JNJ. Neuerburg

J. Neuerburg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. Neuerburg has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Can that be Really True?

    by G. Adam, G. Alzen, K. Bohndorf, A. Bücker, P. Haage, H.-M. Klein, Ch. Müller-Leisse, J. Neuerburg, C. Nolte-Ernsting, Th. Schmitz-Rode, et al.

    Für uns jedoch, die ihre Jugend- und Lehrzeit mit ihm verbracht haben oder noch verbringen, ist er immer noch der alte junge Chef und akademische Lehrer, der vor Tatendrang und Ideen wie vor 20 Jahren unentwegt sprüht. Eine Art wissenschaftliche Dauerwunderkerze. Während manch 60-Jähriger im Garten Rosen schneidet, schneidet Rolf Günther als flotter Autofahrer Kurven und schneidert an neuen Ideen für unser Fach, wobei ein perfekt sitzender Maßanzug das Minimalziel darstellt. Die Talente von R. W. Günther aufzuzählen würde den Rahmen dieses Heftes sprengen. Eine Auswahl für die nicht so Eingeweihten: Singen, Klavierspielen, eben ein ausgeprägter Sinn für das Musische, Handstand, Freude an gutem Essen und Trinken und ein nicht zu bändigender Arbeitseifer sind einige der wesentlichen Merkmale. Die Stunden auf Kongressen sind unvergessen, wenn nach einem langen Arbeitstag R. W. Günther seine Mannschaft zum „Absacker”, einem „real dirty stinker”, einer Art ritueller Verabschiedung des Tages rief, der alle bis auf einen endgültig in den Tiefschlaf beförderte. Auch zu Hause fehlte nie ein Eindringliches: Auf, auf! Was ist los? Madre de dios! Kann's los gehen?, wenn der Chef zur morgendlichen Weiterbildung rief und ruft. Selbst an von einer gewissen Trägheit geprägten Tagen wie z. B. nach Klinikfesten war dieser an Arbeit mahnende Ruf nicht zu überhören, der uns aufforderte, nicht zu übersehen, was die Günther'sche Großmutter selbst ohne Brille sah. Widrige äußere Umstände wie ein halb abgebranntes Klinikum, das unsere radiologische Klinik zum Umzug in Notunterkünfte wie etwa Briefkästen und Arbeitswarentransportanlagen zwang, stellten kein Hindernis für Günther'schen Tatendrang und seine sprudelnde Vielfalt in Aachen dar. Unvergessen auch die Zeit, als eine Abwanderung von R. W. Günther in den Süden drohte. Die Klinik, von Studenten fackeldurchzogen, glich phasenweise einem Wettbüro: Geht er oder geht er nicht? Große Erleichterung verbreitete sich bei der Ankündigung des Bleibens. Die Wettschulden, stets Ehrenschulden, keine Bringschulden, waren schnell vergessen. Die Auflistung von Ehrenmitgliedschaften und Auszeichnungen können wir guten Gewissens den Herausgebern der RöFo überlassen. Der uns zugestandene Platz würde hierfür nicht ausreichen. Wir dürfen die Gelegenheit nutzen und uns für die spannende, schöne und produktive Zeit im Hause Günther bedanken. Um in der Diktion des Jubilars zu bleiben: Es hat großen Spaß gemacht! Wir wünschen Rolf W. Günther viel Glück und Gesundheit zum 60. Geburtstag! Und, wir sind uns sicher: Jetzt geht's erst richtig los! G. Adam, Hamburg G. Alzen, Gießen K. Bohndorf, Augsburg A. Bücker, Aachen P. Haage, Aachen H.-M.Klein, DaadenCh. Müller-Leisse, Mönchengladbach J. Neuerburg, Duisburg C. NoIte-Ernsting, Hamburg Th. Schmitz-Rode, Aachen K. Schürmann, Aachen G. Staatz, Aachen J. Tacke, Aachen D. Vorwerk, Ingolstadt B. Wein, Aachen J. Wildberger, Aachen und alle Mitarbeiterinnen und Mitarbeiter der Klinik für Radiologische Diagnostik der RWTH Aachen. Herausgeber und Mitwirkende der RöFo sowie des Thieme Verlags schließen sich den herzlichen Glückwünschen an.

  • Diagnostik und Darstellung von Stenosen der Arteria renalis mittels Farbkodierter Dopplersonographie - Vergleich von zentraler und peripherer Flußableitung -

    by A. Ruebben, W. Piroth, J. Neuerburg, J. E. Wildberger, T. Schmitz-Rode, R. W. Günther

    Zielsetzung: Vergleich von zentraler und peripherer Flußableitung mittels Farbkodierter Dopplersonographie im Nachweis hämodynamisch relevanter Nierenarterienstenosen. Material und Methoden: In einer prospektiven Studie an 66 Patienten wurden die maximale systolische Geschwindigkeit (zentrale Messung) und der Akzelerationsindex (periphere Messung) mittels Farb-Doppler-Untersuchungen zur Diagnostik und Darstellung von Nierenarterienstenosen ermittelt. Ergaben zentrale und periphere Messungen einen unauffälligen Befund, wurde auf weitere diagnostische Maßnahmen verzichtet. Bei pathologischem Befund in einem der beiden Verfahren (21 Fälle) oder bei unklarem Befund (2 Fälle) erfolgte eine digitale Subtraktionsangiographie. Ergebnisse: Bei 49 von 66 Patienten lag eine Übereinstimmung zwischen peripherer und zentraler Messung vor. Bei zehn Patienten zeigten periphere und zentrale Messung unterschiedliche Befunde. In sieben Fällen lieferte die periphere Messung keine eindeutige Aussage. Verglichen mit der Subtraktionsangiographie ergaben sich bei der peripheren Messung eine Sensitivität von 60 %, eine Spezifität von 75 % und ein positiver Vorhersagewert von 81,8 %. Demgegenüber zeigte die zentrale Flußableitung eine Sensitivität von 100 %, eine Spezifität von 75 % und einen posiven Vorhersagewert von 88,2 %. Schlußfolgerungen: Die Bestimmung der maximalen systolischen Flußgeschwindigkeit stellt eine effektive Methode zur Erkennung von Nierenarterienstenosen dar. Purpose: Comparison between central and peripheral flow patterns with color-coded duplex sonography in the diagnosis of renal artery stenosis. Materials and methods: In a prospective study with sixty-six patients systolic velocity (central examination) and acceleration index (peripheral examination) were determined using color-coded duplex sonography examination in order to detect and visualize renal artery stenosis. lf the central and peripheral measurements were negative, no angiography was performed. In contrast, if one of the methods yielded a pathological finding, catheter angiography was performed to verify the results (21 patients), as well as in two other unclear cases. Results: An agreement between central and peripheral measuring was seen in 49 of 66 patients. In ten patients central and peripheral measurements showed different results. In seven cases the peripheral measurements were not clear. Compared to angiography, peripheral measurement showed a sensitivity of 60 %, a specificity of 75 % and a positive predictive value of 81.8 %. In contrast, central examination had a sensitivity of 100 %, a specificity of 75 % and a positive predictive value of 88.2 %. Conclusions: Based on our preliminary results, the measurement of the systolic velocity peak seems to be an effective method to detect renal artery stenosis.


  • Neues MR-(und CT-)kompatibles Knochenbiopsiesystem: Erste klinische Ergebnisse

    by J. Neuerburg, G. Adam, A. Bücker, K. W. Zilkens, T. Schmitz-Rode, F. J. Katterbach, B. Klosterhalfen, E. Rasmussen, J. Vaals, R. W. Günther

    Ziel: Entwicklung und klinische Erprobung eines MRT- und CT-kompatiblen Biopsiesystems mit wahlweise manuellem oder pneumatischem Antrieb zur perkutanen Histologiegewinnung aus Knochenläsionen. Material und Methode: Das neu entwickelte Biopsiesystem setzt sich zusammen aus einer 12G-Führhülse mit Trokar, einem 14G-Hohlbohrer, einem Kunststoffhandgriff mit Luer-Adapter für manuelles Bohren sowie einem pneumatischen Turbinenantrieb mit stufenlos regelbarem Druckluftregulierpedal (10-250 U/min bei 6 bar) für maschinell unterstütztes Bohren. Das System wurde zur MRT-gesteuerten Knochenpunktion an einem 1,5 T Philips-Gyroscan ACS-NT in Verbindung mit einem mobilen Röntgen-C-Bogen (14 Patienten) und zur CT-gesteuerten Knochenpunktion an einem Somatom Plus (9 Patienten) getestet. Ergebnisse: Die Handhabung des Knochenbiopsiesystems im MRT- und im CT-Untersuchungsraum war bei manueller und bei turbinenunterstützter Bohrung einfach, sicher und zuverlässig. Die MR-tomographische und die computertomographische Lokalisation von Führhülse und Bohrer in Weichgewebe und Knochen war möglich. 18 der 23 Biopsien lieferten eine histologisch eindeutige und mit dem radiologischen Befund und dem klinischen Verlauf vereinbare Diagnose. Bohrerbedingte Komplikationen wurden nicht beobachtet. Schlußfolgerung: Das vorgestellte Knochenbiopsiesystem eignet sich zur MRT- oder CT-gesteuerten perkutanen Histologiegewinnung auch aus stark sklerosierten Knochenläsionen. Purpose: To describe the development and clinical evaluation of a new, hand-powered or alternatively motor-driven, MRI and CT compatible percutaneous bone biopsy system. Materials and Methods: A new coaxial drill system (Cook Europe A/5) was designed for percutaneous, MR-guided bone biopsies and powered either by hand or an optional motor (10-250 rotations/minute using 6 bar [88.2 PSI] compressed air). The system has been used in 23 patients. Fourteen procedures were performed in a 1.5 T MR scanner (Philips-Gyroscan ACS-NT) which has an attached C-arm (Philips-BV 212-Angio) in case fluoroscopy is required, and 9 procedures in a CT scanner (Siemens-Somatom Plus). Results: Driven by hand or by the pneumatic motor unit, the system achieved safe and accurate MR-guided access to all of the lesions and was even able to penetrate osteosclerotic lesions. MR- or CT-guided percutaneous biopsy yielded a correct diagnosis in all but 5 cases. No procedural complications occurred. Conclusion: MR-guided percutaneous bone biopsy performed with the new coaxial drill system was found to be safe and reliable, and suitable for obtaining histological specimens from skeletal lesions even when covered with thick cortical or sclerotic bone.


  • MR-gesteuerte Biopsien mit einer hochauflösenden schnellen T2-gewichteten Turbo-Spin-Echo-Sequenz „LoLo”: Erste klinische Erfahrungen

    by A. Bücker, G. Adam, J. Neuerburg, A. Glowinski, J. van Vaals, R. Günther

    Ziel: Die Möglichkeit des Einsatzes der „LoLo”-Technik für MR-gesteuerte Biopsien wurde getestet. Material und Methode: 10 Patienten wurden an einem 1,5 T System kernspintomographisch gesteuert punktiert. Bei der „LoLo”-Technik handelt es sich um eine Turbo-Spin-Echo-Sequenz, die alle k-Raumprofile nach einer einzelnen Anregung akquiriert. Die Verwendung eines kleinen Meßfeldes ermöglicht es, Bilder mit einer Auflösung von 1 mm2 in 600 ms zu erhalten. Hierbei verhindert die orthogonale Anordnung der schichtselektiven Radiofrequenzpulse zueinander das Auftreten von Einfaltungsartefakten. Ergebnisse: Alle Punktionen konnten komplikationslos durchgeführt werden und ergaben ausreichendes Material zur Diagnosestellung. Die Spitze der Punktionsnadel war mit Hilfe der „LoLo”-Technik jeweils gut abgrenzbar. Sämtliche Aufnahmen zeigten einen für T2-gewichtete Turbo-Spin-Echo-Aufnahmen typischen Kontrast. Einfaltungsartefakte traten nicht auf. Schlußfolgerung: Die „LoLo”-Technik ermöglicht eine schnelle Bildgebung bei MR-gesteuerten Punktionen. Gegenüber Gradienten-Echo-Techniken weist sie die Vorteile einer T2-Wichtung und einer geringeren Anfälligkeit für Suszeptibilitätsartefakte auf. Purpose: The feasability of the "LoLo"-technique for MR guidance of biopsy procedures was tested. Material and Methods: MR-guided biopsies were performed on 10 patients employing a 1.5 T system. The "LoLo"-technique used is a single shot turbo spin echo technique. Only a small field of view is covered in order to yield images with a resolution of 1 mm2 in 600 ms. The orthogonal orientation of the slice selective radio frequency pulses to each other prevents foldover artifacts. Results: No complications occurred. All biopsy procedures yielded sufficient material to diagnose the underlying disease. The "LoLo"-technique enabled good depiction of the needle tip in all cases. T2-weighted contrast typical for turbo spin echo images was observed. No foldover artifacts were detectable. Conclusion: MR-guided biopsies are possible with the "LoLo"-technique. Compared to gradient echo sequences T2-weighting and smaller susceptibility artifacts proved to be advantageous.


    • 1 October 1997
      • Vol. 36  (7) , 234-9

    [Comparison of findings with 18-FDG PET and CT in pretherapeutic staging of malignant lymphoma].

    by R Thill, J Neuerburg, U Fabry, U Cremerius, G Wagenknecht, D Hellwig, R Osieka, R Günther, U Büll

    Comparison of diagnostic efficiency of FDG-PET and CT regarding localisation, histology, size and FDG-uptake of a lesion. CT- and FDG-PET studies of 27 patients with histologically confirmed malignant lymphoma as primary disease or relapse were evaluated retrospectively. In CT lesions with a diameter (DCT) > 15 mm were regarded as positive. Focal accumulations of FDG, not explained by physiological metabolism, found by visual interpretation in iterative reconstructed PET-scans, were quantified for diameter (DPET) and corrected standardized uptake value (SUV), corrected for partial-volume-effect. Lesions were classified depending on histology and lesion quality (lymph nodes, bulks, extranodal lesions). CT detected 78 lesions in 26 patients, all confirmed by FDG-PET. PET localized 18 additional lesions (+23%); in high grade NHL +25%. Both methods were equally efficient in cervical lymph nodes and lung lesions, in all other regions of lymphatic nodules and in case of liver and spleen lesions PET localized more lesions. SUV was significantly higher in high-grade NHL (19.0) than in low-grade NHL and Hodgkin's disease (10.6 resp. 11.1). DCT and DPET correlated significantly (r = 0.75). Diagnostic efficiency of FDG-PET is equivalent or superior to CT in staging of malignant lymphoma before therapy. Qualitative interpretation seems sufficient for staging, quantitative analysis may add information about malignancy grade in NHL.


  • Kavafilterimplantation unter MRT-Kontrolle: Experimentelle In vitro- und In vivo-Untersuchungen

    by J. Neuerburg, A. Bücker, C. Adam, M. Leenen, E. Rasmussen, M. Hurtak, R. Günther

    Zielsetzung: Es wurde ein Magnetresonanztomographie (MRT)-kompatibles Einführungsbesteck zur magnetresonanztomographisch gesteuerten Kavafilterimplantation entwickelt und experimentell in vitro und in vivo erprobt. Material und Methode: Die ferromagnetischen Metallteile eines handelsüblichen femoralen Einführbestecks des MR-eye™-Tulpen-Filters wurden gegen baugleiche nichtferromagnetische Bestandteile ausgetauscht und Schleuse und Diktator mit Dysprosiumoxidringen markiert. Mit diesem Besteck wurde im Flußphantom und im Tierexperiment (n = 2 Hausschweine) die antegrade MRT-gesteuerte Filterinsertion an einem 1,5 T Philips Gyroscan ACS-NT mit integriertem mobilen digitalen Subtraktionsangiographie (DSA)-fähigen C-Bogen getestet. Ergebnisse: In vitro und in vivo konnten Filtereinführbesteck, Filtereinführkatheter und Kavafilter magnetresonanztomographisch identifiziert und MR-tomographisch gesteuert positioniert werden. Die MR-tomographisch bestimmten Filterpositionen und -zentrierungen stimmten mit den anschließend erhobenen radiologischen und makroskopischen Befunden bei sämtlichen Filterabwürfen (Flußphantom n = 5; Schwein n = 2) überein. Schlußfolgerung: Entsprechend diesen ersten experimentellen Ergebnissen scheint die perkutane magnetresonanztomographisch gesteuerte Plazierung von Kavafiltern möglich zu sein. Purpose: An instrument has been developed for the introduction of caval filters which can be used with MRI; it has been investigated in in vitro and in in vivo experiments. Material and method: The ferromagnetic components of a commercially available instrument for the femoral introduction of the MR-eye™ Tulip IVC filter were changed for similar, non-ferromagnetic parts and the lock and dilator marked with dysprosium oxide rings. The instrument was used in a flow phantom and in animal experiments (two domestic pigs) in order to insert filters under MRI control on a 1.5 T Philips Gyroscan with integrated mobile digital subtraction angiography. Results: Both in vitro and in vivo, the introducer, catheter and caval filter could be identified by MRI and positioned under MRI control. The position of the filter as indicated by MRI corresponded with radiological and macroscopic findings in all cases (5 phantoms, 2 pigs). Conclusion: The early experimental results indicate that percutaneous introduction of caval filters with placement under MRI control is possible.


  • Flußrichtungssensitive Spin-Echo-MR-Angiographie

    by A. Bücker, A. Glowinski, G. Adam, J. Neuerburg, C. Nolte-Ernsting, J. Vaals, R. Günther

    Neuere Blutpoolkontrastmittel führen zu einer starken Verkürzung der T1-Zeit. Hierdurch ist es den üblichen Methoden der TOF- und Phasenkontrastangiographie auch unter Verwendung von Sättigungsbalken nicht möglich, flußrichtungssensitive Angiogramme zu erstellen. Ziel der Arbeit war es, die Hypothese zu testen, ob mit Hilfe einer speziell entwickelten Spin-Echo-Sequenz die MR-angiographische Trennung von arteriellem und venösem Fluß auch nach Kontrastmittelgabe möglich ist. Schichtselektive 90°- und 180°-Pulse wurden hierfür hinsichtlich ihrer Anregungsschichten parallel gegeneinander versetzt. Flußrichtungssensitive MR-Angiographien wurden im Rahmen von In-vitro-Versuchen mit einem Flußphantom (ohne Kontrastmittel) und in ersten In-vivo-Versuchen an Schweinen nach Gabe von Eisenoxidpartikeln angefertigt. Die vorgestellte Sequenz ermöglicht die selektive Darstellung nur einer Flußrichtung sowie eine komplette Unterdrückung stationären Gewebes, ohne daß besondere Anforderungen an den Kernspintomographen gestellt werden oder spezielle Nachverarbeitungen nötig wären. Dies gelingt durch den räumlichen Versatz der 90°- und 180°-Pulse. Hierdurch werden nur solche Protonen, die nach ihrer Anregung in die Schicht des 180°-Pulses hineinfließen, refokussiert, und somit können auch nur diese zur Signalbildung beitragen. New blood pool contrast agents yield a significant shortening of T1 of blood. Consequently, the usual techniques of time-of-flight- and phase-contrast angiographies cannot produce angiograms sensitive to one flow direction, even if saturation slabs are applied. It was our aim to test the hypothesis of displaying arterial and venous flow selectively with a specially designed spin echo sequence even after administration of contrast agents. Parallel slice selective 90°- and 180°-pulses were applied. The distance between slices could be varied. It was attempted to obtain MR angiographies that were flow sensitive for one direction only. We performed flow phantom studies without the use of contrast media and first in vivo experiments in pigs after administration of iron oxide particles. With our modified spin echo sequence unidirectional flow can be displayed, whereas stationary tissue is totally suppressed. There are no special demands for the hardware and no additional postprocessing needs to be performed. The locally off-centred 90°- and 180°-pulses are responsible for this. Exclusively protons excited by the 90°-pulse and flowing into the slice of the 180°-pulse will be refocussed, and only such protons will give rise to signal in the images.

  • Bestimmung der Effektivität perkutaner Kavafilter: Experimentelle Untersuchungen

    by J. Neuerburg, Alexandra Haupt-Pichler, F. J. Katterbach, R. Eilers, T. Sieß, Karen Buro, C. V Pichler, K. Mottaghy, R. W. Günther

    Ziel: Unter In-vitro-Bedingungen sollte die Effektivität von zur Zeit in Deutschland klinisch eingesetzten Kavafiltern ermittelt werden. Material und Methode: In einem geschlossenen Kreislaufmodell wurde in einer flexiblen „Latex-Kava” die Effizienz von 16 perkutanen Kavafiltern unter pulsatilem Fluß bei einer mittleren Flußrate von 31/min und einer Temperatur von 37 °C in horizontaler und vertikaler Flußrichtung untersucht. Nichtselbstzentrierende Filter wurden in zentrierter und in verkippter Position getestet. Pro Filter wurden je 640 bzw. 1280 zylindrisch gestanzte Schweinevollblutthromben mit 8 verschiedenen Größen injiziert. Ergebnisse: Die Gesamtfangrate der Filter lag bei optimaler Positionierung im Gefäßmodell zwischen 97,8 und 69,4 %. Die größten Emboli wurden bei optimaler Positionierung von allen Filtern gefangen. Bei Umlagerung des Kreislaufmodells von der vertikalen in die horizontale Position variierte die Effizienz der Filter im Schnitt um 4,8 %. Bei nichtselbstzentrierenden Filtern sank die Effizienz im Mittel um 15,5 % (2,7-37,7 %) bei Verkippung, so daß dann die Fangrate auf bis zu 43,2 % abfiel. Schlußfolgerung: Optimal zentrierte Kavafilter weisen im Gefäßmodell eine hohe Effektivität auf; bei Verkippung nichtselbstzentrierender Filter sinkt die Effizienz signifikant. Purpose: In vitro clot-trapping capacity of 16 different caval filters should be evaluated under varying experimental conditions. Material and methods: In a flow model simulating in vivo conditions (soft latex tube, dextran solution at 37 °C, pulsatile flow at a mean rate of 31/min) the efficiency of 16 caval filters was evaluated in horizontal and vertical position by using 640 or 1280 clots/filter (8 sizes). Non-self centering filters were tested in centric and in tilted position. Results: Efficiency of optimally centered caval filters varied between 97.8 and 69.4 %. The largest thrombi were captured by all optimal centered filters. A change from vertical to horizontal position of the flow model resulted in a variation of filter efficiency by about 4.8 %. Efficiency of non-self centering filters decreased significantly when placed in a tilted position (mean decrease 15.5 %; range 2.7 %-37.7 %) resulting in a deterioration of the capture rate by as much as 43.2 %. Conclusion: Under optimal study conditions efficiency of all evaluated caval filters was high. Tilting of caval filters resulted in a significant efficiency decrease.


  • Diagnostik und Fragmentationstherapie der akuten massiven Lungenembolie mit einem rotierbaren Pigtail–Katheter: Experimentelle Studien

    by T. Schmitz–Rode, R. W. Günther, J. Neuerburg, B. Geuting, S. Biesterfeld

    Ziel: Ein spezielles Pigtail–Kathetersystem, mit dem eine Lungenembolie diagnostiziert und unmittelbar anschließend fragmentiert werden kann, wurde im Tierexperiment erprobt. Material und Methode: Der 5–F–Katheter mit einem ovalen Seitenloch vor der Pigtail–Spitze war über einen Führungsdraht als Rotationsachse entweder manuell oder mit einem elektrischen Antrieb rotierbar. Bei zehn Hunden wurden embolische Verschlüsse der Pulmonalarterien rekanalisiert. Dabei wurden Positionierbarkeit, pulmonale Steuerbarkeit, Rotationsverhalten, Sicherheit und Fragmentationseigenschaften des Katheters untersucht. Ergebnisse: Das Kathetersystem war schnell in den Pulmonalartorien positionierbar und gut steuerbar. Durchschnittlich konnten die embolischen Verschlüsse zu 55 % (±20 %) rekanalisiert werden. Die emboliebedingte Erhöhung des pulmonalarteriellen Mitteldruckes konnte im Durchschnitt um 72 % reduziert werden. Bei drei Hunden zeigte die Histologie eine geringe perivaskuläre Hämorrhagie. Schlußfolgerung: Eine partielle Rekanalisation der Pulmonalarterien war schnell und mit geringem Instrumentieraufwand durchführbar. Die verwendete Technik basiert auf der üblichen selektiven Sondierung der Pulmonalarterien mit dem Pigtailkatheter und erfordert daher keine speziellen Kenntnisse. Purpose: A dedicated pigtail catheter system which allows angiographic documentation and adjunctive mechanical fragmentation of pulmonary emboli was evaluated in an animal experiment. Material and method: The 5–F catheter provided with an oval side hole proximal to the pigtail tip was rotated manually or with an electric drive, and with the wire as a rotation axis. Pulmonary embolic occlusions were re–canalized in ten dogs. Catheter positioning, monitoring, rotation behaviour, safety and fragmentation properties were assessed. Results: The catheter system was rapidly positioned and easily monitored in the pulmonary arteries. On average, 55 % (± 20 %) of the embolic occlusions were recanalised. Embolus fragmentation reduced the emboli–induced increase of the pulmonary arterial mean pressure by 72 %. In three dogs, histology revealed slight perivascular haemorrhage. Conclusion: Partial recanalisation of the pulmonary arteries was achieved rapidly with relative ease of instrumentation. Since fragmentation technique is an adjunct to the commonly performed pigtail catheterization of the pulmonary arteries, no special training is required.