HEHarmen B. Ettema

Harmen B. Ettema

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harmen B. Ettema has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    20 years of blood management and VTE prevention in orthopedic surgery in the Netherlands – a nationwide survey

    by Ruben Y. Kok, Joost-Jelle T. M. Gerritsen, Cees C. P. M. Verheyen, Banne Németh, Harmen B. Ettema

    Introduction: Advances in arthroplasty care have progressively improved patient outcomes, including reduced bleeding and venous thromboembolism rates. Consequently, blood-saving measures applied pre-, peri- and postoperatively as well as thromboprophylaxis regimens have evolved over time. To evaluate these developments, we conducted a 2023 follow-up to the national surveys from 2002, 2007 and 2012, examining current blood-saving strategies and thromboprophylaxis use in The Netherlands. Materials and methods: In 2023, a questionnaire designed to match the previous surveys was distributed to all orthopedic departments in the Netherlands. The collected data were summarized and compared with previous findings. Results: Responses were received from 61% of the Dutch orthopedic departments. Blood-saving practices have shifted significantly toward the use of tranexamic acid, accompanied by a decline in other measures. In particular, the use of drains, blood transfusions, and erythropoietin supplementation has decreased substantially. Thromboprophylaxis protocols showed fewer changes, although the average duration of prophylaxis has shortened, with low-molecular-weight heparin remaining the most commonly used anticoagulant. Conclusions: Advances in surgical techniques and postoperative care around arthroplasty appear to have reduced concerns about perioperative blood loss to a level where the use of tranexamic acid alone is considered sufficient to control blood loss, rendering many previously popular perioperative blood-saving measures redundant. In contrast, despite a decline in thrombotic complications associated with the introduction of fast-track surgery, thromboprophylaxis protocols have remained largely unchanged. These findings highlight the opportunity to further balance the risks of bleeding and thrombosis following arthroplasty.

  • Open Access

    Ten-year results of a prospective cohort of large-head metal-on-metal total hip arthroplasty

    by Christiaan P. van Lingen, Harmen B. Ettema, Bart H. Bosker, Cees C. P. M. Verheyen

    Aims: Large-diameter metal-on-metal (MoM) total hip arthroplasty (THA) has demonstrated unexpected high failure rates and pseudotumour formation. The purpose of this prospective cohort study is to report ten-year results in order to establish revision rate, prevalence of pseudotumour formation, and relation with whole blood cobalt levels. Methods: All patients were recalled according to the guidelines of the Dutch Orthopaedic Association. They underwent clinical and radiographical assessments (radiograph and CT scan) of the hip prosthesis and whole blood cobalt ion measurements. Overall, 94 patients (95 hips) fulfilled our requirements for a minimum ten-year follow-up. Results: Mean follow-up was 10.9 years (10 to 12), with a cumulative survival rate of 82.4%. Reason for revision was predominantly pseudotumour formation (68%), apart from loosening, pain, infection, and osteolysis. The prevalence of pseudotumour formation around the prostheses was 41%, while our previous report of this cohort (with a mean follow-up of 3.6 years) revealed a 39% prevalence. The ten-year revision-free survival with pseudotumour was 66.7% and without pseudotumour 92.4% (p < 0.05). There was poor discriminatory ability for cobalt for pseudotumour formation. Conclusion: This prospective study reports a minimum ten-year follow-up of large-head MoM THA. Revision rates are high, with the main reason being the sequelae of pseudotumour formation, which were rarely observed after five years of implantation. Blood ion measurements show limited discriminatory capacity in diagnosing pseudotumour formation. Our results evidence that an early comprehensive follow-up strategy is essential for MoM THA to promptly identify and manage early complications and revise on time. After ten years follow-up, we do not recommend continuing routine CT scanning or whole cobalt blood measurements, but instead enrolling these patients in routine follow-up protocols for THA. Cite this article: Bone Jt Open 2022;3(1):61–67.


  • Open Access

    Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    by Martijn F. Boomsma, Niek Warringa, Mireille A. Edens, Dirk Mueller, Harmen B. Ettema, Cees C. P. M. Verheyen, Mario Maas

    Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose due to different metal artefacts. The O-MAR algorithm deploys an iterative loop where the metal sinogram is identified, extracted, and subsequently serves as a mask to correct the measured sinogram. Main goal of this study is to quantify the ability of the O-MAR technique to correct deviation in medullary bone attenuation caused by streak artefacts from the large-head MoM THA embedded in a phantom. Secondary goal is to evaluate the influence of O-MAR on CNR. The phantom was designed as a Perspex box (PMMA) containing water and a supplementary MOM THA surrounded by Perspex columns comprising calibrated calcium pellets. Each column contains 200 mg of hydroxyapatite/calcium carbonate to simulate healthy bone tissue. Scans were obtained with and without a MoM THA at different dose levels. Different reconstructions were made with filter A, iDose4 level 5 and with and without O-MAR. The scans without the prosthesis were used as the baseline. Information about the attenuation in Hounsfield units, image noise in standard deviation within the ROI’s were extracted and the CNR was calculated. Pellet L0 and R0 (proximal of the MoM THA) were defined as reference, lacking any disturbance by metal artefacts; L5, L6 and L8 were respectively visually categorized as ‘light’ ‘medium’ and ‘heavy disturbance’. Significant improvements in attenuation deviation caused by metal artefact were 43, 68 and 32 %, for respectively pellet L5, L6 and L8 (p < 0.001). Significant CNR improvements were present for L5 and L6 and were respectively 72 and 52 % (p < 0.001). O-MAR showed no improvement on CNR for L8. This phantom study significantly increases image quality by the use of O-MAR in the presence of metal artefacts by significantly reducing metal artefacts subsequently and increasing CNR on a 64 slice CT system in light and medium disturbance of the image.


  • CT-based quantification of bone stock in large head metal-on-metal unilateral total hip replacements

    by Martijn F. Boomsma, Inge Slouwerhof, Christiaan van Lingen, Dean F.M. Pakvis, Jorn A. van Dalen, Mireille A. Edens, Harmen B. Ettema, Cees C.P.M. Verheyen, Mario Maas


  • Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips

    by B. H. Bosker, H. B. Ettema, M. van Rossum, M. F. Boomsma, B. J. Kollen, M. Maas, C. C. P. M. Verheyen

    The incidence and natural course of pseudotumors in metal-on-metal total hip arthroplasties is largely unknown. The objective of this study was to identify the true incidence and risk factors of pseudotumor formation in large head metal-on-metal total hip arthroplasties. Incidence, time course and risk factors for pseudotumor formation were analysed after large femoral head MoM-THA. We defined a pseudotumor as a (semi-)solid or cystic peri-prosthetic soft-tissue mass with a diameter ≥2 cm that could not be attributed to infection, malignancy, bursa or scar tissue. All patients treated in our clinic with MoM-THA’s were contacted. CT scan, metal ions and X-rays were obtained. Symptoms were recorded. After median follow-up of 3 years, 706 hips were screened in 626 patients. There were 228 pseudotumors (32.3 %) in 219 patients (35.0 %). Pseudotumor formation significantly increased after prolonged follow-up. Seventy-six hips (10.8 %) were revised in 73 patients (11.7 %), independent risk factors were identified. Best cutoff point for cobalt and chromium was 4 μg/l (68 and 77 nmol/l). This study confirms a high incidence of pseudotumors, dramatically increasing after prolonged follow-up. Risk factors for pseudotumors are of limited importance. Pain was the strongest predictor for pseudotumor presence; cobalt chromium and swelling were considered poor predictors. Cross-sectional imaging is the main screening tool during follow-up.


  • The Relation Between Titanium Taper Corrosion and Cobalt-Chromium Bearing Wear in Large-Head Metal-on-Metal Total Hip Prostheses

    by F. Witt, B.H. Bosker, N.E. Bishop, H.B. Ettema, C.C.P.M. Verheyen, M.M. Morlock

    Background: Revision of hip implants due to adverse tissue reactions to metal debris has been associated with wear and corrosion of the metal-on-metal bearing articulation and the modular taper interface. Bearing articulation wear is increased in conditions of poor lubrication, which can also lead to high friction moments that may cause corrosion at the taper interface. This suggests that wear of the bearing and increased corrosion of the taper interface should occur simultaneously, which was investigated in this study. Methods: Forty-three large-diameter cobalt-chromium bearings of the same design, implanted with a titanium stem using a titanium adapter, were retrieved at revision at a single center. Retrievals were grouped according to visual inspection of the female taper surface of the adapter into slight and severe corrosion groups. Volume change of bearing and taper surfaces was assessed using a coordinate measurement machine. Serum ion concentrations were determined for forty-three patients, whereas tissue metal concentration was measured for twelve patients. Results: Severe taper corrosion was observed in 30% of the retrievals. Corrosion was observed either as material deposition or wear. The overall bearing wear rate was significantly higher in the group with severe taper corrosion than in the group with slight corrosion (7.2 ± 9.0 mm3/yr versus 3.1 ± 6.8 mm3/yr, respectively; p = 0.023) as were the serum cobalt (40.5 ± 44.9 μg/L versus 15.2 ± 23.9 μg/L, respectively; p = 0.024) and chromium ion concentrations (32.7 ± 32.7 μg/L versus 12.0 ± 15.1 μg/L, respectively; p = 0.019). Serum metal ion concentrations were more consistent indicators of wear than tissue metal concentrations. Conclusions: The increased bearing articulation wear and serum metal ion concentrations in cases with taper interface corrosion support the hypothesis that increased friction in the joint articulation is one of the factors responsible for simultaneous articulation and taper damage. However, independent taper or bearing damage was also observed, suggesting that other factors are involved in the process.


  • Open Access

    Excellent results with the cemented Lubinus SP II 130-mm femoral stem at 10 years of follow-up

    by Wybren Prins, Remco Meijer, Boudewijn J Kollen, Cees Cpm Verheyen, Harmen B Ettema

    The Lubinus SP II stem is well documented in both orthopedic registries and clinical studies. Worldwide, the most commonly used stem lengths are 150 mm and 170 mm. In 1995, the 130-mm stem was introduced, but no outcome data have been published. We assessed the long-term survival of the Lubinus SP II 130-mm stem in primary total hip arthroplasty. In a retrospective cohort study, we evaluated 829 patients with a Lubinus SP II primary total hip arthroplasty (932 hips). The hips were implanted between 1996 and 2001. The primary endpoint was revision for any reason. The mean follow-up period was 10 (5-15) years. Survival analysis showed an all-cause 10-year survival rate of the stem of 98.7% (95% CI: 99.7-97.7), and all-cause 10-year survival of the total hip arthroplasty was 98.3% (95% CI: 99.3-97.3). Excellent long-term results can be achieved with the cemented Lubinus SP II with the relatively short 130-mm stem. This stem has potential advantages over its 150-mm and 170-mm siblings such as bone preservation distal to the stem, better proximal filling around the prosthesis, and easier removal.


  • Death and venous thromboembolism after lower extremity amputation

    by M. C. Struijk‐Mulder, W. VAN Wijhe, Y. K. Sze, S. Knollema, C. C. Verheyen, H. R. Büller, W. M. Fritschy, H. B. Ettema


    • 26 January 2008
      • Vol. 152  (4) , 203-6

    [How many steps does a doctor take in the hospital? No difference between internists and general surgeons, but a relationship with age and BMI].

    by J H M Goosen, H B Ettema, B J Kollen, C C P M Verheyen

    To determine the number of steps taken during working days in the hospital by both internists and general surgeons and whether there is a difference between housemen, registrars and members of the staff. Comparative analysis. A validated pedometer was used to count the number of steps taken by housemen, registrars and staff members in the departments of internal medicine and general surgery. The 2 groups of doctors comprised 131 subjects from 13 training hospitals. Possible factors likely to affect the number of steps, such as age, sex, weight and height, were recorded. The average number of steps taken per day was 5325 (range: 1105-10,250) and the average number per hour was 548 (range: 143-1105), with an average working day of 9.8 hours and 8.4 measured days. When corrected for age, sex and hierarchic status, no significant difference was observed between surgeons and internists (p = 0.097). There were also no differences within the hierarchic structure after correction (p = 0.936). Age and BMI seemed to be the most important factors predicting the number of steps in this population. Each additional year of age corresponded with an average decrease of 5 steps per hour on the job (p = 0.001), while each point rise in BMI (+1 kg/m) coincided with an average decrease of 20 steps per hour (p = 0.001). After correcting for confounding factors, no differences were observed in the number of steps taken in the hospital by general surgeons and internists. There was also no difference between hierarchic levels. Age and BMI were the most important variables that predicted the number of steps taken per hour in this research population.


    • 15 September 2007
      • Vol. 151  (37) , 2061-3

    [Deep venous thrombosis in an amputation stump].

    by E C T Baars, H B Ettema, W M Fritschy

    A 34-year-old patient underwent a knee exarticulation amputation and developed symptoms of pain, redness and swelling of the stump in combination with a feeling of tightness in the chest. These symptoms were first attributed to muscle pain and exertion but further examination revealed deep venous thrombosis (DVT) of the stump and a pulmonary embolism for which he was treated with nadroparine and acenocoumarol. Shortly after treatment he could resume the use of the prosthesis. A DVT in the amputation stump is not frequently encountered, but is a serious complication that can, together with a pulmonary embolism, be life threatening. The literature mentions an incidence ranging from 0-12%. Physical examination is often not conclusive and further examination of the patient with duplex scanning is necessary, with a ventilation-perfusion scan if a pulmonary embolism is suspected. Patients with a lower extremity amputation have a higher risk of developing a DVT because of immobility and increased venous pooling in the residual limb. Symptoms of a red, swollen, warm and painful stump should trigger the physician to suspect a DVT.