LRLiselotte J. C. Rotteveel

Liselotte J. C. Rotteveel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Liselotte J. C. Rotteveel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Speech Perception after Cochlear Implantation in 53 Patients with Otosclerosis: Multicentre Results

    by Liselotte J.C. Rotteveel, Ad F.M. Snik, Huw Cooper, Deborah J. Mawman, Adriaan F. van Olphen, Emmanuel A.M. Mylanus

    Objectives: To analyse the speech perception performance of 53 cochlear implant recipients with otosclerosis and to evaluate which factors influenced patient performance in this group. The factors included disease-related data such as demographics, pre-operative audiological characteristics, the results of CT scanning and device-related factors. Methods: Data were reviewed on 53 patients with otosclerosis from 4 cochlear implant centres in the United Kingdom and the Netherlands. Comparison of demographics, pre-operative CT scans and audiological data revealed that the patients from the 4 different centres could be considered as one group. Speech perception scores had been obtained with the English AB monosyllable tests and Dutch NVA monosyllable tests. Based on the speech perception scores, the patients were classified as poor or good performers. The characteristics of these subgroups were compared. Results: There was wide variability in the speech perception results. Similar patterns were seen in the phoneme scores and BKB sentence scores between the poor and good performers. The two groups did not differ in age at onset of hearing loss, duration of hearing loss, progression, age at onset of deafness, or duration of deafness. Conclusions: The clinical presentation of the otosclerosis (rapid or slow progression) did not influence speech perception. Better performance was related to less severe signs of otosclerosis on CT scan, full insertion of the electrode array, little or no facial nerve stimulation and little or no need to switch off electrodes.


  • Speech perception in congenitally, pre‐lingually and post‐lingually deaf children expressed in an equivalent hearing loss value

    by L.J.C. Rotteveel, A.F.M. Snik, A.M. Vermeulen, C.W.R.J. Cremers, E.A.M. Mylanus

    To investigate the speech perception performance of children with a cochlear implant (CI) after 3 and 4 years of follow-up and to study the influence of age at implantation, duration of deafness and communication mode on the variability in speech perception performance. A broad battery of speech perception tests was administered to 67 children with a CI. The results were reduced into one measure: the 'equivalent hearing loss (EHL)'. This outcome measure refers to the performance of a reference group of severely and profoundly hearing impaired children with conventional hearing aids. The population comprised 35 congenitally, 17 pre-lingually and 15 post-lingually deaf children implanted between 1989 and 1999. The population was homogeneous with respect to cognition, residual hearing and support at home as a result of conservative inclusion criteria. During the first 2 years after implantation, post-lingually deaf children showed the fastest rate of improvement in speech perception. After 3 years of implant use, the early implanted pre-lingually deaf children and congenitally deaf children implanted under the age of 6 years caught up with the post-lingually deaf children. Pre-lingually deaf children implanted after a relatively long-duration of deafness tended to show poorer performance than those with a shorter duration. Performance of congenitally deaf children implanted after the age of 6 years was poorer and progress was slower. In the congenitally deaf children, 36% of the variability in performance was explained by duration of deafness, whereas in the children with pre- and post-lingually acquired deafness, communication mode explained 69% of the variance. All children derived benefit from their CI for speech perception tasks, but performance varied greatly. Several children reached EHL levels around 70 dB; their speech perception was equal to that of a child with conventional hearing aids who has 70 dB HL. After early implantation, the levels of performance that were eventually achieved differed no more than 10 dB, irrespective of whether the onset of deafness was pre-lingual or postlingual. In congenitally deaf children, duration of deafness played a major role in speech perception performance, whereas in the children with pre-lingually and post-lingually acquired deafness together, mode of communication was a major factor.


  • Cochlear Implantation in 3 Patients with Osteogenesis Imperfecta: Imaging, Surgery and Programming Issues

    by Liselotte J.C. Rotteveel, Andy J. Beynon, Lucas H.M. Mens, Ad F.M. Snik, Jef J. Mulder, Emmanuel A.M. Mylanus

    Osteogenesis imperfecta (OI) is a heterogeneous disease of the connective tissue caused by a defective gene that is responsible for the production of collagen type I, leading to defective bone matrix and connective tissue. Hearing loss affects 35–60% of the patients and will progress to deafness in 2–11% of OI patients for whom cochlear implantation may become the only remaining treatment option. Three patients with OI were retrieved from the Nijmegen Cochlear Implant Centre’s database. Most of the specific observations in ear surgery on patients with OI, such as brittle scutum, sclerotic thickening of the cochlea, hyperplastic mucosa in the middle ear and persistent bleeding, were encountered in these 3 patients. In case 3, with severe deformities on the CT scan, misplacement of the electrode array into the horizontal semicircular canal occurred. In all 3 cases, programming was hindered by nonauditory stimulation. Even after reimplantation, nonauditory sensations lead to case 3 becoming a nonuser. Averaged electrode voltages in case 3 were deviant in accordance with an abnormally conductive otic capsule. Spatial spread of neural excitation responses in cases 1 and 2 suggested intracochlear channel interaction for several electrodes, often in combination with facial nerve stimulation (FNS). In case 1, the estimated pitch of the electrodes that caused FNS varied consistently. Despite the electrophysiological changes, after 1-year follow-up, open set phoneme scores of 81% and 78% were reached in cases 1 and 2, respectively. When aware and prepared for the specific changes of the temporal bone in OI, cochlear implantation can be a safe and feasible procedure. Preoperative imaging is recommended to be fully informed on the morphology of the petrosal bone. In case of severe deformities on the CT scan, during counseling the possibility of misplacement should be mentioned. Rehabilitation is often hindered by FNS requiring frequent refitting.


  • Three‐year follow‐up of children with postmeningitic deafness and partial cochlear implant insertion

    by L.J.C. Rotteveel, Ad.F.M. Snik, A.M. Vermeulen, E.A.M. Mylanus

    Objectives:  To evaluate the long‐term outcome of children with postmeningitic deafness and partial insertion of the Nucleus electrode array, and to compare their speech perception performance with that of children with full insertion of the electrode array.Design:  A battery of seven speech perception tests was administered to 25 children with a cochlear implant (CI). Results were reduced into one score: equivalent hearing loss (EHL).Setting:  Tertiary referral centre.Participants:  The partial insertion group comprised seven children, mean age at implantation 5.5 years, mean duration of deafness 3.6 years. The full‐insertion control group comprised 18 children. Mean age at implantation: 4.4 years; mean duration of deafness: 2.9 years. All the children became deaf between 0 and 3 years of age.Main outcome measures:  Over a 3‐year follow‐up period, the children with partial insertion showed continuing progress, although there was wide variation in performance and the rate of progression. Some open‐set comprehension could even be achieved with the insertion of only eight electrodes of a nucleus device.Results:  Three years after implantation, speech perception in the partial insertion children was poorer than that in the control groups with long (P < 0.01; 95% confidence interval 7–43 dB EHL) and short duration of deafness (P < 0.0001; 95% confidence interval 28–53 dB EHL). They showed slower progress and reached a poorer EHL plateau. Four of the seven children acquired open‐set word recognition.Conclusions:  Patients with partial insertion of the electrode array benefit from a CI, although less than patients with complete insertion.


  • Cochlear Implantation in 53 Patients with Otosclerosis: Demographics, Computed Tomographic Scanning, Surgery, and Complications

    by Liselotte J. C. Rotteveel, David W. Proops, Richard T. Ramsden, Shakeel R. Saeed, Adriaan F. van Olphen, Emmanuel A. M. Mylanus

    To collect data from a large number of cochlear implant recipients with otosclerosis and to make an assessment of these patients' clinical characteristics, computed tomographic scans, surgical findings, and complications, and to quantify the occurrence of postoperative facial nerve stimulation. Retrospective multicenter study. Fifty-three patients with otosclerosis from four cochlear implant centers in the United Kingdom and The Netherlands were reviewed. Sixty surgical procedures were performed in these patients: 57 devices were placed in 56 ears. The computed tomographic imaging demonstrated retrofenestral (cochlear) otosclerotic lesions in the majority of patients. Although not statistically significant, the extent of otosclerotic lesions on the computed tomographic scan as categorized in three types tends to be greater in patients with rapidly progressive hearing loss, in patients in whom there is surgically problematic insertion of the electrode array, and in patients with facial nerve stimulation. In four patients, revision surgery had to be performed. Twenty of 53 (38%) patients experienced facial nerve stimulation at various periods postoperatively. Cochlear implant surgery in patients with otosclerosis can be challenging, with a relatively high number of partial insertions and misplacements of the electrode array demanding revision surgery. A very high proportion of patients experienced facial nerve stimulation mainly caused by the distal electrodes. This must be discussed with patients preoperatively.