Laurent Brochard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurent Brochard has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
Jordi Mancebo
Intensive Care Medicine Unit Hospital Sant PauBarcelona
6 shared publications- Francois Lemaire
Service de Réanimation Médicale, Hôpital Henri Mondor, Créteil, France
4 shared publications - Salvatore Maurizio Maggiore
Department of Innovative Technologies in Medicine and Dentistry, Gabriele d'Annunzio University of Chieti-Pescara, Chieti, Italy
4 shared publications Christian Brun-Buisson
University Hospital Henri Mondor
3 shared publicationsMarco Ranieri
Università di Torino
3 shared publicationsMartin Tobin
Division of Pulmonary and Critical Care Medicine, Edward Hines Jr, Veterans Affairs Hospital and Loyola University of Chicago Stritch School of Medicine, Hines, USA
3 shared publications
Latest Publications
- 14 December 2011
- Vol. 7 (321) , 2444-51
[When the heart and/or the lung fails: the ECMO].
The Extra corporeal membrane oxygenation (ECMO) was initially proposed as a technique of respiratory support using an external membrane oxygenator. With time, it has also become a technique of cardiorespiratory support to ensure both gas exchange and organ perfusion until the restoration of organs function. This technical assistance can be central or peripheral and provides a partial or total circulatory support. The circuit includes a non occlusive centrifugal pump, an oxygenator for an enrichment of O2 and elimination of CO2 and cannulas for drainage and re-injection. Recently, the establishment of such assistance became possible percutaneously, allowing it to be initiated at the intensive care bedside or even before in-hospital admission.
- 14 December 2011
- Vol. 7 (321) , 2444-51
[When the heart and/or the lung fails: the ECMO].
The Extra corporeal membrane oxygenation (ECMO) was initially proposed as a technique of respiratory support using an external membrane oxygenator. With time, it has also become a technique of cardiorespiratory support to ensure both gas exchange and organ perfusion until the restoration of organs function. This technical assistance can be central or peripheral and provides a partial or total circulatory support. The circuit includes a non occlusive centrifugal pump, an oxygenator for an enrichment of O2 and elimination of CO2 and cannulas for drainage and re-injection. Recently, the establishment of such assistance became possible percutaneously, allowing it to be initiated at the intensive care bedside or even before in-hospital admission.
- 29 February 2008
- Published by Elsevier in Réanimation
- Vol. 17 (1) , 36-41
La réparation alvéolaire est-elle responsable des modifications de mécanique respiratoire observées au cours du SDRA ?
- 29 February 2008
- Published by Elsevier in Réanimation
- Vol. 17 (1) , 36-41
La réparation alvéolaire est-elle responsable des modifications de mécanique respiratoire observées au cours du SDRA ?
- 30 November 2006
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 30 (8) , 392-395
Calidad del sueño de pacientes ventilados: ¿es importante el modo ventilatorio o su reglaje?
- 30 November 2006
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 30 (8) , 392-395
Calidad del sueño de pacientes ventilados: ¿es importante el modo ventilatorio o su reglaje?
- 15 October 2006
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 174 (8) , 894-900
A Multicenter Randomized Trial of Computer-driven Protocolized Weaning from Mechanical Ventilation
Rationale and Objectives: Duration of weaning from mechanical ventilation may be reduced by the use of a systematic approach. We assessed whether a closed-loop knowledge-based algorithm introduced in a ventilator to act as a computer-driven weaning protocol can improve patient outcomes as compared with usual care. Methods and Measurements: We conducted a multicenter randomized controlled study with concealed allocation to compare usual care for weaning with computer-driven weaning. The computerized protocol included an automatic gradual reduction in pressure support, automatic performance of spontaneous breathing trials (SBT), and generation of an incentive message when an SBT was successfully passed. One hundred forty-four patients were enrolled before weaning initiation. They were randomly allocated to computer-driven weaning or to physician-controlled weaning according to local guidelines. Weaning duration until successful extubation and total duration of ventilation were the primary endpoints. Main Results: Weaning duration was reduced in the computer-driven group from a median of 5 to 3 d (p = 0.01) and total duration of mechanical ventilation from 12 to 7.5 d (p = 0.003). Reintubation rate did not differ (23 vs. 16%, p = 0.40). Computer-driven weaning also decreased median intensive care unit (ICU) stay duration from 15.5 to 12 d (p = 0.02) and caused no adverse events. The amount of sedation did not differ between groups. In the usual care group, compliance to recommended modes and to SBT was estimated, respectively, at 96 and 51%. Conclusions: The specific computer-driven system used in this study can reduce mechanical ventilation duration and ICU length of stay, as compared with a physician-controlled weaning process.
- 15 October 2006
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 174 (8) , 894-900
A Multicenter Randomized Trial of Computer-driven Protocolized Weaning from Mechanical Ventilation
Rationale and Objectives: Duration of weaning from mechanical ventilation may be reduced by the use of a systematic approach. We assessed whether a closed-loop knowledge-based algorithm introduced in a ventilator to act as a computer-driven weaning protocol can improve patient outcomes as compared with usual care. Methods and Measurements: We conducted a multicenter randomized controlled study with concealed allocation to compare usual care for weaning with computer-driven weaning. The computerized protocol included an automatic gradual reduction in pressure support, automatic performance of spontaneous breathing trials (SBT), and generation of an incentive message when an SBT was successfully passed. One hundred forty-four patients were enrolled before weaning initiation. They were randomly allocated to computer-driven weaning or to physician-controlled weaning according to local guidelines. Weaning duration until successful extubation and total duration of ventilation were the primary endpoints. Main Results: Weaning duration was reduced in the computer-driven group from a median of 5 to 3 d (p = 0.01) and total duration of mechanical ventilation from 12 to 7.5 d (p = 0.003). Reintubation rate did not differ (23 vs. 16%, p = 0.40). Computer-driven weaning also decreased median intensive care unit (ICU) stay duration from 15.5 to 12 d (p = 0.02) and caused no adverse events. The amount of sedation did not differ between groups. In the usual care group, compliance to recommended modes and to SBT was estimated, respectively, at 96 and 51%. Conclusions: The specific computer-driven system used in this study can reduce mechanical ventilation duration and ICU length of stay, as compared with a physician-controlled weaning process.
- 23 May 2006
- Published by Springer Nature in Intensive Care Medicine
- Vol. 32 (7) , 1014-1021
Under-humidification and over-humidification during moderate induced hypothermia with usual devices
In mechanically ventilated patients with induced hypothermia, the efficacy of heat and moisture exchangers and heated humidifiers to adequately humidify the airway is poorly known. The aim of the study was to assess the efficacy of different humidification devices during moderate hypothermia. Prospective, cross-over randomized study. Medical Intensive Care Unit in a University Hospital. Nine adult patients hospitalized after cardiac arrest in whom moderate hypothermia was induced (33°C for 24 h). Patients were ventilated at admission (period designated “normothermia”) with a heat and moisture exchanger, and were randomly ventilated during hypothermia with a heat and moisture exchanger, a heated humidifier, and an active heat and moisture exchanger. Core temperature, inspired and expired gas absolute and relative humidity were measured. Each system demonstrated limitations in its ability to humidify gases in the specific situation of hypothermia. Performances of heat and moisture exchangers were closely correlated to core temperature (r 2 = 0.84). During hypothermia, heat and moisture exchangers led to major under-humidification, with absolute humidity below 25 mgH2O/l. The active heat and moisture exchanger slightly improved humidification. Heated humidifiers were mostly adequate but led to over-humidification in some patients, with inspiratory absolute humidity higher than maximal water content at 33°C with a positive balance between inspiratory and expiratory water content. These results suggest that in the case of moderate hypothermia, heat and moisture exchangers should be used cautiously and that heated humidifiers may lead to over-humidification with the currently recommended settings.
- 23 May 2006
- Published by Springer Nature in Intensive Care Medicine
- Vol. 32 (7) , 1014-1021
Under-humidification and over-humidification during moderate induced hypothermia with usual devices
In mechanically ventilated patients with induced hypothermia, the efficacy of heat and moisture exchangers and heated humidifiers to adequately humidify the airway is poorly known. The aim of the study was to assess the efficacy of different humidification devices during moderate hypothermia. Prospective, cross-over randomized study. Medical Intensive Care Unit in a University Hospital. Nine adult patients hospitalized after cardiac arrest in whom moderate hypothermia was induced (33°C for 24 h). Patients were ventilated at admission (period designated “normothermia”) with a heat and moisture exchanger, and were randomly ventilated during hypothermia with a heat and moisture exchanger, a heated humidifier, and an active heat and moisture exchanger. Core temperature, inspired and expired gas absolute and relative humidity were measured. Each system demonstrated limitations in its ability to humidify gases in the specific situation of hypothermia. Performances of heat and moisture exchangers were closely correlated to core temperature (r 2 = 0.84). During hypothermia, heat and moisture exchangers led to major under-humidification, with absolute humidity below 25 mgH2O/l. The active heat and moisture exchanger slightly improved humidification. Heated humidifiers were mostly adequate but led to over-humidification in some patients, with inspiratory absolute humidity higher than maximal water content at 33°C with a positive balance between inspiratory and expiratory water content. These results suggest that in the case of moderate hypothermia, heat and moisture exchangers should be used cautiously and that heated humidifiers may lead to over-humidification with the currently recommended settings.
- 15 May 2004
- Published by Springer Nature in Intensive Care Medicine
- Vol. 30 (6) , 1017-1031
Year in review in Intensive Care Medicine—2003
- 15 May 2004
- Published by Springer Nature in Intensive Care Medicine
- Vol. 30 (6) , 1017-1031
Year in review in Intensive Care Medicine—2003
- 1 February 2004
- Published by Springer Nature in Intensive Care Medicine
- Vol. 30 (2) , 341
Erratum to: Searching for evidence: don’t forget the foundations
- 1 February 2004
- Published by Springer Nature in Intensive Care Medicine
- Vol. 30 (2) , 341
Erratum to: Searching for evidence: don’t forget the foundations
- 16 November 2003
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 22 (47 suppl) , 31s-37s
Mechanical ventilation: invasiveversusnoninvasive: Table 1—
Mechanical ventilation is the most widely used supportive technique in intensive care units. Several forms of external support for respiration have long been described to assist the failing ventilatory pump, and access to lower airways through tracheostomy or endotracheal tubes had constituted a major advance in the management of patients with respiratory distress. More recently, however, new “noninvasive” ventilation (NIV) techniques, using patient/ventilator interfaces in the form of facial masks, have been designed.The reasons for promoting NIV include a better understanding of the role of ventilatory pump failure in the indications for mechanical ventilation, the development of ventilatory modalities able to work in synchrony with the patient, and the extensive recognition of complications associated with endotracheal intubation and standard mechanical ventilation.NIV has been used primarily for patients with acute hypercapnic ventilatory failure, and especially for acute exacerbation of chronic obstructive pulmonary disease. In this population, the use of NIV is associated with a marked reduction in the need for endotracheal intubation, a decrease in complication rate, a reduced duration of hospital stay and a substantial reduction in hospital mortality. Similar benefits have also been demonstrated in patients with asphyxic forms of acute cardiogenic pulmonary oedema. In patients with primarily hypoxemic forms of respiratory failure, the level of success of NIV is more variable, but major benefits have also been demonstrated in selected populations with no contraindications such as multiple organ failure, loss of consciousness or haemodynamic instability.One important factor in success seems to be the early delivery of noninvasive ventilation during the course of respiratory failure. Noninvasive ventilation allows many of the complications associated with mechanical ventilation to be avoided, especially the occurrence of nosocomial infections. The current use of noninvasive ventilation is growing up, and is becoming a major therapeutic tool in the intensive care unit.
- 16 November 2003
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 22 (47 suppl) , 31s-37s
Mechanical ventilation: invasiveversusnoninvasive: Table 1—
Mechanical ventilation is the most widely used supportive technique in intensive care units. Several forms of external support for respiration have long been described to assist the failing ventilatory pump, and access to lower airways through tracheostomy or endotracheal tubes had constituted a major advance in the management of patients with respiratory distress. More recently, however, new “noninvasive” ventilation (NIV) techniques, using patient/ventilator interfaces in the form of facial masks, have been designed.The reasons for promoting NIV include a better understanding of the role of ventilatory pump failure in the indications for mechanical ventilation, the development of ventilatory modalities able to work in synchrony with the patient, and the extensive recognition of complications associated with endotracheal intubation and standard mechanical ventilation.NIV has been used primarily for patients with acute hypercapnic ventilatory failure, and especially for acute exacerbation of chronic obstructive pulmonary disease. In this population, the use of NIV is associated with a marked reduction in the need for endotracheal intubation, a decrease in complication rate, a reduced duration of hospital stay and a substantial reduction in hospital mortality. Similar benefits have also been demonstrated in patients with asphyxic forms of acute cardiogenic pulmonary oedema. In patients with primarily hypoxemic forms of respiratory failure, the level of success of NIV is more variable, but major benefits have also been demonstrated in selected populations with no contraindications such as multiple organ failure, loss of consciousness or haemodynamic instability.One important factor in success seems to be the early delivery of noninvasive ventilation during the course of respiratory failure. Noninvasive ventilation allows many of the complications associated with mechanical ventilation to be avoided, especially the occurrence of nosocomial infections. The current use of noninvasive ventilation is growing up, and is becoming a major therapeutic tool in the intensive care unit.
- 18 October 2003
- Published by Springer Nature in Intensive Care Medicine
- Vol. 29 (12) , 2109-2111
Searching for evidence: don’t forget the foundations
- 18 October 2003
- Published by Springer Nature in Intensive Care Medicine
- Vol. 29 (12) , 2109-2111
Searching for evidence: don’t forget the foundations