method (PLS) were compared to determine the enantiomeric composition. The most suitable results were provided by the PLS model constructed from the synchronous data at Δλ = 50 nm. The calculated figure of merit was used for validation of proposed method.
- 1 October 2016
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 9 (2) , 163-168
Open AccessDetermination of enantiomeric composition of fluoxetine by synchronous fluorescence spectrometry coupled with multivariate calibration in biological samples
This paper presents rapid and low cost analytical method for the determination of the fluoxetine enantiomeric composition in biological samples (urine). The combination of synchronous fluorescence spectrometry and inverse multivariate calibration methods was used. The chiral recognition of the fluoxetine was based on the creating of the diastereomeric complexes withβ-cyclodextrin. A net analytical signal of diastereomeric complexes was obtained by the addition of aliquot part of urine into calibration and validation sets. This step ensures the elimination of the urine matrix effect. The synchronous fluorescence spectra at the constant wavelength differences (Δλ) of 30 and 50 nm, based on RMS %RE values, were chosen for chemometric analysis. Principal component regression (PCR) and partial least square method (PLS) were compared to determine the enantiomeric composition. The most suitable results were provided by the PLS model constructed from the synchronous data at Δλ = 50 nm. The calculated figure of merit was used for validation of proposed method.
- 1 April 2016
- Published by Elsevier in Food Chemistry
- Vol. 196, 783-790
Classification of plum spirit drinks by synchronous fluorescence spectroscopy
- 1 April 2016
- Published by Elsevier in Food Chemistry
- Vol. 196, 783-790
Classification of plum spirit drinks by synchronous fluorescence spectroscopy
- Open Access
- 1 April 2015
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 8 (1) , 52-58
Determination of adulterants in adulterant-fruit spirit blends using excitation-emission matrix fluorescence spectroscopy
This study introduces a reliable method to detect adulteration of spirit drinks. Excitation-emission matrix (EEM) fluorescence in combination with parallel factor analysis (PARAFAC) and partial least squares (PLS) regression was used to determine the content of water and ethanol in adulterated fruit spirit samples. EEM fluorescence spectra recorded in the emission wavelength range of 315–450 nm and in the excitation wavelength range of 240–305 nm were used for PARAFAC. The model created using PARAFAC-PLS was able to predict the water and ethanol level in adulterated apple spirit with the root mean square error of prediction (RMSEP) values of 1.9 % and 1.8 %, respectively. Regarding adulterated plum spirit, the RMSEP values of 0.7 % and 3.5 % were obtained for water and ethanol, respectively. The aim of this work was to determine whether EEM-PARAFAC can be used to distinguish between plum and apple spirit. Better results were obtained for apple spirit and the method is useful also for water-apple spirit blends.
- 1 April 2015
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 8 (1) , 52-58
Open AccessDetermination of adulterants in adulterant-fruit spirit blends using excitation-emission matrix fluorescence spectroscopy
This study introduces a reliable method to detect adulteration of spirit drinks. Excitation-emission matrix (EEM) fluorescence in combination with parallel factor analysis (PARAFAC) and partial least squares (PLS) regression was used to determine the content of water and ethanol in adulterated fruit spirit samples. EEM fluorescence spectra recorded in the emission wavelength range of 315–450 nm and in the excitation wavelength range of 240–305 nm were used for PARAFAC. The model created using PARAFAC-PLS was able to predict the water and ethanol level in adulterated apple spirit with the root mean square error of prediction (RMSEP) values of 1.9 % and 1.8 %, respectively. Regarding adulterated plum spirit, the RMSEP values of 0.7 % and 3.5 % were obtained for water and ethanol, respectively. The aim of this work was to determine whether EEM-PARAFAC can be used to distinguish between plum and apple spirit. Better results were obtained for apple spirit and the method is useful also for water-apple spirit blends.
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1473-1478
Determination of Nitrates in Water Samples by In-Electrode Coulometric Titration in Copper Coated Porous Vitreous Carbon Electrode
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1473-1478
Determination of Nitrates in Water Samples by In-Electrode Coulometric Titration in Copper Coated Porous Vitreous Carbon Electrode
- 3 October 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 8 (5) , 1258-1267
Synchronous Fluorescence Spectroscopy for Rapid Classification of Fruit Spirits
- 3 October 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 8 (5) , 1258-1267
Synchronous Fluorescence Spectroscopy for Rapid Classification of Fruit Spirits
- 1 September 2014
- Published by Elsevier in Food Chemistry
- Vol. 159, 282-286
Simultaneous determination of caffeine, caramel and riboflavin in cola-type and energy drinks by synchronous fluorescence technique coupled with partial least squares
- 1 September 2014
- Published by Elsevier in Food Chemistry
- Vol. 159, 282-286
Simultaneous determination of caffeine, caramel and riboflavin in cola-type and energy drinks by synchronous fluorescence technique coupled with partial least squares