N. Reynaert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
N. Reynaert has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
H. Thierens
Department of Biomedical Physics, University of Gent, Proeftuinstraat 86, B‐9000 Gent, Belgium
2 shared publications- Hugo Palmans
National Physical Laboratory
2 shared publications E. Sterpin
1 shared publicationF. Crop
1 shared publicationF. Verhaegen
1 shared publicationM. Van Eijkeren
1 shared publication
Latest Publications
- Open Access
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S112-S113
OC-0226: Towards consistency of TPS dose calculations: converting dose to medium to dose to water
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S112-S113
Open AccessOC-0226: Towards consistency of TPS dose calculations: converting dose to medium to dose to water
- 30 September 2002
- Published by Wiley in Medical Physics
- Vol. 29 (10) , 2446-2454
Parameter dependence of the MCNP electron transport in determining dose distributions
In this paper, a detailed study of the electron transport in MCNP is performed, separating the effects of the energy binning technique on the energy loss rate, the scattering angles, and the sub‐step length as a function of energy. As this problem is already well known, in this paper we focus on the explanation as to why the default mode of MCNP can lead to large deviations. The resolution dependence was investigated as well. An error in the MCNP code in the energy binning technique in the default mode (DBCN 18 was revealed, more specific in the updating of cross sections when a sub‐step is performed corresponding to a high‐energy loss. This updating error is not present in the ITS mode (DBCN 18 and leads to a systematically lower dose deposition rate in the default mode. The effect is present for all energies studied (0.5–10 MeV) and depends on the geometrical resolution of the scoring regions and the energy grid resolution. The effect of the energy binning technique is of the same order of that of the updating error for energies below 2 MeV, and becomes less important for higher energies. For a 1 MeV point source surrounded by homogeneous water, the deviation of the default MCNP results at short distances attains 9% and remains approximately the same for all energies. This effect could be corrected by removing the completion of an energy step each time an electron changes from an energy bin during a sub‐step. Another solution consists of performing all calculations in the ITS mode. Another problem is the resolution dependence, even in the ITS mode. The higher the resolution is chosen (the smaller the scoring regions) the faster the energy is deposited along the electron track. It is proven that this is caused by starting a new energy step when crossing a surface. The resolution effect should be investigated for every specific case when calculating dose distributions around beta sources. The resolution should not be higher than where EFAC is the energy loss per energy step and CSDA a continuous slowing down approximation range. This effect could as well be removed by determining the cross sections for energy loss and multiple scattering at the average energy of an energy step and by sampling the cross sections for each sub‐step. Overall, we conclude that MCNP cannot be used without a caution due to possible errors in the electron transport. When care is taken, it is possible to obtain correct results that are in agreement with other Monte Carlo codes.
- 30 September 2002
- Published by Wiley in Medical Physics
- Vol. 29 (10) , 2446-2454
Parameter dependence of the MCNP electron transport in determining dose distributions
In this paper, a detailed study of the electron transport in MCNP is performed, separating the effects of the energy binning technique on the energy loss rate, the scattering angles, and the sub‐step length as a function of energy. As this problem is already well known, in this paper we focus on the explanation as to why the default mode of MCNP can lead to large deviations. The resolution dependence was investigated as well. An error in the MCNP code in the energy binning technique in the default mode (DBCN 18 was revealed, more specific in the updating of cross sections when a sub‐step is performed corresponding to a high‐energy loss. This updating error is not present in the ITS mode (DBCN 18 and leads to a systematically lower dose deposition rate in the default mode. The effect is present for all energies studied (0.5–10 MeV) and depends on the geometrical resolution of the scoring regions and the energy grid resolution. The effect of the energy binning technique is of the same order of that of the updating error for energies below 2 MeV, and becomes less important for higher energies. For a 1 MeV point source surrounded by homogeneous water, the deviation of the default MCNP results at short distances attains 9% and remains approximately the same for all energies. This effect could be corrected by removing the completion of an energy step each time an electron changes from an energy bin during a sub‐step. Another solution consists of performing all calculations in the ITS mode. Another problem is the resolution dependence, even in the ITS mode. The higher the resolution is chosen (the smaller the scoring regions) the faster the energy is deposited along the electron track. It is proven that this is caused by starting a new energy step when crossing a surface. The resolution effect should be investigated for every specific case when calculating dose distributions around beta sources. The resolution should not be higher than where EFAC is the energy loss per energy step and CSDA a continuous slowing down approximation range. This effect could as well be removed by determining the cross sections for energy loss and multiple scattering at the average energy of an energy step and by sampling the cross sections for each sub‐step. Overall, we conclude that MCNP cannot be used without a caution due to possible errors in the electron transport. When care is taken, it is possible to obtain correct results that are in agreement with other Monte Carlo codes.
- 9 August 1999
- Published by Wiley in Medical Physics
- Vol. 26 (8) , 1484-1491
Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy
3D dose distributions are calculated for a 32P impregnated stent and a 198Au stent for intravascular brachytherapy with the EGS4 Monte Carlo simulation code. The stents were modeled as a combination of eight helicoidal struts. This allowed investigation of the effect of the stent geometry and the electron absorption in the strut material on the dose distributions. Absorbed dose to water was calculated at radial distances ranging from 50 microm to 5 mm from the stent surface. The dose distributions around the stents are compared to the dose distribution around an intravascular brachy-therapy 192Ir source, also calculated with the EGS4 Monte Carlo code. The dose profiles near the struts show hot spots. At 50 microm distance a peak to valley ratio of 3 for 32P and 6 for 198Au in the dose distribution is obtained. For both the isotopes the inhomogeneities decrease with distance and at a radial depth of 350 microm the effect becomes negligible. The calculations showed the importance of the effect of the absorption in the stent material as this leads to a dose decrease to 67% for the 198Au stent and to 77% for 32P near the stent at a distance of 2 mm from the stent axis. It is concluded that from the dosimetric point of view, the 198Au stent is inferior to the 32P stent and the 192Ir source. Application of the 198Au stent in clinical practice requires further investigation of the importance of the adventitia in the restenosis process, and the tolerance dose of the intima.
- 9 August 1999
- Published by Wiley in Medical Physics
- Vol. 26 (8) , 1484-1491
Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy
3D dose distributions are calculated for a 32P impregnated stent and a 198Au stent for intravascular brachytherapy with the EGS4 Monte Carlo simulation code. The stents were modeled as a combination of eight helicoidal struts. This allowed investigation of the effect of the stent geometry and the electron absorption in the strut material on the dose distributions. Absorbed dose to water was calculated at radial distances ranging from 50 microm to 5 mm from the stent surface. The dose distributions around the stents are compared to the dose distribution around an intravascular brachy-therapy 192Ir source, also calculated with the EGS4 Monte Carlo code. The dose profiles near the struts show hot spots. At 50 microm distance a peak to valley ratio of 3 for 32P and 6 for 198Au in the dose distribution is obtained. For both the isotopes the inhomogeneities decrease with distance and at a radial depth of 350 microm the effect becomes negligible. The calculations showed the importance of the effect of the absorption in the stent material as this leads to a dose decrease to 67% for the 198Au stent and to 77% for 32P near the stent at a distance of 2 mm from the stent axis. It is concluded that from the dosimetric point of view, the 198Au stent is inferior to the 32P stent and the 192Ir source. Application of the 198Au stent in clinical practice requires further investigation of the importance of the adventitia in the restenosis process, and the tolerance dose of the intima.