Tobias Heimann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Heimann has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Hans-Peter Meinzer
6 shared publicationsIvo Wolf
Div. of Med. & Biol. Inf., German Cancer Res. Center, Heidelberg, Germany
5 shared publications- Hans-Peter Meinzer
German Cancer Research Ctr. (Germany)
3 shared publications Anne-Mareike Rau
Div. of Med. & Biol. Inf., German Cancer Res. Center, Heidelberg, Germany
2 shared publicationsTobias Schwarz
German Cancer Research Ctr. (Germany)
2 shared publicationsAkinobu Shimizu
Div. of Med. & Biol. Inf., German Cancer Res. Center, Heidelberg, Germany
1 shared publication
Latest Publications
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 796312
Analysis of adipose tissue distribution using whole-body magnetic resonance imaging
Obesity is an increasing problem in the western world and triggers diseases like cancer, type two diabetes, and cardiovascular diseases. In recent years, magnetic resonance imaging (MRI) has become a clinically viable method to measure the amount and distribution of adipose tissue (AT) in the body. However, analysis of MRI images by manual segmentation is a tedious and time-consuming process. In this paper, we propose a semi-automatic method to quantify the amount of different AT types from whole-body MRI data with less user interaction. Initially, body fat is extracted by automatic thresholding. A statistical shape model of the abdomen is then used to differentiate between subcutaneous and visceral AT. Finally, fat in the bone marrow is removed using morphological operators. The proposed method was evaluated on 15 whole-body MRI images using manual segmentation as ground truth for adipose tissue. The resulting overlap for total AT was 93.7% ± 5.5 with a volumetric difference of 7.3% ± 6.4. Furthermore, we tested the robustness of the segmentation results with regard to the initial, interactively defined position of the shape model. In conclusion, the developed method proved suitable for the analysis of AT distribution from whole-body MRI data. For large studies, a fully automatic version of the segmentation procedure is expected in the near future.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 796312
Analysis of adipose tissue distribution using whole-body magnetic resonance imaging
Obesity is an increasing problem in the western world and triggers diseases like cancer, type two diabetes, and cardiovascular diseases. In recent years, magnetic resonance imaging (MRI) has become a clinically viable method to measure the amount and distribution of adipose tissue (AT) in the body. However, analysis of MRI images by manual segmentation is a tedious and time-consuming process. In this paper, we propose a semi-automatic method to quantify the amount of different AT types from whole-body MRI data with less user interaction. Initially, body fat is extracted by automatic thresholding. A statistical shape model of the abdomen is then used to differentiate between subcutaneous and visceral AT. Finally, fat in the bone marrow is removed using morphological operators. The proposed method was evaluated on 15 whole-body MRI images using manual segmentation as ground truth for adipose tissue. The resulting overlap for total AT was 93.7% ± 5.5 with a volumetric difference of 7.3% ± 6.4. Furthermore, we tested the robustness of the segmentation results with regard to the initial, interactively defined position of the shape model. In conclusion, the developed method proved suitable for the analysis of AT distribution from whole-body MRI data. For large studies, a fully automatic version of the segmentation procedure is expected in the near future.
- Top Cited Papers
- 1 August 2009
- Published by Elsevier in Medical Image Analysis
- Vol. 13 (4) , 543-563
Statistical shape models for 3D medical image segmentation: A review
- 1 August 2009
- Published by Elsevier in Medical Image Analysis
- Vol. 13 (4) , 543-563
Top Cited PapersStatistical shape models for 3D medical image segmentation: A review
- Top Cited Papers
- 10 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28 (8) , 1251-1265
Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets
This paper presents a comparison study between 10 automatic and six interactive methods for liver segmentation from contrast-enhanced CT images. It is based on results from the "MICCAI 2007 Grand Challenge" workshop, where 16 teams evaluated their algorithms on a common database. A collection of 20 clinical images with reference segmentations was provided to train and tune algorithms in advance. Participants were also allowed to use additional proprietary training data for that purpose. All teams then had to apply their methods to 10 test datasets and submit the obtained results. Employed algorithms include statistical shape models, atlas registration, level-sets, graph-cuts and rule-based systems. All results were compared to reference segmentations five error measures that highlight different aspects of segmentation accuracy. All measures were combined according to a specific scoring system relating the obtained values to human expert variability. In general, interactive methods reached higher average scores than automatic approaches and featured a better consistency of segmentation quality. However, the best automatic methods (mainly based on statistical shape models with some additional free deformation) could compete well on the majority of test images. The study provides an insight in performance of different segmentation approaches under real-world conditions and highlights achievements and limitations of current image analysis techniques.
- 10 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28 (8) , 1251-1265
Top Cited PapersComparison and Evaluation of Methods for Liver Segmentation From CT Datasets
This paper presents a comparison study between 10 automatic and six interactive methods for liver segmentation from contrast-enhanced CT images. It is based on results from the "MICCAI 2007 Grand Challenge" workshop, where 16 teams evaluated their algorithms on a common database. A collection of 20 clinical images with reference segmentations was provided to train and tune algorithms in advance. Participants were also allowed to use additional proprietary training data for that purpose. All teams then had to apply their methods to 10 test datasets and submit the obtained results. Employed algorithms include statistical shape models, atlas registration, level-sets, graph-cuts and rule-based systems. All results were compared to reference segmentations five error measures that highlight different aspects of segmentation accuracy. All measures were combined according to a specific scoring system relating the obtained values to human expert variability. In general, interactive methods reached higher average scores than automatic approaches and featured a better consistency of segmentation quality. However, the best automatic methods (mainly based on statistical shape models with some additional free deformation) could compete well on the majority of test images. The study provides an insight in performance of different segmentation approaches under real-world conditions and highlights achievements and limitations of current image analysis techniques.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6914, 69143O-69143
Interactive surface correction for 3D shape based segmentation
Statistical shape models have become a fast and robust method for segmentation of anatomical structures in medical image volumes. In clinical practice, however, pathological cases and image artifacts can lead to local deviations of the detected contour from the true object boundary. These deviations have to be corrected manually. We present an intuitively applicable solution for surface interaction based on Gaussian deformation kernels. The method is evaluated by two radiological experts on segmentations of the liver in contrast-enhanced CT images and of the left heart ventricle (LV) in MRI data. For both applications, five datasets are segmented automatically using deformable shape models, and the resulting surfaces are corrected manually. The interactive correction step improves the average surface distance against ground truth from 2.43mm to 2.17mm for the liver, and from 2.71mm to 1.34mm for the LV. We expect this method to raise the acceptance of automatic segmentation methods in clinical application.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6914, 69143O-69143
Interactive surface correction for 3D shape based segmentation
Statistical shape models have become a fast and robust method for segmentation of anatomical structures in medical image volumes. In clinical practice, however, pathological cases and image artifacts can lead to local deviations of the detected contour from the true object boundary. These deviations have to be corrected manually. We present an intuitively applicable solution for surface interaction based on Gaussian deformation kernels. The method is evaluated by two radiological experts on segmentations of the liver in contrast-enhanced CT images and of the left heart ventricle (LV) in MRI data. For both applications, five datasets are segmented automatically using deformable shape models, and the resulting surfaces are corrected manually. The interactive correction step improves the average surface distance against ground truth from 2.43mm to 2.17mm for the liver, and from 2.71mm to 1.34mm for the LV. We expect this method to raise the acceptance of automatic segmentation methods in clinical application.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69151V
Neurodegenerative changes in Alzheimer's disease: a comparative study of manual, semi-automated, and fully automated assessment using MRI
Objective quantification of disease specific neurodegenerative changes can facilitate diagnosis and therapeutic monitoring in several neuropsychiatric disorders. Reproducibility and easy-to-perform assessment are essential to ensure applicability in clinical environments. Aim of this comparative study is the evaluation of a fully automated approach that assesses atrophic changes in Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI). 21 healthy volunteers (mean age 66.2), 21 patients with MCI (66.6), and 10 patients with AD (65.1) were enrolled. Subjects underwent extensive neuropsychological testing and MRI was conducted on a 1.5 Tesla clinical scanner. Atrophic changes were measured automatically by a series of image processing steps including state of the art brain mapping techniques. Results were compared with two reference approaches: a manual segmentation of the hippocampal formation and a semi-automated estimation of temporal horn volume, which is based upon interactive selection of two to six landmarks in the ventricular system. All approaches separated controls and AD patients significantly (10-5 -4) and showed a slight but not significant increase of neurodegeneration for subjects with MCI compared to volunteers. The automated approach correlated significantly with the manual (r = -0.65, p -6) and semi automated (r = -0.83, p -13) measurements. It proved high accuracy and at the same time maximized observer independency, time reduction and thus usefulness for clinical routine.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6915, 69151V
Neurodegenerative changes in Alzheimer's disease: a comparative study of manual, semi-automated, and fully automated assessment using MRI
Objective quantification of disease specific neurodegenerative changes can facilitate diagnosis and therapeutic monitoring in several neuropsychiatric disorders. Reproducibility and easy-to-perform assessment are essential to ensure applicability in clinical environments. Aim of this comparative study is the evaluation of a fully automated approach that assesses atrophic changes in Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI). 21 healthy volunteers (mean age 66.2), 21 patients with MCI (66.6), and 10 patients with AD (65.1) were enrolled. Subjects underwent extensive neuropsychological testing and MRI was conducted on a 1.5 Tesla clinical scanner. Atrophic changes were measured automatically by a series of image processing steps including state of the art brain mapping techniques. Results were compared with two reference approaches: a manual segmentation of the hippocampal formation and a semi-automated estimation of temporal horn volume, which is based upon interactive selection of two to six landmarks in the ventricular system. All approaches separated controls and AD patients significantly (10-5 -4) and showed a slight but not significant increase of neurodegeneration for subjects with MCI compared to volunteers. The automated approach correlated significantly with the manual (r = -0.65, p -6) and semi automated (r = -0.83, p -13) measurements. It proved high accuracy and at the same time maximized observer independency, time reduction and thus usefulness for clinical routine.
- 1 January 2007
- Published by Springer Nature
- Vol. 20, 1-12
A Shape-Guided Deformable Model with Evolutionary Algorithm Initialization for 3D Soft Tissue Segmentation
We present a novel method for the segmentation of volumetric images, which is especially suitable for highly variable soft tissue structures. Core of the algorithm is a statistical shape model (SSM) of the structure of interest. A global search with an evolutionary algorithm is employed to detect suitable initial parameters for the model, which are subsequently optimized by a local search similar to the Active Shape mechanism. After that, a deformable mesh with the same topology as the SSM is used for the final segmentation: While external forces strive to maximize the posterior probability of the mesh given the local appearance around the boundary, internal forces governed by tension and rigidity terms keep the shape similar to the underlying SSM. To prevent outliers and increase robustness, we determine the applied external forces by an algorithm for optimal surface detection with smoothness constraints. The approach is evaluated on 54 CT images of the liver and reaches an average surface distance of 1.6 ±0.5 mm in comparison to manual reference segmentations.
- 1 January 2007
- Published by Springer Nature
- Vol. 20, 1-12
A Shape-Guided Deformable Model with Evolutionary Algorithm Initialization for 3D Soft Tissue Segmentation
We present a novel method for the segmentation of volumetric images, which is especially suitable for highly variable soft tissue structures. Core of the algorithm is a statistical shape model (SSM) of the structure of interest. A global search with an evolutionary algorithm is employed to detect suitable initial parameters for the model, which are subsequently optimized by a local search similar to the Active Shape mechanism. After that, a deformable mesh with the same topology as the SSM is used for the final segmentation: While external forces strive to maximize the posterior probability of the mesh given the local appearance around the boundary, internal forces governed by tension and rigidity terms keep the shape similar to the underlying SSM. To prevent outliers and increase robustness, we determine the applied external forces by an algorithm for optimal surface detection with smoothness constraints. The approach is evaluated on 54 CT images of the liver and reaches an average surface distance of 1.6 ±0.5 mm in comparison to manual reference segmentations.
- 1 January 2007
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 46 (03) , 275-281
Automatic Generation of 3D Statistical Shape Models with Optimal Landmark Distributions
Summary: Objectives: To point out the problem of non-uniform landmark placement in statistical shape modeling, to present an improved method for generating landmarks in the 3D case and to propose an unbiased evaluation metric to determine model quality. Methods: Our approach minimizes a cost function based on the minimum description length (MDL) of the shape model to optimize landmark correspondences over the training set. In addition to the standard technique, we employ an extended remeshing method to change the landmark distribution without losing correspondences, thus ensuring a uniform distribution over all training samples. To breakthe dependency of the established evaluation measures generalization and specificity from the landmark distribution, we change the internal metric from landmark distance to volumetric overlap. Results: Redistributing landmarks to an equally spaced distribution during the model construction phase improves the quality of the resulting models significantly if the shapes feature prominent bulges or other complex geometry. Conclusions: The distribution of landmarks on the training shapes is – beyond the correspondence issue – a crucial point in model construction.
- 1 January 2007
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 46 (03) , 275-281
Automatic Generation of 3D Statistical Shape Models with Optimal Landmark Distributions
Summary: Objectives: To point out the problem of non-uniform landmark placement in statistical shape modeling, to present an improved method for generating landmarks in the 3D case and to propose an unbiased evaluation metric to determine model quality. Methods: Our approach minimizes a cost function based on the minimum description length (MDL) of the shape model to optimize landmark correspondences over the training set. In addition to the standard technique, we employ an extended remeshing method to change the landmark distribution without losing correspondences, thus ensuring a uniform distribution over all training samples. To breakthe dependency of the established evaluation measures generalization and specificity from the landmark distribution, we change the internal metric from landmark distance to volumetric overlap. Results: Redistributing landmarks to an equally spaced distribution during the model construction phase improves the quality of the resulting models significantly if the shapes feature prominent bulges or other complex geometry. Conclusions: The distribution of landmarks on the training shapes is – beyond the correspondence issue – a crucial point in model construction.
- 25 May 2006
- Published by Springer Nature
- p. 166-170
Automatische Erstellung von gleichmäßig verteilten Landmarken füur statistische Formmodelle
- 25 May 2006
- Published by Springer Nature
- p. 166-170
Automatische Erstellung von gleichmäßig verteilten Landmarken füur statistische Formmodelle
- 1 January 2006
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 9, 41-48
Active Shape Models for a Fully Automated 3D Segmentation of the Liver – An Evaluation on Clinical Data
This paper presents an evaluation of the performance of a three-dimensional Active Shape Model (ASM) to segment the liver in 48 clinical CT scans. The employed shape model is built from 32 samples using an optimization approach based on the minimum description length (MDL). Three different gray-value appearance models (plain intensity, gradient and normalized gradient profiles) are created to guide the search. The employed segmentation techniques are ASM search with 10 and 30 modes of variation and a deformable model coupled to a shape model with 10 modes of variation. To assess the segmentation performance, the obtained results are compared to manual segmentations with four different measures (overlap, average distance, RMS distance and ratio of deviations larger 5mm). The only appearance model delivering usable results is the normalized gradient profile. The deformable model search achieves the best results, followed by the ASM search with 30 modes. Overall, statistical shape modeling delivers very promising results for a fully automated segmentation of the liver.
- 1 January 2006
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 9, 41-48
Active Shape Models for a Fully Automated 3D Segmentation of the Liver – An Evaluation on Clinical Data
This paper presents an evaluation of the performance of a three-dimensional Active Shape Model (ASM) to segment the liver in 48 clinical CT scans. The employed shape model is built from 32 samples using an optimization approach based on the minimum description length (MDL). Three different gray-value appearance models (plain intensity, gradient and normalized gradient profiles) are created to guide the search. The employed segmentation techniques are ASM search with 10 and 30 modes of variation and a deformable model coupled to a shape model with 10 modes of variation. To assess the segmentation performance, the obtained results are compared to manual segmentations with four different measures (overlap, average distance, RMS distance and ratio of deviations larger 5mm). The only appearance model delivering usable results is the normalized gradient profile. The deformable model search achieves the best results, followed by the ASM search with 30 modes. Overall, statistical shape modeling delivers very promising results for a fully automated segmentation of the liver.