S. Amano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. Amano has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- B. Merecka
Odournet UK Ltd, 5, St. Margaret's Street, Bradford on Avon, Wiltshire BA15 1DA, UK
1 shared publication H. Ueno
1 shared publication- Hiroyuki Ueno
Tokyo Metropolitan Research Institute for Environmental Protection, 1-7-5 Shinsuna, Koto-ku, Tokyo 136-0075, Japan
1 shared publication - J. Kośmider
Szczecin University of Technology, Piastów Avenue 42, 71-065 Szczecin, Poland
1 shared publication K. Kakiuchi
1 shared publicationK. Yamaguchi
1 shared publication
Latest Publications
- 1 April 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 59 (7) , 1339-1342
Difference in the odor concentrations measured by the triangle odor bag method and dynamic olfactometry
‘The triangle odor bag method’, which has been adopted for the offensive odor control law in Japan, and the dynamic olfactometry defined by EN 13725 have been compared. The odor concentration measured by the triangle odor bag method tends to be higher than that of the dynamic olfactometry in the forced choice mode, while well agreed in the Yes/No mode olfactometry when the panel is the same. The difference can be minimized by applying the panel selection criterion of EN13725 to the triangle odor bag method. The European panel selection test is useful to negate the difference in the measurement equipments although the criteria seem to be strict considering the individual threshold data of n-butanol.
- 1 April 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 59 (7) , 1339-1342
Difference in the odor concentrations measured by the triangle odor bag method and dynamic olfactometry
‘The triangle odor bag method’, which has been adopted for the offensive odor control law in Japan, and the dynamic olfactometry defined by EN 13725 have been compared. The odor concentration measured by the triangle odor bag method tends to be higher than that of the dynamic olfactometry in the forced choice mode, while well agreed in the Yes/No mode olfactometry when the panel is the same. The difference can be minimized by applying the panel selection criterion of EN13725 to the triangle odor bag method. The European panel selection test is useful to negate the difference in the measurement equipments although the criteria seem to be strict considering the individual threshold data of n-butanol.
- 1 March 1995
- Published by EDP Sciences in Revue de Métallurgie
- Vol. 92 (3) , 351-360
Technology of high-rate pulverized coal injection into blast furnace
Based on the results obtained from off-line model experiments and actual furnace tests, a high-rate pulverized coal injection operation was carried out at Kimitsu No. 3 blast furnace of Nippon Steel Corporation. A technology to achieve a stable blast furnace operation at the PCI rate of 190 kg/t has been established. For a stable operation at PCI rates greater than 200 kg/t and coke rates below 300 kg/t, the reduction-melting behaviour of ore at the lower part of the furnace has to be improved.
- 1 March 1995
- Published by EDP Sciences in Revue de Métallurgie
- Vol. 92 (3) , 351-360
Technology of high-rate pulverized coal injection into blast furnace
Based on the results obtained from off-line model experiments and actual furnace tests, a high-rate pulverized coal injection operation was carried out at Kimitsu No. 3 blast furnace of Nippon Steel Corporation. A technology to achieve a stable blast furnace operation at the PCI rate of 190 kg/t has been established. For a stable operation at PCI rates greater than 200 kg/t and coke rates below 300 kg/t, the reduction-melting behaviour of ore at the lower part of the furnace has to be improved.