Jonathan S. Cole
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jonathan S. Cole has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
J.K. Watterson
School of Aeronautical Engineering, The Queen's University of Belfast, Belfast BT9 5AG, UK
2 shared publicationsAbi Spence
University of Wolverhampton
1 shared publication- Ali Al-Humuzi
McMaster University
1 shared publication - Alison Cook-Sather
Bryn Mawr College
1 shared publication - Amrita Kaur
Wenzhou-Kean University
1 shared publication - Andrew Kelly
Edith Cowan University
1 shared publication
Latest Publications
- Open Access
- 16 October 2023
- Published by McMaster University Library in International Journal for Students as Partners
- Vol. 7 (2) , 221-240
How can students-as-partners work address challenges to student, faculty, and staff mental health and well-being?
- 16 October 2023
- Published by McMaster University Library in International Journal for Students as Partners
- Vol. 7 (2) , 221-240
Open AccessHow can students-as-partners work address challenges to student, faculty, and staff mental health and well-being?
- Open Access
Highlighting Hemodynamic Risks for Bioresorbable Stents in Coronary Arteries
A three-dimensional, transient computational fluid dynamics analysis was conducted on an idealised geometry of a coronary artery fitted with representative geometries of an Absorb bioresorbable vascular scaffold (BVS) or a Xience drug-eluting stent (DES) in order to identify and compare areas of disturbed flow and potential risk sites. A non-Newtonian viscosity model was used with a transient velocity boundary condition programmed with user-defined functions. At-risk areas were quantified in terms of several parameters linked to restenosis: wall shear stress, time-averaged wall shear stress, oscillatory shear index, particle residence time, and shear rate. Results indicated that 71% of the BVS stented surface area had time-averaged wall shear stress values under 0.4 Pa compared to 45% of the DES area. Additionally, high particle residence times were present in 23% and 8% of the BVS and DES areas, respectively, with risk areas identified as being more prominent in close proximity to crowns and link struts. These results suggest an increased risk for thrombosis and neointimal hyperplasia for the BVS compared to the DES, which is in agreement with the outcomes of clinical trials. It is intended that the results of this study may be used as a pre-clinical tool to aid in the design of bioresorbable coronary stents.
Open AccessHighlighting Hemodynamic Risks for Bioresorbable Stents in Coronary Arteries
A three-dimensional, transient computational fluid dynamics analysis was conducted on an idealised geometry of a coronary artery fitted with representative geometries of an Absorb bioresorbable vascular scaffold (BVS) or a Xience drug-eluting stent (DES) in order to identify and compare areas of disturbed flow and potential risk sites. A non-Newtonian viscosity model was used with a transient velocity boundary condition programmed with user-defined functions. At-risk areas were quantified in terms of several parameters linked to restenosis: wall shear stress, time-averaged wall shear stress, oscillatory shear index, particle residence time, and shear rate. Results indicated that 71% of the BVS stented surface area had time-averaged wall shear stress values under 0.4 Pa compared to 45% of the DES area. Additionally, high particle residence times were present in 23% and 8% of the BVS and DES areas, respectively, with risk areas identified as being more prominent in close proximity to crowns and link struts. These results suggest an increased risk for thrombosis and neointimal hyperplasia for the BVS compared to the DES, which is in agreement with the outcomes of clinical trials. It is intended that the results of this study may be used as a pre-clinical tool to aid in the design of bioresorbable coronary stents.
- Open Access
- 5 September 2016
- Published by University of Greenwich in MSOR Connections
- Vol. 15 (1) , 56
The Pilot Maths Centre at the North West Regional College
This paper discusses the establishment in 2015 of the first Maths Centre in any Further and Higher Education College in Northern Ireland. In particular, it considers the rationale for its development, how it was set up and how it runs. It also presents initial figures and feedback, and plans for future developments.
- 5 September 2016
- Published by University of Greenwich in MSOR Connections
- Vol. 15 (1) , 56
Open AccessThe Pilot Maths Centre at the North West Regional College
This paper discusses the establishment in 2015 of the first Maths Centre in any Further and Higher Education College in Northern Ireland. In particular, it considers the rationale for its development, how it was set up and how it runs. It also presents initial figures and feedback, and plans for future developments.
- 6 September 2012
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 37 (5) , 508-525
Using continuous assessment to promote student engagement in a large class
The authors have developed a first-year fluids course for a class of around 230 aerospace, civil and mechanical engineering students. This paper aims to show how the teaching and assessment methodology was applied to the challenge of a large class. The lectures featured formal teaching interspersed with active learning elements. Smaller group (about 25–30 students) tutorial classes involved student practice. A 10-minute test occurred in each tutorial during weeks 3–11. Each test was based on the previous week's lecture material and the marks contributed towards 20% of the course mark. A condition for passing the course was that a student must pass at least six of the nine tests. The assessment promoted student involvement with the course – tutorial attendance was greater and more uniform than previously and exam performance improved significantly. Students recognised that the assessment system was useful in encouraging continuous learning over the semester and building confidence.
- 6 September 2012
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 37 (5) , 508-525
Using continuous assessment to promote student engagement in a large class
The authors have developed a first-year fluids course for a class of around 230 aerospace, civil and mechanical engineering students. This paper aims to show how the teaching and assessment methodology was applied to the challenge of a large class. The lectures featured formal teaching interspersed with active learning elements. Smaller group (about 25–30 students) tutorial classes involved student practice. A 10-minute test occurred in each tutorial during weeks 3–11. Each test was based on the previous week's lecture material and the marks contributed towards 20% of the course mark. A condition for passing the course was that a student must pass at least six of the nine tests. The assessment promoted student involvement with the course – tutorial attendance was greater and more uniform than previously and exam performance improved significantly. Students recognised that the assessment system was useful in encouraging continuous learning over the semester and building confidence.
- 15 July 2008
- Published by WITPRESS LTD.
- p. 1-23
Vascular reconstruction: CFD predictions of bypass graft haemodynamics
Welcome to the WIT Press eLibrary - the home of the Transactions of the Wessex Institute collection, providing on-line access to papers presented at the Institute's prestigious international conferences and from its State-of-the-Art in Science & Engineering publications.
- 15 July 2008
- Published by WITPRESS LTD.
- p. 1-23
Vascular reconstruction: CFD predictions of bypass graft haemodynamics
Welcome to the WIT Press eLibrary - the home of the Transactions of the Wessex Institute collection, providing on-line access to papers presented at the Institute's prestigious international conferences and from its State-of-the-Art in Science & Engineering publications.
- 9 September 2002
- Published by Elsevier in Journal of Biomechanics
- Vol. 35 (10) , 1337-1346
Is there a haemodynamic advantage associated with cuffed arterial anastomoses?
- 9 September 2002
- Published by Elsevier in Journal of Biomechanics
- Vol. 35 (10) , 1337-1346
Is there a haemodynamic advantage associated with cuffed arterial anastomoses?
- 31 May 2002
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 24 (6) , 393-401
Numerical investigation of the haemodynamics at a patched arterial bypass anastomosis
Intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, incorporating a Taylor vein patch into the distal anastomosis of PTFE grafts, results in a decrease in intimal hyperplasia and improved patency rates. Numerical simulations of pulsatile, non-Newtonian blood flow through life-like femorodistal bypass models have been performed to determine whether haemodynamic benefits arise from the modified geometry of the Taylor anastomosis. In a conventional bypass, the distal anastomotic flow exhibited considerable spatial and temporal variations. Steep spatial gradients in the shearing force acted along the floor during systole. The effect of the Taylor geometry was to reduce gradually the momentum of the blood approaching the junction. Thus, flow disturbances were abated, undesirable flow separation at the toe was diminished, and a less adverse floor shear stress distribution prevailed in that case. Intimal thickening should be alleviated at the toe in the Taylor model where separation is reduced, and where the thrombogenic graft surface is replaced with a vein patch. Intimal hyperplasia on the floor may be inhibited in the Taylor model due to more favourable shear stresses. The improved flow through the patched anastomosis should contribute to its enhanced performance.
- 31 May 2002
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 24 (6) , 393-401
Numerical investigation of the haemodynamics at a patched arterial bypass anastomosis
Intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, incorporating a Taylor vein patch into the distal anastomosis of PTFE grafts, results in a decrease in intimal hyperplasia and improved patency rates. Numerical simulations of pulsatile, non-Newtonian blood flow through life-like femorodistal bypass models have been performed to determine whether haemodynamic benefits arise from the modified geometry of the Taylor anastomosis. In a conventional bypass, the distal anastomotic flow exhibited considerable spatial and temporal variations. Steep spatial gradients in the shearing force acted along the floor during systole. The effect of the Taylor geometry was to reduce gradually the momentum of the blood approaching the junction. Thus, flow disturbances were abated, undesirable flow separation at the toe was diminished, and a less adverse floor shear stress distribution prevailed in that case. Intimal thickening should be alleviated at the toe in the Taylor model where separation is reduced, and where the thrombogenic graft surface is replaced with a vein patch. Intimal hyperplasia on the floor may be inhibited in the Taylor model due to more favourable shear stresses. The improved flow through the patched anastomosis should contribute to its enhanced performance.