Martin J. Lizak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin J. Lizak has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Kazuhiko Mori
Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
2 shared publicationsPeter F. Kador
National Eye Institute, National Institutes of Health, Bethesda, Maryland
2 shared publicationsFrederick A. Bettelheim
Laboratory of Mechanism of Ocular Diseases, National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA; and Chemistry Department, Adelphi University, Garden City, New York, USA
1 shared publicationJ. Samuel Zigler
Laboratory of Mechanism of Ocular Diseases, National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA
1 shared publicationRobert S. Balaban
Laboratory of Ocular Therapeutics, National Eye Institute, Bethesda, MD, 20892, USA
1 shared publicationToni L. Ceckler
Laboratory of Ocular Therapeutics, National Eye Institute, Bethesda, MD, 20892, USA
1 shared publication
Latest Publications
- 1 January 2005
- Published by Taylor & Francis in Current Eye Research
- Vol. 30 (1) , 21-25
Syneretic Response to Incremental Pressures in Calf Lenses
Purpose: Syneretic response to pressure variation of 1 atm or more has been demonstrated previously in bovine and human lenses with nuclear magnetic resonance (NMR) relaxation measurements. This study is designed to prove that a similar response is observable in smaller pressure increments closer to the normal physiological range. Methods: Excised calf eyes were enucleated, the lenses dissected out, and immersed in medium. The lenses were exposed to incremental pressures ranging from 1 to 3 atm. At each pressure increment, a series of T1-weighted and spin echo images were acquired. Each image was segmented into seven regions of interest and tabulated. Longitudinal (T1) and transverse (T2) relaxation times were calculated from numerical fits of the experimental values to a one-term exponential expression. Results: The relaxation parameters were obtained from fitting the image intensities to exponential equations, which yielded a relaxation time T and a pre-exponential factor M. The relaxation times and the pre-exponential terms of both parameters displayed linear dependence on pressure. There was no evidence of a threshold for syneretic response. Both T1 and T2 relaxation times decreased with increasing pressure. The pre-exponential term M2 increased with pressure, whereas M1 decreased with pressure; however, the slope of the latter was statistically not significantly different from zero. Conclusions: Syneretic response to pressure in calf lenses as determined by NMR relaxation measurements proved to be linearly dependent on pressure over a wide range of hydrostatic pressures. There was no range where the syneretic response was absent. These two findings allow the conclusion that the phenomenon observed hitherto at large pressure changes in vitro could be operative in vivo under physiological pressure changes during accommodation.
- 1 January 2005
- Published by Taylor & Francis in Current Eye Research
- Vol. 30 (1) , 21-25
Syneretic Response to Incremental Pressures in Calf Lenses
Purpose: Syneretic response to pressure variation of 1 atm or more has been demonstrated previously in bovine and human lenses with nuclear magnetic resonance (NMR) relaxation measurements. This study is designed to prove that a similar response is observable in smaller pressure increments closer to the normal physiological range. Methods: Excised calf eyes were enucleated, the lenses dissected out, and immersed in medium. The lenses were exposed to incremental pressures ranging from 1 to 3 atm. At each pressure increment, a series of T1-weighted and spin echo images were acquired. Each image was segmented into seven regions of interest and tabulated. Longitudinal (T1) and transverse (T2) relaxation times were calculated from numerical fits of the experimental values to a one-term exponential expression. Results: The relaxation parameters were obtained from fitting the image intensities to exponential equations, which yielded a relaxation time T and a pre-exponential factor M. The relaxation times and the pre-exponential terms of both parameters displayed linear dependence on pressure. There was no evidence of a threshold for syneretic response. Both T1 and T2 relaxation times decreased with increasing pressure. The pre-exponential term M2 increased with pressure, whereas M1 decreased with pressure; however, the slope of the latter was statistically not significantly different from zero. Conclusions: Syneretic response to pressure in calf lenses as determined by NMR relaxation measurements proved to be linearly dependent on pressure over a wide range of hydrostatic pressures. There was no range where the syneretic response was absent. These two findings allow the conclusion that the phenomenon observed hitherto at large pressure changes in vitro could be operative in vivo under physiological pressure changes during accommodation.
- 1 October 2001
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 17 (5) , 475-483
Determination of Aldose Reductase Activity in the Eye by Localized Magnetic Resonance Spectroscopy
The polyol pathway plays an important role in the formation of diabetic complications of the eye. Due to variations in the pharmacokinetic properties of aldose reductase inhibitors and variations in the degradation of the blood-ocular barrier, it is often difficult to determine the proper intraocular levels of aldose reductase inhibitor required for inhibition of aldose reductase activity in ocular tissues. Utilizing localized magnetic resonance spectroscopy (MRS), the present method can determine adequate inhibition of aldose reductase activity in the lens by noninvasively measuring polyol pathway activity in the eye. New Zealand White rabbits, under anesthesia, were administered an intravitreal injection of 3-fluoro-3-deoxy-D-glucose (3FDG). Localized MRS was then used to assess polyol pathway activity by determining the levels of 3-fluoro-3-deoxy-D-sorbitol (3FS) and 3-fluoro-3-deoxy-D-fructose (3FF) metabolite formation from 3FDG in the eye. MRS was able to follow the loss of 3FDG from the vitreous into the anterior segment of the eye and particularly into the lens and aqueous. The primary metabolism of 3FDG observed by MRS was the formation of 3FS in the lens that is catalyzed by aldose reductase. Production of 3FS was linear in time and decreased with the oral administration of an aldose reductase inhibitor.
- 1 October 2001
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 17 (5) , 475-483
Determination of Aldose Reductase Activity in the Eye by Localized Magnetic Resonance Spectroscopy
The polyol pathway plays an important role in the formation of diabetic complications of the eye. Due to variations in the pharmacokinetic properties of aldose reductase inhibitors and variations in the degradation of the blood-ocular barrier, it is often difficult to determine the proper intraocular levels of aldose reductase inhibitor required for inhibition of aldose reductase activity in ocular tissues. Utilizing localized magnetic resonance spectroscopy (MRS), the present method can determine adequate inhibition of aldose reductase activity in the lens by noninvasively measuring polyol pathway activity in the eye. New Zealand White rabbits, under anesthesia, were administered an intravitreal injection of 3-fluoro-3-deoxy-D-glucose (3FDG). Localized MRS was then used to assess polyol pathway activity by determining the levels of 3-fluoro-3-deoxy-D-sorbitol (3FS) and 3-fluoro-3-deoxy-D-fructose (3FF) metabolite formation from 3FDG in the eye. MRS was able to follow the loss of 3FDG from the vitreous into the anterior segment of the eye and particularly into the lens and aqueous. The primary metabolism of 3FDG observed by MRS was the formation of 3FS in the lens that is catalyzed by aldose reductase. Production of 3FS was linear in time and decreased with the oral administration of an aldose reductase inhibitor.
- 1 January 1995
- Published by Taylor & Francis in Current Eye Research
- Vol. 14 (11) , 1035-1040
Magnetic resonance imaging of the galactosemic dog eye using magnetization transfer contrast
Magnetization transfer contrast (MTC) enhanced magnetic resonance (MR) imaging is a technique that generates high contrast images based on characteristic tissue differences resulting from the interaction of water and macromolecules. In this study, the feasibility of applying this technique to documenting the progression of osmotic sugar cataract formation was investigated in male beagles, initially 6 or 24 month old, fed a diet containing 30% galactose. MTC enhanced magnetic resonance imaging was periodically conducted on these animal's eyes at 2-Tesla. The lens MR images were compared to photographs obtained by photo-slit lamp and retroillumination photography. The MTC technique provided improved image details of the lens and anterior segment that documented osmotic changes from initial cortical vacuole formation to cortical and nuclear changes associated with advanced sugar cataracts. The latter could not be observed by photo-slit lamp or retroillumination photography.
- 1 January 1995
- Published by Taylor & Francis in Current Eye Research
- Vol. 14 (11) , 1035-1040
Magnetic resonance imaging of the galactosemic dog eye using magnetization transfer contrast
Magnetization transfer contrast (MTC) enhanced magnetic resonance (MR) imaging is a technique that generates high contrast images based on characteristic tissue differences resulting from the interaction of water and macromolecules. In this study, the feasibility of applying this technique to documenting the progression of osmotic sugar cataract formation was investigated in male beagles, initially 6 or 24 month old, fed a diet containing 30% galactose. MTC enhanced magnetic resonance imaging was periodically conducted on these animal's eyes at 2-Tesla. The lens MR images were compared to photographs obtained by photo-slit lamp and retroillumination photography. The MTC technique provided improved image details of the lens and anterior segment that documented osmotic changes from initial cortical vacuole formation to cortical and nuclear changes associated with advanced sugar cataracts. The latter could not be observed by photo-slit lamp or retroillumination photography.