V. Andrew Stenger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. Andrew Stenger has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Douglas C. Noll
Department of Biomedical Engineering University of Michigan Ann Arbor Michigan USA
3 shared publications Fernando E. Boada
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania
3 shared publicationsSuwit Saekho
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15213, USA
1 shared publication
Latest Publications
- Open Access
- 27 January 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 479-484
Small tip angle three‐dimensional tailored radiofrequency slab‐select pulse for reduced B1 inhomogeneity at 3 T
This work presents a small tip‐angle 3D tailored RF slab‐select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil. Magn Reson Med 53:479–484, 2005.
- 27 January 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 479-484
Open AccessSmall tip angle three‐dimensional tailored radiofrequency slab‐select pulse for reduced B1 inhomogeneity at 3 T
This work presents a small tip‐angle 3D tailored RF slab‐select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil. Magn Reson Med 53:479–484, 2005.
- Open Access
- 24 October 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (5) , 1100-1106
Variable-density spiral 3D tailored RF pulses
- 24 October 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (5) , 1100-1106
Open AccessVariable-density spiral 3D tailored RF pulses
- Open Access
- 27 June 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (1) , 157-165
Multishot 3D slice‐select tailored RF pulses for MRI
A multishot 3D slice‐select tailored RF pulse method is presented for the excitation of slice profiles with arbitrary resolution. This method is derived from the linearity of the small tip angle approximation, allowing for the decomposition of small tip angle tailored RF pulses into separate excitations. The final image is created by complex summation of the images acquired from the individual excitations. This technique overcomes the limitation of requiring a long pulse to excite thin slices with adequate resolution. This has implications in applications including T‐weighted functional MRI in brain regions corrupted by intravoxel dephasing artifacts due to susceptibility variations. Simulations, phantom experiments, and human brain images are presented. It is demonstrated that at most four shots of 40 ms pulse length are needed to excite a 5 mm‐thick slice in the brain with reduced susceptibility artifacts at 3T. Magn Reson Med 48:157–165, 2002.
- 27 June 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (1) , 157-165
Open AccessMultishot 3D slice‐select tailored RF pulses for MRI
A multishot 3D slice‐select tailored RF pulse method is presented for the excitation of slice profiles with arbitrary resolution. This method is derived from the linearity of the small tip angle approximation, allowing for the decomposition of small tip angle tailored RF pulses into separate excitations. The final image is created by complex summation of the images acquired from the individual excitations. This technique overcomes the limitation of requiring a long pulse to excite thin slices with adequate resolution. This has implications in applications including T‐weighted functional MRI in brain regions corrupted by intravoxel dephasing artifacts due to susceptibility variations. Simulations, phantom experiments, and human brain images are presented. It is demonstrated that at most four shots of 40 ms pulse length are needed to excite a 5 mm‐thick slice in the brain with reduced susceptibility artifacts at 3T. Magn Reson Med 48:157–165, 2002.