Dimos Baltas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dimos Baltas has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Chengyu Shi
7979 Wurzbach Rd Ste 240, Cancer Therapy and Research Center, Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, TX, 78229, USA
1 shared publication Courtney Buckey
Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, TX, United States; Department of Radiation Oncology, Mayo Clinic, Scottsdale, AZ, United States
1 shared publicationEdgar Löffler
Ibt-Bebig, IBt s.a., 7180 Seneffe, Belgium
1 shared publication- Fan-Chi Su
Department of Therapeutic Radiology, Yale-New Haven Hospital, 20 York street, New Haven, CT 06510, USA
1 shared publication Georgia Lymperopoulou
Department of Medical Physics, Attikon University Hospital, 12462 Athens, Greece
1 shared publication- Georgios Chatzikonstantinou
Department of Radiation Oncology, Klinikum Offenbach, Starkenburgring 66, 63069, Offenbach, Germany
1 shared publication
Latest Publications
- 1 August 2017
- Published by Elsevier in Physica Medica
- Vol. 40, 33-41
Radiobiological evaluation of prostate cancer IMRT and conformal-RT plans using different treatment protocols
- 1 August 2017
- Published by Elsevier in Physica Medica
- Vol. 40, 33-41
Radiobiological evaluation of prostate cancer IMRT and conformal-RT plans using different treatment protocols
- Open Access
- 8 May 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 115
High dose rate brachytherapy as monotherapy for localised prostate cancer: a hypofractionated two-implant approach in 351 consecutive patients
To report the clinical outcome of high dose rate brachytherapy as sole treatment for clinically localised prostate cancer.
- 8 May 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 115
Open AccessHigh dose rate brachytherapy as monotherapy for localised prostate cancer: a hypofractionated two-implant approach in 351 consecutive patients
To report the clinical outcome of high dose rate brachytherapy as sole treatment for clinically localised prostate cancer.
- 13 May 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2572-2586
A radiobiological investigation on dose and dose rate for permanent implant brachytherapy of breast using or sources
Purpose: The present report addresses the question of what could be the appropriate dose and dose rate for and permanent seed implants for breast cancer as monotherapy for early stage breast cancer. This is addressed by employing a radiobiological methodology, which is based on the linear quadratic model, to identify a biologically effective dose (BED) to the prescription point of the brachytherapy implant, which would produce equivalent cell killing (or same cell survival) when compared to a specified external radiotherapy scheme.Methods: In the present analysis, the tumor and normal tissue BED ratios of brachytherapy and external radiotherapy are examined for different combinations of tumor proliferation constant , ratios, initial dose rate , and reference external radiotherapy scheme (50 or 60 Gy in 2 Gy per fraction). The results of the radiobiological analysis are compared against other reports and clinical protocols in order to examine possible opportunities of improvement.Results: The analysis indicates that physical doses of approximately 100–110 Gy delivered with an initial dose rate of around and 78–80 Gy delivered at for and permanent implants, respectively, are equivalent to 50 Gy external beam radiotherapy (EBRT) in 2 Gy per fraction. Similarly, for physical doses of approximately 115–127 Gy delivered with an initial dose rate of around and 92 Gy delivered at for and , respectively, are equivalent to 60 Gy EBRT in 2 Gy per fraction. It is shown that the initial dose rate required to produce isoeffective tumor response with 50 or 60 Gy EBRT in 2 Gy per fraction increases as the repopulation factor increases, even though repopulation is also considered in EBRT. Also, the initial dose rate increases as the value of the ratio decreases. The impact of the different ratios on the ratio of the tumor BEDs is significantly large for both the and implants with the deviation between the ratios and those using the 4.0 and 3.5 Gy values ranging between 18% and 22% in most of the cases.Conclusions: For the cases of and , the equivalent physical doses to 50 Gy EBRT in 2 Gy per fraction are associated with an overdosage of the involved normal tissue in the range of 4%–16% and an underdosage by 10%–15% for a BED for normal tissue, using an value of 3.0 Gy of 100 Gy. These values are lower by 10%–20% than the published value of 124 Gy for and by about 13% when compared to the published isoeffective dose of 90 Gy for . Similarly, the equivalent physical doses to 60 Gy EBRT in 2 Gy per fraction are associated with an overdosage of the involved normal tissue by 10%–20% and an underdosage by 4%–10% for of 110 Gy.
- 13 May 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2572-2586
A radiobiological investigation on dose and dose rate for permanent implant brachytherapy of breast using or sources
Purpose: The present report addresses the question of what could be the appropriate dose and dose rate for and permanent seed implants for breast cancer as monotherapy for early stage breast cancer. This is addressed by employing a radiobiological methodology, which is based on the linear quadratic model, to identify a biologically effective dose (BED) to the prescription point of the brachytherapy implant, which would produce equivalent cell killing (or same cell survival) when compared to a specified external radiotherapy scheme.Methods: In the present analysis, the tumor and normal tissue BED ratios of brachytherapy and external radiotherapy are examined for different combinations of tumor proliferation constant , ratios, initial dose rate , and reference external radiotherapy scheme (50 or 60 Gy in 2 Gy per fraction). The results of the radiobiological analysis are compared against other reports and clinical protocols in order to examine possible opportunities of improvement.Results: The analysis indicates that physical doses of approximately 100–110 Gy delivered with an initial dose rate of around and 78–80 Gy delivered at for and permanent implants, respectively, are equivalent to 50 Gy external beam radiotherapy (EBRT) in 2 Gy per fraction. Similarly, for physical doses of approximately 115–127 Gy delivered with an initial dose rate of around and 92 Gy delivered at for and , respectively, are equivalent to 60 Gy EBRT in 2 Gy per fraction. It is shown that the initial dose rate required to produce isoeffective tumor response with 50 or 60 Gy EBRT in 2 Gy per fraction increases as the repopulation factor increases, even though repopulation is also considered in EBRT. Also, the initial dose rate increases as the value of the ratio decreases. The impact of the different ratios on the ratio of the tumor BEDs is significantly large for both the and implants with the deviation between the ratios and those using the 4.0 and 3.5 Gy values ranging between 18% and 22% in most of the cases.Conclusions: For the cases of and , the equivalent physical doses to 50 Gy EBRT in 2 Gy per fraction are associated with an overdosage of the involved normal tissue in the range of 4%–16% and an underdosage by 10%–15% for a BED for normal tissue, using an value of 3.0 Gy of 100 Gy. These values are lower by 10%–20% than the published value of 124 Gy for and by about 13% when compared to the published isoeffective dose of 90 Gy for . Similarly, the equivalent physical doses to 60 Gy EBRT in 2 Gy per fraction are associated with an overdosage of the involved normal tissue by 10%–20% and an underdosage by 4%–10% for of 110 Gy.
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 303-306
Evaluation on Lung Cancer Patients’ Four-dimensional Treatment Plans Utilizing Biologically Effective Uniform Dose
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 303-306
Evaluation on Lung Cancer Patients’ Four-dimensional Treatment Plans Utilizing Biologically Effective Uniform Dose
- 28 April 2006
- Published by Wiley in Medical Physics
- Vol. 33 (5) , 1522-1523
On the dose rate constant of the selectSeed I125 interstitial brachytherapy seed
- 28 April 2006
- Published by Wiley in Medical Physics
- Vol. 33 (5) , 1522-1523