Yuan-Chuan Tai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuan-Chuan Tai has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Sergey Komarov
Washington University in St Louis, MO 63110, USA
4 shared publicationsHeyu Wu
Department of Radiology, Washington University School of Medicine, St. Louis, MO, USA
3 shared publicationsJie Wen
Washington University in St Louis, MO 63110, USA
2 shared publicationsKe Li
Washington University in St Louis, MO 63110, USA
2 shared publicationsAlfred Garson
Department of Physics, Washington University, Saint Louis, St. Louis, MO, USA
1 shared publicationAndrew W. O׳Sullivan
Washington University in St Louis, MO 63110, USA
1 shared publication
Latest Publications
- 1 September 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 794, 151-159
A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications
- 1 September 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 794, 151-159
A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications
- Open Access
A dedicated high resolution PET imager for plant sciences
PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules: 84 microPET R4 block detectors with 2.2 mm crystals to provide a large detecting area; and 32 Inveon block detectors with 1.5 mm crystals to provide higher spatial resolution. Outputs of the four microPET block detectors in a modular housing are concatenated by a custom printed circuit board to match the output characteristics of an Inveon detector. All the detectors are read out by QuickSilver electronics. The detector modules are configured to full rings with a 15 cm diameter trans-axial field of view (FOV) for dynamic tomographic imaging of small plants. Potentially, the Inveon detectors can be reconfigured to quarter-rings to get a 25 cm FOV using step-and-shoot motion. The imager contains 2 linear stages to position detectors at different heights for multi-bed scanning, and 2 rotation stages to collect coincidence events from all angles. The PET system has been built and integrated into the PGC. The system has a typical energy resolution of 15% for Inveon blocks and 24% for R4 blocks; timing resolution of 1.8 ns; and sensitivity of 1.3%,1.4%,3.0% measured at center of FOV, 5 cm off to R4 half-ring and 5 cm off to Inveon half-ring, respectively(with a 350-650 KeV energy and 3.1 ns timing window). System spatial resolution is similar to that of commercial microPET sytems, with 1.25 mm rod sources in the micro-Derenzo phantom resolved using ML-EM algorithm. Preliminary imaging experiments using different plants labeled with 11C-CO2 produced high-quality dynamic PET images.
Open AccessA dedicated high resolution PET imager for plant sciences
PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules: 84 microPET R4 block detectors with 2.2 mm crystals to provide a large detecting area; and 32 Inveon block detectors with 1.5 mm crystals to provide higher spatial resolution. Outputs of the four microPET block detectors in a modular housing are concatenated by a custom printed circuit board to match the output characteristics of an Inveon detector. All the detectors are read out by QuickSilver electronics. The detector modules are configured to full rings with a 15 cm diameter trans-axial field of view (FOV) for dynamic tomographic imaging of small plants. Potentially, the Inveon detectors can be reconfigured to quarter-rings to get a 25 cm FOV using step-and-shoot motion. The imager contains 2 linear stages to position detectors at different heights for multi-bed scanning, and 2 rotation stages to collect coincidence events from all angles. The PET system has been built and integrated into the PGC. The system has a typical energy resolution of 15% for Inveon blocks and 24% for R4 blocks; timing resolution of 1.8 ns; and sensitivity of 1.3%,1.4%,3.0% measured at center of FOV, 5 cm off to R4 half-ring and 5 cm off to Inveon half-ring, respectively(with a 350-650 KeV energy and 3.1 ns timing window). System spatial resolution is similar to that of commercial microPET sytems, with 1.25 mm rod sources in the micro-Derenzo phantom resolved using ML-EM algorithm. Preliminary imaging experiments using different plants labeled with 11C-CO2 produced high-quality dynamic PET images.
- 17 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (1) , 9-15
3-D Spatial Resolution of 350 $\mu$m Pitch Pixelated CdZnTe Detectors for Imaging Applications
We are currently investigating the feasibility of using highly pixelated Cadmium Zinc Telluride (CdZnTe) detectors for sub-500 μm resolution PET imaging applications. A 20 mm × 20 mm × 5 mm CdZnTe substrate was fabricated with 350 μm pitch pixels (250 μm anode pixels with 100 μm gap) and coplanar cathode. Charge sharing among the pixels of a 350 μm pitch detector was studied using collimated 122 keV and 511 keV gamma ray sources. For a 350 μm pitch CdZnTe detector, scatter plots of the charge signal of two neighboring pixels clearly show more charge sharing when the collimated beam hits the gap between adjacent pixels. Using collimated Co-57 and Ge-68 sources, we measured the count profiles and estimated the intrinsic spatial resolution of 350 μm pitch detector biased at -1000 V. Depth of interaction was analyzed based on two methods, i.e., cathode/anode ratio and electron drift time, in both 122 keV and 511 keV measurements. For single-pixel photopeak events, a linear correlation between cathode/anode ratio and electron drift time was shown, which would be useful for estimating the DOI information and preserving image resolution in CdZnTe PET imaging applications.
- 17 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (1) , 9-15
3-D Spatial Resolution of 350 $\mu$m Pitch Pixelated CdZnTe Detectors for Imaging Applications
We are currently investigating the feasibility of using highly pixelated Cadmium Zinc Telluride (CdZnTe) detectors for sub-500 μm resolution PET imaging applications. A 20 mm × 20 mm × 5 mm CdZnTe substrate was fabricated with 350 μm pitch pixels (250 μm anode pixels with 100 μm gap) and coplanar cathode. Charge sharing among the pixels of a 350 μm pitch detector was studied using collimated 122 keV and 511 keV gamma ray sources. For a 350 μm pitch CdZnTe detector, scatter plots of the charge signal of two neighboring pixels clearly show more charge sharing when the collimated beam hits the gap between adjacent pixels. Using collimated Co-57 and Ge-68 sources, we measured the count profiles and estimated the intrinsic spatial resolution of 350 μm pitch detector biased at -1000 V. Depth of interaction was analyzed based on two methods, i.e., cathode/anode ratio and electron drift time, in both 122 keV and 511 keV measurements. For single-pixel photopeak events, a linear correlation between cathode/anode ratio and electron drift time was shown, which would be useful for estimating the DOI information and preserving image resolution in CdZnTe PET imaging applications.
- 11 April 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (9) , 2517-2538
Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems
Virtual-pinhole PET (VP-PET) imaging is a new technology in which one or more high-resolution detector modules are integrated into a conventional PET scanner with lower resolution detectors. It can locally enhance the spatial resolution and contrast recovery near the add-on detectors, and depending on the configuration, may also increase the sensitivity of the system. This novel scanner geometry makes the reconstruction problem more challenging compared to the reconstruction of data from a stand-alone PET scanner, as new techniques are needed to model and account for the non-standard acquisition. In this paper, we present a general framework for fully 3D modeling of an arbitrary VP-PET insert system. The model components are incorporated into a statistical reconstruction algorithm to estimate an image from the multi-resolution data. For validation, we apply the proposed model and reconstruction approach to one of our custom-built VP-PET systems-a half-ring insert device integrated into a clinical PET/CT scanner. Details regarding the most important implementation issues are provided. We show that the proposed data model is consistent with the measured data, and that our approach can lead to reconstructions with improved spatial resolution and lesion detectability.
- 11 April 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (9) , 2517-2538
Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems
Virtual-pinhole PET (VP-PET) imaging is a new technology in which one or more high-resolution detector modules are integrated into a conventional PET scanner with lower resolution detectors. It can locally enhance the spatial resolution and contrast recovery near the add-on detectors, and depending on the configuration, may also increase the sensitivity of the system. This novel scanner geometry makes the reconstruction problem more challenging compared to the reconstruction of data from a stand-alone PET scanner, as new techniques are needed to model and account for the non-standard acquisition. In this paper, we present a general framework for fully 3D modeling of an arbitrary VP-PET insert system. The model components are incorporated into a statistical reconstruction algorithm to estimate an image from the multi-resolution data. For validation, we apply the proposed model and reconstruction approach to one of our custom-built VP-PET systems-a half-ring insert device integrated into a clinical PET/CT scanner. Details regarding the most important implementation issues are provided. We show that the proposed data model is consistent with the measured data, and that our approach can lead to reconstructions with improved spatial resolution and lesion detectability.
- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2148-2154
Parallel Beam Approximation for Calculation of Detection Efficiency of Crystals in PET Detector Arrays
In this work we propose a parallel beam approximation for the computation of the detection efficiency of crystals in a PET detector array. In this approximation the detection efficiency of a crystal is estimated using the distance between source and the crystal and the pre-calculated detection cross section of the crystal in a crystal array which is calculated for a uniform parallel beam of gammas. The pre-calculated detection cross sections for a few representative incident angles and gamma energies can be used to create a look-up table to be used in simulation studies or practical implementation of scatter or random correction algorithms. Utilizing the symmetries of the square crystal array, the pre-calculated look-up tables can be relatively small. The detection cross sections can be measured experimentally, calculated analytically or simulated using a Monte Carlo (MC) approach. In this work we used a MC simulation that takes into account the energy windowing, Compton scattering and factors in the “block effect”. The parallel beam approximation was validated by a separate MC simulation using point sources located at different positions around a crystal array. Experimentally measured detection efficiencies were compared with Monte Carlo simulated detection efficiencies. Results suggest that the parallel beam approximation provides an efficient and accurate way to compute the crystal detection efficiency, which can be used for estimation of random and scatter coincidences for PET data corrections.
- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2148-2154
Parallel Beam Approximation for Calculation of Detection Efficiency of Crystals in PET Detector Arrays
In this work we propose a parallel beam approximation for the computation of the detection efficiency of crystals in a PET detector array. In this approximation the detection efficiency of a crystal is estimated using the distance between source and the crystal and the pre-calculated detection cross section of the crystal in a crystal array which is calculated for a uniform parallel beam of gammas. The pre-calculated detection cross sections for a few representative incident angles and gamma energies can be used to create a look-up table to be used in simulation studies or practical implementation of scatter or random correction algorithms. Utilizing the symmetries of the square crystal array, the pre-calculated look-up tables can be relatively small. The detection cross sections can be measured experimentally, calculated analytically or simulated using a Monte Carlo (MC) approach. In this work we used a MC simulation that takes into account the energy windowing, Compton scattering and factors in the “block effect”. The parallel beam approximation was validated by a separate MC simulation using point sources located at different positions around a crystal array. Experimentally measured detection efficiencies were compared with Monte Carlo simulated detection efficiencies. Results suggest that the parallel beam approximation provides an efficient and accurate way to compute the crystal detection efficiency, which can be used for estimation of random and scatter coincidences for PET data corrections.
- 1 March 2007
- Vol. 48 (3) , 420-8
18F-fluoroacetate: a potential acetate analog for prostate tumor imaging--in vivo evaluation of 18F-fluoroacetate versus 11C-acetate.
PET with (11)C-acetate ((11)C-ACE) has a high sensitivity for detection of prostate cancer and several other cancers that are poorly detected with (18)F-FDG. However, the short half-life (20.4 min) of (11)C limits the general availability of (11)C-ACE. (18)F-Fluoroacetate ((18)F-FAC) is an analog of acetate with a longer radioactive half-life ((18)F = 110 min). This study was undertaken to assess the potential usefulness of (18)F-FAC as a prostate tumor imaging agent. We developed an efficient radiosynthesis for (18)F-FAC, which has already been adapted to a commercial synthesizer. Biodistribution studies of (18)F-FAC were compared with (11)C-ACE in normal Sprague-Dawley male rats and CWR22 tumor-bearing nu/nu mice. We also performed a small-animal PET study of (18)F-FAC in CWR22 tumor-bearing nu/nu mice and a whole-body PET study in a baboon to examine defluorination. We obtained (18)F-FAC in a radiochemical yield of 55% +/- 5% (mean +/- SD) in approximately 35 min and with a radiochemical purity of >99%. Rat biodistribution showed extensive defluorination, which was not observed in the baboon PET, as indicated by the standardized uptake values (SUVs) (SUVs of iliac bones and femurs were 0.26 and 0.3 at 1 h and 0.22 and 0.4 at 2 h, respectively). CWR22 tumor-bearing nu/nu mice showed tumor uptake (mean +/- SD) of 0.78 +/- 0.06 %ID/g (injected dose per gram of tissue) for (11)C-ACE versus 4.01 +/- 0.32 %ID/g for (18)F-FAC. For most organs-except blood, muscle, and fat-the tumor-to-organ ratios at 30 min after injection were higher with (18)F-FAC, whereas the tumor-to-heart and tumor-to-prostate ratios were similar. All of these data indicate that (18)F-FAC may be a useful alternative to (11)C-ACE tracer for the detection of prostate tumors by PET.
- 1 March 2007
- Vol. 48 (3) , 420-8
18F-fluoroacetate: a potential acetate analog for prostate tumor imaging--in vivo evaluation of 18F-fluoroacetate versus 11C-acetate.
PET with (11)C-acetate ((11)C-ACE) has a high sensitivity for detection of prostate cancer and several other cancers that are poorly detected with (18)F-FDG. However, the short half-life (20.4 min) of (11)C limits the general availability of (11)C-ACE. (18)F-Fluoroacetate ((18)F-FAC) is an analog of acetate with a longer radioactive half-life ((18)F = 110 min). This study was undertaken to assess the potential usefulness of (18)F-FAC as a prostate tumor imaging agent. We developed an efficient radiosynthesis for (18)F-FAC, which has already been adapted to a commercial synthesizer. Biodistribution studies of (18)F-FAC were compared with (11)C-ACE in normal Sprague-Dawley male rats and CWR22 tumor-bearing nu/nu mice. We also performed a small-animal PET study of (18)F-FAC in CWR22 tumor-bearing nu/nu mice and a whole-body PET study in a baboon to examine defluorination. We obtained (18)F-FAC in a radiochemical yield of 55% +/- 5% (mean +/- SD) in approximately 35 min and with a radiochemical purity of >99%. Rat biodistribution showed extensive defluorination, which was not observed in the baboon PET, as indicated by the standardized uptake values (SUVs) (SUVs of iliac bones and femurs were 0.26 and 0.3 at 1 h and 0.22 and 0.4 at 2 h, respectively). CWR22 tumor-bearing nu/nu mice showed tumor uptake (mean +/- SD) of 0.78 +/- 0.06 %ID/g (injected dose per gram of tissue) for (11)C-ACE versus 4.01 +/- 0.32 %ID/g for (18)F-FAC. For most organs-except blood, muscle, and fat-the tumor-to-organ ratios at 30 min after injection were higher with (18)F-FAC, whereas the tumor-to-heart and tumor-to-prostate ratios were similar. All of these data indicate that (18)F-FAC may be a useful alternative to (11)C-ACE tracer for the detection of prostate tumors by PET.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1711-1714
Generalized 3D Kernel Computation Method and Its Application in PET-Insert System
We are developing insert devices for existing PET scanners to improve the image resolution with almost the same sensitivity as current PET scanners. The insert device can be used to zoom into a particular organ of interest. Introduction of the insert inside the scanner leads to three types of coincidences: insert-insert (II), insert-scanner (IS) and scanner-scanner (SS). In typical whole-body PET scanners, coincidences recorded in the scanner are sorted into parallel-beam sinograms and images are reconstructed using linear or iterative techniques. In the PET-insert system, the coincidences of type IS have an inherent fan-beam geometry. Reconstruction using parallel-beam sinograms introduces severe streaking artifacts in the images. The coincidences sorted into fan-beam sinograms reduce the artifacts in the reconstructed images. The approach to compute the kernel was derived from CT as there exists an analogy between the PET-insert geometry and a fourth generation CT scanner geometry. In this approach, the weights in the kernel are computed using the intersection of a cone with a voxel. We previously developed two dimensional reconstruction algorithms for this novel system geometry. We extend this work to three dimensions in this paper. A maximum-likelihood expectation-maximization algorithm was used to reconstruct the data. The kernel was validated with a contrast recovery study using a digital phantom. Images reconstructed from experimental data show good quality without any visible artifacts.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1711-1714
Generalized 3D Kernel Computation Method and Its Application in PET-Insert System
We are developing insert devices for existing PET scanners to improve the image resolution with almost the same sensitivity as current PET scanners. The insert device can be used to zoom into a particular organ of interest. Introduction of the insert inside the scanner leads to three types of coincidences: insert-insert (II), insert-scanner (IS) and scanner-scanner (SS). In typical whole-body PET scanners, coincidences recorded in the scanner are sorted into parallel-beam sinograms and images are reconstructed using linear or iterative techniques. In the PET-insert system, the coincidences of type IS have an inherent fan-beam geometry. Reconstruction using parallel-beam sinograms introduces severe streaking artifacts in the images. The coincidences sorted into fan-beam sinograms reduce the artifacts in the reconstructed images. The approach to compute the kernel was derived from CT as there exists an analogy between the PET-insert geometry and a fourth generation CT scanner geometry. In this approach, the weights in the kernel are computed using the intersection of a cone with a voxel. We previously developed two dimensional reconstruction algorithms for this novel system geometry. We extend this work to three dimensions in this paper. A maximum-likelihood expectation-maximization algorithm was used to reconstruct the data. The kernel was validated with a contrast recovery study using a digital phantom. Images reconstructed from experimental data show good quality without any visible artifacts.
- 15 August 2005
- Published by Annual Reviews in Annual Review of Biomedical Engineering
- Vol. 7 (1) , 255-285
Instrumentation Aspects of Animal PET
▪ Abstract Biological research has been accelerated by the development of noninvasive imaging techniques and by use of genetically engineered mice to model human diseases and normal development. Because these mice can be expensive, noninvasive imaging techniques, such as high-resolution positron emission tomography (PET), that permit longitudinal studies of the same animals are very attractive. Such studies reduce the number of animals used, reduce intersubject variability, and improve the accuracy of biological models. PET provides quantitative measurements of the spatiotemporal distribution of radiotracers and is an extremely powerful tool in using molecular imaging to study biology, to monitor disease intervention, and to establish pharmacokinetics for new drugs. The design of animal PET scanners has improved significantly in the past decade and can provide adequate image resolution and sensitivity to study transgenic mice. This article reviews the fundamental and technical challenges of small-animal PET imaging, with a particular focus on the latest developments and future directions of detector technologies and system design.
- 15 August 2005
- Published by Annual Reviews in Annual Review of Biomedical Engineering
- Vol. 7 (1) , 255-285
Instrumentation Aspects of Animal PET
▪ Abstract Biological research has been accelerated by the development of noninvasive imaging techniques and by use of genetically engineered mice to model human diseases and normal development. Because these mice can be expensive, noninvasive imaging techniques, such as high-resolution positron emission tomography (PET), that permit longitudinal studies of the same animals are very attractive. Such studies reduce the number of animals used, reduce intersubject variability, and improve the accuracy of biological models. PET provides quantitative measurements of the spatiotemporal distribution of radiotracers and is an extremely powerful tool in using molecular imaging to study biology, to monitor disease intervention, and to establish pharmacokinetics for new drugs. The design of animal PET scanners has improved significantly in the past decade and can provide adequate image resolution and sensitivity to study transgenic mice. This article reviews the fundamental and technical challenges of small-animal PET imaging, with a particular focus on the latest developments and future directions of detector technologies and system design.