Rafat R. Ansari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rafat R. Ansari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Luigi Rovati
Department of Engineering “Enzo Ferrari”, University of Modena and Reggio Emilia, Via P. Vivarelli, 10, 41125 Modena, Italy
4 shared publications Stefan Boeckle
Univ. degli Studi di Brescia (Italy)
2 shared publications- Luca Pollonini
University of Houston, Department of Engineering Technology, Houston, Texas, United States
1 shared publication - Manuel B. Datiles
National Eye Institute, National Institutes of Health, Bethesda, Maryland
1 shared publication Stefan Böckle
Ohio Aerospace Institute, Glenn Research Center, National Aeronautics and Space Administration, Mail Stop 333-1, 21000 Brookpark Road, Cleveland, Ohio 44135
1 shared publication
Latest Publications
- Open Access
- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (1) , 103-115
New optical scheme for a polarimetric-based glucose sensor
A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient’s eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. © 2004 Society of Photo-Optical Instrumentation Engineers.
- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (1) , 103-115
Open AccessNew optical scheme for a polarimetric-based glucose sensor
A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient’s eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. © 2004 Society of Photo-Optical Instrumentation Engineers.
- 11 October 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5143, 114-126
Polarimetric glucose sensing using Brewster reflection applying a rotating retarder analyzer
Previously, we proposed a polarimetric method, that exploits the Brewster-reflection with the final goal of application to the human eye (reflection off the eye lens) for non-invasive glucose sensing. The linearly polarized reflected light of this optical scheme is rotated by the glucose molecules present in the aqueous humor, thus carries the blood glucose concentration information. A proof-of-concept experimental bench-top setup is presented, applying a multi-wavelength true phase measurement approach and a rotating phase retarder as an analyzer to measure the very small rotation angles and the complete polarization state of the measurement light.
- 11 October 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5143, 114-126
Polarimetric glucose sensing using Brewster reflection applying a rotating retarder analyzer
Previously, we proposed a polarimetric method, that exploits the Brewster-reflection with the final goal of application to the human eye (reflection off the eye lens) for non-invasive glucose sensing. The linearly polarized reflected light of this optical scheme is rotated by the glucose molecules present in the aqueous humor, thus carries the blood glucose concentration information. A proof-of-concept experimental bench-top setup is presented, applying a multi-wavelength true phase measurement approach and a rotating phase retarder as an analyzer to measure the very small rotation angles and the complete polarization state of the measurement light.
- 24 October 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4434, 263-268
Dynamic light scattering and natural fluorescence measurements of the corneal tissue
Dynamic light scattering (DLS) and autofluorescence (AF) are non-invasive diagnostic techniques that can monitor changes at the molecular level in ocular tissues. In the present study, we demonstrate as simultaneous measurements of autofluorescence and dynamic light scattering on the corneal tissues can be performed using a novel specifically designed instrument. The integrated instrument takes advantage of the singular techniques by improving the measurement quality and the reliability of the diagnosis. Preliminary tests on volunteers show promise in relation to possible use in the clinical practice.
- 24 October 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4434, 263-268
Dynamic light scattering and natural fluorescence measurements of the corneal tissue
Dynamic light scattering (DLS) and autofluorescence (AF) are non-invasive diagnostic techniques that can monitor changes at the molecular level in ocular tissues. In the present study, we demonstrate as simultaneous measurements of autofluorescence and dynamic light scattering on the corneal tissues can be performed using a novel specifically designed instrument. The integrated instrument takes advantage of the singular techniques by improving the measurement quality and the reliability of the diagnosis. Preliminary tests on volunteers show promise in relation to possible use in the clinical practice.
- 24 October 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4434, 260-263
Development of a novel noninvasive sensor for determination of blood glucose concentration
Optical methods represent the most promising techniques to perform non-invasive glucose detection. Glucose concentration in the aqueous humor closely mimics glucose levels in the blood and therefore non-invasive optical measurement of glucose can be performed by an optical beam crossing the eye anterior chamber. We propose a polarimetric method that exploits the Brewster-reflection of circularly polarized light on the lens of the eye. After reflection, the resulting linearly polarized light is subject to rotation by the glucose in the aqueous humor and thus carries the concentration information. A preliminary experimental setup, using glucose samples in a beaker, was realized and investigated.
- 24 October 2001
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4434, 260-263
Development of a novel noninvasive sensor for determination of blood glucose concentration
Optical methods represent the most promising techniques to perform non-invasive glucose detection. Glucose concentration in the aqueous humor closely mimics glucose levels in the blood and therefore non-invasive optical measurement of glucose can be performed by an optical beam crossing the eye anterior chamber. We propose a polarimetric method that exploits the Brewster-reflection of circularly polarized light on the lens of the eye. After reflection, the resulting linearly polarized light is subject to rotation by the glucose in the aqueous humor and thus carries the concentration information. A preliminary experimental setup, using glucose samples in a beaker, was realized and investigated.
- 1 June 1999
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 1 (2) , 159-168
Use of Dynamic Light Scattering and Scheimpflug Imaging for the Early Detection of Cataracts
Cataract is a leading cause of blindness. Diabetes and glycemic conditions enhance the chances of developing cataracts early. At clinical stage cataracts are detected and documented by slit-lamp biomicroscopy and Scheimpflug photography. A compact fiber optic probe, developed for space experiments, was mounted on a Scheimpflug imaging system. The probe detects and documents cataracts at pre-clinical stage noninvasively and quantitatively. The early detection at the molecular level may lead to medical treatment of cataracts, better control of glycemia, and diabetes mellitus.
- 1 June 1999
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 1 (2) , 159-168
Use of Dynamic Light Scattering and Scheimpflug Imaging for the Early Detection of Cataracts
Cataract is a leading cause of blindness. Diabetes and glycemic conditions enhance the chances of developing cataracts early. At clinical stage cataracts are detected and documented by slit-lamp biomicroscopy and Scheimpflug photography. A compact fiber optic probe, developed for space experiments, was mounted on a Scheimpflug imaging system. The probe detects and documents cataracts at pre-clinical stage noninvasively and quantitatively. The early detection at the molecular level may lead to medical treatment of cataracts, better control of glycemia, and diabetes mellitus.