ESEigil Samset

Eigil Samset

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eigil Samset has a total of 183 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Introducing Anatomical Constraints in Mitral Annulus Segmentation in Transesophageal Echocardiography

    by Børge Solli Andreassen, Sarina Thomas, Anne H. Schistad Solberg, Eigil Samset, David Völgyes


  • Automatic alignment of standard views for transesophageal echocardiographic images

    by Håkon Strand Bølviken, Olivier Gerard, Federico Veronesi, Eigil Samset

    Purpose3D transesophageal echocardiography (TEE) has become an important modality for pre- and peri-operative imaging of valvular heart disease. TEE can give excellent visualization of valve morphology in 3D rendering. As a convention, 3D TEE images are reformatted in three standard views. We describe a method for automatic calculation of parameters needed to define the standard views from 3D TEE images using no manual input.ApproachAn algorithm was designed to find the center of the mitral valve and the left ventricular outflow tract (OT). These parameters defined the three-chamber view. The problem was modeled as a state estimation problem in which a 3D model was deformed based on shape priors and edge detection using a Kalman filter. This algorithm is capable of running in real time after initialization.ResultsThe algorithm was validated by comparing the automatic alignments of 106 TEE images against manually placed landmarks. The median error for determining the mitral valve center was 7.1 mm, and the median error for determining the left ventricular OT orientation was 13.5 deg.ConclusionThe algorithm is an accurate tool for automating the process of finding standard views for TEE images of the mitral valve.

  • Open Access

    Mitral Annulus Segmentation and Anatomical Orientation Detection in TEE Images Using Periodic 3D CNN

    by Borge Solli Andreassen, David Volgyes, Eigil Samset, Anne H. Schistad Solberg

    Segmentation of the mitral annulus is often an important step in cardiac examinations. We propose a robust 3D method for predicting the anatomical orientation and segmentation of the mitral annulus in 3D transesophageal echocardiography. The method takes advantage of the circular anatomy of the annulus by utilizing cylinder coordinate samples and a 3D convolutional neural network with circular convolutions. Furthermore, the paper proposes new landmark detection loss functions based on the earth mover’s distance. The method’s effectiveness was demonstrated by training a HighRes3dNet model and evaluating its performance on a separate test set consisting of 135 frames from 19 examinations. The obtained coordinate prediction error was 1.96±1.62 mm, and the anatomical orientation prediction error was 9.7°±15.8°. The robust and fully automatic mitral annulus segmentation and orientation prediction provided by the method can ease the workload of clinicians and provide time savings in clinics.


  • User-Intended Doppler Measurement Type Prediction Combining CNNs With Smart Post-Processing

    by Andrew Gilbert, Marit Holden, Line Eikvil, Mariia Rakhmail, Aleksandar Babic, Svein Arne Aase, Eigil Samset, Kristin McLeod

    Spectral Doppler measurements are an important part of the standard echocardiographic examination. These measurements give insight into myocardial motion and blood flow providing clinicians with parameters for diagnostic decision making. Many of these measurements are performed automatically with high accuracy, increasing the efficiency of the diagnostic pipeline. However, full automation is not yet available because the user must manually select which measurement should be performed on each image. In this work, we develop a pipeline based on convolutional neural networks (CNNs) to automatically classify the measurement type from cardiac Doppler scans. We show how the multi-modal information in each spectral Doppler recording can be combined using a meta parameter post-processing mapping scheme and heatmaps to encode coordinate locations. Additionally, we experiment with several architectures to examine the tradeoff between accuracy, speed, and memory usage for resource-constrained environments. Finally, we propose a confidence metric using the values in the last fully connected layer of the network and show that our confidence metric can prevent many misclassifications. Our algorithm enables a fully automatic pipeline from acquisition to Doppler spectrum measurements. We achieve 96% accuracy on a test set drawn from separate clinical sites, indicating that the proposed method is suitable for clinical adoption.


  • Open Access

    Generating Synthetic Labeled Data From Existing Anatomical Models: An Example With Echocardiography Segmentation

    by Andrew Gilbert, Maciej Marciniak, Cristobal Rodero, Pablo Lamata, Eigil Samset, Kristin Mcleod

    Deep learning can bring time savings and increased reproducibility to medical image analysis. However, acquiring training data is challenging due to the time-intensive nature of labeling and high inter-observer variability in annotations. Rather than labeling images, in this work we propose an alternative pipeline where images are generated from existing high-quality annotations using generative adversarial networks (GANs). Annotations are derived automatically from previously built anatomical models and are transformed into realistic synthetic ultrasound images with paired labels using a CycleGAN. We demonstrate the pipeline by generating synthetic 2D echocardiography images to compare with existing deep learning ultrasound segmentation datasets. A convolutional neural network is trained to segment the left ventricle and left atrium using only synthetic images. Networks trained with synthetic images were extensively tested on four different unseen datasets of real images with median Dice scores of 91, 90, 88, and 87 for left ventricle segmentation. These results match or are better than inter-observer results measured on real ultrasound datasets and are comparable to a network trained on a separate set of real images. Results demonstrate the images produced can effectively be used in place of real data for training. The proposed pipeline opens the door for automatic generation of training data for many tasks in medical imaging as the same process can be applied to other segmentation or landmark detection tasks in any modality. The source code and anatomical models are available to other researchers. 1 1https://adgilbert.github.io/data-generation/


  • Two methods for modifed Doo–Sabin modeling of nonsmooth surfaces—applied to right ventricle modeling

    by Håkon Strand Bølviken, Jørn Bersvendsen, Fredrik Orderud, Sten Roar Snare, Pål Brekke, Eigil Samset

    Purpose: In recent years, there has been increased clinical interest in the right ventricle (RV) of the heart. RV dysfunction is an important prognostic marker for several cardiac diseases. Accurate modeling of the RV shape is important for estimating the performance. We have created computationally effective models that allow for accurate estimation of the RV shape. Approach: Previous approaches to cardiac shape modeling, including modeling the RV geometry, has used Doo–Sabin surfaces. Doo–Sabin surfaces allow effective computation and adapt to smooth, organic surfaces. However, they struggle with modeling sharp corners or ridges without many control nodes. We modified the Doo–Sabin surface to allow for sharpness using weighting of vertices and edges instead. This was done in two different ways. For validation, we compared the standard Doo–Sabin versus the sharp Doo–Sabin models in modeling the RV shape of 16 cardiac ultrasound images, against a ground truth manually drawn by a cardiologist. A Kalman filter fitted the models to the ultrasound images, and the difference between the volume of the model and the ground truth was measured. Results: The two modified Doo–Sabin models both outperformed the standard Doo–Sabin model in modeling the RV. On average, the regular Doo–Sabin had an 8-ml error in volume, whereas the sharp models had 7- and 6-ml error, respectively. Conclusions: Compared with the standard Doo–Sabin, the modified Doo–Sabin models can adapt to a larger variety of surfaces while still being compact models. They were more accurate on modeling the RV shape and could have uses elsewhere.


  • Mitral Annulus Segmentation Using Deep Learning in 3-D Transesophageal Echocardiography

    by Borge Solli Andreassen, Federico Veronesi, Olivier Gerard, Anne H. Schistad Solberg, Eigil Samset

    3D Transesophageal Echocardiography is an excellent tool for evaluating the mitral valve and is also well suited for guiding cardiac interventions. We introduce a fully automatic method for mitral annulus segmentation in 3D Transesophageal Echocardiography, which requires no manual input. One hundred eleven multi-frame 3D transesophageal echocardiography recordings were split into training, validation, and test sets. Each 3D recording was decomposed into a set of 2D planes, exploiting the symmetry around the centerline of the left ventricle. A deep 2D convolutional neural network was trained to predict the mitral annulus coordinates, and the predictions from neighboring planes were regularized by enforcing continuity around the annulus. Applying the final model and postprocessing to the test set data gave a mean error of 2.0 mm - with a standard deviation of 1.9 mm. Fully automatic segmentation of the mitral annulus can alleviate the need for manual interaction in the quantification of an array of mitral annular parameters and has the potential to eliminate inter-observer variability.


  • Value of Myocardial Work Estimation in the Prediction of Response to Cardiac Resynchronization Therapy

    by Elena Galli, Christophe Leclercq, Maxime Fournet, Arnaud Hubert, Anne Bernard, Otto A. Smiseth, Philippe Mabo, Eigil Samset, Alfredo Hernandez, Erwan Donal


  • Volumetric imaging of fast mechanical waves in the heart using a clinical ultrasound system

    by Pedro Santos, Lasse Lovstakken, Eigil Samset, Jan D'Hooge, Lasse L⊘Vstakken

    The detection and quantification of fast myocardial waves, such as the ones following mechanical activation and aortic valve closure (AVC), may reveal important clinical information about both systolic and diastolic cardiac function. Such waves have previously been observed using multiple high frame rate (HFR) 2-D recordings. However, making multiple 2D recordings lengthens the data acquisition process. Moreover, heart rate variability in combination with the short-lived nature of the studied events makes temporal alignment of these multiple 2D recordings challenging. Fast volumetric imaging would mitigate both problems. However, clinical matrix arrays hinder the straightforward implementation of diverging waves (DW), due to sub-aperture processing (SAP). In this paper, a 3×3 DW sequence implemented on a clinical system using a transesophageal echocardiographic SAP-based matrix array has been validated in-vitro. Subsequently, ultrafast 3D tissue Doppler, strain rate and tissue acceleration were recorded for 4 healthy volunteers at 610 vol/s and used to characterize fast myocardial events. Early myocardial ejection shortening was found in the basal and mid septal wall, as well as in the basal inferior wall. In the septal wall, its propagation was measured as 1.1±0.1 m/s. The wave following AVC was seen traveling both laterally and towards the apex at 4.2±1.0 m/s. These findings seem in agreement with previous reports based on 2D HFR imaging, therefore corroborating the suitability of the 3×3 DW sequence to detect fast myocardial events in 3D within a single heartbeat in a clinical setting.


  • Volumetric imaging of fast mechanical waves in the heart using a clinical ultrasound system: A feasibility study

    by Pedro Santos, Lasse Lovstakken, Eigil Samset, Jan D'Hooge

    Fast mechanical waves following e.g. electromechanical activation and aortic valve closure (AVC) have been imaged using 2D diverging waves (DW). However, their full characterization requires multiple 2D recordings in subsequent heartbeats. Given the heart cycle variability and short-lived nature of these waves, temporal alignment is challenging. Moreover, clinical matrix arrays hinder the straightforward implementation of DW, due to sub-aperture (SAP) beam forming. We have recently proposed a sparse DW sequence capable of imaging a 70°x70° volume in a clinical system and reported its preliminary validation in vivo against 2D Tissue Doppler Imaging (TDI). Herein, the feasibility of measuring fast mechanical events in 3D in vivo was investigated.