Jean-Louis Selam
Research Subjects
Jean-Louis Selam has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Christoph Koenen
2 shared publications- Luigi Meneghini
University of Miami
2 shared publications Wayne Weng
2 shared publicationsLuigi F. Meneghini
University of Miami Miller School of Medicine
1 shared publication
Latest Publications
- Open Access
- 1 May 2010
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 4 (3) , 505-513
Evolution of Diabetes Insulin Delivery Devices
The first manufactured insulin pump was introduced in the 1970s and the first insulin pens in 1985; since then, many improvements have been made to both devices. The advantages of pens over syringes have been confirmed in numerous studies and include greater accuracy, ease of use, patient satisfaction, quality of life, and adherence. United States claims database analyses indicate that the improved adherence made possible by use of an insulin pen has the potential to reduce diabetes care costs when compared with using a vial and syringe. Features of certain advanced pump models include the ability to connect wirelessly to a blood glucose meter or to a subcutaneous interstitial glucose sensor for semicontinuous glucose-driven insulin rate adjustment. A new trend in the design of insulin pumps is the tubing-free patch pump that adheres directly to the skin. The low rate of insulin pen usage in the United States compared with European countries and the fact that many patients report that they are not offered the option of an insulin pen by their physician suggest that there is a need to increase patient and provider awareness of the currently available devices for insulin administration.
- 1 May 2010
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 4 (3) , 505-513
Open AccessEvolution of Diabetes Insulin Delivery Devices
The first manufactured insulin pump was introduced in the 1970s and the first insulin pens in 1985; since then, many improvements have been made to both devices. The advantages of pens over syringes have been confirmed in numerous studies and include greater accuracy, ease of use, patient satisfaction, quality of life, and adherence. United States claims database analyses indicate that the improved adherence made possible by use of an insulin pen has the potential to reduce diabetes care costs when compared with using a vial and syringe. Features of certain advanced pump models include the ability to connect wirelessly to a blood glucose meter or to a subcutaneous interstitial glucose sensor for semicontinuous glucose-driven insulin rate adjustment. A new trend in the design of insulin pumps is the tubing-free patch pump that adheres directly to the skin. The low rate of insulin pen usage in the United States compared with European countries and the fact that many patients report that they are not offered the option of an insulin pen by their physician suggest that there is a need to increase patient and provider awareness of the currently available devices for insulin administration.
- 1 February 2009
- Published by Springer Nature in Advances in Therapy
- Vol. 26 (2) , 194-207
Basal-bolus therapy with insulin detemir using the 303 algorithm in the US PREDICTIVE 303 trial
The aim of this study was to compare a simplified patient-driven algorithm (303 Algorithm) to physician-driven adjustments in a subset of 193 patients with type 2 diabetes from the PREDICTIVE 303 study who were using basal-bolus insulin therapy. PREDICTIVE 303 was a 26-week, randomized, phase 4 study, in which subjects were either instructed to adjust their insulin detemir dose every 3 days by ±3 units if mean fasting plasma glucose (FPG) values were above 110 mg/dL or below 80 mg/dL (303 Algorithm), or had physicians adjust the insulin detemir dose according to usual practice (Standard-of-care). Patients in both groups achieved similar reductions in glycated hemoglobin (−0.2% and −0.3% for 303 Algorithm and Standard-of care groups, respectively; between groups P=0.60). 303 Algorithm group patients achieved a greater reduction in FPG (−21.3 mg/dL vs. 0.2 mg/dL; between groups P=0.03). Both 303 Algorithm and Standard-of care groups experienced a similar rate of overall hypoglycemia, and similar weight reduction (−1.7 kg and −0.4 kg, respectively; between groups P=0.07). Over 82% of patients in both groups used insulin detemir once daily. Adjustments of a once-daily detemir dose by patients using the 303 Algorithm in a basalbolus setting is equally effective in improving glycemic control in patients with type 2 diabetes compared with physician-directed basal dose adjustments.
- 1 February 2009
- Published by Springer Nature in Advances in Therapy
- Vol. 26 (2) , 194-207
Basal-bolus therapy with insulin detemir using the 303 algorithm in the US PREDICTIVE 303 trial
The aim of this study was to compare a simplified patient-driven algorithm (303 Algorithm) to physician-driven adjustments in a subset of 193 patients with type 2 diabetes from the PREDICTIVE 303 study who were using basal-bolus insulin therapy. PREDICTIVE 303 was a 26-week, randomized, phase 4 study, in which subjects were either instructed to adjust their insulin detemir dose every 3 days by ±3 units if mean fasting plasma glucose (FPG) values were above 110 mg/dL or below 80 mg/dL (303 Algorithm), or had physicians adjust the insulin detemir dose according to usual practice (Standard-of-care). Patients in both groups achieved similar reductions in glycated hemoglobin (−0.2% and −0.3% for 303 Algorithm and Standard-of care groups, respectively; between groups P=0.60). 303 Algorithm group patients achieved a greater reduction in FPG (−21.3 mg/dL vs. 0.2 mg/dL; between groups P=0.03). Both 303 Algorithm and Standard-of care groups experienced a similar rate of overall hypoglycemia, and similar weight reduction (−1.7 kg and −0.4 kg, respectively; between groups P=0.07). Over 82% of patients in both groups used insulin detemir once daily. Adjustments of a once-daily detemir dose by patients using the 303 Algorithm in a basalbolus setting is equally effective in improving glycemic control in patients with type 2 diabetes compared with physician-directed basal dose adjustments.
- Open Access
- 1 March 2008
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 2 (2) , 311-315
Inhaled Insulin: Promises and Concerns
Since the introduction of Pfizer Exubera® in the early 1990s, a number of other inhaled insulin solutions have been developed. This article provides an overview of inhaled insulin systems developed by Pfizer, Novo Nordisk, MannKind, and Lilly, three of which are currently in phase 3 trials. The strengths and weaknesses of each product, as well as the general technologies (liquid vs dry powder), are evaluated. Results of clinical studies conducted by Pfizer and corroborated by other studies are summarized. Although inhaled insulin promises much, a greater body of controlled studies is necessary to draw firm conclusions about its safety and
- 1 March 2008
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 2 (2) , 311-315
Open AccessInhaled Insulin: Promises and Concerns
Since the introduction of Pfizer Exubera® in the early 1990s, a number of other inhaled insulin solutions have been developed. This article provides an overview of inhaled insulin systems developed by Pfizer, Novo Nordisk, MannKind, and Lilly, three of which are currently in phase 3 trials. The strengths and weaknesses of each product, as well as the general technologies (liquid vs dry powder), are evaluated. Results of clinical studies conducted by Pfizer and corroborated by other studies are summarized. Although inhaled insulin promises much, a greater body of controlled studies is necessary to draw firm conclusions about its safety and
- 14 November 2007
- Published by Informa Healthcare in Current Medical Research and Opinion
- Vol. 24 (1) , 11-20
Improving glycemic control with insulin detemir using the 303 Algorithm in insulin naïve patients with type 2 diabetes: a subgroup analysis of the US PREDICTIVE 303 study
PREDICTIVE 303 was a 26-week, prospective, randomized, open-label, multi-center study in patients with type 2 diabetes that investigated whether patient-driven adjustments of insulin detemir doses using the 303 Algorithm achieved similar glycemic control compared to standard-of-care, physician-driven adjustments in doses. This post hoc sub-analysis evaluates insulin naïve patients on oral anti-diabetic drugs (OADs) who were directed to start on once-daily insulin detemir as add-on therapy to any other glucose-lowering regimens. Patients in the 303 Algorithm group were instructed to adjust their detemir dose every 3 days based on mean fasting plasma glucose (FPG) values using a simple algorithm: mean FPG < 80 mg/dL, reduce dose by 3 units; between 80-110mg/dL, no change; > 110mg/dL, increase by 3 units. Physicians adjusted the detemir dose for patients in the Standard-of-care group according to their usual practice. No control insulin was used for comparison to insulin detemir. Reductions in glycosylated hemoglobin (HbA(1c)) from baseline were similar between those patients in the 303 Algorithm and Standard-of-care groups (-1.1 and -1.0%, respectively; between group p = 0.0933); patients in the 303 Algorithm group achieved a greater reduction in FPG. Patients in both groups experienced a similar, low rate of hypoglycemia. Over 95% and 92% of patients, respectively, used detemir once daily. These data indicate that patients with type 2 diabetes naïve to insulin can effectively implement the 303 Algorithm to initiate and adjust a once-daily dose of insulin detemir to achieve improvements in glycemic control.
- 14 November 2007
- Published by Informa Healthcare in Current Medical Research and Opinion
- Vol. 24 (1) , 11-20
Improving glycemic control with insulin detemir using the 303 Algorithm in insulin naïve patients with type 2 diabetes: a subgroup analysis of the US PREDICTIVE 303 study
PREDICTIVE 303 was a 26-week, prospective, randomized, open-label, multi-center study in patients with type 2 diabetes that investigated whether patient-driven adjustments of insulin detemir doses using the 303 Algorithm achieved similar glycemic control compared to standard-of-care, physician-driven adjustments in doses. This post hoc sub-analysis evaluates insulin naïve patients on oral anti-diabetic drugs (OADs) who were directed to start on once-daily insulin detemir as add-on therapy to any other glucose-lowering regimens. Patients in the 303 Algorithm group were instructed to adjust their detemir dose every 3 days based on mean fasting plasma glucose (FPG) values using a simple algorithm: mean FPG < 80 mg/dL, reduce dose by 3 units; between 80-110mg/dL, no change; > 110mg/dL, increase by 3 units. Physicians adjusted the detemir dose for patients in the Standard-of-care group according to their usual practice. No control insulin was used for comparison to insulin detemir. Reductions in glycosylated hemoglobin (HbA(1c)) from baseline were similar between those patients in the 303 Algorithm and Standard-of-care groups (-1.1 and -1.0%, respectively; between group p = 0.0933); patients in the 303 Algorithm group achieved a greater reduction in FPG. Patients in both groups experienced a similar, low rate of hypoglycemia. Over 95% and 92% of patients, respectively, used detemir once daily. These data indicate that patients with type 2 diabetes naïve to insulin can effectively implement the 303 Algorithm to initiate and adjust a once-daily dose of insulin detemir to achieve improvements in glycemic control.
- 1 January 2003
- Published by Taylor & Francis in Expert Opinion on Pharmacotherapy
- Vol. 4 (8) , 1373-1377
Inhaled insulin for the treatment of diabetes: projects and devices
A non-invasive alternative to insulin injections would represent a major improvement for Type 1 and 2 insulin-treated patients. The lung is the only route which allows bio-availability of insulin, approaching 10% without absorption enhancers. However, the reproducibility of the plasma response to the pulmonary insulin is similar to subcutaneous insulin analogues, that is to say, relatively poor. In the Exubera Project, the device is a dry powder inhaler. The insulin powder (Aventis) is packaged into a single dose blister containing 1 or 3 mg; the 1 mg blister corresponding to ∼ 3 U of insulin. Phase II studies have shown similar efficacy than regular insulin. Data are available on 328 Type 1 and 309 Type 2 patients after 6 months of Phase III trials. The inhaled insulin group developed increased insulin antibodies. A total of 25% of the patients experienced cough after inhalation. The number of overall and severe hypoglycaemic episodes were similar in the two groups. Pulmonary function tests remained stable and normal except for minor reductions of carbon monoxide diffusion capacity. The AERx IDMS system is a microprocessor-controlled, aqeous mist inhaler. The insulin (regular 100 U/ml, Novo Nordisk) is delivered by 1 U increments. The clinical experience reported with this system so far is limited to 107 Type 2 insulin-treated patients. The results are similar to those obtained in the Exubera trials. In the Alkermes project, large, porous, regular insulin of low-mass density have been developed by the Advanced Inhalation Project. Results from human studies in normal subjects show similar pharmacokinetics as the two other devices above. Other projects seem less advanced than the projects cited above e.g., Aerodos and Oralin. Current clinical experience with inhaled insulin seems promising. It represents currently the only viable non-invasive alternative to insulin injections. However, long-term local tolerance of the pulmonary tissue is a crucial issue.
- 1 January 2003
- Published by Taylor & Francis in Expert Opinion on Pharmacotherapy
- Vol. 4 (8) , 1373-1377
Inhaled insulin for the treatment of diabetes: projects and devices
A non-invasive alternative to insulin injections would represent a major improvement for Type 1 and 2 insulin-treated patients. The lung is the only route which allows bio-availability of insulin, approaching 10% without absorption enhancers. However, the reproducibility of the plasma response to the pulmonary insulin is similar to subcutaneous insulin analogues, that is to say, relatively poor. In the Exubera Project, the device is a dry powder inhaler. The insulin powder (Aventis) is packaged into a single dose blister containing 1 or 3 mg; the 1 mg blister corresponding to ∼ 3 U of insulin. Phase II studies have shown similar efficacy than regular insulin. Data are available on 328 Type 1 and 309 Type 2 patients after 6 months of Phase III trials. The inhaled insulin group developed increased insulin antibodies. A total of 25% of the patients experienced cough after inhalation. The number of overall and severe hypoglycaemic episodes were similar in the two groups. Pulmonary function tests remained stable and normal except for minor reductions of carbon monoxide diffusion capacity. The AERx IDMS system is a microprocessor-controlled, aqeous mist inhaler. The insulin (regular 100 U/ml, Novo Nordisk) is delivered by 1 U increments. The clinical experience reported with this system so far is limited to 107 Type 2 insulin-treated patients. The results are similar to those obtained in the Exubera trials. In the Alkermes project, large, porous, regular insulin of low-mass density have been developed by the Advanced Inhalation Project. Results from human studies in normal subjects show similar pharmacokinetics as the two other devices above. Other projects seem less advanced than the projects cited above e.g., Aerodos and Oralin. Current clinical experience with inhaled insulin seems promising. It represents currently the only viable non-invasive alternative to insulin injections. However, long-term local tolerance of the pulmonary tissue is a crucial issue.