CMC. R. Müller

C. R. Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


C. R. Müller has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • A. N. Hayhurst

    Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK

    1 shared publication
  • Andrew J. Sederman

    Department of Chemical Engineering and Biotechnology, University of Cambridge, West Cambridge Site, Philippa Fawcett Drive, Cambridge CB3 0AS, United Kingdom

    1 shared publication
  • Daniel J. Holland

    University of Canterbury

    1 shared publication
  • J. F. Davidson

    Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK

    1 shared publication
  • J. S. Dennis

    Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK

    1 shared publication
  • L. F. Gladden

    Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK

    1 shared publication

Latest Publications

  • Geometrical and hydrodynamical study of gas jets in packed and fluidized beds using magnetic resonance

    by C. R. Müller, D. J. Holland, J. F. Davidson, J. S. Dennis, L. F. Gladden, A. N. Hayhurst, M. D. Mantle, A. J. Sederman

    Magnetic resonance (MR) was used to image the motion of particles and gas just above the distributor of 3D beds of particles fluidized by air. Three different distributors were used: (i) a single‐orifice distributor, with orifice diameters 1.0–4.0 mm, (ii) a plate, drilled with a triangular array of 79 holes, each of 0.35 mm diameter, with a central nozzle containing a single hole of diameter 1.0, 2.5, or 9.0 mm, (iii) distributors with two or three orifices and diameters of 1.0 or 2.5 mm. It proved possible to extract geometrical information, such as the length of a jet, from MR images, each averaged over ∼5 min. Also, light was shed on the question of why is there such a discrepancy between reported jet‐lengths. The fluidization state, the “start‐up” procedure and also the number of holes all play a significant role in determining the measured distance a jet penetrates into a bed. The question as to whether the observed voids represent permanent jets or streams of bubbles was considered. The evidence from ultra‐fast MR measurements strongly suggests that only the lower part of a jet from an orifice in a multi‐orifice distributor is permanent; bubbles form at the top of the jet. Consequently, the top of each jet is transient. However, most of the jet from a single orifice is a permanent cavity when the bed of particles is not fluidized. The length of a jet was successfully correlated with operating variables using dimensional analysis. Finally, the flow of particles around a single jet was measured with high resolution MR.