Romano Zannoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Romano Zannoli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Corazza
Health Sciences and Technologies-Interdepartmental Center for Industrial Research (CIRI-SDV), Alma Mater Studiorum-University of Bologna, Via Massarenti 9, 40126 Bologna, Italy
6 shared publications Angelo Branzi
3 shared publications- Pier Luca Rossi
Medical Physics Unit, ABESS-Wellbeing, Health and Safety Division, Alma Mater Studiorum-University of Bologna, Bologna, Italy
3 shared publications - Giuseppe Boriani
Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
2 shared publications - Mauro Biffi
Institute of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna , Bologna, Italy
2 shared publications Alberto Cremonesi
1 shared publication
Latest Publications
- Open Access
Passive Aortic Counterpulsation to Reduce Pressure Pulse During Aortic Prosthesis Insertion and Reduce Endoleaks Formation: A Preliminary In Silico Investigation
Over 10% of patients undergoing aortic endograft implantation experience endoleaks within a few years. In the case of type 1a endoleaks, a crack forms between the aorta and the prosthesis collar, allowing blood to pass. This blood fills the aneurysmal sac and can lead to its rupture. None of the strategies, such as prostheses with barbs and hooks or ad hoc pharmacological therapies, can prevent the phenomenon. An alternative approach is to reduce diameter oscillations due to pulsating pressure to improve the endoprosthesis adhesion to the internal vessel walls during the initial post-implantation phases. To reach this objective, we propose to use a passive intra-aortic balloon pump (PIABP) inserted and then maintained inside the vessel immediately after the surgical procedure. We tested our hypothesis in a mechanical mock of the cardiovascular system. A silicon aorta with physiological behavior was created for this purpose. The PIABP was inflated to increasing pressures between systolic and diastolic values (120/80 mmHg). For each aorta and each condition, the variations in aortic diameter between systole and diastole, and the pressure variations, were measured. For the normal aorta, with a PIABP pressure of 110 mmHg, the variations in diameter were reduced by 38%. Assuming an endoprosthesis with a diameter of 30 mm (oversized by 5% compared to the diastolic diameter), the time the oscillations are higher than 30 mm is also reduced by 36%. The results are positive and suggest the usefulness of a biomechanical approach to the problem of type 1a endoleaks. Further in silico and clinical trials are necessary to validate the method.
Open AccessPassive Aortic Counterpulsation to Reduce Pressure Pulse During Aortic Prosthesis Insertion and Reduce Endoleaks Formation: A Preliminary In Silico Investigation
Over 10% of patients undergoing aortic endograft implantation experience endoleaks within a few years. In the case of type 1a endoleaks, a crack forms between the aorta and the prosthesis collar, allowing blood to pass. This blood fills the aneurysmal sac and can lead to its rupture. None of the strategies, such as prostheses with barbs and hooks or ad hoc pharmacological therapies, can prevent the phenomenon. An alternative approach is to reduce diameter oscillations due to pulsating pressure to improve the endoprosthesis adhesion to the internal vessel walls during the initial post-implantation phases. To reach this objective, we propose to use a passive intra-aortic balloon pump (PIABP) inserted and then maintained inside the vessel immediately after the surgical procedure. We tested our hypothesis in a mechanical mock of the cardiovascular system. A silicon aorta with physiological behavior was created for this purpose. The PIABP was inflated to increasing pressures between systolic and diastolic values (120/80 mmHg). For each aorta and each condition, the variations in aortic diameter between systole and diastole, and the pressure variations, were measured. For the normal aorta, with a PIABP pressure of 110 mmHg, the variations in diameter were reduced by 38%. Assuming an endoprosthesis with a diameter of 30 mm (oversized by 5% compared to the diastolic diameter), the time the oscillations are higher than 30 mm is also reduced by 36%. The results are positive and suggest the usefulness of a biomechanical approach to the problem of type 1a endoleaks. Further in silico and clinical trials are necessary to validate the method.
- Open Access
- 3 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1276
Calibrated Hydraulic Resistance Adjuncts for Carbon Dioxide Angiography Optimization
Background: Despite the growing interest in CO2 angiography, some mechanical aspects related to CO2 injection still need to be deepened, and some improvements are still possible. This work explores the possibility of optimizing gas injection into small-sized arteries. Since the image quality depends on how the gas fills the vessel and is strongly dependent on injection flow, the possibility of controlling the flow is mandatory to obtain good results. To better control the flow, we propose to adjunct small tubes with known hydraulic resistances in parallel to the injection catheter, allowing the generation of the desired injection flow by modulating the injection pressure. Methods: Using a mechanical mock of the cardiovascular system, we measured pressures and flows of interest and acquired the optical images of the vessel during gas injections. We performed a simulation with four different calibrated adjunct resistances in various injection pressure conditions, with and without saline flushing. Results: Our tests demonstrated that the optimized injection of the gas maintains the same procedure durations and reduces the gas volume and the local pressure increase, avoiding the local gas “explosion” in the injection site. Conclusions: Our proposal appears effective and paves the way for research into optimizing clinical CO2 angiography procedures.
- 3 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1276
Open AccessCalibrated Hydraulic Resistance Adjuncts for Carbon Dioxide Angiography Optimization
Background: Despite the growing interest in CO2 angiography, some mechanical aspects related to CO2 injection still need to be deepened, and some improvements are still possible. This work explores the possibility of optimizing gas injection into small-sized arteries. Since the image quality depends on how the gas fills the vessel and is strongly dependent on injection flow, the possibility of controlling the flow is mandatory to obtain good results. To better control the flow, we propose to adjunct small tubes with known hydraulic resistances in parallel to the injection catheter, allowing the generation of the desired injection flow by modulating the injection pressure. Methods: Using a mechanical mock of the cardiovascular system, we measured pressures and flows of interest and acquired the optical images of the vessel during gas injections. We performed a simulation with four different calibrated adjunct resistances in various injection pressure conditions, with and without saline flushing. Results: Our tests demonstrated that the optimized injection of the gas maintains the same procedure durations and reduces the gas volume and the local pressure increase, avoiding the local gas “explosion” in the injection site. Conclusions: Our proposal appears effective and paves the way for research into optimizing clinical CO2 angiography procedures.
- 1 March 2017
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 33, 255-260
A simple and innovative way to measure ventricular volume in a mechanical mock of the left ventricle
- 1 March 2017
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 33, 255-260
A simple and innovative way to measure ventricular volume in a mechanical mock of the left ventricle
- 25 July 2014
- Published by Societa Editrice Esculapio
Elementi di Fisica
- 1 January 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (1) , 33-38
Mechanical aspects of CO2 angiography
- 1 January 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (1) , 33-38
Mechanical aspects of CO2 angiography
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (14) , 3089-3095
A mechanical device for aortic compliance modulation: In vitro simulation of aortic dissection treatment
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (14) , 3089-3095
A mechanical device for aortic compliance modulation: In vitro simulation of aortic dissection treatment
- 24 April 2003
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (5) , 1218-1226
Late Improvement in Ventricular Performance Following Internal Cardioversion for Persistent Atrial Fibrillation:
The aim of the study was to evaluate the time course of atrial and ventricular function improvement following internal atrial cardioversion in patients with structural heart disease. Twenty-nine patients with chronic persistent atrial fibrillation (AF) and underlying structural heart disease were followed by serial echocardiograms performed at 1 and 6 hours, 1 day, 1, 2, and 3 weeks, and 1, 2, 3, and 6 months after successful cardioversion. Sinus rhythm was maintained at 6 months in 24 patients. Following cardioversion the time course of left atrial mechanical function (peak A wave, percent A wave filling) differed from that of left ventricular ejection fraction: peak A wave values (cm/s) increased significantly at 1 week (51 +/- 23 vs 35 +/- 15 at 1 hour, P < 0.05), percent A wave filling (%) increased significantly at 2 weeks (34 +/- 12 vs 22 +/- 9 at 1 hour, P < 0.05), whereas left ventricular ejection fraction (%) increased later (at 1 month 60 +/- 14 vs 55 +/- 14 at baseline, P < 0.05 and at 2 months 60 +/- 14 vs 56 +/- 14 at 1 hour, P < 0.05). In conclusion, restoration of sinus rhythm results in an improvement in left ventricular ejection fraction during follow-up, even in patients with structural heart disease without fast ventricular rates at baseline. The dissociation between the time course of atrial and ventricular function improvement suggests that the latter was partly due to regression of a concealed form of cardiomyopathy and/or of a ventricular dysfunction due to chronic AF
- 24 April 2003
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (5) , 1218-1226
Late Improvement in Ventricular Performance Following Internal Cardioversion for Persistent Atrial Fibrillation:
The aim of the study was to evaluate the time course of atrial and ventricular function improvement following internal atrial cardioversion in patients with structural heart disease. Twenty-nine patients with chronic persistent atrial fibrillation (AF) and underlying structural heart disease were followed by serial echocardiograms performed at 1 and 6 hours, 1 day, 1, 2, and 3 weeks, and 1, 2, 3, and 6 months after successful cardioversion. Sinus rhythm was maintained at 6 months in 24 patients. Following cardioversion the time course of left atrial mechanical function (peak A wave, percent A wave filling) differed from that of left ventricular ejection fraction: peak A wave values (cm/s) increased significantly at 1 week (51 +/- 23 vs 35 +/- 15 at 1 hour, P < 0.05), percent A wave filling (%) increased significantly at 2 weeks (34 +/- 12 vs 22 +/- 9 at 1 hour, P < 0.05), whereas left ventricular ejection fraction (%) increased later (at 1 month 60 +/- 14 vs 55 +/- 14 at baseline, P < 0.05 and at 2 months 60 +/- 14 vs 56 +/- 14 at 1 hour, P < 0.05). In conclusion, restoration of sinus rhythm results in an improvement in left ventricular ejection fraction during follow-up, even in patients with structural heart disease without fast ventricular rates at baseline. The dissociation between the time course of atrial and ventricular function improvement suggests that the latter was partly due to regression of a concealed form of cardiomyopathy and/or of a ventricular dysfunction due to chronic AF
- 1 November 2002
- Published by Elsevier in American Heart Journal
- Vol. 144 (5) , 851-857
Electrophysiology transvenous internal cardioversion for atrial fibrillation: A randomized comparison between catheters with different Coll length
- 1 November 2002
- Published by Elsevier in American Heart Journal
- Vol. 144 (5) , 851-857
Electrophysiology transvenous internal cardioversion for atrial fibrillation: A randomized comparison between catheters with different Coll length