Delphine Périé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Delphine Périé has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Yvan Petit
Department of Mechanical Engineering, École de Technologie Supérieure, Montréal, Canada
2 shared publications A.J. Tate
Mechanical Engineering, Queen's University, Kingston, Canada
1 shared publicationC. Baunin
Service d'Imagerie Pédiatrique , CHU Purpan , Toulouse, France
1 shared publicationC. E. Aubin
Sainte-Justine Hospital
1 shared publicationC.E Aubin
1 shared publicationCarl-Eric Aubin
1 shared publication
Latest Publications
- 6 April 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (5) , 769-777
Correlating Material Properties with Tissue Composition in Enzymatically Digested Bovine Annulus Fibrosus and Nucleus Pulposus Tissue
Aging and degeneration of the intervertebral disk are accompanied by decreases in water and proteoglycan contents, and structural alterations. The aim of this study was to determine the impact of compositional changes on the material properties of intervertebral disk tissues. Confined compression stress-relaxation experiments were applied to bovine caudal annulus fibrosus and nucleus pulposus tissue specimens that were separated into three experimental groups: in situ, free-swelling control (PBS), and digestion (chondroitinase-ABC). Measurements of glycosaminoglycan (GAG) and water content, as well as nonlinear finite deformation biphasic theory and multiple linear regression analyses were performed. The compressive modulus H A0 and permeability k 0 of in situ specimens were 0.37±0.06 MPa and 0.49±0.08×10−15 m4 N−1 s−1 for nucleus, and 0.74±0.13 MPa and 0.42±0.05×10−15 m4 N−1 s−1 for annulus, respectively. There was a larger effect of swelling and digestion on the material properties and biochemical composition of nucleus pulposus than for annulus fibrosus. Alterations in proteoglycan and water content affected the compressive modulus and permeability, although the permeability was somewhat more strongly affected by water content than by proteoglycan content. Correlation coefficients r≤0.75 for the multiple regression indicated water and GAG content can moderately predict material properties, however other compositional and structural factors must be considered.
- 6 April 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (5) , 769-777
Correlating Material Properties with Tissue Composition in Enzymatically Digested Bovine Annulus Fibrosus and Nucleus Pulposus Tissue
Aging and degeneration of the intervertebral disk are accompanied by decreases in water and proteoglycan contents, and structural alterations. The aim of this study was to determine the impact of compositional changes on the material properties of intervertebral disk tissues. Confined compression stress-relaxation experiments were applied to bovine caudal annulus fibrosus and nucleus pulposus tissue specimens that were separated into three experimental groups: in situ, free-swelling control (PBS), and digestion (chondroitinase-ABC). Measurements of glycosaminoglycan (GAG) and water content, as well as nonlinear finite deformation biphasic theory and multiple linear regression analyses were performed. The compressive modulus H A0 and permeability k 0 of in situ specimens were 0.37±0.06 MPa and 0.49±0.08×10−15 m4 N−1 s−1 for nucleus, and 0.74±0.13 MPa and 0.42±0.05×10−15 m4 N−1 s−1 for annulus, respectively. There was a larger effect of swelling and digestion on the material properties and biochemical composition of nucleus pulposus than for annulus fibrosus. Alterations in proteoglycan and water content affected the compressive modulus and permeability, although the permeability was somewhat more strongly affected by water content than by proteoglycan content. Correlation coefficients r≤0.75 for the multiple regression indicated water and GAG content can moderately predict material properties, however other compositional and structural factors must be considered.
- 1 May 2004
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 42 (3) , 339-344
Biomechanical modelling of orthotic treatment of the scoliotic spine including a detailed representation of the brace-torso interface
As part of the development of new modelling tools for the simulation and design of brace treatment of scoliosis, a finite element model of a brace and its interface with the torso was proposed. The model was adapted to represent one scoliotic adolescent girl treated with a Boston brace. The 3D geometry was acquired using multiview radiographs. The model included the osseo-ligamentous structures, thoracic and abdominal soft tissues, brace foam and shell, and brace-torso interface. The simulations consisted of brace opening to include the patient's trunk followed by brace closing. To validate the model, the resulting geometry was compared with the real in-brace geometry, and the resulting contact reaction forces at the brace-torso interface were compared with the equivalent forces calculated from pressure measurements made on the in-brace patient. Differences between coronal equivalent and reaction forces were less than 7N. However, sagittal reaction forces (47N) were computed on the abdomen, whereas negligible equivalent forces were measured. The simulated geometry presented partially reduced coronal Cobb angles (1–40), over-corrected sagittal Cobb angles and maximum deformation plane (50), completely corrected coronal shift, and sagittal shift and rib humps that were not corrected. This study demonstrated the feasibility of a new approach that represents the load transfer from the brace to the spine more realistically than does the direct application of forces.
- 1 May 2004
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 42 (3) , 339-344
Biomechanical modelling of orthotic treatment of the scoliotic spine including a detailed representation of the brace-torso interface
As part of the development of new modelling tools for the simulation and design of brace treatment of scoliosis, a finite element model of a brace and its interface with the torso was proposed. The model was adapted to represent one scoliotic adolescent girl treated with a Boston brace. The 3D geometry was acquired using multiview radiographs. The model included the osseo-ligamentous structures, thoracic and abdominal soft tissues, brace foam and shell, and brace-torso interface. The simulations consisted of brace opening to include the patient's trunk followed by brace closing. To validate the model, the resulting geometry was compared with the real in-brace geometry, and the resulting contact reaction forces at the brace-torso interface were compared with the equivalent forces calculated from pressure measurements made on the in-brace patient. Differences between coronal equivalent and reaction forces were less than 7N. However, sagittal reaction forces (47N) were computed on the abdomen, whereas negligible equivalent forces were measured. The simulated geometry presented partially reduced coronal Cobb angles (1–40), over-corrected sagittal Cobb angles and maximum deformation plane (50), completely corrected coronal shift, and sagittal shift and rib humps that were not corrected. This study demonstrated the feasibility of a new approach that represents the load transfer from the brace to the spine more realistically than does the direct application of forces.
- 1 February 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (2) , 190-195
Personalized biomechanical simulations of orthotic treatment in idiopathic scoliosis
- 1 February 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (2) , 190-195
Personalized biomechanical simulations of orthotic treatment in idiopathic scoliosis
- 1 November 2003
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 21 (9) , 949-953
Correlation between nucleus zone migration within scoliotic intervertebral discs and mechanical properties distribution within scoliotic vertebrae
- 1 November 2003
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 21 (9) , 949-953
Correlation between nucleus zone migration within scoliotic intervertebral discs and mechanical properties distribution within scoliotic vertebrae
- 1 August 2003
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (15) , 1672-1677
Boston Brace Correction in Idiopathic Scoliosis: A Biomechanical Study
To analyze Boston brace biomechanics, pressure measurements and finite element simulations were done on 12 adolescent idiopathic scoliosis patients. The aim was to analyze the Boston brace effectiveness using a finite element model and experimental measurements. There are not very many biomechanical studies of Boston brace effectiveness, and its biomechanical action is not completely understood. This study was performed on 12 girls with scoliosis treated with the Boston brace system. The experimental protocol was composed of the acquisition of two sets of multiplanar radiographs with and without brace followed by the pressure acquisition at the brace-torso interface. A personalized finite element modeling of the trunk was generated from the 3D reconstruction of the patient's geometry. The brace treatment was simulated by the application of equivalent forces calculated from the pressure measurements. Two Boston brace force patterns were defined from the pressure measurements. The first one consisted of high right thoracic forces of 31-113 N, lumbar forces less than 47 N, and included a left thoracic extension working as a counter pad. The second one consisted of low thoracic forces less than 20 N, lumbar forces up to 70 N, without left thoracic extension. The simulations showed that the passive forces only produced a coronal Cobb angle correction up to 9 degrees, whereas real correction was up to 16 degrees. High thoracic pads reduced more effectively both thoracic and lumbar scoliotic curves than lumbar pads only. The study suggests that mechanisms other than brace pads produce correction and contribute to the force equilibrium within the brace.
- 1 August 2003
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (15) , 1672-1677
Boston Brace Correction in Idiopathic Scoliosis: A Biomechanical Study
To analyze Boston brace biomechanics, pressure measurements and finite element simulations were done on 12 adolescent idiopathic scoliosis patients. The aim was to analyze the Boston brace effectiveness using a finite element model and experimental measurements. There are not very many biomechanical studies of Boston brace effectiveness, and its biomechanical action is not completely understood. This study was performed on 12 girls with scoliosis treated with the Boston brace system. The experimental protocol was composed of the acquisition of two sets of multiplanar radiographs with and without brace followed by the pressure acquisition at the brace-torso interface. A personalized finite element modeling of the trunk was generated from the 3D reconstruction of the patient's geometry. The brace treatment was simulated by the application of equivalent forces calculated from the pressure measurements. Two Boston brace force patterns were defined from the pressure measurements. The first one consisted of high right thoracic forces of 31-113 N, lumbar forces less than 47 N, and included a left thoracic extension working as a counter pad. The second one consisted of low thoracic forces less than 20 N, lumbar forces up to 70 N, without left thoracic extension. The simulations showed that the passive forces only produced a coronal Cobb angle correction up to 9 degrees, whereas real correction was up to 16 degrees. High thoracic pads reduced more effectively both thoracic and lumbar scoliotic curves than lumbar pads only. The study suggests that mechanisms other than brace pads produce correction and contribute to the force equilibrium within the brace.
- 2 January 2002
- Published by Elsevier in Journal of Biomechanics
- Vol. 35 (2) , 293-297
Evaluation and calibration of an electromagnetic tracking device for biomechanical analysis of lifting tasks
- 2 January 2002
- Published by Elsevier in Journal of Biomechanics
- Vol. 35 (2) , 293-297
Evaluation and calibration of an electromagnetic tracking device for biomechanical analysis of lifting tasks
- 1 January 2002
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 5 (2) , 161-165
Personalised Mechanical Properties of Scoliotic Vertebrae Determined In Vivo Using Tomodensitometry
This in vivo study investigated the mechanical properties of apical scoliotic vertebrae using computed tomography (CT) and finite element (FE) meshing. CT examination was performed on seven scoliotic girls. FE meshing of each vertebral body allowed automatic mapping of the CT scan and the visualisation of the bone density distribution. Centroids and mass centres were compared to analyse the mechanical properties distribution. Compared to the centroid, the mass centre migrated into the concavity of the curvature. The three vertebrae of a same patient had the same body migration behaviour because they were located at the curvature apex. This observation was verified in the coronal plane, but not in the sagittal plane. These results represent new data over few geometrical analyses of scoliotic vertebrae. Same in vivo personalisation of mechanical properties should be performed on intervertebral discs or ligaments to personalise stiffness properties of the spine for the biomechanical modelling of human torso. Moreover, do this mechanical deformation of scoliotic vertebrae, that appears before the vertebral wedging, could be a predictive tool in scoliosis treatment?
- 1 January 2002
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 5 (2) , 161-165
Personalised Mechanical Properties of Scoliotic Vertebrae Determined In Vivo Using Tomodensitometry
This in vivo study investigated the mechanical properties of apical scoliotic vertebrae using computed tomography (CT) and finite element (FE) meshing. CT examination was performed on seven scoliotic girls. FE meshing of each vertebral body allowed automatic mapping of the CT scan and the visualisation of the bone density distribution. Centroids and mass centres were compared to analyse the mechanical properties distribution. Compared to the centroid, the mass centre migrated into the concavity of the curvature. The three vertebrae of a same patient had the same body migration behaviour because they were located at the curvature apex. This observation was verified in the coronal plane, but not in the sagittal plane. These results represent new data over few geometrical analyses of scoliotic vertebrae. Same in vivo personalisation of mechanical properties should be performed on intervertebral discs or ligaments to personalise stiffness properties of the spine for the biomechanical modelling of human torso. Moreover, do this mechanical deformation of scoliotic vertebrae, that appears before the vertebral wedging, could be a predictive tool in scoliosis treatment?
- 1 November 2001
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 19 (9) , 1245-1248
Intervertebral disc modeling using a MRI method: Migration of the nucleus zone within scoliotic intervertebral discs
- 1 November 2001
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 19 (9) , 1245-1248
Intervertebral disc modeling using a MRI method: Migration of the nucleus zone within scoliotic intervertebral discs