O. Rampado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
O. Rampado has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
R. Ropolo
7 shared publicationsE. Garelli
4 shared publications- Giovanni Gandini
University of Torino
3 shared publications - R. Ropolo
S.C. Fisica Sanitaria, A.O.U. San Giovanni Battista di Torino, Corso Bramante 88, 10126 Torino, Italy
3 shared publications E Garelli
2 shared publicationsP Isoardi
2 shared publications
Latest Publications
- 1 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (1) , 18-24
Radiochromic films for dental CT dosimetry: A feasibility study
- 1 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (1) , 18-24
Radiochromic films for dental CT dosimetry: A feasibility study
- 1 November 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (11) , 3172-3177
Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom
- 1 November 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (11) , 3172-3177
Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom
- 8 December 2009
- Published by Wiley in Medical Physics
- Vol. 37 (1) , 189-196
Computed tomography dose measurements with radiochromic films and a flatbed scanner
Gafchromic® XR‐QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR‐QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x‐ray beam at different angles in the range 0°–180°. A difference of 49% was found between the response with the axis beam parallel to the film surface (90°) and with the axis beam perpendicular (0° and 180°). Integrating over a 360° exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR‐QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at level of 8% were founded. The uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic® XR‐QA films can be used to evaluate the CTDI.
- 8 December 2009
- Published by Wiley in Medical Physics
- Vol. 37 (1) , 189-196
Computed tomography dose measurements with radiochromic films and a flatbed scanner
Gafchromic® XR‐QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR‐QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x‐ray beam at different angles in the range 0°–180°. A difference of 49% was found between the response with the axis beam parallel to the film surface (90°) and with the axis beam perpendicular (0° and 180°). Integrating over a 360° exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR‐QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at level of 8% were founded. The uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic® XR‐QA films can be used to evaluate the CTDI.
- 31 October 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 72 (1) , 181-187
Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom
- 31 October 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 72 (1) , 181-187
Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom
- 25 October 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (8) , 1219-1228
Patient dose evaluation by means of DICOM images for a direct radiography system
The purpose of this work was to evaluate the statistical distribution of patient dose for different examinations by using the data stored in a DICOM image archive of a direct digital radiography system. An automatic procedure to extract dose data and exposure parameters from the image archives was implemented. During a 4.5-month period, 8,292 images were collected. Exposure parameters and the air kerma area product (P KA) stored in the image DICOM header were examined for each image. The entrance surface air kerma (K a,e), a quantity comparable to the current diagnostic reference levels (DRL), was estimated considering the P KA and the geometric parameters of each examination. P KA and K a,e distributions showed highly variable values. The obtained K a,e values were substantially lower than the DRL. DRL were more than six times the mean value of K a,e distribution for the abdomen anteroposterior (AP) and lumbar spine lateral (LAT) projections, whereas the ratio was equal to 2.7 for posteroanterior (PA) chest examinations. The method adopted proved to be effective for characterising the dose of each examination by means of the statistical analysis of the dose quantities over extensive samples. The dose values obtained and the comparison with the DRL showed that this radiographic device allows substantial dose savings compared with estimations made for nondigital or for phosphor-based systems. Lo scopo di questo lavoro è stato quello di utilizzare i dati memorizzati nell’archivio DICOM delle immagini realizzate con un apparecchio digitale diretto per valutare la distribuzione statistica della dose al paziente per diversi esami. È stata implementata una procedura informatica automatizzata di estrazione dei dati di dose e dei parametri di esposizione dall’archivio delle immagini realizzate. La raccolta dei dati è stata effettuata per un periodo di quattro mesi e mezzo e per un totale di 8292 immagini. Per ciascuna immagine sono stati considerati i parametri di esposizione e il prodotto kerma per area (P KA ) memorizzati nel header dei file immagine. Considerando il P KA e i parametri geometrici di ciascun esame è stato possibile effettuare una stima di kerma superficiale in ingresso (K a,e ), grandezza confrontabile con gli attuali livelli diagnostici di riferimento (LDR). Le distribuzioni di P KA e di K a,e mostrano valori con unélevata dispersione. I valori di K a,e ottenuti risultano ampiamente inferiori ai livelli diagnostici di riferimento. Il valore di LDR è superiore a 6 volte quello del valore medio della distribuzione di K a,e valutata per gli esami addome AP e colonna lombare LAT, mentre per gli esami del torace PA tale rapporto è circa 2,7. Il metodo implementato è risultato efficace per caratterizzare la dose di ciascun esame tramite la valutazione degli indici statistici della quantità di interesse su campioni molto estesi. I valori di dose ottenuti in rapporto ai livelli diagnostici di riferimento indicano che per questo apparecchio si ha un risparmio considerevole di dose rispetto a quanto è stato valutato per apparecchi radiologici non digitali o digitali con piastre ai fosfori.
- 25 October 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (8) , 1219-1228
Patient dose evaluation by means of DICOM images for a direct radiography system
The purpose of this work was to evaluate the statistical distribution of patient dose for different examinations by using the data stored in a DICOM image archive of a direct digital radiography system. An automatic procedure to extract dose data and exposure parameters from the image archives was implemented. During a 4.5-month period, 8,292 images were collected. Exposure parameters and the air kerma area product (P KA) stored in the image DICOM header were examined for each image. The entrance surface air kerma (K a,e), a quantity comparable to the current diagnostic reference levels (DRL), was estimated considering the P KA and the geometric parameters of each examination. P KA and K a,e distributions showed highly variable values. The obtained K a,e values were substantially lower than the DRL. DRL were more than six times the mean value of K a,e distribution for the abdomen anteroposterior (AP) and lumbar spine lateral (LAT) projections, whereas the ratio was equal to 2.7 for posteroanterior (PA) chest examinations. The method adopted proved to be effective for characterising the dose of each examination by means of the statistical analysis of the dose quantities over extensive samples. The dose values obtained and the comparison with the DRL showed that this radiographic device allows substantial dose savings compared with estimations made for nondigital or for phosphor-based systems. Lo scopo di questo lavoro è stato quello di utilizzare i dati memorizzati nell’archivio DICOM delle immagini realizzate con un apparecchio digitale diretto per valutare la distribuzione statistica della dose al paziente per diversi esami. È stata implementata una procedura informatica automatizzata di estrazione dei dati di dose e dei parametri di esposizione dall’archivio delle immagini realizzate. La raccolta dei dati è stata effettuata per un periodo di quattro mesi e mezzo e per un totale di 8292 immagini. Per ciascuna immagine sono stati considerati i parametri di esposizione e il prodotto kerma per area (P KA ) memorizzati nel header dei file immagine. Considerando il P KA e i parametri geometrici di ciascun esame è stato possibile effettuare una stima di kerma superficiale in ingresso (K a,e ), grandezza confrontabile con gli attuali livelli diagnostici di riferimento (LDR). Le distribuzioni di P KA e di K a,e mostrano valori con unélevata dispersione. I valori di K a,e ottenuti risultano ampiamente inferiori ai livelli diagnostici di riferimento. Il valore di LDR è superiore a 6 volte quello del valore medio della distribuzione di K a,e valutata per gli esami addome AP e colonna lombare LAT, mentre per gli esami del torace PA tale rapporto è circa 2,7. Il metodo implementato è risultato efficace per caratterizzare la dose di ciascun esame tramite la valutazione degli indici statistici della quantità di interesse su campioni molto estesi. I valori di dose ottenuti in rapporto ai livelli diagnostici di riferimento indicano che per questo apparecchio si ha un risparmio considerevole di dose rispetto a quanto è stato valutato per apparecchi radiologici non digitali o digitali con piastre ai fosfori.
- 25 October 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (8) , 1229-1240
Radiation dose evaluations during radiological contrast studies in patients with morbid obesity
The purpose of this study was to evaluate the radiation dose to patients during radiological contrast studies performed after vertical banded gastroplasty (VBG) or Roux-en-Y gastric bypass (RYGBP) surgery in patients with morbid obesity. Dose evaluations were performed on a sample of 39 patients (32 women and 7 men) with a mean weight of 117 kg (range 68–175 kg) and a mean body mass index (BMI) of 43.7 (range 22.2–54.9). Between the second and seventh postoperative day, patients underwent radiological follow-up after oral administration of approximately 70 ml of water-soluble iodinated contrast material (Gastrografin) and images acquired in anteroposterior, right and left oblique projections with the patient upright and then supine. Exposure conditions, dose-area product (DAP) and entrance skin dose (ESD) were recorded for each procedure. On the basis of these data, the effective dose (ED) was calculated using simulation software based on the Monte Carlo method for determining the absorbed dose to organs. To assess the optimal exposure conditions and the dose contributions of fluoroscopy and radiography, the effective dose rates were also evaluated using Plexiglas phantoms of different thickness to simulate different patient sizes. The phantom measurements showed a fourfold dose increase when passing from normal-sized patients to obese patients. Mean DAP value obtained from in-vivo measurements was 70 Gy cm2 (range 17–147 Gy cm2), and mean effective dose was 21 mSv (range 5–45 mSv). When performing radiological contrast studies in patients with morbid obesity, every possible precaution should be taken to minimise patient dose. Special care should be taken to evaluate justification of the radiological procedure. Scopo del lavoro è stato quello di valutare la dose al paziente nel corso di esami contrastografici eseguiti in pazienti affetti da obesità patologica sottoposti ad interventi chirurgici di gastroplastica o bypass gastrico. Le valutazioni sono state effettuate per 39 esami, su di un campione di pazienti costituito da 32 donne e 7 uomini, con peso medio di 117 kg (intervallo 68–175 kg) e con indice di massa corporeo medio di 43,7 (intervallo 22,2–54,9). I pazienti operati nell’arco di tempo della durata dello studio sono stati sottoposti a controllo radiologico post-operatorio tra la II e la VII giornata mediante somministrazione per os di circa 70 ml di MdC iodato idrosolubile (Gastrografin) e acquisizione di radiogrammi eseguiti dapprima in ortostatismo in proiezione AP, obliqua destra e sinistra e successivamente a paziente supino. Per l’intera durata di ciascuna procedura sono state registrate le condizioni di esposizione e i valori di prodotto dose per area (DAP) e di dose di ingresso al paziente (ESD). Sulla base dei dati rilevati è stato effettuato un calcolo della dose efficace (ED) al paziente utilizzando un programma di calcolo basato sul metodo Monte Carlo per la stima della dose assorbita agli organi. Al fine di valutare le condizioni ottimali di esposizione e i contributi alla dose totale legati alla scopia e alla grafia, sono state inoltre effettuate misure di dose con fantocci di plexiglass di diversi spessori per simulare i pazienti di diversa corporatura. Le misurazioni su fantoccio hanno dimostrato che il passaggio da spessori analoghi a quelli dei pazienti normotipo a quelli dei pazienti oggetto dello studio può comportare un aumento di dose di un fattore quattro. Il valore medio di prodotto dose per area ottenuto nelle misurazioni in vivo è stato di 70 Gy cm2 (intervallo 17–147 Gy cm2), mentre il valore medio di dose efficace è stato di 21 mSv (intervallo 5–45 mSv). Nell’esecuzione di esami contrastografici in pazienti obesi occorre adottare tutte le precauzioni possibili per ridurre al minimo la dose al paziente. Particolare attenzione deve essere posta alla giustificazione dell’esame.
- 25 October 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (8) , 1229-1240
Radiation dose evaluations during radiological contrast studies in patients with morbid obesity
The purpose of this study was to evaluate the radiation dose to patients during radiological contrast studies performed after vertical banded gastroplasty (VBG) or Roux-en-Y gastric bypass (RYGBP) surgery in patients with morbid obesity. Dose evaluations were performed on a sample of 39 patients (32 women and 7 men) with a mean weight of 117 kg (range 68–175 kg) and a mean body mass index (BMI) of 43.7 (range 22.2–54.9). Between the second and seventh postoperative day, patients underwent radiological follow-up after oral administration of approximately 70 ml of water-soluble iodinated contrast material (Gastrografin) and images acquired in anteroposterior, right and left oblique projections with the patient upright and then supine. Exposure conditions, dose-area product (DAP) and entrance skin dose (ESD) were recorded for each procedure. On the basis of these data, the effective dose (ED) was calculated using simulation software based on the Monte Carlo method for determining the absorbed dose to organs. To assess the optimal exposure conditions and the dose contributions of fluoroscopy and radiography, the effective dose rates were also evaluated using Plexiglas phantoms of different thickness to simulate different patient sizes. The phantom measurements showed a fourfold dose increase when passing from normal-sized patients to obese patients. Mean DAP value obtained from in-vivo measurements was 70 Gy cm2 (range 17–147 Gy cm2), and mean effective dose was 21 mSv (range 5–45 mSv). When performing radiological contrast studies in patients with morbid obesity, every possible precaution should be taken to minimise patient dose. Special care should be taken to evaluate justification of the radiological procedure. Scopo del lavoro è stato quello di valutare la dose al paziente nel corso di esami contrastografici eseguiti in pazienti affetti da obesità patologica sottoposti ad interventi chirurgici di gastroplastica o bypass gastrico. Le valutazioni sono state effettuate per 39 esami, su di un campione di pazienti costituito da 32 donne e 7 uomini, con peso medio di 117 kg (intervallo 68–175 kg) e con indice di massa corporeo medio di 43,7 (intervallo 22,2–54,9). I pazienti operati nell’arco di tempo della durata dello studio sono stati sottoposti a controllo radiologico post-operatorio tra la II e la VII giornata mediante somministrazione per os di circa 70 ml di MdC iodato idrosolubile (Gastrografin) e acquisizione di radiogrammi eseguiti dapprima in ortostatismo in proiezione AP, obliqua destra e sinistra e successivamente a paziente supino. Per l’intera durata di ciascuna procedura sono state registrate le condizioni di esposizione e i valori di prodotto dose per area (DAP) e di dose di ingresso al paziente (ESD). Sulla base dei dati rilevati è stato effettuato un calcolo della dose efficace (ED) al paziente utilizzando un programma di calcolo basato sul metodo Monte Carlo per la stima della dose assorbita agli organi. Al fine di valutare le condizioni ottimali di esposizione e i contributi alla dose totale legati alla scopia e alla grafia, sono state inoltre effettuate misure di dose con fantocci di plexiglass di diversi spessori per simulare i pazienti di diversa corporatura. Le misurazioni su fantoccio hanno dimostrato che il passaggio da spessori analoghi a quelli dei pazienti normotipo a quelli dei pazienti oggetto dello studio può comportare un aumento di dose di un fattore quattro. Il valore medio di prodotto dose per area ottenuto nelle misurazioni in vivo è stato di 70 Gy cm2 (intervallo 17–147 Gy cm2), mentre il valore medio di dose efficace è stato di 21 mSv (intervallo 5–45 mSv). Nell’esecuzione di esami contrastografici in pazienti obesi occorre adottare tutte le precauzioni possibili per ridurre al minimo la dose al paziente. Particolare attenzione deve essere posta alla giustificazione dell’esame.
- 1 April 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (3) , 429-438
Interventional procedures for biliary drainage with bilioplasty in paediatric patients: dosimetric aspects
This study was undertaken to evaluate patient dose in paediatric liver transplant recipients treated by percutaneous biliary drainage and bilioplasty procedures. Effective dose rates and entrance skin-dose (ESD) rates per minute of fluoroscopy were measured by using a plexiglas phantom (thickness 10 cm) simulating the patient and by varying the exposure parameters (type of pulsed fluoroscopy, image intensifier diameter, presence of diaphragms) to identify the technique delivering the lowest patient dose. In vivo measurements were performed during three interventional procedures. The effective dose rate proved to be lowest for a particular type of pulsed fluoroscopy, with maximum magnification and with field-limiting diaphragms. The in vivo measurements showed a maximum ESD value of around 50 MGY (the threshold for transient erythema is 2,000 MGY, ICRP 60). The effective dose values were in the range of 0.9-1.5 MSV. We established exposure parameters providing the desired image quality with the lowest dose for the equipment used and for a specific type of interventional procedure. The measured ESD values allow us to exclude the risk of deterministic effects on the skin. The effective dose values and considerations regarding the likelihood of radiation-induced cancer led to the conclusion that the radiological risk for the patient is largely justified by the benefits of these kinds of procedure.
- 1 April 2008
- Published by Springer Nature in La radiologia medica
- Vol. 113 (3) , 429-438
Interventional procedures for biliary drainage with bilioplasty in paediatric patients: dosimetric aspects
This study was undertaken to evaluate patient dose in paediatric liver transplant recipients treated by percutaneous biliary drainage and bilioplasty procedures. Effective dose rates and entrance skin-dose (ESD) rates per minute of fluoroscopy were measured by using a plexiglas phantom (thickness 10 cm) simulating the patient and by varying the exposure parameters (type of pulsed fluoroscopy, image intensifier diameter, presence of diaphragms) to identify the technique delivering the lowest patient dose. In vivo measurements were performed during three interventional procedures. The effective dose rate proved to be lowest for a particular type of pulsed fluoroscopy, with maximum magnification and with field-limiting diaphragms. The in vivo measurements showed a maximum ESD value of around 50 MGY (the threshold for transient erythema is 2,000 MGY, ICRP 60). The effective dose values were in the range of 0.9-1.5 MSV. We established exposure parameters providing the desired image quality with the lowest dose for the equipment used and for a specific type of interventional procedure. The measured ESD values allow us to exclude the risk of deterministic effects on the skin. The effective dose values and considerations regarding the likelihood of radiation-induced cancer led to the conclusion that the radiological risk for the patient is largely justified by the benefits of these kinds of procedure.
- 30 October 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (23) , N403-N409
Dose area product evaluations with Gafchromic®XR-R films and a flat-bed scanner
Gafchromic XR-R films are a useful tool to evaluate entrance skin dose in interventional radiology. Another dosimetric quantity of interest in diagnostic and interventional radiology is the dose area product (DAP). In this study, a method to evaluate DAP using Gafchromic XR-R films and a flat-bed scanner was developed and tested. Film samples were exposed to an x-ray beam of 80 kVp over a dose range of 0-10 Gy. DAP measurements with films were obtained from the digitalization of a film sample positioned over the x-ray beam window during the exposure. DAP values obtained with this method were compared for 23 cardiological interventional procedures with DAP values displayed by the equipment. The overall one-sigma dose measurement uncertainty depended on the absorbed dose, with values below 6% for doses above 1 Gy. A maximum discrepancy of 16% was found, which is of the order of the differences in the DAP measurements that may occur with different calibration procedures. Based on the results presented, after an accurate calibration procedure and a thorough inspection of the relationship between the actual dose and the direct measured quantity (net optical density or net pixel value variation), Gafchromic XR-R films can be used to assess the DAP.
- 30 October 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (23) , N403-N409
Dose area product evaluations with Gafchromic®XR-R films and a flat-bed scanner
Gafchromic XR-R films are a useful tool to evaluate entrance skin dose in interventional radiology. Another dosimetric quantity of interest in diagnostic and interventional radiology is the dose area product (DAP). In this study, a method to evaluate DAP using Gafchromic XR-R films and a flat-bed scanner was developed and tested. Film samples were exposed to an x-ray beam of 80 kVp over a dose range of 0-10 Gy. DAP measurements with films were obtained from the digitalization of a film sample positioned over the x-ray beam window during the exposure. DAP values obtained with this method were compared for 23 cardiological interventional procedures with DAP values displayed by the equipment. The overall one-sigma dose measurement uncertainty depended on the absorbed dose, with values below 6% for doses above 1 Gy. A maximum discrepancy of 16% was found, which is of the order of the differences in the DAP measurements that may occur with different calibration procedures. Based on the results presented, after an accurate calibration procedure and a thorough inspection of the relationship between the actual dose and the direct measured quantity (net optical density or net pixel value variation), Gafchromic XR-R films can be used to assess the DAP.
- 24 May 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (11) , 2871-2881
Dose and energy dependence of response of Gafchromic® XR-QA film for kilovoltage x-ray beams
There is a growing interest in Gafchromic films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.
- 24 May 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (11) , 2871-2881
Dose and energy dependence of response of Gafchromic® XR-QA film for kilovoltage x-ray beams
There is a growing interest in Gafchromic films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.
- 1 March 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (6) , 1577-1593
Quantitative assessment of computed radiography quality control parameters
Quality controls for testing the performance of computed radiography (CR) systems have been recommended by manufacturers and medical physicists' organizations. The purpose of this work was to develop a set of image processing tools for quantitative assessment of computed radiography quality control parameters. Automatic image analysis consisted in detecting phantom details, defining regions of interest and acquiring measurements. The tested performance characteristics included dark noise, uniformity, exposure calibration, linearity, low-contrast and spatial resolution, spatial accuracy, laser beam function and erasure thoroughness. CR devices from two major manufacturers were evaluated. We investigated several approaches to quantify the detector response uniformity. We developed methods to characterize the spatial accuracy and resolution properties across the entire image area, based on the Fourier analysis of the image of a fine wire mesh. The implemented methods were sensitive to local blurring and allowed us to detect a local distortion of 4% or greater in any part of an imaging plate. The obtained results showed that the developed image processing tools allow us to implement a quality control program for CR with short processing time and with absence of subjectivity in the evaluation of the parameters.
- 1 March 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (6) , 1577-1593
Quantitative assessment of computed radiography quality control parameters
Quality controls for testing the performance of computed radiography (CR) systems have been recommended by manufacturers and medical physicists' organizations. The purpose of this work was to develop a set of image processing tools for quantitative assessment of computed radiography quality control parameters. Automatic image analysis consisted in detecting phantom details, defining regions of interest and acquiring measurements. The tested performance characteristics included dark noise, uniformity, exposure calibration, linearity, low-contrast and spatial resolution, spatial accuracy, laser beam function and erasure thoroughness. CR devices from two major manufacturers were evaluated. We investigated several approaches to quantify the detector response uniformity. We developed methods to characterize the spatial accuracy and resolution properties across the entire image area, based on the Fourier analysis of the image of a fine wire mesh. The implemented methods were sensitive to local blurring and allowed us to detect a local distortion of 4% or greater in any part of an imaging plate. The obtained results showed that the developed image processing tools allow us to implement a quality control program for CR with short processing time and with absence of subjectivity in the evaluation of the parameters.