GMGregory S. Makowski

Gregory S. Makowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gregory S. Makowski has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An indium:calcium phosphate colloid that specifically targets fibrin

    by Gregory S. Makowski, Melinda L. Ramsby, Gale R. Ramsby

    The ability of indium to target fibrin in vitro was evaluated. The radionuclide 114mIndium (114mIn) was prepared as a soluble and colloidal (In:In) form, as well as, a mixed indium:calcium phosphate (In:CaP) colloid. Soluble 114mIn was prepared by maintaining acid pH (50 mM HCl). Colloidal 114mIn (In:In) was prepared under slightly basic conditions (50 mM Tris-Cl, pH 7.6). The mixed In:CaP colloid was prepared by incubation of 114mIn with calcium (10 mM) and phosphate (250 μM) under slightly basic conditions (50 mM Tris-Cl, pH 7.6). To assess fibrin binding, the three 114mIn preparations were mixed with diluted human plasma (source of fibrinogen). Fibrin polymerization was initiated by addition of calcium (5 mM) and thrombin (0.5 U/ml). Following incubation (15 min, 37 °C), the fibrin matrix was condensed, removed from the reaction mixture, and washed briefly. Fibrin uptake of 114mIn (soluble, colloidal, or In:CaP) was determined by gamma counting. Results demonstrated that soluble 114mIn exclusively bound a plasma protein electrophoretically and immunologically identified as transferrin. Although both colloidal 114mIn and 114mIn:CaP bound fibrin, the mixed 114mIn:CaP colloid demonstrated substantially higher fibrin binding activity (about 2-fold). The target of indium binding was confirmed as fibrin due to the presence of characteristic cross-linked γ–γ dimers (100 kDa) and β-monomers (58 kDa) by SDS-PAGE. 114mIn colloid and the mixed 114mIn:CaP colloid demonstrated no ability to bind fibrin’s precursor, fibrinogen. 114mIn:CaP fibrin binding was associated with formation of CaP, as evidenced by its dependence on phosphate concentration. The biocompatibility of CaP including its ability to bind 114mIn and specifically target fibrin may be of potential value for diagnostic imaging studies to identify regions of occult vascular stenosis (i.e., atherosclerotic plaques, deep vein thrombosis, pulmonary embolus).


  • Gelatinolytic and fibrinolytic activity in fresh-frozen plasma

    by Gregory S. Makowski, Melinda L. Ramsby

    Fresh-frozen plasma (FFP) was evaluated for gelatinolytic and fibrinolytic activity. Gelatin zymography revealed that gelatinase A (MMP-2) was constitutively present in FFP whereas gelatinase B (MMP-9) was present at variable levels. The presence of MMP-9 likely represents differential release from neutrophils during FFP collection or processing. Although fibrin matrices generated from FFP or freshly prepared plasma contained characteristic crosslinked γ-γ dimers and β-monomers, matrices generated from FFP were resistant to spontaneous plasmin-dependent fibrinolysis. This observation likely stems from the plasminogen activator instability and could potentially lead to a hypofibrinolytic state. The impact of these in vitro findings to protease balance in patients receiving multiple FFP doses remains to be determined.


  • Differential effect of calcium phosphate and calcium pyrophosphate on binding of matrix metalloproteinases to fibrin: comparison to a fibrin-binding protease from inflammatory joint fluids

    by G. S. Makowski, M. L. Ramsby

    SUMMARY: The ability of calcium phosphate (CaP) and calcium pyrophosphate (CaPPi) to mediate matrix metalloproteinase-2 and -9 (MMP-2 and MMP-9) binding to fibrin was evaluated. Substrate gel electrophoresis (gelatin zymography) revealed that CaP bound MMP-2 and MMP-9, forming a high molecular weight aggregate with lowered electrophoretic mobility. Formation of the CaP : MMP aggregate was necessary for fibrin binding. In contrast, CaPPi did not aggregate MMPs and did not promote uptake of MMPs into fibrin. Scatchard analysis (Ca/P ratio) revealed that CaPPi (1·96) was chemically similar to calcium pyrophosphate dihydrate (2·00) compared to amorphous CaP (1·50) or crystalline CaP, hydroxyapatite (1·66). MMP : CaP interaction appeared to be electrostatic in nature as high salt concentration (NaCl > 150 mm) reduced binding. In contrast, two non-ionic detergents (Brij-35 and Tween-20) did not prevent MMP : CaP binding. MMP : CaP interaction did not involve the C-terminal MMP region because the specific tissue inhibitor of metalloproteinases (TIMPs) also did not block MMP : CaP interaction and fibrin binding. Although MMP : CaP binding could be decreased with albumin, this effect appeared non-specific due to the high albumin concentration required. High albumin concentration could also partially dissociate preformed MMP : CaP complexes. Interestingly, type I and type IV collagen substantially increased MMP : fibrin-binding activity, whereas denatured collagen, gelatin, did not. Inflammatory joint fluid from five patients also demonstrated similar MMP fibrin-binding activity consistent with CaP mediation. The relevance of these findings to CaP and CaPPi in the pathogenesis of crystal arthropathies such as basic calcium phosphate (BCP) and calcium pyrophosphate dihydrate crystal disease (CPPD) is discussed.


  • Open Access

    Concentrations of circulating matrix metalloproteinase 9 inversely correlate with autoimmune antibodies to double stranded DNA: implications for monitoring disease activity in systemic lupus erythematosus

    by G S Makowski, M L Ramsby

    Aims: To compare circulating matrix metalloproteinase (MMP) concentrations with antibodies to single and double stranded DNA (ssDNA and dsDNA) to determine their relation in inflammatory arthritic diseases, such as systemic lupus erythematosus (SLE). Methods: Fibroblast MMP-2 and neutrophil MMP-9 were resolved by gelatin zymography and measured by densitometry. Anti-ssDNA and anti-dsDNA were determined by enzyme immunoassay and samples grouped on antibody content as follows: low anti-ssDNA/low anti-dsDNA antibodies (group 1); high anti-ssDNA/low anti-dsDNA antibodies (group 2); and high anti-ssDNA/high anti-dsDNA antibodies (group 3). Results: Group 3 samples contained significantly lower amounts of MMP-9 when compared with group 1 samples. Higher molecular weight MMP-9 forms (130 and 225 kDa) were virtually absent. Group 2 samples contained intermediate MMP-9 concentrations. Fibroblast MMP-2 was unchanged in all groups. Mean complement C3 and C4 concentrations showed a consistent, but variably significant, decrease with increasing anti-ssDNA and anti-dsDNA antibodies. The mean erythrocyte sedimentation rate was raised in all patient groups. Conclusions: Neutrophil MMP-9, an inflammatory marker, inversely correlates with anti-dsDNA antibodies, which are a specific marker for SLE, and may be important in monitoring disease activity during antibody deposition in tissues.


    • 1 January 2003
      • Vol. 33  (2) , 142-8

    Selective detection of autoimmune antibodies to single- and double-stranded DNA by enzyme immunoassay.

    by Gregory S Makowski, Melinda L Ramsby

    Presence in serum of anti-double-stranded deoxyribonucleic acid antibodies (anti-dsDNA) is one of the diagnostic criteria for systemic lupus erythematosus. Anti-single stranded DNA antibodies (anti-ssDNA) also occur, but their clinical significance is unclear. Use of enzyme immunoassay (EIA) kits that are specific for anti-dsDNA is desirable but problematic, since preparation of dsDNA of high integrity is difficult (ie, regions of ssDNA may persist). This study evaluated an EIA kit that uses low Mw plasmid/bacteriophage DNA as a nucleic acid source. Anti-dsDNA results were compared to results obtained by an anti-ssDNA EIA and an immunofluorescent assay (IFA) that uses Crithidia luciliae (specific for anti-dsDNA). Consecutive serum samples (n=139, 88% female) submitted to the clinical laboratory for anti-dsDNA analysis were evaluated. EIA precision was determined at three levels. Intra-assay precision [mean +/- SD (CV)] for anti-dsDNA: 36 +/- 3.5 IU/ml (9.8%); 98 +/- 4.4 (4.5%); and 245 +/- 5.8 (2.4%); and anti-ssDNA. 40 +/- 1.4 U/ml (3.5%); 190 +/- 4.8 (2.5%); and 283 +/- 10.3 (3.7%) (n=8). Inter-assay precision for anti-dsDNA: 36 +/- 6.3 IU/ml (17.5%); 90 +/- 5.9 (6.6%); and 207 +/- 20.9 (10.1%); and anti-ssDNA: 48 +/- 8.2 U/ml (17.0%); 193 +/- 12.7 (6.6%); and 263 +/- 21.5 (8.2%) (n=8). Linearity was assessed with (a) high dsDNA/high ssDNA and (b) low dsDNA/high ssDNA samples (no high dsDNA/low ssDNA samples were identified). Linearity (>200 IU/ml) was found for both sample types with a correlation coefficient (r) of 0.995-0.999. Anti-dsDNA immunoreactivity was not apparent with the low dsDNA/high ssDNA sample. More patients were positive for anti-ssDNA (54%), compared to anti-dsDNA (17%). IFA confirmation (Crithidia) indicated a relative sensitivity and specificity of 94.1% and 93.4% for the anti-dsDNA EIA. IFA positivity correlated with increased anti-dsDNA level: 20% (30-60 IU/ml); 70% (61-200 IU/ml); and 89% (>200 IU/ml). Of specimens that were anti-ssDNA positive and anti-dsDNA negative (n=51), only one was IFA positive. When IFA was compared to an anti-dsDNA EIA kit that used high Mw calf thymus DNA, lower relative specificity (88.2%) and sensitivity (72.6%) was obtained. Anti-ssDNA was found in many false positive specimens (87%).


    • 1 January 2003
      • Vol. 33  (3) , 243-50

    Single tube multiplex PCR detection of 27 cystic fibrosis mutations and 4 polymorphisms using neonatal blood samples collected on Guthrie cards.

    by Gregory S Makowski, Francesca L Nadeau, Sidney M Hopfer

    In response to recommendations for cystic fibrosis (CF) carrier screening of the American College of Medical Genetics/American College of Obstetrics and Gynecology (ACMG/ACOG), we evaluated a commercial kit for mutation panel testing (Roche CF Gold Linear Array Panel). This kit tests for 25 CF mutations and 4 polymorphisms; it comprises an analyte specific reagent for single tube multiplex polymerase chain reaction (PCR) amplification and subsequent allele specific oligonucleotide (ASO) hybridization. Neonatal whole blood samples collected on Guthrie card filter paper served as the DNA source. Following a wash step to remove whole blood PCR inhibitors, multiplex PCR amplification could be performed either on DNA that was heat extracted from Guthrie cards or directly on the filter paper matrix itself. In 13 CF patient samples, the CF mutation results obtained with this kit agreed completely with those obtained from a reference laboratory that performs an 87 CF mutation panel. The kit was reliable, despite the small sample size (3 mm diameter punch of the Guthrie card), the presence of PCR inhibitors in whole blood, and protracted storage of blood samples (up to 9 yr at room temperature). The kit was convenient, cost competitive, and practical for use in a small CF screening laboratory.


  • Open Access

    Changes in Academic Productivity: Implications for Clinical Laboratory Research and Development

    by Gregory S Makowski, Sidney M Hopfer, Gregory J Tsongalis, Alan H B Wu

    A recent report from the Council of Scientific Affairs of the American Medical Association indicated that the introduction of managed healthcare had a substantially negative influence on the academic productivity of clinical faculty in academic health centers (1). Consistent with this finding is the observed change in the number of scientific abstracts presented during the Annual Meeting of the AACC (2). As can be seen, over the last 4 years there has been a substantial 30% decrease in the number of abstracts received and accepted from all sources, including academia and industry (Fig. 1 , A and B). This decline does not correlate to a change in the abstract rejection rate, which has remained relatively constant (∼20%) since 1992 (Fig. 1C ).