MLMartin J. Lizak

Martin J. Lizak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin J. Lizak has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Kazuhiko Mori

    Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan

    2 shared publications
  • Peter F. Kador

    National Eye Institute, National Institutes of Health, Bethesda, Maryland

    2 shared publications
  • Frederick A. Bettelheim

    Laboratory of Mechanism of Ocular Diseases, National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA; and Chemistry Department, Adelphi University, Garden City, New York, USA

    1 shared publication
  • J. Samuel Zigler

    Laboratory of Mechanism of Ocular Diseases, National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA

    1 shared publication
  • Robert S. Balaban

    Laboratory of Ocular Therapeutics, National Eye Institute, Bethesda, MD, 20892, USA

    1 shared publication
  • Toni L. Ceckler

    Laboratory of Ocular Therapeutics, National Eye Institute, Bethesda, MD, 20892, USA

    1 shared publication

Latest Publications

  • Syneretic Response to Incremental Pressures in Calf Lenses

    by Martin J. Lizak, J. Samuel Zigler, Frederick A. Bettelheim

    Purpose: Syneretic response to pressure variation of 1 atm or more has been demonstrated previously in bovine and human lenses with nuclear magnetic resonance (NMR) relaxation measurements. This study is designed to prove that a similar response is observable in smaller pressure increments closer to the normal physiological range. Methods: Excised calf eyes were enucleated, the lenses dissected out, and immersed in medium. The lenses were exposed to incremental pressures ranging from 1 to 3 atm. At each pressure increment, a series of T1-weighted and spin echo images were acquired. Each image was segmented into seven regions of interest and tabulated. Longitudinal (T1) and transverse (T2) relaxation times were calculated from numerical fits of the experimental values to a one-term exponential expression. Results: The relaxation parameters were obtained from fitting the image intensities to exponential equations, which yielded a relaxation time T and a pre-exponential factor M. The relaxation times and the pre-exponential terms of both parameters displayed linear dependence on pressure. There was no evidence of a threshold for syneretic response. Both T1 and T2 relaxation times decreased with increasing pressure. The pre-exponential term M2 increased with pressure, whereas M1 decreased with pressure; however, the slope of the latter was statistically not significantly different from zero. Conclusions: Syneretic response to pressure in calf lenses as determined by NMR relaxation measurements proved to be linearly dependent on pressure over a wide range of hydrostatic pressures. There was no range where the syneretic response was absent. These two findings allow the conclusion that the phenomenon observed hitherto at large pressure changes in vitro could be operative in vivo under physiological pressure changes during accommodation.


  • Determination of Aldose Reductase Activity in the Eye by Localized Magnetic Resonance Spectroscopy

    by Martin J. Lizak, Kazuhiko Mori, Peter F. Kador

    The polyol pathway plays an important role in the formation of diabetic complications of the eye. Due to variations in the pharmacokinetic properties of aldose reductase inhibitors and variations in the degradation of the blood-ocular barrier, it is often difficult to determine the proper intraocular levels of aldose reductase inhibitor required for inhibition of aldose reductase activity in ocular tissues. Utilizing localized magnetic resonance spectroscopy (MRS), the present method can determine adequate inhibition of aldose reductase activity in the lens by noninvasively measuring polyol pathway activity in the eye. New Zealand White rabbits, under anesthesia, were administered an intravitreal injection of 3-fluoro-3-deoxy-D-glucose (3FDG). Localized MRS was then used to assess polyol pathway activity by determining the levels of 3-fluoro-3-deoxy-D-sorbitol (3FS) and 3-fluoro-3-deoxy-D-fructose (3FF) metabolite formation from 3FDG in the eye. MRS was able to follow the loss of 3FDG from the vitreous into the anterior segment of the eye and particularly into the lens and aqueous. The primary metabolism of 3FDG observed by MRS was the formation of 3FS in the lens that is catalyzed by aldose reductase. Production of 3FS was linear in time and decreased with the oral administration of an aldose reductase inhibitor.


  • Magnetic resonance imaging of the galactosemic dog eye using magnetization transfer contrast

    by Kazuhiko Mori, Martin J. Lizak, Toni L. Ceckler, Robert S. Balaban, Peter F. Kador

    Magnetization transfer contrast (MTC) enhanced magnetic resonance (MR) imaging is a technique that generates high contrast images based on characteristic tissue differences resulting from the interaction of water and macromolecules. In this study, the feasibility of applying this technique to documenting the progression of osmotic sugar cataract formation was investigated in male beagles, initially 6 or 24 month old, fed a diet containing 30% galactose. MTC enhanced magnetic resonance imaging was periodically conducted on these animal's eyes at 2-Tesla. The lens MR images were compared to photographs obtained by photo-slit lamp and retroillumination photography. The MTC technique provided improved image details of the lens and anterior segment that documented osmotic changes from initial cortical vacuole formation to cortical and nuclear changes associated with advanced sugar cataracts. The latter could not be observed by photo-slit lamp or retroillumination photography.