Georges Limbert
Research Subjects
Georges Limbert has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
John Middleton
3 shared publications- Mark Taylor
College of Science and Engineering Flinders University Adelaide Australia
2 shared publications Ivar Knets
Institute of Biomaterials and Biomechanics , Riga Technical University , Kalku iela 1, LV1658, Riga, Latvia
1 shared publicationJ. Middleton
1 shared publicationJanis Laizans
Institute of Biomaterials and Biomechanics , Riga Technical University , Kalku iela 1, LV1658, Riga, Latvia
1 shared publication- Modris Dobelis
Riga Technical University
1 shared publication
Latest Publications
- 24 May 2005
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 28 (2) , 99-113
A constitutive model of the posterior cruciate ligament
Further to our previous work on the development of a general constitutive framework for transversely isotropic viscohyperelasticity (Limbert, G, Middleton, J. A transversely isotropic viscohyperelastic material. Application to the modelling of biological soft connective tissues. Int J Solids Struct 2004;41(15):4237-60.), we propose a phenomenological constitutive law to describe the anisotropic viscohyperelastic behaviour of the human posterior cruciate ligament (PCL) at high strain rates. The mechanical formulation is based on the definition of a Helmholtz free energy function containing a hyperelastic and a viscous potential. The equations are valid for arbitrary kinematics and satisfy elemental thermodynamic principles. Identification of the constitutive model with experimental data obtained from human PCL specimens was performed and showed the ability of the model to capture accurately the mechanical characteristics of the PCL at various strain rates. Influence of the isotropic and directional viscous stress responses on the global mechanical response are discussed in connection with the modelling hypotheses. This work was motivated by the need to provide an accurate constitutive model of the PCL to be used in finite element analyses of human occupants in car crash simulations. Besides uniaxial tests along the natural fibre orientation of the PCL, additional tests such as equibiaxial, strip biaxial compression-tension and shear tests were also performed in order to assess the physical response of the model in different loading situations. It was found that the model performed as well in these conditions.
- 24 May 2005
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 28 (2) , 99-113
A constitutive model of the posterior cruciate ligament
Further to our previous work on the development of a general constitutive framework for transversely isotropic viscohyperelasticity (Limbert, G, Middleton, J. A transversely isotropic viscohyperelastic material. Application to the modelling of biological soft connective tissues. Int J Solids Struct 2004;41(15):4237-60.), we propose a phenomenological constitutive law to describe the anisotropic viscohyperelastic behaviour of the human posterior cruciate ligament (PCL) at high strain rates. The mechanical formulation is based on the definition of a Helmholtz free energy function containing a hyperelastic and a viscous potential. The equations are valid for arbitrary kinematics and satisfy elemental thermodynamic principles. Identification of the constitutive model with experimental data obtained from human PCL specimens was performed and showed the ability of the model to capture accurately the mechanical characteristics of the PCL at various strain rates. Influence of the isotropic and directional viscous stress responses on the global mechanical response are discussed in connection with the modelling hypotheses. This work was motivated by the need to provide an accurate constitutive model of the PCL to be used in finite element analyses of human occupants in car crash simulations. Besides uniaxial tests along the natural fibre orientation of the PCL, additional tests such as equibiaxial, strip biaxial compression-tension and shear tests were also performed in order to assess the physical response of the model in different loading situations. It was found that the model performed as well in these conditions.
- 1 November 2004
- Published by Elsevier in Journal of Biomechanics
- Vol. 37 (11) , 1723-1731
Three-dimensional finite element modelling of the human ACL: simulation of passive knee flexion with a stressed and stress-free ACL
- 1 November 2004
- Published by Elsevier in Journal of Biomechanics
- Vol. 37 (11) , 1723-1731
Three-dimensional finite element modelling of the human ACL: simulation of passive knee flexion with a stressed and stress-free ACL
- 1 February 2004
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 7 (1) , 1-8
Finite Element Analysis of the Human ACL Subjected to Passive Anterior Tibial Loads
In this study, a constitutive law based on a nearly incompressible transversely isotropic hyperelastic potential is proposed to describe the mechanical behaviour of the anterior cruciate ligament (ACL). The constitutive formulation is valid for arbitrary kinematics (finite elasticity) and is thermodynamically admissible. Based on anatomic measurements performed on a human cadaveric knee specimen, a three-dimensional continuum finite element model of the ACL was developed. The numerical model was used to simulate clinical procedures such as the Lachman and drawer tests, which are performed to assess the existence and severity of an ACL injury. Finite element analyses showed that the two procedures have distinct effects on the behaviour of the ACL and provided new insights into the stress distributions. Moreover, good qualitative and quantitative agreement was found between the present study and results obtained experimentally in comparable conditions.
- 1 February 2004
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 7 (1) , 1-8
Finite Element Analysis of the Human ACL Subjected to Passive Anterior Tibial Loads
In this study, a constitutive law based on a nearly incompressible transversely isotropic hyperelastic potential is proposed to describe the mechanical behaviour of the anterior cruciate ligament (ACL). The constitutive formulation is valid for arbitrary kinematics (finite elasticity) and is thermodynamically admissible. Based on anatomic measurements performed on a human cadaveric knee specimen, a three-dimensional continuum finite element model of the ACL was developed. The numerical model was used to simulate clinical procedures such as the Lachman and drawer tests, which are performed to assess the existence and severity of an ACL injury. Finite element analyses showed that the two procedures have distinct effects on the behaviour of the ACL and provided new insights into the stress distributions. Moreover, good qualitative and quantitative agreement was found between the present study and results obtained experimentally in comparable conditions.
- 1 October 2003
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 6 (5-6) , 337-345
A Transversely Isotropic Hyperelastic Constitutive Model of the PDL. Analytical and Computational Aspects
This study describes the development of a constitutive law for the modelling of the periodontal ligament (PDL) and its practical implementation into a commercial finite element code. The constitutive equations encompass the essential mechanical features of this biological soft tissue: non-linear behaviour, large deformations, anisotropy, distinct behaviour in tension and compression and the fibrous characteristics. The approach is based on the theory of continuum fibre-reinforced composites at finite strain where a compressible transversely isotropic hyperelastic strain energy function is defined. This strain energy density function is further split into volumetric and deviatoric contributions separating the bulk and shear responses of the material. Explicit expressions of the stress tensors in the material and spatial configurations are first established followed by original expressions of the elasticity tensors in the material and spatial configurations. As a simple application of the constitutive model, two finite element analyses simulating the mechanical behaviour of the PDL are performed. The results highlight the significance of integrating the fibrous architecture of the PDL as this feature is shown to be responsible for the complex strain distribution observed.
- 1 October 2003
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 6 (5-6) , 337-345
A Transversely Isotropic Hyperelastic Constitutive Model of the PDL. Analytical and Computational Aspects
This study describes the development of a constitutive law for the modelling of the periodontal ligament (PDL) and its practical implementation into a commercial finite element code. The constitutive equations encompass the essential mechanical features of this biological soft tissue: non-linear behaviour, large deformations, anisotropy, distinct behaviour in tension and compression and the fibrous characteristics. The approach is based on the theory of continuum fibre-reinforced composites at finite strain where a compressible transversely isotropic hyperelastic strain energy function is defined. This strain energy density function is further split into volumetric and deviatoric contributions separating the bulk and shear responses of the material. Explicit expressions of the stress tensors in the material and spatial configurations are first established followed by original expressions of the elasticity tensors in the material and spatial configurations. As a simple application of the constitutive model, two finite element analyses simulating the mechanical behaviour of the PDL are performed. The results highlight the significance of integrating the fibrous architecture of the PDL as this feature is shown to be responsible for the complex strain distribution observed.