Ann N. Tescher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ann N. Tescher has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Aaron B. Rindflesch
Program in Physical Therapy, College of Medicine and Science, Mayo Clinic, Rochester, MN 55905, USA
1 shared publication - Amy Hester
HD Nursing, Benton, AR
1 shared publication Ann H.
Ann H. Tescher, PhD, RN, CCRN, CCNS, FCCM, is a clinical nurse specialist at the Surgical/Trauma Intensive Care Unit of the Mayo Clinic at Rochester, Minnesota. Dr Tescher is a reviewer of manuscripts for Dimensions of Critical Care Nursing
1 shared publicationAnne G. Miers
1 shared publication- Barbara Delmore
Center for Innovations in the Advancement of Care (CIAC), NYU Langone Health, Hansjӧrg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY
1 shared publication Beth A Sievers
Skin Population, Department of Nursing, Mayo Clinic, Rochester, MN
1 shared publication
Latest Publications
- Open Access
- 14 October 2025
- Published by Wolters Kluwer Health in Advances in Skin & Wound Care
- Vol. 38 (10) , E128-E137
State-of-the-Art Review of Current Technology in Pressure Injury Early Detection
OBJECTIVE: To review currently available devices on pressure injury (PI) early detection, summarize challenges and opportunities to clinical implementation, and propose evaluation standards for device categories. DATA SOURCES: PubMed and US Food and Drug Administration (FDA) databases. STUDY SELECTION: Published in English from peer-reviewed journals with full text available. Excluded if opinion statements, lack of empirical data, or unrelated to project’s objective. DATA EXTRACTION: For both clinical device and research equipment: measurement mechanisms, measurement types, outcome/output, FDA classification, and indications for use. Addition data were extracted for clinical devices: instruction for use, end user, order requirement, and billable code. DATA SYNTHESIS: The 4 clinical devices are ultrasound, long-wave infrared thermography, subepidermal moisture assessment, and nearinfrared spectroscopy. The 3 research devices are laser Doppler flowmetry, laser speckle contrast imaging, and colorimetry. CONCLUSIONS: The measurement mechanisms of all devices are unique and different from each other. One commonality is that they could measure the nonvisual signs of PI (eg, inflammation, edema, ischemia, and hypoxia) except colorimeter. Some clinical devices are promising to assist with early identification of PIs, especially in individuals with dark skin tones. Currently, there is no reimbursement available for early detection of PI. Current evidence did not support replacing the standard skin assessment of visual inspection and palpation with the devices reviewed, rather using validated devices to augment the current practice standard. This is especially recommended for individuals identified as high risk for a PI on admission to a facility.
- 14 October 2025
- Published by Wolters Kluwer Health in Advances in Skin & Wound Care
- Vol. 38 (10) , E128-E137
Open AccessState-of-the-Art Review of Current Technology in Pressure Injury Early Detection
OBJECTIVE: To review currently available devices on pressure injury (PI) early detection, summarize challenges and opportunities to clinical implementation, and propose evaluation standards for device categories. DATA SOURCES: PubMed and US Food and Drug Administration (FDA) databases. STUDY SELECTION: Published in English from peer-reviewed journals with full text available. Excluded if opinion statements, lack of empirical data, or unrelated to project’s objective. DATA EXTRACTION: For both clinical device and research equipment: measurement mechanisms, measurement types, outcome/output, FDA classification, and indications for use. Addition data were extracted for clinical devices: instruction for use, end user, order requirement, and billable code. DATA SYNTHESIS: The 4 clinical devices are ultrasound, long-wave infrared thermography, subepidermal moisture assessment, and nearinfrared spectroscopy. The 3 research devices are laser Doppler flowmetry, laser speckle contrast imaging, and colorimetry. CONCLUSIONS: The measurement mechanisms of all devices are unique and different from each other. One commonality is that they could measure the nonvisual signs of PI (eg, inflammation, edema, ischemia, and hypoxia) except colorimeter. Some clinical devices are promising to assist with early identification of PIs, especially in individuals with dark skin tones. Currently, there is no reimbursement available for early detection of PI. Current evidence did not support replacing the standard skin assessment of visual inspection and palpation with the devices reviewed, rather using validated devices to augment the current practice standard. This is especially recommended for individuals identified as high risk for a PI on admission to a facility.
- 22 August 2023
- Published by Wolters Kluwer Health in Advances in Skin & Wound Care
- Vol. 37 (3) , 155-161
Use of a Shear Reduction Surface for Prehospital Transport: A Randomized Crossover Study
OBJECTIVE: To compare the effectiveness of an antishear mattress overlay (ASMO) with a standard ambulance stretcher surface in reducing pressure and shear and increasing patient comfort. METHODS: In this randomized, crossover design, adults in three body mass index categories served as their own controls. Pressure/shear sensors were applied to the sacrum, ischial tuberosity, and heel. The stretcher was placed in sequential 0°, 15°, and 30° head-of-bed elevations with and without an ASMO. The ambulance traveled a closed course, achieving 30 mph, with five stops at each head-of-bed elevation. Participants rated discomfort after each series of five runs. RESULTS: Thirty individuals participated. Each participant had 30 runs (15 with an ASMO, 15 without), for a total of 900 trial runs. The peak-to-peak shear difference between support surfaces was −0.03 N, indicating that after adjustment for elevation, sensor location, and body mass index, peak shear levels at baseline (starting pause) were 0.03 N lower for the ASMO than for the standard surface (P = .02). The peak-to-peak pressure difference between surfaces was −0.16 mm Hg, indicating that prerun peak-to-peak pressure was 0.16 mm Hg lower with the ASMO versus standard surface (P = .002). The heel received the most pressure and shear. Discomfort score distributions differed between surfaces at 0° (P = .004) and 30° (P = .01); the overall score across all elevations was significantly higher with the standard surface than with the ASMO (P = .046). CONCLUSIONS: The ASMO reduced shear, pressure, and discomfort. During transport, the ambulance team should provide additional heel offloading.
- 22 August 2023
- Published by Wolters Kluwer Health in Advances in Skin & Wound Care
- Vol. 37 (3) , 155-161
Use of a Shear Reduction Surface for Prehospital Transport: A Randomized Crossover Study
OBJECTIVE: To compare the effectiveness of an antishear mattress overlay (ASMO) with a standard ambulance stretcher surface in reducing pressure and shear and increasing patient comfort. METHODS: In this randomized, crossover design, adults in three body mass index categories served as their own controls. Pressure/shear sensors were applied to the sacrum, ischial tuberosity, and heel. The stretcher was placed in sequential 0°, 15°, and 30° head-of-bed elevations with and without an ASMO. The ambulance traveled a closed course, achieving 30 mph, with five stops at each head-of-bed elevation. Participants rated discomfort after each series of five runs. RESULTS: Thirty individuals participated. Each participant had 30 runs (15 with an ASMO, 15 without), for a total of 900 trial runs. The peak-to-peak shear difference between support surfaces was −0.03 N, indicating that after adjustment for elevation, sensor location, and body mass index, peak shear levels at baseline (starting pause) were 0.03 N lower for the ASMO than for the standard surface (P = .02). The peak-to-peak pressure difference between surfaces was −0.16 mm Hg, indicating that prerun peak-to-peak pressure was 0.16 mm Hg lower with the ASMO versus standard surface (P = .002). The heel received the most pressure and shear. Discomfort score distributions differed between surfaces at 0° (P = .004) and 30° (P = .01); the overall score across all elevations was significantly higher with the standard surface than with the ASMO (P = .046). CONCLUSIONS: The ASMO reduced shear, pressure, and discomfort. During transport, the ambulance team should provide additional heel offloading.
- 1 December 2022
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 31 (Sup12) , S4-S9
Perioperative pressure injury prevention: National Pressure Injury Advisory Panel root cause analysis toolkit 3.0
Objectives: Operating room-related pressure injuries (ORPI) are particularly challenging to examine for several reasons. Time in the OR is often a distinct event within the hospitalisation, and discovery of an ORPI may occur between several hours and up to 5 days postoperatively. The National Pressure Injury Advisory Panel (NPIAP) first developed a root cause analysis (RCA) toolkit in 2017 as a systematic strategy for investigating the root causes of facility-acquired pressure injury (PI). The purpose of this 2021 RCA toolkit update was to address an expanded investigation of medical device-related PIs (MDRPIs), both inside and outside the OR, as well as the specific PI prevention issues of the perioperative area. Methods: Clinicians have been using the 2017 toolkit as a basis for ongoing quality improvement tracking, since it provides more accurate information than data extractions from patient health records. A small working group consisting of NPIAP board and panel members developed investigative questions to identify the ORPI root causes and compliance with best practices for the entire perioperative experience. Results: Action items are linked to evidence-based recommendations from the NPIAP/European Pressure Ulcer Advisory Panel/Pan Pacific Pressure Injury Alliance 2019 International Guideline and the Association of PeriOperative Registered Nurses (AORN) Guidelines for Perioperative Practice. A multidisciplinary clinician guide was also developed to identify practice gaps and to compile the information into an action plan for staff education and/or process improvement. Conclusion: The updated NPIAP RCA toolkit provides mechanisms for investigating, compiling and trending data as a basis for data-driven quality improvement. Using the enhanced investigative tools, the root causes of both MDRPIs and ORPIs can be better understood to target efforts to reduce their occurrence.
- 1 December 2022
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 31 (Sup12) , S4-S9
Perioperative pressure injury prevention: National Pressure Injury Advisory Panel root cause analysis toolkit 3.0
Objectives: Operating room-related pressure injuries (ORPI) are particularly challenging to examine for several reasons. Time in the OR is often a distinct event within the hospitalisation, and discovery of an ORPI may occur between several hours and up to 5 days postoperatively. The National Pressure Injury Advisory Panel (NPIAP) first developed a root cause analysis (RCA) toolkit in 2017 as a systematic strategy for investigating the root causes of facility-acquired pressure injury (PI). The purpose of this 2021 RCA toolkit update was to address an expanded investigation of medical device-related PIs (MDRPIs), both inside and outside the OR, as well as the specific PI prevention issues of the perioperative area. Methods: Clinicians have been using the 2017 toolkit as a basis for ongoing quality improvement tracking, since it provides more accurate information than data extractions from patient health records. A small working group consisting of NPIAP board and panel members developed investigative questions to identify the ORPI root causes and compliance with best practices for the entire perioperative experience. Results: Action items are linked to evidence-based recommendations from the NPIAP/European Pressure Ulcer Advisory Panel/Pan Pacific Pressure Injury Alliance 2019 International Guideline and the Association of PeriOperative Registered Nurses (AORN) Guidelines for Perioperative Practice. A multidisciplinary clinician guide was also developed to identify practice gaps and to compile the information into an action plan for staff education and/or process improvement. Conclusion: The updated NPIAP RCA toolkit provides mechanisms for investigating, compiling and trending data as a basis for data-driven quality improvement. Using the enhanced investigative tools, the root causes of both MDRPIs and ORPIs can be better understood to target efforts to reduce their occurrence.
- 5 November 2018
- Published by HMP Communications, LLC in Wound Management & Prevention
- Vol. 64 (11) , 30-41
A Retrospective, Descriptive Analysis of Hospital-acquired Deep Tissue Injuries
Empirical Studies from Wound Management & Prevention.
- 5 November 2018
- Published by HMP Communications, LLC in Wound Management & Prevention
- Vol. 64 (11) , 30-41
A Retrospective, Descriptive Analysis of Hospital-acquired Deep Tissue Injuries
Empirical Studies from Wound Management & Prevention.
- 1 May 2012
- Published by Wolters Kluwer Health in Journal of Wound, Ostomy & Continence Nursing
- Vol. 39 (3) , 282-291
All At-Risk Patients Are Not Created Equal
To improve identification of risk factors for pressure ulcer development and enhance targeted interventions and prevention strategies. The records of 12,566 adult patients hospitalized in intensive or progressive care units within Mayo Clinic were analyzed. Inclusion criteria were Braden Scale of 18 or less during the hospitalization; exclusion criteria were preexisting pressure ulcer or length of stay less than 24 hours. This study is a retrospective cohort analysis of electronic medical record data from January 1, 2007, to December 31, 2007. Only iatrogenic stage 2 to 4 pressure ulcers were considered as incident events. Demographic and clinical data were extracted from the medical record, including total Braden Scale score and Braden subscale scores at hospital admission, length of stay, admission to the intensive care unit at the time of hospitalization, and presence of acute respiratory failure, acute renal failure, or diabetes. Time to event was calculated based on time from admission to pressure ulcer occurrence or to hospital discharge. Four hundred sixteen (3.3%) of patients developed a pressure ulcer during their hospitalizations. The Braden Scale score total by itself was found to be highly predictive of pressure ulcer development (P ≤ .0001, C = 0.71), as were all individual subscores. The friction/shear subscale had the greatest predictive power among Braden Scale scores (subscores and total score) (C = 0.83). The multivariate model after selection included 5 Braden Scale subscales, surgery, and acute respiratory failure (C = 0.91). The total Braden Scale score is predictive of pressure ulcer development but does not assist the clinician to develop an individualized targeted prevention plan. In contrast, the use of subscale scores can enhance prevention programs and resource utilization by focusing care on the risk factors specific to the individual patient.
- 1 May 2012
- Published by Wolters Kluwer Health in Journal of Wound, Ostomy & Continence Nursing
- Vol. 39 (3) , 282-291
All At-Risk Patients Are Not Created Equal
To improve identification of risk factors for pressure ulcer development and enhance targeted interventions and prevention strategies. The records of 12,566 adult patients hospitalized in intensive or progressive care units within Mayo Clinic were analyzed. Inclusion criteria were Braden Scale of 18 or less during the hospitalization; exclusion criteria were preexisting pressure ulcer or length of stay less than 24 hours. This study is a retrospective cohort analysis of electronic medical record data from January 1, 2007, to December 31, 2007. Only iatrogenic stage 2 to 4 pressure ulcers were considered as incident events. Demographic and clinical data were extracted from the medical record, including total Braden Scale score and Braden subscale scores at hospital admission, length of stay, admission to the intensive care unit at the time of hospitalization, and presence of acute respiratory failure, acute renal failure, or diabetes. Time to event was calculated based on time from admission to pressure ulcer occurrence or to hospital discharge. Four hundred sixteen (3.3%) of patients developed a pressure ulcer during their hospitalizations. The Braden Scale score total by itself was found to be highly predictive of pressure ulcer development (P ≤ .0001, C = 0.71), as were all individual subscores. The friction/shear subscale had the greatest predictive power among Braden Scale scores (subscores and total score) (C = 0.83). The multivariate model after selection included 5 Braden Scale subscales, surgery, and acute respiratory failure (C = 0.91). The total Braden Scale score is predictive of pressure ulcer development but does not assist the clinician to develop an individualized targeted prevention plan. In contrast, the use of subscale scores can enhance prevention programs and resource utilization by focusing care on the risk factors specific to the individual patient.
- 1 January 2012
- Published by Wolters Kluwer Health in Dimensions of Critical Care Nursing
- Vol. 31 (3) , 187
Book Review
- 1 January 2012
- Published by Wolters Kluwer Health in Dimensions of Critical Care Nursing
- Vol. 31 (3) , 187
Book Review
- 1 November 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 63 (5) , 1120-1126
Range-of-Motion Restriction and Craniofacial Tissue-Interface Pressure From Four Cervical Collars
Occipital pressure ulcers are well-known complications for trauma patients wearing cervical collars. We assessed the effects of four commercial cervical collars (Aspen, Philadelphia, Miami J, and Miami J with Occian back [Miami J/Occian]) on cervical range of motion (CROM) and mandibular and occipital tissue-interface pressure (TIP). Forty-eight healthy volunteers (24 men, 24 women; mean age, 38.9 years ± 10.5 years) were stratified by body mass index. CROM was measured in the seated position without and with collars. Sagittal, coronal, and rotatory CROM was measured with a goniometer. Occipital and mandibular pressures were mapped with subjects in upright and supine positions. All collars significantly restricted CROM in all planes (p < 0.001). The Philadelphia and standard Miami J collars were the most restrictive. The Aspen collar was the least restrictive for flexion and rotation. The Miami J/Occian back was the least restrictive for extension and lateral flexion. For supine measurements, Miami J and Miami J/Occian back had the lowest mean TIP, whereas Aspen and Philadelphia collars had the greatest (p < 0.001). For upright measurements, the Miami J/Occian back produced the smallest mean TIPs; the other collars, ranked by ascending TIP, were Philadelphia, Miami J, and Aspen (p < 0.001). Philadelphia and Miami J collars had significant collar-body mass index interaction effects on supine occiput mean pressure (p = 0.04). Miami J and Philadelphia collars restricted CROM to the greatest extent. Miami J and Miami J/Occian back had the lowest levels of mandibular and occipital pressure; these collars may markedly reduce the risk of occipital pressure ulcers without compromising immobilization.
- 1 November 2007
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 63 (5) , 1120-1126
Range-of-Motion Restriction and Craniofacial Tissue-Interface Pressure From Four Cervical Collars
Occipital pressure ulcers are well-known complications for trauma patients wearing cervical collars. We assessed the effects of four commercial cervical collars (Aspen, Philadelphia, Miami J, and Miami J with Occian back [Miami J/Occian]) on cervical range of motion (CROM) and mandibular and occipital tissue-interface pressure (TIP). Forty-eight healthy volunteers (24 men, 24 women; mean age, 38.9 years ± 10.5 years) were stratified by body mass index. CROM was measured in the seated position without and with collars. Sagittal, coronal, and rotatory CROM was measured with a goniometer. Occipital and mandibular pressures were mapped with subjects in upright and supine positions. All collars significantly restricted CROM in all planes (p < 0.001). The Philadelphia and standard Miami J collars were the most restrictive. The Aspen collar was the least restrictive for flexion and rotation. The Miami J/Occian back was the least restrictive for extension and lateral flexion. For supine measurements, Miami J and Miami J/Occian back had the lowest mean TIP, whereas Aspen and Philadelphia collars had the greatest (p < 0.001). For upright measurements, the Miami J/Occian back produced the smallest mean TIPs; the other collars, ranked by ascending TIP, were Philadelphia, Miami J, and Aspen (p < 0.001). Philadelphia and Miami J collars had significant collar-body mass index interaction effects on supine occiput mean pressure (p = 0.04). Miami J and Philadelphia collars restricted CROM to the greatest extent. Miami J and Miami J/Occian back had the lowest levels of mandibular and occipital pressure; these collars may markedly reduce the risk of occipital pressure ulcers without compromising immobilization.
- Open Access
- 29 August 2007
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 7 (1) , 14
Comparison of a nurse initiated insulin infusion protocol for intensive insulin therapy between adult surgical trauma, medical and coronary care intensive care patients
Sustained hyperglycemia is a known risk factor for adverse outcomes in critically ill patients. The specific aim was to determine if a nurse initiated insulin infusion protocol (IIP) was effective in maintaining blood glucose values (BG) within a target goal of 100–150 mg/dL across different intensive care units (ICUs) and to describe glycemic control during the 48 hours after protocol discontinuation. A descriptive, retrospective review of 366 patients having 28,192 blood glucose values in three intensive care units, Surgical Trauma Intensive Care Unit (STICU), Medical (MICU) and Coronary Care Unit (CCU) in a quaternary care hospital was conducted. Patients were > 15 years of age, admitted to STICU (n = 162), MICU (n = 110) or CCU (n = 94) over 8 months; October 2003-June 2004 and who had an initial blood glucose level > 150 mg/dL. We summarized the effectiveness and safety of a nurse initiated IIP, and compared these endpoints among STICU, MICU and CCU patients. The median blood glucose values (mg/dL) at initiation of insulin infusion protocol were lower in STICU (188; IQR, 162–217) than in MICU, (201; IQR, 170–268) and CCU (227; IQR, 178–313); p < 0.0001. Mean time to achieving a target glucose level (100–150 mg/dL) was similar between the three units: 4.6 hours in STICU, 4.7 hours in MICU and 4.9 hours in CCU (p = 0.27). Hypoglycemia (BG < 60 mg/dL) occurred in 7% of STICU, 5% of MICU, and 5% of CCU patients (p = 0.85). Protocol violations were uncommon in all three ICUs. Mean blood glucose 48 hours following IIP discontinuation was significantly different for each population: 142 mg/dL in STICU, 167 mg/dL in MICU, and 160 mg/dL in CCU (p < 0.0001). The safety and effectiveness of nurse initiated IIP was similar across different ICUs in our hospital. Marked variability in glucose control after the protocol discontinuation suggests the need for further research regarding glucose control in patients transitioning out of the ICU.
- 29 August 2007
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 7 (1) , 14
Open AccessComparison of a nurse initiated insulin infusion protocol for intensive insulin therapy between adult surgical trauma, medical and coronary care intensive care patients
Sustained hyperglycemia is a known risk factor for adverse outcomes in critically ill patients. The specific aim was to determine if a nurse initiated insulin infusion protocol (IIP) was effective in maintaining blood glucose values (BG) within a target goal of 100–150 mg/dL across different intensive care units (ICUs) and to describe glycemic control during the 48 hours after protocol discontinuation. A descriptive, retrospective review of 366 patients having 28,192 blood glucose values in three intensive care units, Surgical Trauma Intensive Care Unit (STICU), Medical (MICU) and Coronary Care Unit (CCU) in a quaternary care hospital was conducted. Patients were > 15 years of age, admitted to STICU (n = 162), MICU (n = 110) or CCU (n = 94) over 8 months; October 2003-June 2004 and who had an initial blood glucose level > 150 mg/dL. We summarized the effectiveness and safety of a nurse initiated IIP, and compared these endpoints among STICU, MICU and CCU patients. The median blood glucose values (mg/dL) at initiation of insulin infusion protocol were lower in STICU (188; IQR, 162–217) than in MICU, (201; IQR, 170–268) and CCU (227; IQR, 178–313); p < 0.0001. Mean time to achieving a target glucose level (100–150 mg/dL) was similar between the three units: 4.6 hours in STICU, 4.7 hours in MICU and 4.9 hours in CCU (p = 0.27). Hypoglycemia (BG < 60 mg/dL) occurred in 7% of STICU, 5% of MICU, and 5% of CCU patients (p = 0.85). Protocol violations were uncommon in all three ICUs. Mean blood glucose 48 hours following IIP discontinuation was significantly different for each population: 142 mg/dL in STICU, 167 mg/dL in MICU, and 160 mg/dL in CCU (p < 0.0001). The safety and effectiveness of nurse initiated IIP was similar across different ICUs in our hospital. Marked variability in glucose control after the protocol discontinuation suggests the need for further research regarding glucose control in patients transitioning out of the ICU.