Dolly B. Tyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dolly B. Tyan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Chia-Jung Chang
Stanford Genome Technology Center, 3165 Porter Drive, Palo Alto, CA 94304, USA
2 shared publicationsFumiko Yamamoto
Histocompatibility, Immunogenetics & Disease Profiling Laboratory, Stanford Blood Center, 3373 Hillview Avenue, Palo Alto, CA 94304, USA
2 shared publications- B. Höglund
Roche Molecular Systems (RMS), Pleasanton, CA, USA
1 shared publication Brian D. Bradbury
Clinical Development and Center for Observational Research , Amgen, Inc. , Thousand Oaks , CA , USA
1 shared publicationCalvin D. Lou
Histocompatibility, Immunogenetics, and Disease Profiling Laboratory, Department of Pathology , Stanford University , Palo Alto , CA , USA
1 shared publication- Cherie L. Holcomb
Human Genetics, Roche Molecular Systems, Inc., Pleasanton, CA, USA
1 shared publication
Latest Publications
- 1 April 2020
- Published by Wolters Kluwer Health in Transplantation
- Vol. 104 (4) , 813-822
DSA-FXM: Accelerated Donor-specific Flow Crossmatch Discriminating Class I and II Antibody Specifically and Only to Donor HLA for Determining True Incompatibility
Background.: Worldwide, a final crossmatch is the gold standard for determining compatibility between patient and donor before solid organ transplantation and preventing hyperacute rejection. In the absence of autoantibodies, an incompatible crossmatch in a sensitized patient is attributed to mismatched donor HLA. However, current physical crossmatch methods cannot distinguish reactivity to HLA from other clinically irrelevant cell surface targets nor the class of HLA if it is the target. Result interpretation is difficult or impossible when autoantibodies, alloantibodies, or therapeutic antibodies coexist. Methods.: Herein, we describe a unique donor-specific flow crossmatch (DSA-FXM) that distinguishes HLA class I or II donor-specific antibody bound to HLA antigens on the donor cell surface in their native conformation that is not impacted by rituximab, anti-thymocyte globulin (after absorption), or autoantibodies. It is HLA specific. Results.: We compared the results of single-antigen antibody testing, autoreactive and alloreactive flow cytometry crossmatches (FXM) using traditional FXM and our DSA-FXM method from 94 patients (enriched for auto+/allo+ pairs; n = 64) against 110 donors (338 tests) and show that, in our cohort, positive traditional FXM results are not directed to donor HLA 60.25% of the time and negative traditional FXM results are missing HLA donor-specific antibody 36.2% of the time based on the DSA-FXM. Conclusions.: We demonstrate that the DSA-FXM is able to define categorically distinct and clinically important HLA antibody profiles in half the time required for the standard FXM, potentially shortening cold ischemia time and providing clinicians with unambiguous essential information regarding HLA compatibility when time is critical.
- 1 April 2020
- Published by Wolters Kluwer Health in Transplantation
- Vol. 104 (4) , 813-822
DSA-FXM: Accelerated Donor-specific Flow Crossmatch Discriminating Class I and II Antibody Specifically and Only to Donor HLA for Determining True Incompatibility
Background.: Worldwide, a final crossmatch is the gold standard for determining compatibility between patient and donor before solid organ transplantation and preventing hyperacute rejection. In the absence of autoantibodies, an incompatible crossmatch in a sensitized patient is attributed to mismatched donor HLA. However, current physical crossmatch methods cannot distinguish reactivity to HLA from other clinically irrelevant cell surface targets nor the class of HLA if it is the target. Result interpretation is difficult or impossible when autoantibodies, alloantibodies, or therapeutic antibodies coexist. Methods.: Herein, we describe a unique donor-specific flow crossmatch (DSA-FXM) that distinguishes HLA class I or II donor-specific antibody bound to HLA antigens on the donor cell surface in their native conformation that is not impacted by rituximab, anti-thymocyte globulin (after absorption), or autoantibodies. It is HLA specific. Results.: We compared the results of single-antigen antibody testing, autoreactive and alloreactive flow cytometry crossmatches (FXM) using traditional FXM and our DSA-FXM method from 94 patients (enriched for auto+/allo+ pairs; n = 64) against 110 donors (338 tests) and show that, in our cohort, positive traditional FXM results are not directed to donor HLA 60.25% of the time and negative traditional FXM results are missing HLA donor-specific antibody 36.2% of the time based on the DSA-FXM. Conclusions.: We demonstrate that the DSA-FXM is able to define categorically distinct and clinically important HLA antibody profiles in half the time required for the standard FXM, potentially shortening cold ischemia time and providing clinicians with unambiguous essential information regarding HLA compatibility when time is critical.
- 1 September 2019
- Published by Elsevier in Human Immunology
- Vol. 80 (9) , 668-702
Mapping and definition of HLA class I and II serologic epitopes using an unbiased reverse engineering strategy
- 1 September 2019
- Published by Elsevier in Human Immunology
- Vol. 80 (9) , 668-702
Mapping and definition of HLA class I and II serologic epitopes using an unbiased reverse engineering strategy
- 1 September 2019
- Published by Elsevier in Human Immunology
- Vol. 80 (9) , 661-667
A reverse-engineering strategy utilizing the integration of single antigen beads and NGS HLA genotypes to detect potential antibody inducing epitopes
- 1 September 2019
- Published by Elsevier in Human Immunology
- Vol. 80 (9) , 661-667
A reverse-engineering strategy utilizing the integration of single antigen beads and NGS HLA genotypes to detect potential antibody inducing epitopes
- Open Access
- 1 October 2017
- Published by Wolters Kluwer Health in Current Opinion in Organ Transplantation
- Vol. 22 (5) , 505-510
Application, technical issues, and interpretation of C1q for graft outcome
Significant interest and controversy surround the use of C1q for determining risk of antibody-mediated rejection (AMR) and graft loss. Alternate models for predicting outcomes have been proposed. This review focuses on the correlation of currently utilized assays for outcome, together with the technical and theoretical limitations, to distill current thinking. Results demonstrate that C1q status is significantly correlated with AMR and graft loss. There is general consensus that C1q is more clinically relevant for graft outcome than neat IgG MFI. IgG titers, subclass, and other complement assays have now been studied to determine if they are more relevant. Only IgG3 and possibly C3d fixation have shown added value to C1q for outcome correlation. Direct parallel titer comparisons of C1q and IgG are lacking and the correlation is unknown. Overall, results confirm the correlation with C1q+ donor-specific antibody (DSA) for AMR and graft loss. The association is stronger posttransplant. C1q+ de novo antibody appears to be especially detrimental portending graft loss in about 1–2.5 years post detection. Recommendations to biopsy and treat at time of de novo C1q+ antibody detection have been suggested by several groups.
- 1 October 2017
- Published by Wolters Kluwer Health in Current Opinion in Organ Transplantation
- Vol. 22 (5) , 505-510
Open AccessApplication, technical issues, and interpretation of C1q for graft outcome
Significant interest and controversy surround the use of C1q for determining risk of antibody-mediated rejection (AMR) and graft loss. Alternate models for predicting outcomes have been proposed. This review focuses on the correlation of currently utilized assays for outcome, together with the technical and theoretical limitations, to distill current thinking. Results demonstrate that C1q status is significantly correlated with AMR and graft loss. There is general consensus that C1q is more clinically relevant for graft outcome than neat IgG MFI. IgG titers, subclass, and other complement assays have now been studied to determine if they are more relevant. Only IgG3 and possibly C3d fixation have shown added value to C1q for outcome correlation. Direct parallel titer comparisons of C1q and IgG are lacking and the correlation is unknown. Overall, results confirm the correlation with C1q+ donor-specific antibody (DSA) for AMR and graft loss. The association is stronger posttransplant. C1q+ de novo antibody appears to be especially detrimental portending graft loss in about 1–2.5 years post detection. Recommendations to biopsy and treat at time of de novo C1q+ antibody detection have been suggested by several groups.
- 1 December 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (12) , 910-916
Very high resolution single pass HLA genotyping using amplicon sequencing on the 454 next generation DNA sequencers: Comparison with Sanger sequencing
- 1 December 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (12) , 910-916
Very high resolution single pass HLA genotyping using amplicon sequencing on the 454 next generation DNA sequencers: Comparison with Sanger sequencing
- Open Access
- 5 September 2013
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 28 (11) , 2908-2918
Sensitization from transfusion in patients awaiting primary kidney transplant
Sensitization to human leukocyte antigen (HLA) from red blood cell (RBC) transfusion is poorly quantified and is based on outdated, insensitive methods. The objective was to evaluate the effect of transfusion on the breadth, magnitude and specificity of HLA antibody formation using sensitive and specific methods. Transfusion, demographic and clinical data from the US Renal Data System were obtained for patients on dialysis awaiting primary kidney transplant who had ≥2 HLA antibody measurements using the Luminex single-antigen bead assay. One cohort included patients with a transfusion (n = 50) between two antibody measurements matched with up to four nontransfused patients (n = 155) by age, sex, race and vintage (time on dialysis). A second crossover cohort (n = 25) included patients with multiple antibody measurements before and after transfusion. We studied changes in HLA antibody mean fluorescence intensity (MFI) and calculated panel reactive antibody (cPRA). In the matched cohort, 10 of 50 (20%) transfused versus 6 of 155 (4%) nontransfused patients had a ≥10 HLA antibodies increase of >3000 MFI (P = 0.0006); 6 of 50 (12%) transfused patients had a ≥30 antibodies increase (P = 0.0007). In the crossover cohort, the number of HLA antibodies increasing >1000 and >3000 MFI was higher in the transfused versus the control period, P = 0.03 and P = 0.008, respectively. Using a ≥3000 MFI threshold, cPRA significantly increased in both matched (P = 0.01) and crossover (P = 0.002) transfused patients. Among prospective primary kidney transplant recipients, RBC transfusion results in clinically significant increases in HLA antibody strength and breadth, which adversely affect the opportunity for future transplant.
- 5 September 2013
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 28 (11) , 2908-2918
Open AccessSensitization from transfusion in patients awaiting primary kidney transplant
Sensitization to human leukocyte antigen (HLA) from red blood cell (RBC) transfusion is poorly quantified and is based on outdated, insensitive methods. The objective was to evaluate the effect of transfusion on the breadth, magnitude and specificity of HLA antibody formation using sensitive and specific methods. Transfusion, demographic and clinical data from the US Renal Data System were obtained for patients on dialysis awaiting primary kidney transplant who had ≥2 HLA antibody measurements using the Luminex single-antigen bead assay. One cohort included patients with a transfusion (n = 50) between two antibody measurements matched with up to four nontransfused patients (n = 155) by age, sex, race and vintage (time on dialysis). A second crossover cohort (n = 25) included patients with multiple antibody measurements before and after transfusion. We studied changes in HLA antibody mean fluorescence intensity (MFI) and calculated panel reactive antibody (cPRA). In the matched cohort, 10 of 50 (20%) transfused versus 6 of 155 (4%) nontransfused patients had a ≥10 HLA antibodies increase of >3000 MFI (P = 0.0006); 6 of 50 (12%) transfused patients had a ≥30 antibodies increase (P = 0.0007). In the crossover cohort, the number of HLA antibodies increasing >1000 and >3000 MFI was higher in the transfused versus the control period, P = 0.03 and P = 0.008, respectively. Using a ≥3000 MFI threshold, cPRA significantly increased in both matched (P = 0.01) and crossover (P = 0.002) transfused patients. Among prospective primary kidney transplant recipients, RBC transfusion results in clinically significant increases in HLA antibody strength and breadth, which adversely affect the opportunity for future transplant.