Albert E. Raizner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Albert E. Raizner has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Grzegorz L. Kałuża
The Methodist DeBakey Heart Center and Section of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, Texas
3 shared publications Grzegorz L Kaluza
The Methodist DeBakey Heart Center and Baylor College of Medicine, Houston, Texas, USA
2 shared publicationsGrzegorz L. Kaluza
The Methodist DeBakey Heart Center and Baylor College of Medicine, Houston, Texas
2 shared publicationsNadir M Ali
Methodist DeBakey Heart Center and Baylor College of Medicine, Houston, TX, USA
2 shared publicationsNadir M. Ali
From Baylor College of Medicine, Houston, Tex (A.E.R., J.K.C., G.L.K., N.M.A.); Stanford University, Stanford, Calif (S.N.O., A.C.Y., P.J.F.); Washington Hospital Center, Washington, DC (R.W., L.R.W.); Thoraxcenter, Rotterdam, The Netherlands (P.W.S., W.J.v.d.G.); Centro Cuore Columbus, Milan, Italy (A.C.); National Heart Center, Singapore (Y.-L.L.); and Guidant Vascular Intervention, Santa Clara, Calif (L.V.).
2 shared publicationsValerian Fernandes
The Methodist DeBakey Heart Center and Section of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, Texas 77030, USA
2 shared publications
Latest Publications
- 20 April 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (6) , 856
Magnetic navigation: A pivotal technology
- 20 April 2007
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 69 (6) , 856
Magnetic navigation: A pivotal technology
- 24 May 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 56 (2) , 281-288
Intracoronary brachytherapy
- 24 May 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 56 (2) , 281-288
Intracoronary brachytherapy
- 18 March 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (4) , 485-490
Novel technique for stent delivery in tortuous coronary arteries: Report of three cases
We present a novel technique for stent delivery across tortuous lesions. Gentle forward pressure was applied on the stent balloon while the balloon was inflated to 2-3 atm. This resulted in the balloon and stent crossing the impeding segment and settling in the target site where it was deployed with excellent angiographic outcome.
- 18 March 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (4) , 485-490
Novel technique for stent delivery in tortuous coronary arteries: Report of three cases
We present a novel technique for stent delivery across tortuous lesions. Gentle forward pressure was applied on the stent balloon while the balloon was inflated to 2-3 atm. This resulted in the balloon and stent crossing the impeding segment and settling in the target site where it was deployed with excellent angiographic outcome.
- 21 February 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (3) , 376-380
Successful balloon valvuloplasty in an adult patient with severe pulmonic stenosis and aneurysmal poststenotic dilatation
We present a case of pulmonic stenosis with large aneurysmal poststenotic dilatation that was safely and effectively treated with balloon valvuloplasty. Though the poststenotic dilatation persists after the procedure, the risk of dissection and rupture is very low. Hence, balloon valvuloplasty should be considered the treatment of choice in this setting.
- 21 February 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (3) , 376-380
Successful balloon valvuloplasty in an adult patient with severe pulmonic stenosis and aneurysmal poststenotic dilatation
We present a case of pulmonic stenosis with large aneurysmal poststenotic dilatation that was safely and effectively treated with balloon valvuloplasty. Though the poststenotic dilatation persists after the procedure, the risk of dissection and rupture is very low. Hence, balloon valvuloplasty should be considered the treatment of choice in this setting.
- 1 April 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 52 (4) , 518-529
Basic science review: Radiotherapy for prevention of restenosis
- 1 April 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 52 (4) , 518-529
Basic science review: Radiotherapy for prevention of restenosis
- Open Access
- 1 February 2001
- Published by Springer Nature in Current Controlled Trials in Cardiovascular Medicine
- Vol. 2 (1) , 16-19
The Proliferation REduction with Vascular ENergy Trial (PREVENT)
PREVENT was the first prospective, randomized placebo-controlled study of intracoronary beta radiotherapy with 32P. A total of 105 patients with de novo or restenotic lesions, treated by stenting or balloon angioplasty, received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm beyond the lumen surface. Rates of restenosis (50% diameter stenosis or more) were significantly lower in radiotherapy patients at the target site (8% compared with 39%, P = 0.012) and at the target site plus adjacent segments (22% compared with 50%, P = 0.018). Stenosis adjacent to the target site and late thrombotic events reduced the overall clinical benefit of radiotherapy.
- 1 February 2001
- Published by Springer Nature in Current Controlled Trials in Cardiovascular Medicine
- Vol. 2 (1) , 16-19
Open AccessThe Proliferation REduction with Vascular ENergy Trial (PREVENT)
PREVENT was the first prospective, randomized placebo-controlled study of intracoronary beta radiotherapy with 32P. A total of 105 patients with de novo or restenotic lesions, treated by stenting or balloon angioplasty, received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm beyond the lumen surface. Rates of restenosis (50% diameter stenosis or more) were significantly lower in radiotherapy patients at the target site (8% compared with 39%, P = 0.012) and at the target site plus adjacent segments (22% compared with 50%, P = 0.018). Stenosis adjacent to the target site and late thrombotic events reduced the overall clinical benefit of radiotherapy.
- 29 August 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (9) , 951-958
Inhibition of Restenosis With β-Emitting Radiotherapy
Background —Intracoronary γ- and β-radiation have reduced restenosis in animal models. In the clinical setting, the effectiveness of β-emitters has not been studied in a broad spectrum of patients, particularly those receiving stents. Methods and Results —A prospective, randomized, sham-controlled study of intracoronary radiotherapy with the β-emitting 32 P source wire, using a centering catheter and automated source delivery unit, was conducted. A total of 105 patients with de novo (70%) or restenotic (30%) lesions who were treated by stenting (61%) or balloon angioplasty (39%) received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm in the artery wall. Angiography at 6 months showed a target site late loss index of 11±36% in radiotherapy patients versus 55±30% in controls ( P P =0.012) and at target site plus adjacent segments (22% versus 50%; P =0.018). Target lesion revascularization was needed in 5 radiotherapy patients (6%) and 6 controls (24%; P Conclusions —β-radiotherapy with a centered 32 P source is safe and highly effective in inhibiting restenosis at the target site after stent or balloon angioplasty. However, minimizing edge narrowing and late thrombotic events must be accomplished to maximize the clinical benefit of this modality.
- 29 August 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (9) , 951-958
Inhibition of Restenosis With β-Emitting Radiotherapy
Background —Intracoronary γ- and β-radiation have reduced restenosis in animal models. In the clinical setting, the effectiveness of β-emitters has not been studied in a broad spectrum of patients, particularly those receiving stents. Methods and Results —A prospective, randomized, sham-controlled study of intracoronary radiotherapy with the β-emitting 32 P source wire, using a centering catheter and automated source delivery unit, was conducted. A total of 105 patients with de novo (70%) or restenotic (30%) lesions who were treated by stenting (61%) or balloon angioplasty (39%) received 0 (control), 16, 20, or 24 Gy to a depth of 1 mm in the artery wall. Angiography at 6 months showed a target site late loss index of 11±36% in radiotherapy patients versus 55±30% in controls ( P P =0.012) and at target site plus adjacent segments (22% versus 50%; P =0.018). Target lesion revascularization was needed in 5 radiotherapy patients (6%) and 6 controls (24%; P Conclusions —β-radiotherapy with a centered 32 P source is safe and highly effective in inhibiting restenosis at the target site after stent or balloon angioplasty. However, minimizing edge narrowing and late thrombotic events must be accomplished to maximize the clinical benefit of this modality.
- 1 January 2000
- Published by Taylor & Francis in Annals of Medicine
- Vol. 32 (9) , 622-631
Intracoronary radiotherapy for prevention of restenosis after percutaneous coronary interventions
More than 50 different pharmacological and mechanical interventions have been tested to date for prevention of vascular restenosis without success. Intracoronary radiotherapy is the first one showing promise of significantly attenuating neointimal proliferation, causing positive vascular remodelling and thus inhibiting restenosis. This promising modality has moved from animal experiments via safety and feasibility testing into the phase of clinical trials of efficacy in large numbers of patients. While ongoing research continues to search for new sources and delivery techniques, currently available technology is being optimized. The randomized clinical trials conducted to date have shown consistently a reduction of target site restenosis rates by 55–79%. Lower incidence of major adverse cardiac events after radiotherapy has also been demonstrated, primarily as a result of reduction in target site and target vessel revascularization rates. However, experimental and clinical research has identified two major complications of this approach: stenosis at the ends of the radiation zone ('edge effect' or 'candywrapper') as well as late thrombosis (beyond 30 days after intervention) of the angioplasty or stent site. If these two adverse effects can be minimized, intracoronary radiotherapy may prove to be a major breakthrough in percutaneous coronary interventions.
- 1 January 2000
- Published by Taylor & Francis in Annals of Medicine
- Vol. 32 (9) , 622-631
Intracoronary radiotherapy for prevention of restenosis after percutaneous coronary interventions
More than 50 different pharmacological and mechanical interventions have been tested to date for prevention of vascular restenosis without success. Intracoronary radiotherapy is the first one showing promise of significantly attenuating neointimal proliferation, causing positive vascular remodelling and thus inhibiting restenosis. This promising modality has moved from animal experiments via safety and feasibility testing into the phase of clinical trials of efficacy in large numbers of patients. While ongoing research continues to search for new sources and delivery techniques, currently available technology is being optimized. The randomized clinical trials conducted to date have shown consistently a reduction of target site restenosis rates by 55–79%. Lower incidence of major adverse cardiac events after radiotherapy has also been demonstrated, primarily as a result of reduction in target site and target vessel revascularization rates. However, experimental and clinical research has identified two major complications of this approach: stenosis at the ends of the radiation zone ('edge effect' or 'candywrapper') as well as late thrombosis (beyond 30 days after intervention) of the angioplasty or stent site. If these two adverse effects can be minimized, intracoronary radiotherapy may prove to be a major breakthrough in percutaneous coronary interventions.
- 1 July 1999
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 1 (3) , 214-219
Clinical experience with a spiral balloon centering catheter for the delivery of intracoronary radiation therapy
- 1 July 1999
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 1 (3) , 214-219
Clinical experience with a spiral balloon centering catheter for the delivery of intracoronary radiation therapy