JMJoseph M. Miller

Joseph M. Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph M. Miller has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Objective Assessment of Spectacle Wear in Infants and Toddlers Using a Wearable Sensor

    by Joseph M. Miller, Leslie K. Dennis, Chiu-Hsieh Hsu, Erin M. Harvey

    Purpose: To assess the feasibility of using a thermal microsensor to monitor spectacle wear in infants and toddlers, to determine the inter-method reliability of two methods of estimating spectacle wear from sensor data, and to validate sensor estimates of wear. Methods: Fourteen children, 3 to Results: Data from two child participants were excluded (one because of corrupted sensor data and the other because of no parent log data). Sensor data were collected more reliably than parent wear reports. The TT and HJ analysis of child data yielded similar reliability. Adult sensor data scored using the HJ method provided more valid estimates of wear than the TT method (κ = 0.94 vs. 0.78). Conclusions: We have demonstrated that it is feasible to deduce periods of spectacle wear using a thermal data logger and that the sensor is tolerated by children. Translational Relevance: Results indicate that it is feasible to use a thermal microsensor to measure spectacle wear for use in clinical monitoring or for research on spectacle treatment in children under 4 years of age.


  • OD, OS, and OU

    by Joseph M. Miller, Harris Ahmed

  • Clinical Applications of Power Vectors

    by Joseph M. Miller

    The study of infant vision is closely coupled to the study of the refraction, change in refraction over time, and the effect of spectacle correction on visual development. Frequently, reports are limited to descriptions of spherical equivalent or cylinder power without regard to axis, as data are frequently collected in the clinical format of sphere, cylinder, and axis (S, C, A). Conversion from clinical notation to a power vector representation of refraction allows unambiguous description of how refractions change over time and differ between repeated measurements. This article presents a series of examples of Microsoft Excel spreadsheet formulas that make the conversion from clinical notation to power vector format, and provides examples of useful applications of these methods.


  • Cost-Efficient Vision Screening for Astigmatism in Native American Preschool Children

    by Joseph M. Miller, Velma Dobson, Erin M. Harvey, Duane L. Sherrill

    Purpose. To design and test a cost-efficient, community-based vision screening program for a population of Native American preschool children in which there is a high prevalence of astigmatism. methods. Based on analysis of vision screening and eye examination data from a preschool population with a 33% prevalence of astigmatism, comparative costs to conduct a 1000-child screening program with a target sensitivity of 90% were estimated for photoscreening, noncycloplegic autorefraction, autokeratometry, and Lea symbols distance visual acuity testing. Results of the cost analysis and examination of sensitivity and specificity data from the preschool population led to development of a hybrid screening program of autokeratometry and visual acuity screening with referral thresholds of 2.25 D of corneal astigmatism or inability to read a 20/63 Lea symbols line on two separate attempts. The screening program was prospectively implemented in a community-based screening of a similar cohort of 167 children, and its efficiency was evaluated by comparison to results of cycloplegic refraction. results. The community-based screening showed 96.8% sensitivity and 79.2% specificity for detecting the presence of refractive astigmatism of 1.50 D or more. conclusions. Referring children who have at least 2.25 D of corneal astigmatism or acuity worse than 20/63 on two attempts, provides the high sensitivity and specificity associated with automated keratometry while maintaining an acuity component that can detect other causes of reduced acuity in the absence of astigmatism.


  • Higher Order Aberrations in Normal, Dilated, Intraocular Lens, and Laser in situ Keratomileusis Corneas

    by Joseph M Miller, Raana Anwaruddin, Jochen Straub, Jim Schwiegerling

    PURPOSE: To compare repeated measures of Zernike polynomial higher-order aberrations in 29 normal, 13 dilated normal, 11 intraocular lens (IOL), 11 laser in situ keratomileusis (LASER), and one refractive keratectomy (RK)ZIOL subject. METHODS: At least three Shack-Hartmann images were obtained from each subject, and higher order (uncorrectable by spectacles) Zernike representation was determined. For each subject, confidence intervals for each Zernike coefficient were determined as a function of pupil size. Significant (P<.05) coefficients were averaged within groups, and group means were compared to normal subjects. RESULTS: No differences were seen between the normal and dilated groups at P=.05. The patients with prior LASEK and IOL surgery showed statistically significant elevation of 4th order spherical aberration and total wavefront variance for pupil sizes greater than 5 mm, compared to normals. CONCLUSION: Both IOL and LASEK surgery elevate spherical aberration and wavefront variance, with increasing magnitude of effect with increasing pupil size, although pupillary dilation alone did not produce statistically different changes, as compared to normal subjects. These findings demonstrate that IOL implantation can produce more net aberrations than LASEK, and demonstrate a new opportunity to optimize surgical results. [J Refract Surg 2002;18:S579-S583]


    • 1 April 2001
      • Vol. 42  (5) , 917-24

    Comparison of preschool vision screening methods in a population with a high prevalence of astigmatism.

    by J M Miller, V Dobson, E M Harvey, D L Sherrill

    To compare the effectiveness of four methods of screening 3- to 5-year-old children for astigmatism high enough to require spectacle correction. Lea Symbols Visual Acuity Screening (LSVAS), MTI Photoscreening (MTIPS), Nidek KM-500 Keratometry Screening (KERS), and Retinomax K-Plus Noncycloplegic Autorefraction Screening (NCARS) were attempted on 379 preschool children who are members of a Native American tribe having a high prevalence of astigmatism that is primarily corneal in origin. The need for spectacle correction was determined by cycloplegic refraction. Receiver Operating Characteristic (ROC) curves were fit, confidence intervals were determined, and area under the curves was compared. Astigmatism > or = 1.00 D was present in the right eye of 47.5% and in the left eye of 48.0% of children. Spectacles were prescribed for children < 48 months of age who had cylinder > or = 2.00 D and children > or = 48 months who had cylinder > or = 1.50 D, with the result that 33% of subjects required spectacles. Area under the ROC curve was 0.98 for NCARS, 0.92 for KERS, 0.78 for MTIPS, and 0.70 for LSVAS, and each of these values differed significantly from the other three (all P < 0.007). Testability was significantly higher for NCARS (99.5%) and KERS (99.7%) than for MTIPS (93.5%) and LSVAS (92.0%). In a population that included many children with astigmatism, objective, fully automated screening methods (NCARS and KERS) were superior to both visual acuity screening and photoscreening with subjective interpretation in identifying children who had astigmatism requiring spectacle correction.


  • Detection of Sloan Crowded Single Letters (SCSL) in the Presence of Induced Refractive Error

    by Joseph M. Miller, Mary Rose Teodoro, Lisa Lane, Jim Schwiegerling, David L. Guyton

    We wished to investigate how normal subjects with optically induced refractive error performed when reading Sloan crowded single letters (SCSL). The 10 Sloan letters are used in the ETDRS Visual Acuity charts. While linear presentations of the letters used in the ETDRS visual acuity chart have been extensively studied, the effect, if any, of single letter presentation with flanking "crowding bars" has not. These contour interaction bars (with 1.5 MAR white space between the letters and bars) are intended to increase the difficulty of reading letters so as to more closely resemble the difficulty of linear presentations. We studied the ability of a group of 10 normal subjects to read crowded single letter presentations of the 10 letters used in the ETDRS wall charts. The frequency of recognition of the individual letters in discriminant lines was measured, as was the threshold acuity for each of the induced refractive errors. Results suggest that crowded, single letter presentations are recognized over a range of refractive errors in a manner similar to the recognition of linear presentations of the same letters. Letters with diagonal strokes (Z,V,N) remain relatively easy to recognize, while round letters (C,O,D) remain most difficult. Copyright 2000 Optical Society of America

    • 1 September 2000
      • Vol. 7  (3) , 187-207

    Astigmatism and Amblyopia among Native American Children (AANAC): design and methods.

    by J M Miller, V M Dobson, E M Harvey, D L Sherrill

    The overall goal of the AANAC study is to improve detection of astigmatism and prevention of amblyopia in populations with a high prevalence of astigmatism. To meet this goal, the study will evaluate four methods of screening for astigmatism in preschool children and will assess both the short-term and long-term benefits of early correction of astigmatism in improving acuity and preventing amblyopia. This paper presents an overview of the design and methodology of the AANAC study. Subjects are members of the Tohono O'Odham Nation, a Native American tribe with a high prevalence of astigmatism. Preschool-age children who attend Head Start are screened with four tools: the Marco Nidek KM-500 autokeratometer, the MTI photoscreener, the Nikon Retinomax K-Plus autorefractor, and the Lea Symbols acuity chart. Sensitivity and specificity for detection of significant astigmatism, as measured by a technique that uses both cycloplegic retinoscopy and cycloplegic autorefraction, is determined for each of the four screening tools. Presence of amblyopia is evaluated by measurement of best-corrected recognition acuity and acuity for orthogonal gratings. Spectacles are provided to all 3-year-old children with > or =2.00 diopters (D) of astigmatism and all 4- and 5-year-old children with > or =1.50 D of astigmatism. Persistence of amblyopia after glasses wearing is evaluated by follow-up measurement of best-corrected recognition acuity and acuity for orthogonal gratings, conducted 2-5 months after glasses are prescribed. Long-term effectiveness of early screening and glasses prescription is evaluated through measurement of recognition acuity in two groups of first-grade children: one group who participated in the Head Start program before the intensive vision screening program was initiated, and a second group who participated in the study's Head Start vision screening program.