Robert E. Imhof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert E. Imhof has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Peng Xiao
South Bank University, School of EEIE, 103 Borough Road, London SE1 0AA, United Kingdom
4 shared publications- Perry Xiao
School of Engineering, London South Bank University, London SE1 0AA, UK
2 shared publications Bufa Zhang
South Bank Univ. (United Kingdom)
1 shared publicationE. P. Berg
Biox Systems Ltd, Southwark Campus, 103 Borough Road, London SE1 0AA, UK
1 shared publicationJean de Rigal
L’Oréal, Recherche Avancée, 188 rue Paul Hochart, F-94 152 Chevilly-Larue, France
1 shared publicationJeremy J. Andrew
Unilever Research Port Sunlight Lab. (United Kingdom)
1 shared publication
Latest Publications
- 1 October 2012
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 435 (1) , 88-92
Two dimensional finite element modelling for dynamic water diffusion through stratum corneum
- 1 October 2012
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 435 (1) , 88-92
Two dimensional finite element modelling for dynamic water diffusion through stratum corneum
- 24 February 2009
- Published by Wiley in International Journal of Cosmetic Science
- Vol. 31 (2) , 97-118
Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performance
Synopsis: The importance of transepidermal water loss (TEWL) as a measure of the skin barrier is well recognized. Currently, the open‐chamber method is dominant, but it is increasingly challenged by newer closed‐chamber technologies. Whilst there is familiarity with open‐chamber characteristics, there is uncertainty about the capabilities of the challengers. The main issues are related to how microclimate affects TEWL measurements.The aim of this paper is to provide a framework for understanding the effects of microclimate on TEWL measurement. Part of the problem is that TEWL measurement is indirect. TEWL is the diffusion of condensed water through the stratum corneum (SC), whereas TEWL methods measure water vapour flux in the air above the SC. This vapour flux depends on (i) the rate of supply of water to the skin surface and (ii) the rate of evaporation of water from the skin surface. Rate (i) is a skin property (TEWL), rate (ii) is a microclimate property. The controlling rate for the combined process is the lower of the above two rates. Therefore, TEWL instruments measure TEWL only when TEWL is the rate‐limiting process.Another problem is that SC barrier property and SC hydration are affected by the microclimate adjacent to the skin surface. This is discussed insofar as it affects the measurement of TEWL. The conclusion is that such changes occur on a timescale that is long compared with TEWL measurement times.An important aspect of TEWL measurement is calibration. We present an analysis of the traditional wet‐cup method and a new droplet method that is traceable and has been independently verified by a standards laboratory.Finally, we review performance indicators of commercial closed‐chamber instruments with reference to open‐chamber instruments. The main findings are that TEWL readings correlate well, but there are significant differences in the other aspects of performance.
- 24 February 2009
- Published by Wiley in International Journal of Cosmetic Science
- Vol. 31 (2) , 97-118
Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performance
Synopsis: The importance of transepidermal water loss (TEWL) as a measure of the skin barrier is well recognized. Currently, the open‐chamber method is dominant, but it is increasingly challenged by newer closed‐chamber technologies. Whilst there is familiarity with open‐chamber characteristics, there is uncertainty about the capabilities of the challengers. The main issues are related to how microclimate affects TEWL measurements.The aim of this paper is to provide a framework for understanding the effects of microclimate on TEWL measurement. Part of the problem is that TEWL measurement is indirect. TEWL is the diffusion of condensed water through the stratum corneum (SC), whereas TEWL methods measure water vapour flux in the air above the SC. This vapour flux depends on (i) the rate of supply of water to the skin surface and (ii) the rate of evaporation of water from the skin surface. Rate (i) is a skin property (TEWL), rate (ii) is a microclimate property. The controlling rate for the combined process is the lower of the above two rates. Therefore, TEWL instruments measure TEWL only when TEWL is the rate‐limiting process.Another problem is that SC barrier property and SC hydration are affected by the microclimate adjacent to the skin surface. This is discussed insofar as it affects the measurement of TEWL. The conclusion is that such changes occur on a timescale that is long compared with TEWL measurement times.An important aspect of TEWL measurement is calibration. We present an analysis of the traditional wet‐cup method and a new droplet method that is traceable and has been independently verified by a standards laboratory.Finally, we review performance indicators of commercial closed‐chamber instruments with reference to open‐chamber instruments. The main findings are that TEWL readings correlate well, but there are significant differences in the other aspects of performance.
- 1 January 1999
- Published by AIP Publishing
- Vol. 463 (1) , 597
Photothermal measurement of in-vitro stratum corneum hydration in a controlled humidity environment
We report measurements of in-vitro stratum corneum hydration under controlled humidity conditions. The measurements used an opto-thermal transient emission radiometry (OTTER) instrument with 2.94 μm Er:YAG excitation and wavelength selective detection, to maximise the sensitivity for water.
- 1 January 1999
- Published by AIP Publishing
- Vol. 463 (1) , 597
Photothermal measurement of in-vitro stratum corneum hydration in a controlled humidity environment
We report measurements of in-vitro stratum corneum hydration under controlled humidity conditions. The measurements used an opto-thermal transient emission radiometry (OTTER) instrument with 2.94 μm Er:YAG excitation and wavelength selective detection, to maximise the sensitivity for water.
- 1 January 1999
- Published by AIP Publishing
- Vol. 463 (1) , 573
Water diffusion within the stratum corneum
We report the development of a new technique for measuring the water distribution and water diffusion within the top ten microns of human skin. It is remote sensing and can be applied non-destructively to arbitrary condensed samples. It achieves a high specificity for water by exploiting optical absorption peaks in the middle infrared spectral region. We present examples of in-vitro and in-vivo measurements of surface hydration and water concentration gradient in human stratum corneum.
- 1 January 1999
- Published by AIP Publishing
- Vol. 463 (1) , 573
Water diffusion within the stratum corneum
We report the development of a new technique for measuring the water distribution and water diffusion within the top ten microns of human skin. It is remote sensing and can be applied non-destructively to arbitrary condensed samples. It achieves a high specificity for water by exploiting optical absorption peaks in the middle infrared spectral region. We present examples of in-vitro and in-vivo measurements of surface hydration and water concentration gradient in human stratum corneum.
- 22 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2970, 276-287
Optothermal measurement of stratum corneum thickness and hydration-depth profile
Opto-thermal in-vivo measurements of stratum corneum hydration can now be evaluated to give hydration depth profiles from a mathematical model that incorporates both the surface hydration and the changes of hydration with depth beneath the surface. We now present an analysis of water diffusion in the stratum corneum that can be related to such measurements. The results are compared with measurements of changes of surface hydration and hydration gradient with depth in a stratum corneum stripping experiment. Surface hydration and hydration gradient information can also be combined to yield a measure of stratum corneum thickness, as illustrated with a measured thickness map of the volar forearm.
- 22 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2970, 276-287
Optothermal measurement of stratum corneum thickness and hydration-depth profile
Opto-thermal in-vivo measurements of stratum corneum hydration can now be evaluated to give hydration depth profiles from a mathematical model that incorporates both the surface hydration and the changes of hydration with depth beneath the surface. We now present an analysis of water diffusion in the stratum corneum that can be related to such measurements. The results are compared with measurements of changes of surface hydration and hydration gradient with depth in a stratum corneum stripping experiment. Surface hydration and hydration gradient information can also be combined to yield a measure of stratum corneum thickness, as illustrated with a measured thickness map of the volar forearm.
- 7 May 1996
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2681, 17-31
Skin condition assessment: a comparative study of techniques
We report the results of a study aimed at comparing Opto-Thermal Transient Emission Radiometry (OTTER) with established techniques of assessing skin condition, namely evaporimetry (TEWL), skin dielectric constant measurement, ATR-FTIR and clinical assessment. Comparisons were made during a week-long study of the effects of intensive washing on the volar forearms of 14 subjects. The study also provided a comparison of skin condition after washing with two different cleansers, a mild isethionate betaine cleansing bar and a soap bar. The subject-averaged results from OTTER and TEWL were found to correlate with the clinical assessments, namely that intensive washing with the soap bar produces greater skin damage than with the isethionate betaine bar. Skin dielectric constant measurements were found to be sensitive to changes of skin condition other than hydration, as evidenced by a daily oscillation that dominate the results. The ATR-FTIR measurements proved difficult to evaluate, because of interfering calcium deposits from the soap bar. On the practical side, OTTER and skin dielectric constant measurements were found to be quicker and more convenient to use than TEWL and ATR-FTIR.
- 7 May 1996
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2681, 17-31
Skin condition assessment: a comparative study of techniques
We report the results of a study aimed at comparing Opto-Thermal Transient Emission Radiometry (OTTER) with established techniques of assessing skin condition, namely evaporimetry (TEWL), skin dielectric constant measurement, ATR-FTIR and clinical assessment. Comparisons were made during a week-long study of the effects of intensive washing on the volar forearms of 14 subjects. The study also provided a comparison of skin condition after washing with two different cleansers, a mild isethionate betaine cleansing bar and a soap bar. The subject-averaged results from OTTER and TEWL were found to correlate with the clinical assessments, namely that intensive washing with the soap bar produces greater skin damage than with the isethionate betaine bar. Skin dielectric constant measurements were found to be sensitive to changes of skin condition other than hydration, as evidenced by a daily oscillation that dominate the results. The ATR-FTIR measurements proved difficult to evaluate, because of interfering calcium deposits from the soap bar. On the practical side, OTTER and skin dielectric constant measurements were found to be quicker and more convenient to use than TEWL and ATR-FTIR.