FAFriedrich Aigner

Friedrich Aigner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Friedrich Aigner has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Ferdinand Frauscher

    Department of Radiology, Medical University of Innsbruck, Anichstraß 35, 6020 Innsbruck, Austria

    6 shared publications
  • Ethan J. Halpern

    Thomas Jefferson Prostate Diagnostic Center, Thomas Jefferson University, Philadelphia, PA 19107, USA

    4 shared publications
  • Georg Schäfer

    Department of Pathology, Medical University of Innsbruck, Anichstraß 35, 6020 Innsbruck, Austria

    4 shared publications
  • Leo Pallwein

    Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria

    4 shared publications
  • Wolfgang Horninger

    Department of Urology, Medical University of Innsbruck, Anichstraß 35, 6020 Innsbruck, Austria

    4 shared publications
  • Daniel Junker

    Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria

    3 shared publications

Latest Publications

  • Aktueller Stand der multiparametrischen MRT

    by Friedrich Aigner, Leo Pallwein-Prettner, Wolfgang Horninger

    • 1 December 2013
      • Vol. 33  (12) , 5525-30

    The need for repeated urological evaluation in low-risk patients with microscopic hematuria after negative diagnostic work-up.

    by Renate Pichler, Isabel Heidegger, Nicolai Leonhartsberger, Brigitte Stöhr, Friedrich Aigner, Jasmin Bektic, Wolfgang Horninger, Hannes Steiner

    To evaluate the role of repeated urological evaluation after negative initial diagnostic work-up of asymptomatic microhematuria (AMH) in low-risk patients. Criteria for patient inclusion were a complete negative initial diagnostic assessment including ultrasound (US), cystoscopy, upper urinary tract (UUT) imaging using intravenous urography (IVU) or multiphasic computed tomography (CT), absence of risk factors and a follow-up period of at least three years. Based on our institutional practice, urinalysis was repeated yearly; cystoscopy with US was repeated three years after initial work-up. The oncological outcome was evaluated across a mean follow-up of 8 (range: 3.7-10.2) years. A case series of 87 (32.2% of 270) low-risk patients, 56 women and 31 men, with a mean age of 52.4 (range: 19-87) years was studied. Three years after initial work-up, cystoscopy confirmed no bladder carcinoma in any of these 87 patients. Prostate cancer was diagnosed in one (1.1%) patient. In five (5.6%) patients, nephrological evaluation due to concomitant proteinuria on follow-up demonstrated chronic renal insufficiency (n=3), IgA nephropathy (n=1) and papillary necrosis of the kidney (n=1). Low-risk patients with persistent AMH after negative urological evaluation have a neglectable risk of developing bladder cancer on follow-up. Newly-discovered proteinuria on follow-up should be clarified by a nephrologist, as proteinuria could be a sign of significant glomerular disease.


  • Open Access

    Potentials and Limitations of Real-Time Elastography for Prostate Cancer Detection: A Whole-Mount Step Section Analysis

    by Daniel Junker, Georg Schäfer, Friedrich Aigner, Peter Schullian, Leo Pallwein-Prettner, Jasmin Bektic, Wolfgang Horninger, Ethan J. Halpern, Ferdinand Frauscher

    Objectives. To evaluate prostate cancer (PCa) detection rates of real-time elastography (RTE) in dependence of tumor size, tumor volume, localization and histological type.Materials and Methods. Thirdy-nine patients with biopsy proven PCa underwent RTE before radical prostatectomy (RPE) to assess prostate tissue elasticity, and hard lesions were considered suspicious for PCa. After RPE, the prostates were prepared as whole-mount step sections and were compared with imaging findings for analyzing PCa detection rates.Results. RTE detected 6/62 cancer lesions with a maximum diameter of 0–5 mm (9.7%), 10/37 with a maximum diameter of 6–10 mm (27%), 24/34 with a maximum diameter of 11–20 20 mm (70.6%), 14/14 with a maximum diameter of >20 mm (100%) and 40/48 with a volume ≥0.2 cm3(83.3%). Regarding cancer lesions with a volume ≥ 0.2 cm³ there was a significant difference in PCa detection rates between Gleason scores with predominant Gleason pattern 3 compared to those with predominant Gleason pattern 4 or 5 (75% versus 100%;P=0.028).Conclusions. RTE is able to detect PCa of significant tumor volume and of predominant Gleason pattern 4 or 5 with high confidence, but is of limited value in the detection of small cancer lesions.


  • Value of enhanced transrectal ultrasound targeted biopsy for prostate cancer diagnosis: a retrospective data analysis

    by Friedrich Aigner, Georg Schäfer, Eberhard Steiner, Werner Jaschke, Wolfgang Horninger, Thomas R. W. Herrmann, Udo Nagele, Ethan J. Halpern, Ferdinand Frauscher


  • Comparison of Real-time Sonoelastography With T2-Weighted Endorectal Magnetic Resonance Imaging for Prostate Cancer Detection

    by Friedrich Aigner, Leo Pallwein, Michael Schocke, Lebovici Andrei, Daniel Junker, Georg Schäfer, Gregor Mikuz, Florian Pedross, Wolfgang Horninger, Werner Jaschke, et al.

    Objectives The purpose of this study was to compare the value of real-time sonoelastography with T2-weighted endorectal magnetic resonance imaging (MRI) for prostate cancer detection. Methods Thir...


  • Value of Real-Time Elastography Targeted Biopsy for Prostate Cancer Detection in Men With Prostate Specific Antigen 1.25 ng/ml or Greater and 4.00 ng/ml or Less

    by Friedrich Aigner, Leo Pallwein, Daniel Junker, Georg Schäfer, Gregor Mikuz, Florian Pedross, Michael Josef Mitterberger, Werner Jaschke, Ethan J. Halpern, Ferdinand Frauscher

    We assessed the prostate cancer detection rate of real-time elastography targeted biopsy in men with total prostate specific antigen 1.25 ng/ml or greater and 4.00 ng/ml or less. Real-time elastography using an EUB 8500 Hitachi ultrasound system (Hitachi Medical, Tokyo, Japan) was done in 94 men with a mean age of 57.4 years (range 35 to 77) with increased prostate specific antigen between 1.25 ng/ml or greater and 4.00 ng/ml or less (mean 3.20, range 1.30 to 4.00) and a free-to-total prostate specific antigen ratio of less than 18%. Real-time elastography was done to evaluate peripheral zone tissue elasticity and hard areas were defined as suspicious. Targeted biopsies with a maximum of 5 cores were done in suspicious areas, followed by 10-core systematic biopsy. We analyzed the cancer detection rate of real-time elastography and systematic biopsy. Cancer was found in 27 of 94 patients (28.7%). Real-time elastography detected cancer in 20 patients (21.3%) and systematic biopsy detected it in 18 (19.1%). Positive cancer cores were found in real-time elastography targeted cores in 38 of 158 cases (24%) and in systematic cores in 38 of 752 (5.1%) (chi-square test p <0.0001). The cancer detection rate per core was 4.7-fold greater for targeted than for systematic biopsy. Real-time elastography targeted biopsy allows prostate cancer detection in men with prostate specific antigen 1.25 ng/ml or greater and 4 ng/ml or less with a decreased number of cores compared with that of systematic biopsy.


  • Contrast‐enhanced ultrasonography using cadence‐contrast pulse sequencing technology for targeted biopsy of the prostate

    by Friedrich Aigner, Leo Pallwein, Michael Mitterberger, Germar M. Pinggera, Gregor Mikuz, Wolfgang Horninger, Ferdinand Frauscher

    OBJECTIVE: To evaluate contrast‐enhanced ultrasonography (US) using cadence‐contrast pulse sequencing (CPS) technology, compared with systematic biopsy for detecting prostate cancer, as grey‐scale US has low sensitivity and specificity for detecting prostate cancer. PATIENTS AND METHODS: In all, 44 men with suspicious prostate‐specific antigen (PSA) levels and CPS findings were assessed; all had CPS‐targeted and systematic biopsy. Transrectal CPS images were taken with a low mechanical index (0.14). A microbubble contrast agent (SonoVue, Bracco International BV, Amsterdam, the Netherlands) was administered as a bolus, with a maximum dose of 4.8 mL. CPS was used to assess prostatic vascularity. Areas with a rapid and increased contrast enhancement within the peripheral zone were defined as suspicious for prostate cancer. Up to five CPS targeted biopsies were taken and subsequently a 10‐core systematic biopsy was taken. Cancer detection rates for the two techniques were compared. RESULTS: Overall, cancer was detected in 35 of 44 patients (80%), with a mean PSA level of 3.8 ng/mL. Lesions suspicious on CPS showed cancer in 35 of 44 patients (80%) and systematic biopsy detected cancer in 15 of 44 patients (34%). CPS‐targeted cores were positive in 105 of 220 cores (47.7%) and in 41 of 440 systematic biopsy cores (9.3%) ( P < 0.001). Lesions suspicious on CPS were false‐positive in nine of 44 patients (20%). The mean Gleason score for systematic biopsy was 6.7 and for CPS‐targeted biopsy 6.8 ( P > 0.05). The sensitivity of CPS for detecting cancer was 100% (confidence interval, 95%). However, limitations in the series included that only CPS‐positive cases were investigated, and CPS‐targeted biopsy should be evaluated in a more extended biopsy scheme. CONCLUSIONS: Contrast‐enhanced US using CPS enables excellent visualization of the microvasculature associated with prostate cancer, and can improve the detection of prostate cancer compared with systematic biopsy.


  • Open Access

    A possible case of primary renal lymphoma: a case report

    by Germar-Michael Pinggera, Reinhard Peschel, Alexander Buttazzoni, Michael Mitterberger, Aigner Friedrich, Leo Pallwein

    The entity primary renal lymphoma is controversial and rare.


  • Value of magnetic resonance imaging in prostate cancer diagnosis

    by Friedrich Aigner, Leo Pallwein, Alexandre Pelzer, Georg Schaefer, Georg Bartsch, Dieter Zur Nedden, Ferdinand Frauscher

    MRI has shown its potential in prostate cancer (PCa) imaging. MRI is able to demonstrate zonal anatomy with excellent contrast resolution. Furthermore it can detect PCa dependent not only on tumor-size, histological grading, PSA levels, but also on technical equipment and reader’s experience. Non-palpable PCas in the inner and outer gland can be detected by this technique. Another potential is that MRI is helpful for tumor staging and treatment planning as well as response evaluation. Besides the morphological information, MRI can give functional information based on metabolic evaluation with proton magnetic resonance spectroscopy and of tumor angiogenesis based on dynamic contrast-material enhanced MRI and diffusion-weighted imaging. In addition MRI can be used for targeted prostate biopsies; however, the clinical practicability is questionable. Furthermore many data about the value of MRI for PCa diagnosis are based on transrectal ultrasound (TRUS) biopsy findings. Since there is lack of accuracy in fusing MRI images with TRUS images these limit the results of MRI for cancer diagnosis. However, in the future MRI may play an additional role in planning and monitoring minimally invasive PCa therapies. Although, MRI of the prostate seems to be useful, nevertheless this method remains expensive and lacks availability regarding the oncoming requirements.