MHMark A. Hill

Mark A. Hill

*This is an algorithmically generated author record based on publicly available information.

Mark A. Hill has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental techniques for studying bystander effects in vitro by high and low-LET ionising radiation

    by M. A. Hill, D. L. Stevens, M. Kadhim, M. Blake-James, A. J. Mill, D. T. Goodhead

    Ionising radiation can induce responses within non-exposed neighbouring (bystander) cells which potentially have important implications on the estimates of risk from low dose or low dose rate exposures of ionising radiations. A range of strategies have been developed for investigating bystander effects in vitro for both high-LET alpha particles or low-LET ultrasoft X rays using either partial shielding (grids, half-shields and slits) or by using a co-culture system where two physically separated populations of cells can be cultured together, allowing one population of cells to be irradiated while the second population remains unirradiated. The techniques described provide a useful tool to study bystander effects and complement microbeam studies. Studies using these systems show significant increases in the unirradiated bystander cells for various end points including the induction of chromosomal instability in haemopoetic stem cells and transformation in CGL1 cells.


  • The variation in biological effectiveness of X-rays and gamma rays with energy

    by M. A. Hill

    The ICRP has attributed the same relative risk for all low-LET (linear energy transfer) radiations, including X and gamma radiations of all energies. However, very low energy X-rays are expected to be more biologically effective, per unit absorbed dose, than high energy X-rays or gamma rays due to the production of lower energy secondary electrons, with a correspondingly higher LET. This increase in relative biological effectiveness (RBE) is also seen experimentally for a range of biological end-points, however, a wide range of RBE values have been reported. The assessment of risks is particularly important due to the use of low energy X-rays for mammography screening. A review of the published data on the variation in biological effectiveness with energy is presented here.


  • Relative Sensitivities of Repair-Deficient Mammalian Cells for Clonogenic Survival after α-Particle Irradiation

    by Mark A. Hill, M. Trent Herdman, David L. Stevens, Nigel J. Jones, John Thacker, Dudley T. Goodhead

    The clonogenic survival of cells of the radiation-sensitive hamster cell lines irs1, irs2, irs3 and xrs5, representing different DNA repair pathways, was compared to that of their parent lines after alpha-particle irradiation. Measurements of nuclear area were made to calculate the probability of surviving a single alpha-particle traversal, the average number of lethal lesions per track and per unit dose, along with the "intrinsic radiosensitivity" of these cells, allowing for the potential of multiple lethal lesions per traversal. For all cell lines studied, alpha particles were found to be more biologically effective per unit absorbed dose than X rays at inducing cell inactivation. The repair-deficient cells showed an enhanced sensitivity to alpha particles compared to their parent line, but the degree of enhancement was less than for X rays. The reduction in additional sensitivity for alpha-particle irradiation was shown not to be due predominantly to differences in cell geometry limiting the probability of a cell nucleus being traversed. The results suggest that both the nonhomologous end-joining pathway and to a lesser extent the homologous recombination repair pathway play a role in successful repair of alpha-particle-induced damage, although a large proportion of damage is not repaired by either pathway.


  • The use of CVD diamond to produce carbon K ultrasoft x-rays

    by M A Hill

    Carbon K ultrasoft x-rays (278 eV) interact with biological material producing random, isolated tracks of single electrons with a range < 7 nm (cf width of DNA helix approximately2 nm). The electron tracks produced by these ultrasoft x-rays are similar to the numerous secondary electrons and 'track ends' produced by essentially all ionizing radiations. They therefore provide a unique tool in the study of mechanisms of radiation action in the cell. Conventional carbon targets used with the Medical Research Councils cold-cathode discharge tubes have a limited lifetime of 40-50 min. We have investigated the use of thin, freestanding diamond films produced using chemical vapour deposition techniques as a new transmission target for a cold-cathode tube. We present here a novel use of diamond to produce CK ultrasoft x-rays for irradiation purposes. The system described produces an entrance absorbed dose rate to attached cells of approximately 0.2 Gy min(-1) which due to the long target lifetime is usable for low dose-rate CK x-ray studies.


  • Is the increased relative biological effectiveness of high LET particles due to spatial or temporal effects? Characterization and OER in V79-4 cells

    by M A Hill, D L Stevens, S J Marsden, R Allott, I C E Turcu, D T Goodhead

    The efficiency of producing biological damage varies with radiation quality. Conventional explanations rely on spatial differences in the radiation track structure; generally however there are also very large temporal differences in delivery of the radiation at the cellular level. High-LET radiation normally deposits substantial amounts of energy by individual heavily ionizing tracks on a timescale of the order of picoseconds. By contrast each low-LET radiation track deposits a small amount of energy. Many of these tracks, distributed over the whole cell, are required to deliver an equivalent dose to a high-LET track and they are usually delivered over much longer timescales (typically seconds) during which chemical, biochemical and biological processes are occurring. In this paper the design, characterization and initial application of a high-brightness, laser-plasma ultrasoft x-ray source is described. This has been used to investigate the importance of the temporal differences by irradiating mammalian cells with an energy deposition with spatial properties of low-LET radiation and temporal properties similar to high-LET radiation. The present system delivers a typical dose, to the incident surface of the cells, of 0.12 Gy per pulse delivered in <10 ps. The capabilities of the x-ray source were tested by determining the survival of V79-4 hamster cells irradiated with picosecond pulses of ultrasoft x-rays under aerobic and anaerobic conditions, which were found to be consistent with previously published non pulsed data with x-rays of similar energy. These results support the expectation that the disappearance of an oxygen effect for high-LET radiation particles is due to their spatial properties rather than the very short timescale of each particle traversal. For other effects, particularly non-targeted phenomena such as induced genomic instability, expectations may be less clear cut.