Jeffrey J. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeffrey J. Brown has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Charles F. Hildebolt
Department of Body MRI, Mallinckrodt Institute of Radiology and Washington University in St. Louis, Washington University Medical Center, 510 S Kingshighway Blvd., St. Louis, MO 63110-1076
2 shared publicationsArthur E. Stillman
Department of Radiology, University of Minnesota Hospital, Minneapolis, Minnesota 55455
1 shared publicationBasil A. Molony
Oncomembrane, Inc., Seattle, Washington 98101
1 shared publicationCharles F Hildebolt
1 shared publicationElizabeth G McFarland
Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Boulevard, St. Louis, MO 63110, USA
1 shared publicationFadi El-Merhi
Department of Body MRI, Mallinckrodt Institute of Radiology and Washington University in St. Louis, Washington University Medical Center, 510 S Kingshighway Blvd., St. Louis, MO 63110-1076
1 shared publication
Latest Publications
- 1 April 2009
- Vol. 92 (4) , 548-55
Serial MR imaging of small arterially-enhancing liver lesions in patients with chronic liver disease.
To determine the significance of small arterially-enhancing liver lesions seen with magnetic resonance imaging (MRI) in patients with chronic liver disease. Our institutional review board approved this retrospective study, without requiring informed consent. Over a two-year period, 258 consecutive patients with cirrhosis or chronic hepatitis underwent multiphase three-dimensional, gadolinium-enhanced, breath-hold gradient-echo MRI. From this group, 29 patients underwent at least one follow-up MR study. When a small (< or = 20 mm) arterially-enhancing lesion was detected, the maximum diameter shape, signal intensities (T1-weighted and T2-weighted), and pattern of enhancement were evaluated to assess the associations between the imaging appearance on initial MR exam and subsequent behavior on follow-up imaging. Statistical testing was performed with JMP Statistical Software (SAS, Inc., Cary, NC) and StatXact 7 Statistical Software for Exact Nonparmetric Inference (Cytel, Inc., Cambride, MA). Sixty-five small (< or = 20 mm) arterially-enhancing lesions were detected in 29 patients. Ten of 65 lesions (15%) in nine patients were subsequently proven to represent hepatocellular carcinoma (HCC), while the remaining lesions either disappeared (46) or remained stable in size (9). Of the 10 lesions subsequently proven to represent HCC, eight lesions converted from hypo- or isointense to hyperintense on subsequent T2-weighted MRI (p < 0.001), seven lesions converted from hyper- or isointense to hypointense on subsequent T1-weighted images (p < 0.001), seven lesions demonstrated growth on subsequent MRI exam (mean increase in mean diameter = 1.4 cm), and five lesions subsequently developed rim enhancement that was not initially present. Small, arterially-enhancing lesions detected with MRI have a low likelihood of representing HCC, and MRI follow-up of such lesions is a reasonable approach. Lesions that increase in size, convert to hypointense on subsequent T1W images, convert to hyperintense in T2W images, or develop rim enhancement on follow-up MRI images are concerning and should prompt consideration of intervention.
- 1 April 2009
- Vol. 92 (4) , 548-55
Serial MR imaging of small arterially-enhancing liver lesions in patients with chronic liver disease.
To determine the significance of small arterially-enhancing liver lesions seen with magnetic resonance imaging (MRI) in patients with chronic liver disease. Our institutional review board approved this retrospective study, without requiring informed consent. Over a two-year period, 258 consecutive patients with cirrhosis or chronic hepatitis underwent multiphase three-dimensional, gadolinium-enhanced, breath-hold gradient-echo MRI. From this group, 29 patients underwent at least one follow-up MR study. When a small (< or = 20 mm) arterially-enhancing lesion was detected, the maximum diameter shape, signal intensities (T1-weighted and T2-weighted), and pattern of enhancement were evaluated to assess the associations between the imaging appearance on initial MR exam and subsequent behavior on follow-up imaging. Statistical testing was performed with JMP Statistical Software (SAS, Inc., Cary, NC) and StatXact 7 Statistical Software for Exact Nonparmetric Inference (Cytel, Inc., Cambride, MA). Sixty-five small (< or = 20 mm) arterially-enhancing lesions were detected in 29 patients. Ten of 65 lesions (15%) in nine patients were subsequently proven to represent hepatocellular carcinoma (HCC), while the remaining lesions either disappeared (46) or remained stable in size (9). Of the 10 lesions subsequently proven to represent HCC, eight lesions converted from hypo- or isointense to hyperintense on subsequent T2-weighted MRI (p < 0.001), seven lesions converted from hyper- or isointense to hypointense on subsequent T1-weighted images (p < 0.001), seven lesions demonstrated growth on subsequent MRI exam (mean increase in mean diameter = 1.4 cm), and five lesions subsequently developed rim enhancement that was not initially present. Small, arterially-enhancing lesions detected with MRI have a low likelihood of representing HCC, and MRI follow-up of such lesions is a reasonable approach. Lesions that increase in size, convert to hypointense on subsequent T1W images, convert to hyperintense in T2W images, or develop rim enhancement on follow-up MRI images are concerning and should prompt consideration of intervention.
- 1 June 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (6) , 1746-1753
Hybrid Peripheral 3D Contrast-Enhanced MR Angiography of Calf and Foot Vasculature
OBJECTIVE. The objective of our study was to describe hybrid peripheral (HyPer) 3D contrast-enhanced MR angiography (CE-MRA) using sagittal acquisition with parallel imaging of the calf and foot station. The benefit of a dedicated sagittal 3D CE-MRA acquisition of the calf and foot was evaluated by assessing the degree of venous contamination and its diagnostic quality compared with standard bolus chase 3D CE-MRA alone. MATERIALS AND METHODS. Fifty-three patients (99 legs) were scanned with a 1.5-T MR system equipped with a dedicated bilateral lower extremity phased-array coil. First, high-resolution 3D CE-MRA images of the calves and feet were obtained using two separate sagittal slabs with parallel imaging, with a resulting voxel size of 1.4 × 1.0 × 1.0 mm3. Second, standard bolus chase 3D CE-MRA was performed from the abdomen and pelvis station to the calf-foot station. Images were interpreted by two radiologists. The calf-foot arterial trees were divided into 12 segments. Each segment was characterized as diagnostic or nondiagnostic. The degree of venous contamination was assessed as interfering with the diagnosis or not. Paired Student's t test and Wilcoxon's signed rank test were used to test for statistically significant differences between the techniques. RESULTS. For the left leg (n = 48), the mean number (± SD) of diagnosed arterial segments for HyPer 3D CE-MRA was 9.2 ± 2.3 and for bolus chase 3D CE-MRA, 7.1 ± 4.2 (p ≤ 0.0004). For the right leg (n = 51), the corresponding values were 9.4 ± 2.2 and 7.6 ± 3.5 (p ≤ 0.0005), respectively. For bolus chase 3D CE-MRA, venous contamination interfered with the diagnosis in 24 of 99 legs, whereas with HyPer 3D CE-MRA, there was no interference. Selective analysis of the dorsalis pedis arteries showed that the number of diagnostic vessels was 62 (62.6%) of 99 for HyPer 3D CE-MRA and 13 (13.1%) of 99 for bolus chase 3D CE-MRA. CONCLUSION. HyPer 3D CE-MRA is an alternative method for time-resolved high-resolution peripheral CE-MRA in evaluating the trifurcation and feet vessels with no venous contamination.
- 1 June 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (6) , 1746-1753
Hybrid Peripheral 3D Contrast-Enhanced MR Angiography of Calf and Foot Vasculature
OBJECTIVE. The objective of our study was to describe hybrid peripheral (HyPer) 3D contrast-enhanced MR angiography (CE-MRA) using sagittal acquisition with parallel imaging of the calf and foot station. The benefit of a dedicated sagittal 3D CE-MRA acquisition of the calf and foot was evaluated by assessing the degree of venous contamination and its diagnostic quality compared with standard bolus chase 3D CE-MRA alone. MATERIALS AND METHODS. Fifty-three patients (99 legs) were scanned with a 1.5-T MR system equipped with a dedicated bilateral lower extremity phased-array coil. First, high-resolution 3D CE-MRA images of the calves and feet were obtained using two separate sagittal slabs with parallel imaging, with a resulting voxel size of 1.4 × 1.0 × 1.0 mm3. Second, standard bolus chase 3D CE-MRA was performed from the abdomen and pelvis station to the calf-foot station. Images were interpreted by two radiologists. The calf-foot arterial trees were divided into 12 segments. Each segment was characterized as diagnostic or nondiagnostic. The degree of venous contamination was assessed as interfering with the diagnosis or not. Paired Student's t test and Wilcoxon's signed rank test were used to test for statistically significant differences between the techniques. RESULTS. For the left leg (n = 48), the mean number (± SD) of diagnosed arterial segments for HyPer 3D CE-MRA was 9.2 ± 2.3 and for bolus chase 3D CE-MRA, 7.1 ± 4.2 (p ≤ 0.0004). For the right leg (n = 51), the corresponding values were 9.4 ± 2.2 and 7.6 ± 3.5 (p ≤ 0.0005), respectively. For bolus chase 3D CE-MRA, venous contamination interfered with the diagnosis in 24 of 99 legs, whereas with HyPer 3D CE-MRA, there was no interference. Selective analysis of the dorsalis pedis arteries showed that the number of diagnostic vessels was 62 (62.6%) of 99 for HyPer 3D CE-MRA and 13 (13.1%) of 99 for bolus chase 3D CE-MRA. CONCLUSION. HyPer 3D CE-MRA is an alternative method for time-resolved high-resolution peripheral CE-MRA in evaluating the trifurcation and feet vessels with no venous contamination.
- 27 March 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (4) , 446-455
The OptiMARK clinical development program: Summary of safety data
Purpose To describe and summarize the safety data from the OptiMARK clinical development program. Materials and Methods In the 18 clinical studies comprising the clinical program, doses ranging from 0.1 to 0.7 mmol/kg were administered to healthy adult volunteers, patients with hepatic or renal impairment, and patients with confirmed or highly suspected central nervous system (CNS), liver, breast, vascular, bone, or soft tissue pathologies. A total of 2038 injections of OptiMARK, Magnevist, or placebo were administered to 1684 subjects. Safety assessments were performed at appropriate intervals during all Phase 1, 2, and 3 studies. Results Of the 1684 subjects exposed to a study drug or placebo in the clinical development program, 646 subjects experienced 1293 adverse events. Thirty‐one percent of the OptiMARK injections were associated with an adverse event. In comparison, 35% of Magnevist injections and 48% of placebo injections were associated with at least one adverse event. Conclusions OptiMARK was safe and well‐tolerated with a safety profile similar to that of Magnevist. J. Magn. Reson. Imaging 2002;15:446–455.
- 27 March 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (4) , 446-455
The OptiMARK clinical development program: Summary of safety data
Purpose To describe and summarize the safety data from the OptiMARK clinical development program. Materials and Methods In the 18 clinical studies comprising the clinical program, doses ranging from 0.1 to 0.7 mmol/kg were administered to healthy adult volunteers, patients with hepatic or renal impairment, and patients with confirmed or highly suspected central nervous system (CNS), liver, breast, vascular, bone, or soft tissue pathologies. A total of 2038 injections of OptiMARK, Magnevist, or placebo were administered to 1684 subjects. Safety assessments were performed at appropriate intervals during all Phase 1, 2, and 3 studies. Results Of the 1684 subjects exposed to a study drug or placebo in the clinical development program, 646 subjects experienced 1293 adverse events. Thirty‐one percent of the OptiMARK injections were associated with an adverse event. In comparison, 35% of Magnevist injections and 48% of placebo injections were associated with at least one adverse event. Conclusions OptiMARK was safe and well‐tolerated with a safety profile similar to that of Magnevist. J. Magn. Reson. Imaging 2002;15:446–455.
- 19 October 2000
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 12 (5) , 702-707
The clinical value of ferric ammonium citrate: A positive oral contrast agent for T1-weighted MR imaging of the upper abdomen
- 19 October 2000
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 12 (5) , 702-707
The clinical value of ferric ammonium citrate: A positive oral contrast agent for T1-weighted MR imaging of the upper abdomen
- 1 June 2000
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 18 (5) , 543-551
A prospective assessment of breath-hold fast spin echo and inversion recovery fast spin echo techniques for detection and characterization of focal hepatic lesions
- 1 June 2000
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 18 (5) , 543-551
A prospective assessment of breath-hold fast spin echo and inversion recovery fast spin echo techniques for detection and characterization of focal hepatic lesions
- 1 February 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (2) , 321-324
Public Policy: The Case for Lobbying in Radiology
- 1 February 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (2) , 321-324
Public Policy: The Case for Lobbying in Radiology