Uri Rosenschein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Uri Rosenschein has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Alain Cribier
Charles Nicole Hospital, Rouen, France
2 shared publicationsAmir Halkin
Department of Cardiology, Tel Aviv Sourasky Medical Center, 6 Weizmann Street, Tel Aviv 64239 Israel
2 shared publicationsDavid Brosh
Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
2 shared publicationsFranz Amann
Universitaatspital, Zurich, Switzerland
2 shared publicationsShlomo Laniado
From the Tel Aviv Sourasky Medical Center (U.R., S.L., H.I.M.), Tel Aviv, Israel; Hanusch KH (G. Gaul), Vienna, Austria; Universitatsklinikum Essen (R.E.), Essen, Germany; Universitaatsspital Zurich (F.A.), Zurich, Switzerland; Medellin Clinic (D.V.), Medellin, Colombia; Herzzentrum Frankfurt (H.S.), Frankfurt, Germany; Uni Kiel (R.S.), Kiel, Germany; Shaio Clinic (G. Gomez), Bogata, Colombia; Stadt Klinikum Oldenburg (J.T.), Oldenburg, Germany; Centro Cardiologico Milan (A.B.), Milan, Italy;...
2 shared publicationsWalter Desmet
University Hospital Gasthuisberg, Leuven, Belgium
2 shared publications
Latest Publications
- 1 November 2003
- Vol. 5 (11) , 795-800
Coronary intervention in thrombus-rich lesions: beyond stents and glycoprotein IIb/IIIa inhibitors.
Despite widespread use of stents and GP IIb/IIIa antagonists, complications following percutaneous treatment of thrombus-rich lesions continue to plague patients with ACS. In these patients the angiographically evident coronary thrombosis may represent a high degree of thrombus burden, which leads to a higher level of microembolization and its clinical sequelae. New catheter-based thrombus burden reduction systems and distal protection devices show promise for improving the prognosis of these high risk patients by decreasing distal microembolization, and thereby preventing myonecrosis. Careful procedural timing and patient selection are also likely to improve outcomes and resource utilization in the management of ACS patients.
- 1 November 2003
- Vol. 5 (11) , 795-800
Coronary intervention in thrombus-rich lesions: beyond stents and glycoprotein IIb/IIIa inhibitors.
Despite widespread use of stents and GP IIb/IIIa antagonists, complications following percutaneous treatment of thrombus-rich lesions continue to plague patients with ACS. In these patients the angiographically evident coronary thrombosis may represent a high degree of thrombus burden, which leads to a higher level of microembolization and its clinical sequelae. New catheter-based thrombus burden reduction systems and distal protection devices show promise for improving the prognosis of these high risk patients by decreasing distal microembolization, and thereby preventing myonecrosis. Careful procedural timing and patient selection are also likely to improve outcomes and resource utilization in the management of ACS patients.
- 19 December 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (1) , 43-49
Percutaneous transluminal therapeutic ultrasound for high-risk thrombus-containing lesions in native coronary arteries
We assessed the short-term outcome of percutaneous coronary ultrasound thrombolysis (CUT) for high-risk thrombus-containing lesions in native coronaries in the setting of acute coronary syndromes (ACS). Data were prospectively collected in a multicenter (n = 32) registry of consecutive ACS patients. The study population (n = 126) had mostly (84%) totally occluded vessels. The mean age of clot was 5.7 +/- 9.5 days (range, 0-60 days). CUT (41 kHz, 18 W) led to device success in 112 (89%) patients, with a residual stenosis of 69% +/- 20%. Adjunct PTCA or stenting was used in 97% of the patients. Procedural success was achieved in 124 (98%) patients, with a final residual stenosis of 6% +/- 10%. There were no major adverse clinical events during hospitalization. Ultrasound thrombolysis is a feasible procedure that offers a safe and probably effective adjuvant device solution for the treatment of high-risk, thrombus-containing lesions in the native coronary arteries.
- 19 December 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (1) , 43-49
Percutaneous transluminal therapeutic ultrasound for high-risk thrombus-containing lesions in native coronary arteries
We assessed the short-term outcome of percutaneous coronary ultrasound thrombolysis (CUT) for high-risk thrombus-containing lesions in native coronaries in the setting of acute coronary syndromes (ACS). Data were prospectively collected in a multicenter (n = 32) registry of consecutive ACS patients. The study population (n = 126) had mostly (84%) totally occluded vessels. The mean age of clot was 5.7 +/- 9.5 days (range, 0-60 days). CUT (41 kHz, 18 W) led to device success in 112 (89%) patients, with a residual stenosis of 69% +/- 20%. Adjunct PTCA or stenting was used in 97% of the patients. Procedural success was achieved in 124 (98%) patients, with a final residual stenosis of 6% +/- 10%. There were no major adverse clinical events during hospitalization. Ultrasound thrombolysis is a feasible procedure that offers a safe and probably effective adjuvant device solution for the treatment of high-risk, thrombus-containing lesions in the native coronary arteries.
- 1 April 2001
- Published by Wiley in Echocardiography
- Vol. 18 (3) , 225-231
Catheter-delivered ultrasound therapy for native coronary arterial thrombosis and occluded saphenous vein grafts.
- 1 April 2001
- Published by Wiley in Echocardiography
- Vol. 18 (3) , 225-231
Catheter-delivered ultrasound therapy for native coronary arterial thrombosis and occluded saphenous vein grafts.
- 1 February 2001
- Vol. 3 (1) , 5-9
Coronary Ultrasound Thrombolysis: From Acute Myocardial Infarction to Saphenous Vein Grafts and Beyond.
During high-power ultrasound irradiation in fluids, microbubbles are formed and collapse to generate shock waves and induce fibrinolysis. In vivo, intracoronary injection of ultrasound-lysed clots increased myocardial perfusion. The experience with the ultrasound thrombolysis catheter in the ACUTE (Analysis of Coronary Ultrasound Thrombolysis Endpoints) trial showed that primary percutaneous coronary ultrasound thrombolysis (PCUT) in patients with anterior acute myocardial infarction and occluded left anterior descending artery was very successful in inducing safe and effective reperfusion and excellent myocardial salvage. The left ventricular ejection fraction at 6-month follow-up increased by 29% (P = 0.0005). The Acolysis Registry investigated prospectively PCUT in patients with acute coronary syndromes (n = 160) in a multicenter (n = 32) registry. Procedural success was achieved in 124 (98%) patients. In the saphenous vein graft (SVG) subset (n = 34), (78% of the vessels occluded at baseline) PCUT led to successful recanalization (TIMI 2-3) in 75% of the patients (P = 0.0003). Currently, PCUT is being evaluated in a randomized trial (ATLAS ) for the treatment of thrombus-containing coronary SVGs. These data suggest that thrombus debulking prior to percutaneous transluminal coronary intervention by therapeutic ultrasound is a very safe and effective percutaneous coronary intervention strategy. Ultrasound can be used to treat thrombi of a side spectrum of age and size.
- 1 February 2001
- Vol. 3 (1) , 5-9
Coronary Ultrasound Thrombolysis: From Acute Myocardial Infarction to Saphenous Vein Grafts and Beyond.
During high-power ultrasound irradiation in fluids, microbubbles are formed and collapse to generate shock waves and induce fibrinolysis. In vivo, intracoronary injection of ultrasound-lysed clots increased myocardial perfusion. The experience with the ultrasound thrombolysis catheter in the ACUTE (Analysis of Coronary Ultrasound Thrombolysis Endpoints) trial showed that primary percutaneous coronary ultrasound thrombolysis (PCUT) in patients with anterior acute myocardial infarction and occluded left anterior descending artery was very successful in inducing safe and effective reperfusion and excellent myocardial salvage. The left ventricular ejection fraction at 6-month follow-up increased by 29% (P = 0.0005). The Acolysis Registry investigated prospectively PCUT in patients with acute coronary syndromes (n = 160) in a multicenter (n = 32) registry. Procedural success was achieved in 124 (98%) patients. In the saphenous vein graft (SVG) subset (n = 34), (78% of the vessels occluded at baseline) PCUT led to successful recanalization (TIMI 2-3) in 75% of the patients (P = 0.0003). Currently, PCUT is being evaluated in a randomized trial (ATLAS ) for the treatment of thrombus-containing coronary SVGs. These data suggest that thrombus debulking prior to percutaneous transluminal coronary intervention by therapeutic ultrasound is a very safe and effective percutaneous coronary intervention strategy. Ultrasound can be used to treat thrombi of a side spectrum of age and size.
- 1 November 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 51 (3) , 332-334
Ultrasound thrombolysis in stent thrombosis
- 1 November 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 51 (3) , 332-334
Ultrasound thrombolysis in stent thrombosis
- 1 September 2000
- Vol. 5 (3) , 107
Introduction. Intracoronary thrombosis is the largest single cause of morbidity and mortality in the Western World.
- 1 September 2000
- Vol. 5 (3) , 107
Introduction. Intracoronary thrombosis is the largest single cause of morbidity and mortality in the Western World.
- 1 September 2000
- Vol. 5 (3) , 157-60
Treatment of lesions with thrombus: beyond stents and GP IIb/IIIa inhibitors.
In the presence of an intracoronary thrombus, percutaneous coronary intervention (PCI) will frequently lead to complications. Glycoprotein IIb/IIIa blockade as adjunct to PCI is very effective in patients with non-occlusive clots and biochemical evidence of platelet micro-embolization. Thrombotically-occluded vessels still remain a major clinical problem. This provides a rationale for thrombus debulking prior to PCI. A powerful antiplatelet agent used in combination with a thrombus debulking strategy and stenting of the underlying ruptured plaque offers the potential for further enhancement of PCI. Protection against embolization could potentially be optimized with the use of anti-embolization devices and covered stents.
- 1 September 2000
- Vol. 5 (3) , 157-60
Treatment of lesions with thrombus: beyond stents and GP IIb/IIIa inhibitors.
In the presence of an intracoronary thrombus, percutaneous coronary intervention (PCI) will frequently lead to complications. Glycoprotein IIb/IIIa blockade as adjunct to PCI is very effective in patients with non-occlusive clots and biochemical evidence of platelet micro-embolization. Thrombotically-occluded vessels still remain a major clinical problem. This provides a rationale for thrombus debulking prior to PCI. A powerful antiplatelet agent used in combination with a thrombus debulking strategy and stenting of the underlying ruptured plaque offers the potential for further enhancement of PCI. Protection against embolization could potentially be optimized with the use of anti-embolization devices and covered stents.
- 11 July 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (2) , 238-245
Ultrasound Imaging–Guided Noninvasive Ultrasound Thrombolysis
Background —Catheter-based therapeutic ultrasound thrombolysis was recently shown to be effective and safe. The purpose of this work was to study the safety and efficacy of external high-intensity focused ultrasound thrombolysis guided by ultrasound imaging in experimental settings. Methods and Results —A therapeutic transducer was constructed from an acoustic lens and integrated with an ultrasound imaging transducer. In vitro clots were inserted into bovine arterial segments and sonicated under real-time ultrasound imaging guidance in a water tank. With pulsed-wave (PW) ultrasound, the total sonication time correlated with thrombolysis efficiency ( r 2 =0.7666). A thrombolysis efficiency of 91% was achieved with optimal PW parameters (1:25 duty cycle, 200-μs pulse length) at an intensity (I spta ) of >35±5 W/cm 2 . Ultrasound imaging during sonication showed the cavitation field as a spherical cloud of echo-dense material. Within spta of 45 W/cm 2 was used for periods of ≥300 seconds. Conclusions —External high-intensity focused ultrasound thrombolysis using optimal PW parameters for periods of ≤300 seconds appears to be a safe and effective method to induce thrombolysis. The procedure can be guided by ultrasound imaging, thereby allowing the monitoring of therapy.
- 11 July 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (2) , 238-245
Ultrasound Imaging–Guided Noninvasive Ultrasound Thrombolysis
Background —Catheter-based therapeutic ultrasound thrombolysis was recently shown to be effective and safe. The purpose of this work was to study the safety and efficacy of external high-intensity focused ultrasound thrombolysis guided by ultrasound imaging in experimental settings. Methods and Results —A therapeutic transducer was constructed from an acoustic lens and integrated with an ultrasound imaging transducer. In vitro clots were inserted into bovine arterial segments and sonicated under real-time ultrasound imaging guidance in a water tank. With pulsed-wave (PW) ultrasound, the total sonication time correlated with thrombolysis efficiency ( r 2 =0.7666). A thrombolysis efficiency of 91% was achieved with optimal PW parameters (1:25 duty cycle, 200-μs pulse length) at an intensity (I spta ) of >35±5 W/cm 2 . Ultrasound imaging during sonication showed the cavitation field as a spherical cloud of echo-dense material. Within spta of 45 W/cm 2 was used for periods of ≥300 seconds. Conclusions —External high-intensity focused ultrasound thrombolysis using optimal PW parameters for periods of ≤300 seconds appears to be a safe and effective method to induce thrombolysis. The procedure can be guided by ultrasound imaging, thereby allowing the monitoring of therapy.
- 12 January 1999
- Published by Wolters Kluwer Health in Circulation
- Vol. 99 (1) , 26-29
Percutaneous Transluminal Therapy of Occluded Saphenous Vein Grafts
Background —Percutaneous transluminal treatment of a thrombotic vein graft yields poor results. We have previously reported our experience with transluminal percutaneous coronary ultrasound thrombolysis (CUT) in the setting of acute myocardial infarction (AMI). This report describes the first experience with ultrasound thrombolysis in thrombus-rich lesions in saphenous vein grafts (SVGs), most of which were occluded. Methods and Results —The patients (n=20) were mostly male (85%), aged 64±4 years old. The presenting symptom was AMI in 2 patients (10%) and unstable angina in the rest. Fifteen patients (75%) had totally occluded SVGs. The median age of clots was 6 days (range, 0 to 100 days). The ultrasound thrombolysis device has a 1.6-mm-long tip and fits into a 7F guiding catheter over a 0.014-in guidewire in a “rapid-exchange” system. CUT (41 kHz, 18 W, ≤6 minutes) led to device success in 14 (70%) of the patients and residual stenosis of 65±28%. Procedural success was obtained in 13 (65%) of the patients, with a final residual stenosis of 5±8%. There was a low rate of device-related adverse events: 1 patient (5%) had a non–Q-wave myocardial infarction, and distal embolization was noted in 1 patient (5%). Adjunct PTCA or stenting was used in all patients. There were no serious adverse events during hospitalization. Conclusions —Ultrasound thrombolysis in thrombus-rich lesions in SVGs offers a very promising therapeutic option.
- 12 January 1999
- Published by Wolters Kluwer Health in Circulation
- Vol. 99 (1) , 26-29
Percutaneous Transluminal Therapy of Occluded Saphenous Vein Grafts
Background —Percutaneous transluminal treatment of a thrombotic vein graft yields poor results. We have previously reported our experience with transluminal percutaneous coronary ultrasound thrombolysis (CUT) in the setting of acute myocardial infarction (AMI). This report describes the first experience with ultrasound thrombolysis in thrombus-rich lesions in saphenous vein grafts (SVGs), most of which were occluded. Methods and Results —The patients (n=20) were mostly male (85%), aged 64±4 years old. The presenting symptom was AMI in 2 patients (10%) and unstable angina in the rest. Fifteen patients (75%) had totally occluded SVGs. The median age of clots was 6 days (range, 0 to 100 days). The ultrasound thrombolysis device has a 1.6-mm-long tip and fits into a 7F guiding catheter over a 0.014-in guidewire in a “rapid-exchange” system. CUT (41 kHz, 18 W, ≤6 minutes) led to device success in 14 (70%) of the patients and residual stenosis of 65±28%. Procedural success was obtained in 13 (65%) of the patients, with a final residual stenosis of 5±8%. There was a low rate of device-related adverse events: 1 patient (5%) had a non–Q-wave myocardial infarction, and distal embolization was noted in 1 patient (5%). Adjunct PTCA or stenting was used in all patients. There were no serious adverse events during hospitalization. Conclusions —Ultrasound thrombolysis in thrombus-rich lesions in SVGs offers a very promising therapeutic option.
- 1 December 1998
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 11 (6) , 603-607
Ultrasound Thrombolysis: An Alternative to the Pharmacological Approach
- 1 December 1998
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 11 (6) , 603-607
Ultrasound Thrombolysis: An Alternative to the Pharmacological Approach